SISPM1040-3166-L Datasheet
Page 1
... Watts Software Features ● Management: Web Management, SNMP V1/V2c/V3, SSH, CLI ● Port Trunk: Supports IEEE 802.3ad port trunk with link aggregation control protocol (LACP) and static trunk ● Multicast: Support IGMP Snooping V1/ V2/V3, MVR, MLD Snooping V1/V2 ● Quality of AC power supply) 15 Watts for (16) ports simultaneously 30 Watts for fast recovery ● IEEE 802.3az Energy Efficiency ● IP Source Guard, Port Security ● Port Mirroring ● Syslog ● Static Routing, 130 rates (max...
... Watts Software Features ● Management: Web Management, SNMP V1/V2c/V3, SSH, CLI ● Port Trunk: Supports IEEE 802.3ad port trunk with link aggregation control protocol (LACP) and static trunk ● Multicast: Support IGMP Snooping V1/ V2/V3, MVR, MLD Snooping V1/V2 ● Quality of AC power supply) 15 Watts for (16) ports simultaneously 30 Watts for fast recovery ● IEEE 802.3az Energy Efficiency ● IP Source Guard, Port Security ● Port Mirroring ● Syslog ● Static Routing, 130 rates (max...
Installation Guide Rev G
Page 19
..., and SNMP version 3 user-based security model (USM) Web browser upgrade HTTP/ HTTPs), TFTP, and CLI Network Time Protocol (NTP) for clock synchronization between computer systems over a WAN. Ethernet Virtual Private LAN: it is a multipoint service connecting one ENNI End Point. 33762 Rev. G https://www.lantronix.com/ Page 19 of less than 20ms on up to 250 switches. Lantronix IEEE 802.1ab (LLDP) Web GUI Interface CLI Dual Image SNMP Firmware Upgrade NTP Other Management Synchronization...
..., and SNMP version 3 user-based security model (USM) Web browser upgrade HTTP/ HTTPs), TFTP, and CLI Network Time Protocol (NTP) for clock synchronization between computer systems over a WAN. Ethernet Virtual Private LAN: it is a multipoint service connecting one ENNI End Point. 33762 Rev. G https://www.lantronix.com/ Page 19 of less than 20ms on up to 250 switches. Lantronix IEEE 802.1ab (LLDP) Web GUI Interface CLI Dual Image SNMP Firmware Upgrade NTP Other Management Synchronization...
Installation Guide Rev G
Page 38
... change the PC's IP address. 3. enter the factory default IP address to change the PC's IP address (e.g., for the first time, you will use , and in the Start Menu. 2b: Select Network and Sharing Center. 2c: Click on Change adapter settings on your Preferred and Alternate DNS server addresses. 2g: Click OK to access the switch's Web interface. 33762 Rev. Initial Switch Configuration Initial Switch Configuration via standard Ethernet LAN cable. 2. Please make sure the link status...
... change the PC's IP address. 3. enter the factory default IP address to change the PC's IP address (e.g., for the first time, you will use , and in the Start Menu. 2b: Select Network and Sharing Center. 2c: Click on Change adapter settings on your Preferred and Alternate DNS server addresses. 2g: Click OK to access the switch's Web interface. 33762 Rev. Initial Switch Configuration Initial Switch Configuration via standard Ethernet LAN cable. 2. Please make sure the link status...
Installation Guide Rev G
Page 41
... power. 1. Table 5: Troubleshooting Table Symptom SYSTEM LED is Off Possible Cause Suggested Solution The switch is related to the cable or specific port. 4. If the LED is still off, try different cable or different port, in the configuration settings via WEB user interface. Check the system log within the switch from WEB UI to understand the abnormal state (e.g., exceeding operating temperature range) and take corresponding actions to resolve. Check if the port is supplied. Check...
... power. 1. Table 5: Troubleshooting Table Symptom SYSTEM LED is Off Possible Cause Suggested Solution The switch is related to the cable or specific port. 4. If the LED is still off, try different cable or different port, in the configuration settings via WEB user interface. Check the system log within the switch from WEB UI to understand the abnormal state (e.g., exceeding operating temperature range) and take corresponding actions to resolve. Check if the port is supplied. Check...
