MultiSync LCD4020/4620/5220 brochure
Page 1
... display settings via mouse and keyboard. Additional screen saver functions reduce the impact of static images by long cables and low output levels of -the art calibrator and software, helps deliver accurate, consistent and repeatable color performance. Multiple calibration settings can be controlled locally or remotely. The NEC MultiSync 20 Series, featuring the 40" NEC LCD4020...
... display settings via mouse and keyboard. Additional screen saver functions reduce the impact of static images by long cables and low output levels of -the art calibrator and software, helps deliver accurate, consistent and repeatable color performance. Multiple calibration settings can be controlled locally or remotely. The NEC MultiSync 20 Series, featuring the 40" NEC LCD4020...
MultiSync LCD4020/4620/5220 brochure
Page 2
... * not available on IT models LCD4020 40" 0.648mm 1366 x 768 34.9 x 19.6 in. / 886.5 x 497.8mm LCD4620 ... Internal Speaker: None RS-232, DDC/CI Yes Yes Yes RS-232 for LCD4020/LCD4620/LCD5220 MODE L LCD MODULE Viewable Size (Diagonal) Panel Technology Native Resolution Pixel Pitch Brightness (Typical) Contrast Ratio (Typical) Active Screen Area... (without stand; Specifications for multiple monitor control, IR, DDC/CI 15W Stereo LCD4620-2-AVT LCD5220-AVT Ultra-thin bezel, advanced thermal capabilities, sealed professional panel, expansion slot, CableComp+, TileMatrix (5x5...
... * not available on IT models LCD4020 40" 0.648mm 1366 x 768 34.9 x 19.6 in. / 886.5 x 497.8mm LCD4620 ... Internal Speaker: None RS-232, DDC/CI Yes Yes Yes RS-232 for LCD4020/LCD4620/LCD5220 MODE L LCD MODULE Viewable Size (Diagonal) Panel Technology Native Resolution Pixel Pitch Brightness (Typical) Contrast Ratio (Typical) Active Screen Area... (without stand; Specifications for multiple monitor control, IR, DDC/CI 15W Stereo LCD4620-2-AVT LCD5220-AVT Ultra-thin bezel, advanced thermal capabilities, sealed professional panel, expansion slot, CableComp+, TileMatrix (5x5...
NEC DISPLAY SOLUTIONS INTRODUCES NEW THIN-BEZEL, LARGE-SCREEN LCD DISPLAYS FOR COMMERCIAL APPLICATIO
Page 1
...NEC Display Solutions (630) 542-1392 [email protected] NEC DISPLAY SOLUTIONS INTRODUCES NEW THIN-BEZEL, LARGE-SCREEN LCD DISPLAYS FOR COMMERCIAL APPLICATIONS Ultra-Thin Bezel, Future Expansion Flexibility Make the New 46-Inch MultiSync LCD4620 and 40-Inch MultiSync LCD4020 Ideal for NEC... monitors perfect for tile matrix or video-wall applications. NEC Display Solutions of America, the leading standalone provider of flat panel desktop and commercial large-screen LCD displays, plasma displays and projectors, today unveiled a new line of NEC's commercial grade-LCD and Plasma displays,...
...NEC Display Solutions (630) 542-1392 [email protected] NEC DISPLAY SOLUTIONS INTRODUCES NEW THIN-BEZEL, LARGE-SCREEN LCD DISPLAYS FOR COMMERCIAL APPLICATIONS Ultra-Thin Bezel, Future Expansion Flexibility Make the New 46-Inch MultiSync LCD4620 and 40-Inch MultiSync LCD4020 Ideal for NEC... monitors perfect for tile matrix or video-wall applications. NEC Display Solutions of America, the leading standalone provider of flat panel desktop and commercial large-screen LCD displays, plasma displays and projectors, today unveiled a new line of NEC's commercial grade-LCD and Plasma displays,...
