Lantronix SLP - Product Brief
Page 2
...set: IEC60320/C13 to NEMA L5-20P (20A, twist lock), 8 Ft. SLPH08IIE-02 The SecureLinx SLP Expansion Chassis ('SLPX' and 'SLPY') are the property of their respective owners. Lantronix is a registered trademark, and SecureLinx is required for text-to-IP address name resolution Hardware Interfaces Network...445 cm (7.0 x 17.0 x 1.75 in) SLPV and SLPY (Zero U) - 5.715 x 4.445 x 165.10 cm (2.25 x 1.75 x 65.0 in a 8-port and 16-port models. SLPP12B08-01 SLPP12510-01 Inlet cord: IEC60320/C19 to IEC60320/C14, pk. of 8, 7 Ft. SLPV1611E-02 15353 Barranca Parkway | Irvine | CA 92618 | USA...
...set: IEC60320/C13 to NEMA L5-20P (20A, twist lock), 8 Ft. SLPH08IIE-02 The SecureLinx SLP Expansion Chassis ('SLPX' and 'SLPY') are the property of their respective owners. Lantronix is a registered trademark, and SecureLinx is required for text-to-IP address name resolution Hardware Interfaces Network...445 cm (7.0 x 17.0 x 1.75 in) SLPV and SLPY (Zero U) - 5.715 x 4.445 x 165.10 cm (2.25 x 1.75 x 65.0 in a 8-port and 16-port models. SLPP12B08-01 SLPP12510-01 Inlet cord: IEC60320/C19 to IEC60320/C14, pk. of 8, 7 Ft. SLPV1611E-02 15353 Barranca Parkway | Irvine | CA 92618 | USA...
Lantronix SLP - User Guide
Page 7
Outlet State/Control State Field Values 16 Table 3-2. SSH Command Summary 66 Table 4-3. Infeed Status Traps 72 Table 4-7. Vertical Installation 101 Table C-5-2. Web Browser Interface ...Summary 34 Table 4-1. Vertical Expansion Unit 101 Table C-5-3. Horizontal/Rack Expansion Unit 101 Table C-5-5. Temperature/Humidity Probe Technical Specifications__________ 105 SecureLinx SLP Remote Power Manager 6 SLP Hardware View 10 Figure 2-2. Operations Command Summary 34 Table 3-3. RS-232 Port 103 Table C-5-8. Physical Specifications 103 Table C-5-7. LED Description ...
Outlet State/Control State Field Values 16 Table 3-2. SSH Command Summary 66 Table 4-3. Infeed Status Traps 72 Table 4-7. Vertical Installation 101 Table C-5-2. Web Browser Interface ...Summary 34 Table 4-1. Vertical Expansion Unit 101 Table C-5-3. Horizontal/Rack Expansion Unit 101 Table C-5-5. Temperature/Humidity Probe Technical Specifications__________ 105 SecureLinx SLP Remote Power Manager 6 SLP Hardware View 10 Figure 2-2. Operations Command Summary 34 Table 3-3. RS-232 Port 103 Table C-5-8. Physical Specifications 103 Table C-5-7. LED Description ...
Lantronix SLP - User Guide
Page 8
... Load and Environment Measurement Load measurement eliminates guesswork by allowing remote control of the power on/off and reboot control of up to 16 devices or up to 16A. See Models on an expansion unit. Remote Power Management Remote control of power outlets allows individual on/...easy, practical, and secure solutions for power distribution, power management and loadmeasurement for remote equipment and branch AC circuits. 1: Introduction The Lantronix SLP Remote Power Manager family of key environmental conditions at any time from the command line or web browser interface.
... Load and Environment Measurement Load measurement eliminates guesswork by allowing remote control of the power on/off and reboot control of up to 16 devices or up to 16A. See Models on an expansion unit. Remote Power Management Remote control of power outlets allows individual on/...easy, practical, and secure solutions for power distribution, power management and loadmeasurement for remote equipment and branch AC circuits. 1: Introduction The Lantronix SLP Remote Power Manager family of key environmental conditions at any time from the command line or web browser interface.
Lantronix SLP - User Guide
Page 10
See Outlet Naming and Grouping for connection to the electrical power source. Note: Models SLP-H8 and SLP-V16 are labeled 1 through 16. Standard Accessories Mounting bracket hardware: Vertical (SLP-V, SLPY* models) - The power inlet connects to standard DB9M DTE serial port) Outlet retention clips, one per outlet (208-240V units only) ...
See Outlet Naming and Grouping for connection to the electrical power source. Note: Models SLP-H8 and SLP-V16 are labeled 1 through 16. Standard Accessories Mounting bracket hardware: Vertical (SLP-V, SLPY* models) - The power inlet connects to standard DB9M DTE serial port) Outlet retention clips, one per outlet (208-240V units only) ...
Lantronix SLP - User Guide
Page 15
... The administrator may contain up to specific outlets, groups and ports. The Control Screen is constructed of and control power to 16 characters, and are not case sensitive; Usernames and Passwords The factory default has one predefined administrative user account (username/password: ...in one of and control power to all outlets. An administrator may contain from 1-16 characters and are case sensitive. Web Browser Interface The web browser interface is SecureLinx SLP Remote Power Manager 14 3: Operations User Interfaces Two user interfaces are not allowed. ...