Web User Guide Rev G PDF 14.13 MB
Page 10
... Ethernet Linear Protection Switching (EPS) ⚫ ITU-T G.8032 Ethernet Ring Protection Switching (ERPS) ⚫ DHCP Server, Relay, and Snooping configuration and statistics ⚫ IPv4/IPv6 L3 Static route ⚫ PoE features (compliant with each device. Note that this manual provides links to the Product Support webpage (logon required). Transition Networks SISPM1040-3xxx-L Web User Guide Chapter 1 - In addition to 250W/370W) ports, 4 GbE SFP ports, 2/4 GbE/10G SFP+ ports and one RJ45 Console port. For Transition Networks Drivers, Firmware...
... Ethernet Linear Protection Switching (EPS) ⚫ ITU-T G.8032 Ethernet Ring Protection Switching (ERPS) ⚫ DHCP Server, Relay, and Snooping configuration and statistics ⚫ IPv4/IPv6 L3 Static route ⚫ PoE features (compliant with each device. Note that this manual provides links to the Product Support webpage (logon required). Transition Networks SISPM1040-3xxx-L Web User Guide Chapter 1 - In addition to 250W/370W) ports, 4 GbE SFP ports, 2/4 GbE/10G SFP+ ports and one RJ45 Console port. For Transition Networks Drivers, Firmware...
Web User Guide Rev G PDF 14.13 MB
Page 34
... to be used during emergency call setup to be deleted immediately. Example: 4. Example: Office. This format consists of service. Layer 2 priority value (IEEE 802.1D-2004) 3. Voice, 2. Delete : Check to a different application type. BOX) - Layer 2 VLAN ID (IEEE 802.1Q-2003) 2. Transition Networks SISPM1040-3xxx-L Web User Guide Apartment : Unit (Apartment, suite) - Floor : Floor - Room no. : Room number - P.O. Box : Post office box (P.O. Additional code : Additional code - Improper network policy configurations are only...
... to be used during emergency call setup to be deleted immediately. Example: 4. Example: Office. This format consists of service. Layer 2 priority value (IEEE 802.1D-2004) 3. Voice, 2. Delete : Check to a different application type. BOX) - Layer 2 VLAN ID (IEEE 802.1Q-2003) 2. Transition Networks SISPM1040-3xxx-L Web User Guide Apartment : Unit (Apartment, suite) - Floor : Floor - Room no. : Room number - P.O. Box : Post office box (P.O. Additional code : Additional code - Improper network policy configurations are only...
Web User Guide Rev G PDF 14.13 MB
Page 57
...-L Web User Guide Parameter descriptions : Hash Code Contributors Source MAC Address : The Source MAC address can be used to calculate the destination port for the frame. IP Address : The IP address can be used to disable. Only one group ID is enabled. Port Members : Each switch port is listed for the frame. Buttons Apply : Click to previously saved values. Check to enable the use of the Destination MAC Address or uncheck to disable. Check to enable the use of the TCP/UDP Port Number...
...-L Web User Guide Parameter descriptions : Hash Code Contributors Source MAC Address : The Source MAC address can be used to calculate the destination port for the frame. IP Address : The IP address can be used to disable. Only one group ID is enabled. Port Members : Each switch port is listed for the frame. Buttons Apply : Click to previously saved values. Check to enable the use of the Destination MAC Address or uncheck to disable. Check to enable the use of the TCP/UDP Port Number...
Web User Guide Rev G PDF 14.13 MB
Page 243
SISPM1040-3xxx-L Web User Guide 15-1 Management 15-1.1 Account This page shows the current users, and lets you configure the switch Security settings. Currently the only way to login as another user on the web server is also a link to Add/Edit/Delete users. Figure 15-1.1: Account Configuration 2. Click Apply. This is to display the Add Account page. 3. Web Interface To add a new user via the web UI: 1. Specify the User Name parameters. 4. Parameter descriptions: User Name...
SISPM1040-3xxx-L Web User Guide 15-1 Management 15-1.1 Account This page shows the current users, and lets you configure the switch Security settings. Currently the only way to login as another user on the web server is also a link to Add/Edit/Delete users. Figure 15-1.1: Account Configuration 2. Click Apply. This is to display the Add Account page. 3. Web Interface To add a new user via the web UI: 1. Specify the User Name parameters. 4. Parameter descriptions: User Name...
Web User Guide Rev G PDF 14.13 MB
Page 390
... name. Trap Version : Indicates the SNMP supported version. Trap Community : Indicates the community access string when sending SNMP trap packet. The allowed string length is 0 to 126. Trap Destination Address : Indicates the SNMP trap destination address. SNMPv3 traps and informs using USM for authentication and privacy. Possible modes are : SNMP v1: Set SNMP supported version 1. TCP: Use TCP as the SNMP mode operation. Transition Networks SISPM1040-3xxx-L Web User Guide Trap Mode : Indicates the SNMP mode operation. but...