NEC DISPLAY SOLUTIONS INTRODUCES NEW THIN-BEZEL, LARGE-SCREEN LCD DISPLAYS FOR COMMERCIAL APPLICATIO
Page 2
...ownership digital signage customers need for improved color matching • Improved CableComp - NEC's exclusive Digital Signage Technology Suite (DSTS), which allows for single or multiple monitor control • Metal back cabinet for digital signage, is incorporated into the Series...small form factor PCs, media players or additional input configurations. long cable compensation - Additional key features of the NEC MultiSync 20 Series displays include: • Increased brightness and contrast, creating improved visibility in digital signage applications, these features create a ...
...ownership digital signage customers need for improved color matching • Improved CableComp - NEC's exclusive Digital Signage Technology Suite (DSTS), which allows for single or multiple monitor control • Metal back cabinet for digital signage, is incorporated into the Series...small form factor PCs, media players or additional input configurations. long cable compensation - Additional key features of the NEC MultiSync 20 Series displays include: • Increased brightness and contrast, creating improved visibility in digital signage applications, these features create a ...
NEC DISPLAY SOLUTIONS INTRODUCES NEW THIN-BEZEL, LARGE-SCREEN LCD DISPLAYS FOR COMMERCIAL APPLICATIO
Page 3
... registered trademarks are the property of innovative LCD displays, professional grade plasmas and projectors, and integrated display solutions. The MultiSync LCD4020 and LCD4620 displays are RoHS (Restriction on the 20 Series and other NEC displays. For additional information, visit www.necdisplay.com or call 1-866-NEC-MORE, or visit www.necdisplay.com. NEC Display Solutions develops leading-edge visual technology and...
... registered trademarks are the property of innovative LCD displays, professional grade plasmas and projectors, and integrated display solutions. The MultiSync LCD4020 and LCD4620 displays are RoHS (Restriction on the 20 Series and other NEC displays. For additional information, visit www.necdisplay.com or call 1-866-NEC-MORE, or visit www.necdisplay.com. NEC Display Solutions develops leading-edge visual technology and...
LCD4020/4620/5220/6520, M40/M46 external control commands
Page 1
... null modem cable (Please refer "Using the LCD with RS-232C" on each User's manual.) 3. The packet interval needs to be longer than 600msec for a packet interval before next command is sent. Application This document defines the communications method for control of the NEC LCD monitor, MultiSync LCD4020/4620/5220/6520 and MULTEOS M40/46 when...
... null modem cable (Please refer "Using the LCD with RS-232C" on each User's manual.) 3. The packet interval needs to be longer than 600msec for a packet interval before next command is sent. Application This document defines the communications method for control of the NEC LCD monitor, MultiSync LCD4020/4620/5220/6520 and MULTEOS M40/46 when...
LCD4020/4620/5220/6520, M40/M46 external control commands
Page 2
... requests to store the adjusted value to the monitor. 4.1 Header block format (fixed length) Header...a typical procedure to control a monitor is as follows, [A controller and a monitor, two-way communication composition figure] Controller Monitor Get Parameter Delimiter Check Code Message... to get a value from the monitor that you want to get a value for future extensions. The monitor replies a current value of four parts...The controller sends command to change. The monitor replies an adjusted value. On this monitor, it must match the "Monitor ID No." Sequence of Header ASCII ...
... requests to store the adjusted value to the monitor. 4.1 Header block format (fixed length) Header...a typical procedure to control a monitor is as follows, [A controller and a monitor, two-way communication composition figure] Controller Monitor Get Parameter Delimiter Check Code Message... to get a value from the monitor that you want to get a value for future extensions. The monitor replies a current value of four parts...The controller sends command to change. The monitor replies an adjusted value. On this monitor, it must match the "Monitor ID No." Sequence of Header ASCII ...
