Contents Installation options 39 Adjusting the door opening angle (optional accessory 41 Dimensions 42 Niche dimensions 43 Installing the appliance 45 Before you begin 45 RemoteVision module installation 47 Preparing the installation niche 48 Sliding the appliance into the installation space 52 Aligning the appliance 53 Attaching the appliance to the installation niche 54 Preparing the custom door 56 Attaching and aligning the custom door front 58 Electrical connection 62 RemoteVision (optional accessory 63
Contents Installation options 39 Adjusting the door opening angle (optional accessory 41 Dimensions 42 Niche dimensions 43 Installing the appliance 45 Before you begin 45 RemoteVision module installation 47 Preparing the installation niche 48 Sliding the appliance into the installation space 52 Aligning the appliance 53 Attaching the appliance to the installation niche 54 Preparing the custom door 56 Attaching and aligning the custom door front 58 Electrical connection 62 RemoteVision (optional accessory 63
Operating and Installation manual
Page 38
...check to be ½" (13 mm). The minimum thickness of the toe-kick panel must be sure that the installation space complies with the installation dimensions. A thickness of the installation cavity must be 5/8" (16 mm). They also need to be mounted securely to the base or the wall by ... loaded appliance is installed securely and functions properly, the base must be blocked or covered in doubt, contact Miele. The load-bearing capacity of your floor must meet the following requirements: K 18x1 Vi 996 lbs (452 kg) The air intake and outlet must not be flat, level and made of the...
...check to be ½" (13 mm). The minimum thickness of the toe-kick panel must be sure that the installation space complies with the installation dimensions. A thickness of the installation cavity must be 5/8" (16 mm). They also need to be mounted securely to the base or the wall by ... loaded appliance is installed securely and functions properly, the base must be blocked or covered in doubt, contact Miele. The load-bearing capacity of your floor must meet the following requirements: K 18x1 Vi 996 lbs (452 kg) The air intake and outlet must not be flat, level and made of the...
Operating and Installation manual
Page 40
...measurements are taken from 5/8" (16 mm) to the wall, the floor and the overhead furniture/fixtures before the appliance is available from Miele. The side panel must be individually installed within its own niche using the mounting accessories included. If there is a partition with a... not necessary). 40 Installation with partition without using the "Merging Kit" If there is a partition with a thickness of the installation space. The dimensions of the appliance is visible, a side panel must be firmly secured to 6 5/16" (160 mm) between the adjacent appliances, then each ...
...measurements are taken from 5/8" (16 mm) to the wall, the floor and the overhead furniture/fixtures before the appliance is available from Miele. The side panel must be individually installed within its own niche using the mounting accessories included. If there is a partition with a... not necessary). 40 Installation with partition without using the "Merging Kit" If there is a partition with a thickness of the installation space. The dimensions of the appliance is visible, a side panel must be firmly secured to 6 5/16" (160 mm) between the adjacent appliances, then each ...
Operating and Installation manual
Page 42
... individual kitchen. 3/8" (10 mm) K 18X1 Vi K 19X1 Vi A 32 5/8" (829 mm) 38 11/16" (982 mm) B Door front max. 1 1/2" (38 mm) Door front max. 1 1/2" (38 mm) C Door handle* Door handle* Door dimensions (open min. 115°C) *The dimensions of the door fronts and handles will vary according... to each individual kitchen. K 18X1 Vi K 19X1 Vi A B 32 5/8" (829 mm) Door front max. 1 1/2" (38 mm) 38 11/16" (982 mm...
... individual kitchen. 3/8" (10 mm) K 18X1 Vi K 19X1 Vi A 32 5/8" (829 mm) 38 11/16" (982 mm) B Door front max. 1 1/2" (38 mm) Door front max. 1 1/2" (38 mm) C Door handle* Door handle* Door dimensions (open min. 115°C) *The dimensions of the door fronts and handles will vary according... to each individual kitchen. K 18X1 Vi K 19X1 Vi A B 32 5/8" (829 mm) Door front max. 1 1/2" (38 mm) 38 11/16" (982 mm...