... name. Trap Version : Indicates the SNMP supported version. Trap Community : Indicates the community access string when sending SNMP trap packet. The allowed string length is 0 to 126. Trap Destination Address : Indicates the SNMP trap destination address. SNMPv3 traps and informs using USM for authentication and privacy. Possible modes are : SNMP v1: Set SNMP supported version 1. TCP: Use TCP as the SNMP mode operation. Transition Networks SISPM1040-3xxx-L Web User Guide Trap Mode : Indicates the SNMP mode operation. but...
Web User Guide Rev G PDF 14.13 MB
Page 455
... all devices connected to the switch using standard networking protocols such as specified by the DMS Mode selection. • The DMS Controller Switch controls syncing DMS information in reducing support time, cost, and effort. o Monitor devices' status (e.g., link up to 256 devices within four subnets. • DMS operates via an intuitive web GUI to allow you to manage Topology View, Floor View, and trap event / data polling / DHCP server assignment...
... all devices connected to the switch using standard networking protocols such as specified by the DMS Mode selection. • The DMS Controller Switch controls syncing DMS information in reducing support time, cost, and effort. o Monitor devices' status (e.g., link up to 256 devices within four subnets. • DMS operates via an intuitive web GUI to allow you to manage Topology View, Floor View, and trap event / data polling / DHCP server assignment...
CLI Reference Guide Rev G PDF 2.18 MB
Page 2
... MRP_Ring state "unknown" issue when cable removed. G 8/20/21 Fix API set port config, set port speed, change PoE mode from API if changing IP address. Transition Networks SISPM1040-3xxx-L CLI Reference Safety Warnings and Cautions These products are not intended for use or sale. Fix response from force mode, and MIB PoE Config Port PoE Mode issues. NOTE: Emphasizes important information or calls your attention to get fw upgrade status". WARNING: Alerts you to a potential...
... MRP_Ring state "unknown" issue when cable removed. G 8/20/21 Fix API set port config, set port speed, change PoE mode from API if changing IP address. Transition Networks SISPM1040-3xxx-L CLI Reference Safety Warnings and Cautions These products are not intended for use or sale. Fix response from force mode, and MIB PoE Config Port PoE Mode issues. NOTE: Emphasizes important information or calls your attention to get fw upgrade status". WARNING: Alerts you to a potential...
CLI Reference Guide Rev G PDF 2.18 MB
Page 5
.../PoE+ (support 802.3at/af, and total up to operate the SISPM1040-3248-L switch CLI. For SFP manuals see Transition Networks SFP webpage. Introduction The SISPM1040-3xxx-L switches are next-generation rack mount industrial grade Ethernet switches offering powerful L2 and basic L3 features with each device. Transition Networks SISPM1040-3xxx-L CLI Reference Chapter 1 - For Transition Networks Drivers, Firmware, etc. For Transition Networks Manuals, Brochures, Data Sheets, etc. Other related manuals are responsible for easier manageability, security and QoS...
.../PoE+ (support 802.3at/af, and total up to operate the SISPM1040-3248-L switch CLI. For SFP manuals see Transition Networks SFP webpage. Introduction The SISPM1040-3xxx-L switches are next-generation rack mount industrial grade Ethernet switches offering powerful L2 and basic L3 features with each device. Transition Networks SISPM1040-3xxx-L CLI Reference Chapter 1 - For Transition Networks Drivers, Firmware, etc. For Transition Networks Manuals, Brochures, Data Sheets, etc. Other related manuals are responsible for easier manageability, security and QoS...
CLI Reference Guide Rev G PDF 2.18 MB
Page 6
...access the CLI through either a direct serial connection to login into several modes. See the figures below : Mode exec config Config-if Config-if-vlan Config-line Config-impc-profile Config-snmp-host Config-stp-aggr Config-dhcp-pool Prompt # (config)# (config-interface)# (config-if-vlan)# (config-line)# (config-impc-profile)# (config-snmp-host)# (config-stp-aggr)# (config-dhcp-pool)# Command Function in the correct mode. To see the commands of 290 The default username and password to the device or a Telnet session. Transition Networks Chapter 2 - Users can enter. If a user...