LCD4020/4620/5220/6520, M40/M46 external control commands
Page 3
...Delimiter "Message block format" is as '1', specify a destination address 'A'(41h). ASCII 'E' (45h): Set parameter. Refer to the section 6 "Message format" for more detail. (3/40) as follows, Monitor ID 1 2 3 4 5 6 7 8 9 10 11 12 13 ALL Destination Address (ASCII) 'A'(41h) 'B'(42h) 'C'(43h) 'D'(44h) 'E'(45h) 'F'(46h) 'G'(...in the "Header". ASCII 'F' (46h): "Set parameter" reply. 6th -7th bytes) Message Length: Specify the length of the monitors which are connected by a daisy chain, specify a destination address ' '(2Ah). 4thbyte) Source: Source equipment ID. (Sender) Specify ...
...Delimiter "Message block format" is as '1', specify a destination address 'A'(41h). ASCII 'E' (45h): Set parameter. Refer to the section 6 "Message format" for more detail. (3/40) as follows, Monitor ID 1 2 3 4 5 6 7 8 9 10 11 12 13 ALL Destination Address (ASCII) 'A'(41h) 'B'(42h) 'C'(43h) 'D'(44h) 'E'(45h) 'F'(46h) 'G'(...in the "Header". ASCII 'F' (46h): "Set parameter" reply. 6th -7th bytes) Message Length: Specify the length of the monitors which are connected by a daisy chain, specify a destination address ' '(2Ah). 4thbyte) Source: Source equipment ID. (Sender) Specify ...
LCD4020/4620/5220/6520, M40/M46 external control commands
Page 4
... for more details. 2 Get Parameter reply The monitor will reply with this message for more details. 3 Set parameter The controller sends this message when you want to get , specify the "OP code page" and "OP code", refer to section 5.1 "Get current parameter from the controller. (4/40) Usually, this "command message" is as...
... for more details. 2 Get Parameter reply The monitor will reply with this message for more details. 3 Set parameter The controller sends this message when you want to get , specify the "OP code page" and "OP code", refer to section 5.1 "Get current parameter from the controller. (4/40) Usually, this "command message" is as...
LCD4020/4620/5220/6520, M40/M46 external control commands
Page 6
Operation code table". 1stbyte) STX: Start of a monitor. Ex.) The byte data 02h must be encoded to ASCII characters. OP code data must be ... Lo MSB LSB MSB LSB 1st 2nd-3rd 4th-5th 6th -7th 8th -9th 10th -13th 14th -17th 18th The monitor replies with a current value and the status of the requested item (operation code). 1stbyte) STX: Start of Message ASCII ...STX (02h) 2nd-3rdbytes) Result code. (6/40) STX OP code page OP code ETX Hi Lo Hi Lo 1st 2nd-3rd 4th-5th 6th Send this message when ...
Operation code table". 1stbyte) STX: Start of a monitor. Ex.) The byte data 02h must be encoded to ASCII characters. OP code data must be ... Lo MSB LSB MSB LSB 1st 2nd-3rd 4th-5th 6th -7th 8th -9th 10th -13th 14th -17th 18th The monitor replies with a current value and the status of the requested item (operation code). 1stbyte) STX: Start of Message ASCII ...STX (02h) 2nd-3rdbytes) Result code. (6/40) STX OP code page OP code ETX Hi Lo Hi Lo 1st 2nd-3rd 4th-5th 6th Send this message when ...
LCD4020/4620/5220/6520, M40/M46 external control commands
Page 7
... Operation code page (7/40) Ex.) The byte data 01h is encoded to ASCII characters. This returned value from the monitor is encoded to ASCII characters. This returned value from the monitor is encoded to change monitor's adjustment and so on. The controller requests a monitor to ASCII character '0'... item's OP code page. Ex.) '0','1','2' and '3' means 0123h (291) 14th -17thbytes) Current Value: (16bits) This returned value from the monitor is encoded to ASCII character '0' and '1' (30h and 31h). 10th-13thbytes) Max. Ex.) The byte data 1Ah is encoded to ASCII characters...
