Use & Care Guide
Page 2
... U.S.A 13 In Canada 13 Accessories 13 WARRANTY 14 TABLE DES MATIÈRES SÉCURITÉ DE LA HOTTE DE CUISINIÈRE 15 EXIGENCES D'INSTALLATION 17 Outils et pièces 17 Exigences d'emplacement 17 Exigences concernant l'évacuation 18 Spécifications électriques 20 INSTRUCTIONS...
... U.S.A 13 In Canada 13 Accessories 13 WARRANTY 14 TABLE DES MATIÈRES SÉCURITÉ DE LA HOTTE DE CUISINIÈRE 15 EXIGENCES D'INSTALLATION 17 Outils et pièces 17 Exigences d'emplacement 17 Exigences concernant l'évacuation 18 Spécifications électriques 20 INSTRUCTIONS...
Use & Care Guide
Page 4
... Flat-blade screwdriver ■ Metal snips ■ Phillips screwdriver ■ Metric hex key set for non-vented (recirculating) installations only. Read and follow the instructions provided with the optional recirculation kit. See "Assistance or Service" section to the Manufactured Home Construction ...30" (76.2 cm) or 36" (91.4 cm) 20" (50.8 cm) 1¹ ₂" (4.0 cm) *For non-vented (recirculating) installations **For vented installations ®†TORX and T20 are shown must be away from packages. NOTE: This product will also need : ■ 1 wall or roof cap...
... Flat-blade screwdriver ■ Metal snips ■ Phillips screwdriver ■ Metric hex key set for non-vented (recirculating) installations only. Read and follow the instructions provided with the optional recirculation kit. See "Assistance or Service" section to the Manufactured Home Construction ...30" (76.2 cm) or 36" (91.4 cm) 20" (50.8 cm) 1¹ ₂" (4.0 cm) *For non-vented (recirculating) installations **For vented installations ®†TORX and T20 are shown must be away from packages. NOTE: This product will also need : ■ 1 wall or roof cap...
Use & Care Guide
Page 5
... air turbulence that greatly reduce performance. Suggested maximum distance "X": 36" (91.4 cm) The chimneys can terminate either through the roof or wall. Vented Installations Min. ceiling height Electric cooking surface 7' 5" (2.26 m) 9' 6" (2.9 m) Gas cooking surface 7' 8" (2.34 m) 9' 6" (2.9 m) *NOTE...) or 36" (91.4 CM) Side cabinet "X" bottom of canopy to cooking surface Centerline Cooking surface *For non-vented (recirculating) installations IMPORTANT: Minimum distance "X": 24" (61.0 cm) from gas cooking . ceiling height Max. For higher ceilings, a Stainless Steel Chimney...
... air turbulence that greatly reduce performance. Suggested maximum distance "X": 36" (91.4 cm) The chimneys can terminate either through the roof or wall. Vented Installations Min. ceiling height Electric cooking surface 7' 5" (2.26 m) 9' 6" (2.9 m) Gas cooking surface 7' 8" (2.34 m) 9' 6" (2.9 m) *NOTE...) or 36" (91.4 CM) Side cabinet "X" bottom of canopy to cooking surface Centerline Cooking surface *For non-vented (recirculating) installations IMPORTANT: Minimum distance "X": 24" (61.0 cm) from gas cooking . ceiling height Max. For higher ceilings, a Stainless Steel Chimney...
Use & Care Guide
Page 6
... Road Cleveland, OH 44131-5575 ■ A 120 volt, 60 Hz., AC only, 15-amp, fused electrical circuit is adequate. Fans installed with duct tape/caulk A. Connect a section of the fan. Follow the electrical connector manufacturer's recommended procedure. Seal duct joints with existing ducts.../or fan in the non-vented (recirculating) version, using special connectors and/or tools designed and UL listed for best performance, and avoid installing the fan with duct tape/caulk A. wall cap 8 ft (2.4 m) straight Length of the system you need, add the equivalent feet ...
... Road Cleveland, OH 44131-5575 ■ A 120 volt, 60 Hz., AC only, 15-amp, fused electrical circuit is adequate. Fans installed with duct tape/caulk A. Connect a section of the fan. Follow the electrical connector manufacturer's recommended procedure. Seal duct joints with existing ducts.../or fan in the non-vented (recirculating) version, using special connectors and/or tools designed and UL listed for best performance, and avoid installing the fan with duct tape/caulk A. wall cap 8 ft (2.4 m) straight Length of the system you need, add the equivalent feet ...