...access the CLI through either a direct serial connection to login into several modes. See the figures below : Mode exec config Config-if Config-if-vlan Config-line Config-impc-profile Config-snmp-host Config-stp-aggr Config-dhcp-pool Prompt # (config)# (config-interface)# (config-if-vlan)# (config-line)# (config-impc-profile)# (config-snmp-host)# (config-stp-aggr)# (config-dhcp-pool)# Command Function in the correct mode. To see the commands of 290 The default username and password to the device or a Telnet session. Transition Networks Chapter 2 - Users can enter. If a user...
CLI Reference Guide Rev G PDF 2.18 MB
Page 21
... flow. Transition Networks SISPM1040-3xxx-L CLI Reference mrp-ring mvr mvrp no ntp perf-mon poe port-security privilege prompt ptp qos radius-server rapid-ring rfc2544 rmon router sflow smtp snmp-server spanning-tree svl switchport system tacacs-server traffic-test-loop udld upnp username vlan voice web y1564 MRP Ring Configuration Multicast VLAN Registration configuration Enable MVRP feature globally Negate a command or set configurable message timer on all fiber-optic ports. Enable UDLD in aggressive or normal mode and set its defaults Configure NTP Performance Monitor Power...
... flow. Transition Networks SISPM1040-3xxx-L CLI Reference mrp-ring mvr mvrp no ntp perf-mon poe port-security privilege prompt ptp qos radius-server rapid-ring rfc2544 rmon router sflow smtp snmp-server spanning-tree svl switchport system tacacs-server traffic-test-loop udld upnp username vlan voice web y1564 MRP Ring Configuration Multicast VLAN Registration configuration Enable MVRP feature globally Negate a command or set configurable message timer on all fiber-optic ports. Enable UDLD in aggressive or normal mode and set its defaults Configure NTP Performance Monitor Power...
CLI Reference Guide Rev G PDF 2.18 MB
Page 30
Syntax: default access-list rate-limiter [ ] Parameters: access-list Access list rate-limiter Rate limiter Rate limiter ID Example: SISPM1040-3248-L(config)# default access-list rate-limiter 1 SISPM1040-3248-L(config)# default access-list rate-limiter SISPM1040-3248-L(config)# SISPM1040-3xxx-L CLI Reference Command: Description: dms Enable/disable DMS Service Mode and set controller priority level. G https://www.transition.com Page 30 of 290 Transition Networks Command: default Description: Set a command to the switch using standard networking protocols such as...
Syntax: default access-list rate-limiter [ ] Parameters: access-list Access list rate-limiter Rate limiter Rate limiter ID Example: SISPM1040-3248-L(config)# default access-list rate-limiter 1 SISPM1040-3248-L(config)# default access-list rate-limiter SISPM1040-3248-L(config)# SISPM1040-3xxx-L CLI Reference Command: Description: dms Enable/disable DMS Service Mode and set controller priority level. G https://www.transition.com Page 30 of 290 Transition Networks Command: default Description: Set a command to the switch using standard networking protocols such as...
CLI Reference Guide Rev G PDF 2.18 MB
Page 72
... ipv6 logging mep non-stop-poe port-security qos sflow switchport udld voice access banner enable green-ethernet interface json loop-protect monitor ntp privilege radius-server snmp-server system upnp web access-list clock eps gvrp ip lacp mac mvr perf-mon prompt rfc2544 spanning-tree tacacs-server username y1564 SISPM1040-3xxx-L CLI Reference aggregation debug erps hostname ipmc lldp map-api-key mvrp poe ptp rmon svl traffic-test-loop vlan Command: no ? enter the command no Description: Negate a command or set its defaults from Config mode.
... ipv6 logging mep non-stop-poe port-security qos sflow switchport udld voice access banner enable green-ethernet interface json loop-protect monitor ntp privilege radius-server snmp-server system upnp web access-list clock eps gvrp ip lacp mac mvr perf-mon prompt rfc2544 spanning-tree tacacs-server username y1564 SISPM1040-3xxx-L CLI Reference aggregation debug erps hostname ipmc lldp map-api-key mvrp poe ptp rmon svl traffic-test-loop vlan Command: no ? enter the command no Description: Negate a command or set its defaults from Config mode.