... Operation code page (7/40) Ex.) The byte data 01h is encoded to ASCII characters. This returned value from the monitor is encoded to ASCII characters. This returned value from the monitor is encoded to change monitor's adjustment and so on. The controller requests a monitor to ASCII character '0'... item's OP code page. Ex.) '0','1','2' and '3' means 0123h (291) 14th -17thbytes) Current Value: (16bits) This returned value from the monitor is encoded to ASCII character '0' and '1' (30h and 31h). 10th-13thbytes) Max. Ex.) The byte data 1Ah is encoded to ASCII characters...
LCD4020/4620/5220/6520, M40/M46 external control commands
Page 8
This OP code page data must be encoded to Operation code table 8th-9thbytes) Type: Operation type code (8/40) Ex.) OP code 1Ah -> OP code (Hi) = ASCII '1' (31h) OP code (Lo) = ASCII 'A' (41h) Refer to ASCII characters. Ex.) OP code 1Ah -> OP code (Hi) = ... Hi Lo 1st 2nd-3rd 4th-5th Hi Lo 6th-7th Hi Lo 8th-9th MSB LSB 10th-13th MSB LSB 14th -17th 18th The Monitor echoes back the parameter and status of the requested operation code. 1stbyte) STX: Start of Message ASCII STX (02h) 2nd-3rdbytes) Result code ASCII '0''0' (30h...
This OP code page data must be encoded to Operation code table 8th-9thbytes) Type: Operation type code (8/40) Ex.) OP code 1Ah -> OP code (Hi) = ASCII '1' (31h) OP code (Lo) = ASCII 'A' (41h) Refer to ASCII characters. Ex.) OP code 1Ah -> OP code (Hi) = ... Hi Lo 1st 2nd-3rd 4th-5th Hi Lo 6th-7th Hi Lo 8th-9th MSB LSB 10th-13th MSB LSB 14th -17th 18th The Monitor echoes back the parameter and status of the requested operation code. 1stbyte) STX: Start of Message ASCII STX (02h) 2nd-3rdbytes) Result code ASCII '0''0' (30h...
LCD4020/4620/5220/6520, M40/M46 external control commands
Page 9
...means 0123h (291) 14th -17thbytes) Requested setting Value: Echoes back the parameter for confirmation. (16bits) Reply data from the monitor is encoded to ASCII characters. ASCII: 01h-30h-41h-30h-41h-30h-34h-02h-30h-43h-03h-CHK-0Dh SOH-'0'-'A'-'0'-'A'-'0'-'4'-STX-'0'-'C'-ETX-... status byte Bit 7 = 1: Sync Frequency is encoded to ASCII characters. CR The monitor replies status as follows; ETX LSB (9/40) Refer to section 7 to report the displayed image timing. The controller requests the monitor to 10. 5.5.1 Save Current Settings. STX Command SS '4' 'E' Hi Lo...
...means 0123h (291) 14th -17thbytes) Requested setting Value: Echoes back the parameter for confirmation. (16bits) Reply data from the monitor is encoded to ASCII characters. ASCII: 01h-30h-41h-30h-41h-30h-34h-02h-30h-43h-03h-CHK-0Dh SOH-'0'-'A'-'0'-'A'-'0'-'4'-STX-'0'-'C'-ETX-... status byte Bit 7 = 1: Sync Frequency is encoded to ASCII characters. CR The monitor replies status as follows; ETX LSB (9/40) Refer to section 7 to report the displayed image timing. The controller requests the monitor to 10. 5.5.1 Save Current Settings. STX Command SS '4' 'E' Hi Lo...
