Lantronix xPico IAP Support and Manuals
Get Help and Manuals for this Lantronix item
This item is in your list!
View All Support Options Below
Free Lantronix xPico IAP manuals!
Problems with Lantronix xPico IAP?
Ask a Question
Free Lantronix xPico IAP manuals!
Problems with Lantronix xPico IAP?
Ask a Question
Popular Lantronix xPico IAP Manual Pages
APS: Modbus Protocol User Guide - Page 2
... check our online documentation at ftp://ftp.lantronix.com/pub to the Lantronix FTP site at www.lantronix.com/support/documentation. Reformat.
Revision History
Date June 2001 September 2002 August 2004 July 2005 September 2005 April 2012 April 2013
June 2013
Rev. Updated security settings available on IAP. Modbus Protocol User Guide
2 Windows® and Internet Explorer®...
APS: Modbus Protocol User Guide - Page 6
..., the Modbus protocol is supported on various embedded products including versions of the XPort, WiPort, xPico, and Micro/Micro125. The user guide for your IAP Device Server provides detailed information for the embedded and external products listed above.
This User Guide provides Modbus™ protocol-specific information for installing and operating the IAP Device Server using Standard...
APS: Modbus Protocol User Guide - Page 15
... more information.
The first request is the safest default setting - The delay gives ample time for more than 50 msec will not improve performance and may be transient or a hard configuration error. Modbus Protocol User Guide
15 currently never. See 4: Monitor Mode and Firmware for the RS485 slave devices to only issue one at...
APS: Modbus Protocol User Guide - Page 17
... open)
Unlike earlier versions of the Lantronix Modbus firmware that tried to hold 8 sockets open...part of idle time.
This allows a Modbus/RTU master to access up to the same IP. 255 is the minimum/maximum Modbus slave address (inclusive) to forward to configure the Device Server's security setting parameters.
7.Security Settings: SNMP Enabled
Modbus Protocol User Guide
17 Setting...
APS: Modbus Protocol User Guide - Page 20
... at www.lantronix.com/support/downloads. The TFTP method takes just a few seconds - The User Guide for more advanced features, see the error message "Sorry, this firmware is a free utility program provided by Ethernet with the error "Sorry, that discovers, configures, upgrades, and manages Lantronix Device Servers. You can download any industrial firmware to non-IAP Lantronix Device...
APS: Modbus Protocol User Guide - Page 27
... the firmware uses for each configuration option is similar to RTU Bridge Setup 1) Network/IP Settings:
IP Address 0.0.0.0/DHCP/BOOTP/AutoIP Default Gateway not set --Netmask not set (1..7) to 1) MB/TCP Exception Codes ..... Modbus/TCP header Modbus Serial Broadcasts ... Modbus/TCP to the Modbus implementation on other platforms such as the xPico-IAP and xDirect-IAP.
8: Micro125...
APS: Modbus Protocol User Guide - Page 31
..., it could take 750 msec or longer.
6. This causes the IAP Device Server firmware to automatically map this is causing the problem:
1. IAP Device Server receives the poll, but regardless, your device probably cannot accept a new poll as fast as your last response is setting the Modbus/TCP Unit ID field to actually go down...
xPico - Development Kit Quick Start - Page 2
...Lantronix warranty replacement policy, please go to our Web site at www.lantronix.com/about/contact.
A B C
Comments Initial release. Updated for the new xPico Modbus module. UNIX® is a trademark of Lantronix, Inc.
Updated for the new revision of The Open Group. xPico...offices, go to the Lantronix web site at www.lantronix.com/support/warranty. No part of the contents of...
xPico - Development Kit Quick Start - Page 3
Serial Method 6 Install DeviceInstaller 6 Assign an IP Address 7 Configure Your xPico Device 9 xPico Module 9 xPico-IAP Module 9
xPico Development Kit Quick Start
3 Table of Contents
Table of Contents 3 Introduction 4 Development Kit Contents 4 What You Need to Know 4
Hardware Address 4 IP Address 4 Connecting an xPico Module - Network Method 5 Connecting an xPico Module -
xPico - Development Kit Quick Start - Page 4
...xPico serial to use the xPico-IAP then please ensure that you have the XPC10010MS-01 or later module.
♦ xPico Module ♦ xPico Evaluation Board ♦ Two xPico Mounting Quick Clips (one installed... at www.lantronix.com/support/documentation. Introduction
Thank you for your DHCP server. Development Kit Contents
Note: The xPico Evaluation Board is available, the xPico will need ...
xPico - Development Kit Quick Start - Page 9
... various pages, then click Apply Settings, which makes the changes permanent and reboots the xPico. Click the Go icon. xPico-IAP Module
From DeviceInstaller it is easy to start the Lantronix browser-based tool, "Web Manager" to configure the xPico. Click the Connect icon. To enter Setup Mode, press Enter within 5 seconds. xPico Development Kit Quick Start
9 Commit...
xPico IAP - Product Brief - Page 1
... the easiest and fastest industrial network-enabling module on virtually any device with support of code, translating to a much lower development cost and faster time-to device data, simplifying design integration while providing robust connectivity.
xPico IAP Actual Size
24mm 16.5mm
xPico IAP Highlights:
• Chip-sized Footprint: 24mm x 16.5mm • Complete Device Server...
xPico IAP - Product Brief - Page 2
... support
* Modbus can only be operated on one serial port at a time.
> Network Interface
• Interface: Ethernet 10Base-T or 100Base-TX (Autosensing)
> Network Protocols
• TCP/IP, UDP/IP, DHCP, ARP, ICMP, DHCP, Auto-IP, DNS, SNMPv1, TFTP, Modbus TCP, ASCII, RTU
> Management and Control
• SNMP, Telnet, Serial • Field upgradable firmware...
xPico IAP - Product Brief (A4) - Page 1
....2kbps • Extended Temperature: -40° to device data, simplifying design integration while providing robust connectivity. As the smallest embedded device server in the world, xPico IAP can be utilized in designs typically intended for robust operation and with support of code, translating to a much lower development cost and faster time-to-market.
xPico IAP - Product Brief (A4) - Page 2
... +81.3.6277.8802 Email: japan_sales@lantronix.com
> Part Number
> Description
XPC10010MB-01 xPico Device Server Module, Extended Temperature,
Modbus, RoHS, Bulk
XPC10010MS-01 xPico Device Server Module, Extended Temperature, Modbus, RoHS, Sample
XPC100A001 xPico Module Mounting Quick Clip Bulk pack (50 pc)
© 2013 Lantronix, Inc. Master and
Slave mode support
* Modbus can only be...
Lantronix xPico IAP Reviews
Do you have an experience with the Lantronix xPico IAP that you would like to share?
Earn 750 points for your review!
We have not received any reviews for Lantronix yet.
Earn 750 points for your review!