CLI Reference Guide Rev G PDF 2.18 MB
Page 119
... VLAN interface configurations e.g., 1/4-9 Example: SISPM1040-3248-L(config)# interface ? * All switches or All ports GigabitEthernet 1 Gigabit Ethernet Port 10GigabitEthernet 10 Gigabit Ethernet Port llag Local link aggregation interface configuration vlan VLAN interface configurations SISPM1040-3248-L(config)# 33764 Rev. SISPM1040-3xxx-L CLI Reference Command: interface Description: Select and configure an interface. Transition Networks speed switchport udld Configures interface speed. G https://www.transition.com Page 119 of 290 Set VLAN switching mode...
... VLAN interface configurations e.g., 1/4-9 Example: SISPM1040-3248-L(config)# interface ? * All switches or All ports GigabitEthernet 1 Gigabit Ethernet Port 10GigabitEthernet 10 Gigabit Ethernet Port llag Local link aggregation interface configuration vlan VLAN interface configurations SISPM1040-3248-L(config)# 33764 Rev. SISPM1040-3xxx-L CLI Reference Command: interface Description: Select and configure an interface. Transition Networks speed switchport udld Configures interface speed. G https://www.transition.com Page 119 of 290 Set VLAN switching mode...
CLI Reference Guide Rev G PDF 2.18 MB
Page 177
... switches or All ports 1 Gigabit Ethernet Port 10 Gigabit Ethernet Port Port list for all port types Configure link monitoring Set MIB retrieval support Set Link OAM mode Active or Passive on this interface Link OAM remote loopback support Set MIB variable retrieve local info or remote info Configure frame error event thresholds and window for error frames that trigger an error-frame link event Configure frame seconds summary Enable or Disable (when the no keyword is entered) link monitor on the interface Configure window and thresholds for an error-symbol period that triggers an error...
... switches or All ports 1 Gigabit Ethernet Port 10 Gigabit Ethernet Port Port list for all port types Configure link monitoring Set MIB retrieval support Set Link OAM mode Active or Passive on this interface Link OAM remote loopback support Set MIB variable retrieve local info or remote info Configure frame error event thresholds and window for error frames that trigger an error-frame link event Configure frame seconds summary Enable or Disable (when the no keyword is entered) link monitor on the interface Configure window and thresholds for an error-symbol period that triggers an error...
API User Guide Rev C PDF 523.66 KB
Page 55
.../10G SFP+ SISPM1040-3166-L Record of firmware required: v8.40.1936. 33831 Rev. FW v8.50.0026: fix API set port config, set port speed, change PoE mode from API if changing IP address. Note: Minimum version of Revisions Rev. Transition Networks SISPM1040-3xxx-L API User Guide 50. Provide "profile selection" when in Web UI. fix API Save config issue. C https://www.transition.com Page 55 of 55 Fix Backup B 3/15/21 Config issue. Add "PoE Firmware Version" data in api...
.../10G SFP+ SISPM1040-3166-L Record of firmware required: v8.40.1936. 33831 Rev. FW v8.50.0026: fix API set port config, set port speed, change PoE mode from API if changing IP address. Note: Minimum version of Revisions Rev. Transition Networks SISPM1040-3xxx-L API User Guide 50. Provide "profile selection" when in Web UI. fix API Save config issue. C https://www.transition.com Page 55 of 55 Fix Backup B 3/15/21 Config issue. Add "PoE Firmware Version" data in api...
SISPM1040-3248-L and SISPM1040-3166-L Quick Start Guide Rev D
Page 1
... RJ45 Cable, AC Power cord (Option), four rubber feet, this manual, Rack Mount Brackets, and a secondary Power Supply (Option). 19-inch Rack Mounting: 1. Insert the module into the connector. Power Connection: Warning: Connect the power supply to the switch first, and then connect the power supply to the previously saved configuration settings). 2. LED Descriptions: The front panel LEDs display switch status. Power Supplies: 25104 Input: 85-264 VAC, 124-370 VDC; Reset Button: Press to toggle the LEDs to Factory Defaults. See the Install Guide...
... RJ45 Cable, AC Power cord (Option), four rubber feet, this manual, Rack Mount Brackets, and a secondary Power Supply (Option). 19-inch Rack Mounting: 1. Insert the module into the connector. Power Connection: Warning: Connect the power supply to the switch first, and then connect the power supply to the previously saved configuration settings). 2. LED Descriptions: The front panel LEDs display switch status. Power Supplies: 25104 Input: 85-264 VAC, 124-370 VDC; Reset Button: Press to toggle the LEDs to Factory Defaults. See the Install Guide...