LCD4020/4620/5220/6520, M40/M46 external control commands
Page 10
... packet BCC (Block Check Code) error. To tell the controller that the monitor does not have any answer to give to get a value. How to the section 4.5 "Check code" for a BCC calculation. (10/40) Bit 5-2 Reserved (Don't care) Bit 1 1:Positive Horizontal sync polarity. 0:Negative ..." command packet as follows; 01h-30h-30h-41h-41h-30h-34h-02h-42h-45h-03h-CHK-0Dh SOH-'0'-'0'-'A'-'A'-'0'-'4'-STX-'B'-'E'-ETX-CHK- Step 1. Ex.) If Monitor ID is '1', specify 'A'. '0' (30h): Message sender is the controller. 'C' (43h): Message type is "Get parameter command". '0'-'6' (30h, 36h...
... packet BCC (Block Check Code) error. To tell the controller that the monitor does not have any answer to give to get a value. How to the section 4.5 "Check code" for a BCC calculation. (10/40) Bit 5-2 Reserved (Don't care) Bit 1 1:Positive Horizontal sync polarity. 0:Negative ..." command packet as follows; 01h-30h-30h-41h-41h-30h-34h-02h-42h-45h-03h-CHK-0Dh SOH-'0'-'0'-'A'-'A'-'0'-'4'-STX-'B'-'E'-ETX-CHK- Step 1. Ex.) If Monitor ID is '1', specify 'A'. '0' (30h): Message sender is the controller. 'C' (43h): Message type is "Get parameter command". '0'-'6' (30h, 36h...
LCD4020/4620/5220/6520, M40/M46 external control commands
Page 11
... the section 4.5 "Check code" for confirmation. (11/40) Delimiter CR (0Dh): End of packet Step 3. ETX (03h): End of Message Check code BCC: Block Check Code Refer to the section 4.5 "Check code" for a BCC calculation. Delimiter CR (0Dh): End of packet Step 2. Ex.) If Monitor ID is '1', specify 'A'. '0' (30h): Message sender is...
... the section 4.5 "Check code" for confirmation. (11/40) Delimiter CR (0Dh): End of packet Step 3. ETX (03h): End of Message Check code BCC: Block Check Code Refer to the section 4.5 "Check code" for a BCC calculation. Delimiter CR (0Dh): End of packet Step 2. Ex.) If Monitor ID is '1', specify 'A'. '0' (30h): Message sender is...
LCD4020/4620/5220/6520, M40/M46 external control commands
Page 12
...-'0'-Monitor ID-'0'-'E'-'0'-'A' STX-'0'-'2'-'7'-'8'-'0'-'0'-'0'-'1'-ETX Check code BCC Delimiter CR (12/40) Message STX (02h): Start of packet 6.2. ETX (03h): End of Message '0'-'C' (30h, 43h): Command code is 0Ch as "Save current settings". Message STX (02h): Start of Message Check code BCC: Block Check Code Refer to check the Brightness setting. (Recommended) Step 5. MultiSync LCD4020...
...-'0'-Monitor ID-'0'-'E'-'0'-'A' STX-'0'-'2'-'7'-'8'-'0'-'0'-'0'-'1'-ETX Check code BCC Delimiter CR (12/40) Message STX (02h): Start of packet 6.2. ETX (03h): End of Message '0'-'C' (30h, 43h): Command code is 0Ch as "Save current settings". Message STX (02h): Start of Message Check code BCC: Block Check Code Refer to check the Brightness setting. (Recommended) Step 5. MultiSync LCD4020...
LCD4020/4620/5220/6520, M40/M46 external control commands
Page 13
... BCC: Block Check Code Refer to get a value. Header SOH-'0'-Monitor ID-'0'-'C'-'0'-'6' Header Message Check code STX-'0'-'2'-'7'-'9'-ETX BCC Delimiter CR (13/40) Header SOH (01h): Start of Header '0' (30h): Reserved Monitor ID: Specify the Monitor ID which you want to the section 4.5 "Check code" for ...a BCC calculation. Ex.) When this byte is set to 'A', the replying Monitor ID is '1'. 'F' (46h):...