Use & Care Guide
Page 7
.... Tape template in the wall for the vent system. Mark the hole locations. 3. Centerline B. Fastener locations C. Mounting height reference 4. Install the vent system before you select your hood. 1. NOTE: Do not reconnect power until the wall anchors are secure. Use caulk to ...do so can result in the hood's electrical terminal box. Complete Preparation Vertical Centerline Horizontal Line CL B REAR WALL MOUNTING TEMPLATE Installation Height ALIGN BOTTOM EDGE WITH PENCIL LINE INDICATING BOTTOM OF THE HOOD C A. Run the home power supply cable according to screw...
.... Tape template in the wall for the vent system. Mark the hole locations. 3. Centerline B. Fastener locations C. Mounting height reference 4. Install the vent system before you select your hood. 1. NOTE: Do not reconnect power until the wall anchors are secure. Use caulk to ...do so can result in the hood's electrical terminal box. Complete Preparation Vertical Centerline Horizontal Line CL B REAR WALL MOUNTING TEMPLATE Installation Height ALIGN BOTTOM EDGE WITH PENCIL LINE INDICATING BOTTOM OF THE HOOD C A. Run the home power supply cable according to screw...
Use & Care Guide
Page 8
.... 4. A B X C D E B A. Vent clamp C. Place the assembled air deflector and duct over transition piece. 2. For non-vented (recirculating) installation only: 1. Assemble the air deflector with the duct cover bracket with 2 assembly screws provided with vent clamps. 8 Mounting screws B. Vent cover bracket B. 2.9...from the bottom of the air deflector to the duct cover bracket with clamps. 3. Install (2) 5 x 45 mm lower mounting screws and tighten. A For vented installations only: 1. Install transition on back of hood (if removed for shipping) with (2) 3.5 x 9.5 mm...
.... 4. A B X C D E B A. Vent clamp C. Place the assembled air deflector and duct over transition piece. 2. For non-vented (recirculating) installation only: 1. Assemble the air deflector with the duct cover bracket with 2 assembly screws provided with vent clamps. 8 Mounting screws B. Vent cover bracket B. 2.9...from the bottom of the air deflector to the duct cover bracket with clamps. 3. Install (2) 5 x 45 mm lower mounting screws and tighten. A For vented installations only: 1. Install transition on back of hood (if removed for shipping) with (2) 3.5 x 9.5 mm...
Use & Care Guide
Page 9
... power. Lower vent cover C. 2.9 x 6.5 mm screws D. Failure to hide slots. Tighten strain relief screw. 9. NOTE: For vented installations, the upper vent cover may be reversed to do so can result in death or electrical shock. 7. Use UL listed wire connectors and connect... black wires (C) together. Failure to ceiling and install with (2) 2.9 x 6.5 mm screws. Black wires D. Install Vent Covers 1. When using both upper and lower vent covers, push lower cover down onto hood and lift...
... power. Lower vent cover C. 2.9 x 6.5 mm screws D. Failure to hide slots. Tighten strain relief screw. 9. NOTE: For vented installations, the upper vent cover may be reversed to do so can result in death or electrical shock. 7. Use UL listed wire connectors and connect... black wires (C) together. Failure to ceiling and install with (2) 2.9 x 6.5 mm screws. Black wires D. Install Vent Covers 1. When using both upper and lower vent covers, push lower cover down onto hood and lift...
Use & Care Guide
Page 11
...), 50° fluorescent light with Charcoal Filter Kit Number W10294730. Replace metal grease filter. See "Metal Grease Filter" in this section. 11 Non-Vented (recirculating) Installation Filters: The charcoal filter is inserted correctly before calling service. 1. See "Metal Grease Filter" in this section. 2. Bend spring clips away from the lens cover...
...), 50° fluorescent light with Charcoal Filter Kit Number W10294730. Replace metal grease filter. See "Metal Grease Filter" in this section. 11 Non-Vented (recirculating) Installation Filters: The charcoal filter is inserted correctly before calling service. 1. See "Metal Grease Filter" in this section. 2. Bend spring clips away from the lens cover...
Use & Care Guide
Page 13
...need further assistance, you can write to Whirlpool Corporation with : ■ Scheduling of appliances. ■ Referrals to local dealers. ■ Installation information. ■ Use and maintenance procedures. ■ Accessory and repair parts sales. ■ Specialized customer assistance (Spanish speaking, hearing ...Steel Cleaner and Polish Order Part Number 31462A Charcoal Filter Kit (for non-vented installations only) Order Part Number W10294730 Recirculation Kit (for non-vented installations only) Order Part Number W10349327 13 For further assistance If you need to order...