... The administrator may contain up to specific outlets, groups and ports. The Control Screen is constructed of and control power to 16 characters, and are not case sensitive; Usernames and Passwords The factory default has one predefined administrative user account (username/password: ...in one of and control power to all outlets. An administrator may contain from 1-16 characters and are case sensitive. Web Browser Interface The web browser interface is SecureLinx SLP Remote Power Manager 14 3: Operations User Interfaces Two user interfaces are not allowed. ...
Lantronix SLP - User Guide
Page 17
... individual outlet to be set to on , off and a Reboot action has been initiated A restart has occurred - To select a group: 1. Re-query SecureLinx SLP Remote Power Manager 16 To apply an action to individual or multiple outlets: 1. Last Control State has been maintained A power-loss has occurred - Re-query of 15 seconds...
... individual outlet to be set to on , off and a Reboot action has been initiated A restart has occurred - To select a group: 1. Re-query SecureLinx SLP Remote Power Manager 16 To apply an action to individual or multiple outlets: 1. Last Control State has been maintained A power-loss has occurred - Re-query of 15 seconds...
Lantronix SLP - User Guide
Page 39
...Type status, followed by an outlet name, and press Enter, or 2. The command displays the status of the outlet named FileServer_1: SLP: status FileServer_1 Outlet Outlet ID Name .A3 FileServer_1 Outlet State On Control State On The following command displays the on /off status ... state values, see Outlet Control on /off status of one or more than 16 total outlets, the Status command will display the first 16 outlets with this command, the status of all accessible outlets: SLP: status Outlet Outlet Control ID Name .A1 DataServer_1 .A2 WebServer_1 .A3 FileServer_1 ...
...Type status, followed by an outlet name, and press Enter, or 2. The command displays the status of the outlet named FileServer_1: SLP: status FileServer_1 Outlet Outlet ID Name .A3 FileServer_1 Outlet State On Control State On The following command displays the on /off status ... state values, see Outlet Control on /off status of one or more than 16 total outlets, the Status command will display the first 16 outlets with this command, the status of all accessible outlets: SLP: status Outlet Outlet Control ID Name .A1 DataServer_1 .A2 WebServer_1 .A3 FileServer_1 ...
Lantronix SLP - User Guide
Page 42
...Envmon command to enable and disable access for other user accounts. Example The following command displays the status of the Environmental Monitor: At the SLP: prompt, type envmon and press Enter. C Humidity Not Found 22 % RH Changing a password The Password command changes the current user...user to the Envmon command. By default, only administrative user accounts are not displayed on the screen. An administrator may contain 1-16 characters. 4. At the command prompt, type quit and press Enter, or 2. At the Enter New Password prompt type the new password and ...
...Envmon command to enable and disable access for other user accounts. Example The following command displays the status of the Environmental Monitor: At the SLP: prompt, type envmon and press Enter. C Humidity Not Found 22 % RH Changing a password The Password command changes the current user...user to the Envmon command. By default, only administrative user accounts are not displayed on the screen. An administrator may contain 1-16 characters. 4. At the command prompt, type quit and press Enter, or 2. At the Enter New Password prompt type the new password and ...
Lantronix SLP - User Guide
Page 43
... optionally followed by a username. Passwords are not displayed. Press Enter. At the command prompt, type remove user, optionally followed by a 1-16 character username (Spaces are not allowed, and usernames are not case sensitive). Press Enter. To change a password: 1. To create a user ... command. Removing a user account The Remove User command removes a user account. SecureLinx SLP Remote Power Manager 42 Example The following command creates the user account JaneDoe: SLP: create user JaneDoe Password: Verify New Password: For security, password characters are case ...
... optionally followed by a username. Passwords are not displayed. Press Enter. At the command prompt, type remove user, optionally followed by a 1-16 character username (Spaces are not allowed, and usernames are not case sensitive). Press Enter. To change a password: 1. To create a user ... command. Removing a user account The Remove User command removes a user account. SecureLinx SLP Remote Power Manager 42 Example The following command creates the user account JaneDoe: SLP: create user JaneDoe Password: Verify New Password: For security, password characters are case ...
Lantronix SLP - User Guide
Page 87
... ServerGroup_2 More [Y/es N/o]: Y Ports: Port Port ID Name Console Console TACACS+ The SLP family of necessary TACACS+ privilege levels, and users access rights for each SLP device. The SLP supports 16 different TACACS+ privilege levels; 15 are entirely configurable by a group name. At the ... followed by the system administrator (1 is reserved for default Admin level access to all access rights for an LDAP group. SecureLinx SLP Remote Power Manager 86 This enables authentication and authorization with a central TACACS+ server; User's access rights can be added, deleted...
... ServerGroup_2 More [Y/es N/o]: Y Ports: Port Port ID Name Console Console TACACS+ The SLP family of necessary TACACS+ privilege levels, and users access rights for each SLP device. The SLP supports 16 different TACACS+ privilege levels; 15 are entirely configurable by a group name. At the ... followed by the system administrator (1 is reserved for default Admin level access to all access rights for an LDAP group. SecureLinx SLP Remote Power Manager 86 This enables authentication and authorization with a central TACACS+ server; User's access rights can be added, deleted...