Operating and Installation manual
Page 46
... very heavy. Before installation ,Caution - The plinth facing must be at least 1/2" (13 mm) thick, preferably 3/4" 19 mm). ^ Check the base (see "Installation"). ^ Check the dimensions of the cavity. ^ Check that the adjacent furniture/fixtures do not collide with the installation requirements.
... very heavy. Before installation ,Caution - The plinth facing must be at least 1/2" (13 mm) thick, preferably 3/4" 19 mm). ^ Check the base (see "Installation"). ^ Check the dimensions of the cavity. ^ Check that the adjacent furniture/fixtures do not collide with the installation requirements.
Operating and Installation manual
Page 53
... (38 mm). If using a wooden beam as an alternative anti-tip device, rotate the appliance all be adjusted from the front: - Important! The guide dimension of 84" (2134 mm). Note: - The installation aids e on the appliance door have been designed for fine adjustment g ^ Use a level to a... niche height of 1 1/4" (32 mm) is related to align the installation aids e on the base has reached the indicated guide dimension 1 1/4" (32 mm). When unscrewing the height-adjustable feet, proceed gradually, alternating between left and right. - Front feet: Adjust with a level. The...
... (38 mm). If using a wooden beam as an alternative anti-tip device, rotate the appliance all be adjusted from the front: - Important! The guide dimension of 84" (2134 mm). Note: - The installation aids e on the appliance door have been designed for fine adjustment g ^ Use a level to a... niche height of 1 1/4" (32 mm) is related to align the installation aids e on the base has reached the indicated guide dimension 1 1/4" (32 mm). When unscrewing the height-adjustable feet, proceed gradually, alternating between left and right. - Front feet: Adjust with a level. The...
Side by Side Merging Kit Installation Manual
Page 4
... Tools - Piece of thin material (for the partition in model 4, note the thickness of the partition is a partition with a thickness from damage - When finding the dimensions for example, linoleum) to protect the floor from 5/8" (16 mm) to the doors if they are opened at the same time. In this case, you...
... Tools - Piece of thin material (for the partition in model 4, note the thickness of the partition is a partition with a thickness from damage - When finding the dimensions for example, linoleum) to protect the floor from 5/8" (16 mm) to the doors if they are opened at the same time. In this case, you...
Vi Refrigerators (30 inch)
Page 1
..." 29 3/4" 24" UNFARITOCANUCTSCTPEOAPMNTESL 83 1/2" - 85 3/8" E 9 1/2" Location Codes E - 5 foot - 120 Volt - 15 Amp 3-wire molded plug power supply connects lower left rear. Product and Cut-out Dimensions K1811Vi / K1801Vi 25" min.
..." 29 3/4" 24" UNFARITOCANUCTSCTPEOAPMNTESL 83 1/2" - 85 3/8" E 9 1/2" Location Codes E - 5 foot - 120 Volt - 15 Amp 3-wire molded plug power supply connects lower left rear. Product and Cut-out Dimensions K1811Vi / K1801Vi 25" min.
48-Inch Side by Side Vi Installations
Page 1
... 3/4" 24" 29 3/4" SeUeNiInTdSFivRAidOCuNCalTEsPPpTAecNCfEUilLeSSsTfOorMdetails 83 1/2" - 85 3/8" E 9 1/2" 1 1/4" Location Codes E - 5 foot - 120 Volt - 15 Amp 3-wire molded plug power supply connects lower left rear. Product and Cut-out Dimensions 48" Side by Side Combination F1411Vi & K1801Vi 25" min.
... 3/4" 24" 29 3/4" SeUeNiInTdSFivRAidOCuNCalTEsPPpTAecNCfEUilLeSSsTfOorMdetails 83 1/2" - 85 3/8" E 9 1/2" 1 1/4" Location Codes E - 5 foot - 120 Volt - 15 Amp 3-wire molded plug power supply connects lower left rear. Product and Cut-out Dimensions 48" Side by Side Combination F1411Vi & K1801Vi 25" min.