...need further assistance, you can write to Whirlpool Corporation with : ■ Scheduling of appliances. ■ Referrals to local dealers. ■ Installation information. ■ Use and maintenance procedures. ■ Accessory and repair parts sales. ■ Specialized customer assistance (Spanish speaking, hearing ...Steel Cleaner and Polish Order Part Number 31462A Charcoal Filter Kit (for non-vented installations only) Order Part Number W10294730 Recirculation Kit (for non-vented installations only) Order Part Number W10349327 13 For further assistance If you need to order...
Use & Care Guide
Page 14
... the United States or Canada and applies only when the major appliance is installed, operated and maintained according to instructions attached to or furnished with published user, operator or installation instructions. 2. Proof of incidental or consequential damages, so these excluded circumstances ...obtain service under these limitations and exclusions may not apply to you also may not apply to correct improper product maintenance or installation, installation not in fixtures (i.e. In the U.S. If outside the 50 United States or Canada, contact your authorized Whirlpool dealer to ...
... the United States or Canada and applies only when the major appliance is installed, operated and maintained according to instructions attached to or furnished with published user, operator or installation instructions. 2. Proof of incidental or consequential damages, so these excluded circumstances ...obtain service under these limitations and exclusions may not apply to you also may not apply to correct improper product maintenance or installation, installation not in fixtures (i.e. In the U.S. If outside the 50 United States or Canada, contact your authorized Whirlpool dealer to ...
Dimension Guide
Page 1
..., or latest edition, or with local codes. Page 1 of system = 13.0 ft (3.9 m) LOCATION REQUIREMENTS Have a qualified technician install the range hood. or 20-amp, fused electrical circuit is not recommended. NOTE: Flexible vent is required. Vent system can terminate either... Venting A Wall Venting B B A A. W10320580A 9/20/10 Specifications subject to comply with product. The hood exhaust opening is the installer's responsibility to change materials and specifications without notice. Rear discharge A 90° elbow may be away from strong draft areas, such ...
..., or latest edition, or with local codes. Page 1 of system = 13.0 ft (3.9 m) LOCATION REQUIREMENTS Have a qualified technician install the range hood. or 20-amp, fused electrical circuit is not recommended. NOTE: Flexible vent is required. Vent system can terminate either... Venting A Wall Venting B B A A. W10320580A 9/20/10 Specifications subject to comply with product. The hood exhaust opening is the installer's responsibility to change materials and specifications without notice. Rear discharge A 90° elbow may be away from strong draft areas, such ...
Dimension Guide
Page 2
... commitment to improve Dimensions are adjustable and designed to meet varying ceiling or soffit heights depending on the distance "X" between 7' 5" (2.3 m) and 9' 2" (2.8 m). For complete details, see Installation our products, we reserve the right to change without notice. Page 2 of the range hood and the cooking surface. IMPORTANT: Minimum distance "X": 24" (61.0 cm...
... commitment to improve Dimensions are adjustable and designed to meet varying ceiling or soffit heights depending on the distance "X" between 7' 5" (2.3 m) and 9' 2" (2.8 m). For complete details, see Installation our products, we reserve the right to change without notice. Page 2 of the range hood and the cooking surface. IMPORTANT: Minimum distance "X": 24" (61.0 cm...
Warranty Information
Page 1
...Whirlpool Corporation or Whirlpool Canada LP (hereafter "Whirlpool") will be addressed without service. In the event of original purchase date is installed, operated and maintained according to instructions attached to or furnished with this major appliance, you . Proof of product replacement, your ...IS COVERED WHAT IS NOT COVERED For one year from state to state or province to correct improper product maintenance or installation, installation not in materials or workmanship that existed when this major appliance was purchased. YOUR SOLE AND EXCLUSIVE REMEDY UNDER THIS ...
...Whirlpool Corporation or Whirlpool Canada LP (hereafter "Whirlpool") will be addressed without service. In the event of original purchase date is installed, operated and maintained according to instructions attached to or furnished with this major appliance, you . Proof of product replacement, your ...IS COVERED WHAT IS NOT COVERED For one year from state to state or province to correct improper product maintenance or installation, installation not in materials or workmanship that existed when this major appliance was purchased. YOUR SOLE AND EXCLUSIVE REMEDY UNDER THIS ...