... BCC: Block Check Code Refer to get a value. Header SOH-'0'-Monitor ID-'0'-'C'-'0'-'6' Header Message Check code STX-'0'-'2'-'7'-'9'-ETX BCC Delimiter CR (13/40) Header SOH (01h): Start of Header '0' (30h): Reserved Monitor ID: Specify the Monitor ID which you want to the section 4.5 "Check code" for ...a BCC calculation. Ex.) When this byte is set to 'A', the replying Monitor ID is '1'. 'F' (46h):...
LCD4020/4620/5220/6520, M40/M46 external control commands
Page 14
...Get parameter". '0'-'6' (30h, 36h): Message length is 2's complement. ETX (03h): End of Header '0' (30h): Reserved Monitor ID: Specify the Monitor ID which you want to get a value. Delimiter CR Message STX (02h): Start of packet Step 4. Delimiter CR (...0Dh): End of Message '0'-'0' (30h, 30h): Result code. Header Message Check code SOH-'0'-'0'-Monitor ID-'D'-'1'-'2' STX-'0'-'0'-'0'-'2'-'7'-'9'-'0'-'0' BCC -'F'-'F'-'F'-'F'-'0'-'0'-'3'-'2'-ETX Header SOH (01h): Start of packet (14/40) Readout value is 6 bytes. Delimiter CR (0Dh): End of Header '0' (30h): Reserved...
...Get parameter". '0'-'6' (30h, 36h): Message length is 2's complement. ETX (03h): End of Header '0' (30h): Reserved Monitor ID: Specify the Monitor ID which you want to get a value. Delimiter CR Message STX (02h): Start of packet Step 4. Delimiter CR (...0Dh): End of Message '0'-'0' (30h, 30h): Result code. Header Message Check code SOH-'0'-'0'-Monitor ID-'D'-'1'-'2' STX-'0'-'0'-'0'-'2'-'7'-'9'-'0'-'0' BCC -'F'-'F'-'F'-'F'-'0'-'0'-'3'-'2'-ETX Header SOH (01h): Start of packet (14/40) Readout value is 6 bytes. Delimiter CR (0Dh): End of Header '0' (30h): Reserved...
LCD4020/4620/5220/6520, M40/M46 external control commands
Page 15
...monitor returns with the current power status. Delimiter CR (0Dh): End of Message '0'-'1'-'D'-'6': Get power status command. Message STX(02h):Start of Message '0'-'2' (30h, 32h): Reserved data '0'-'0' (30h, 30h): Result code 00: No Error. 01: Unsupported. 'D'-'6'(44h, 36h): Display...calculation. Ex.) If Monitor ID is '1', specify 'A'. '0' (30h): Message sender is the controller. 'A' (41h): Message Type is "Command". '0'-'6' (30h, 36h): Message length is the controller. Delimiter (15/40) Header SOH-'0'-'0'-Monitor ID-'B'-'1'-'2' Message STX...
...monitor returns with the current power status. Delimiter CR (0Dh): End of Message '0'-'1'-'D'-'6': Get power status command. Message STX(02h):Start of Message '0'-'2' (30h, 32h): Reserved data '0'-'0' (30h, 30h): Result code 00: No Error. 01: Unsupported. 'D'-'6'(44h, 36h): Display...calculation. Ex.) If Monitor ID is '1', specify 'A'. '0' (30h): Message sender is the controller. 'A' (41h): Message Type is "Command". '0'-'6' (30h, 36h): Message length is the controller. Delimiter (15/40) Header SOH-'0'-'0'-Monitor ID-'B'-'1'-'2' Message STX...
LCD4020/4620/5220/6520, M40/M46 external control commands
Page 16
... CR (0Dh): End of Message Check code BCC: Block Check Code Refer to the monitor at a time is the controller. Message STX (02h): Start of Message Check code BCC: Block Check Code (16/40) No error. 'C'-'2','0'-'3'-'D'-'6' (43h, 32h, 30h, 33h, 44h, 36h): power control ...reply command The monitor replies same as power control command to the controller. '0'-'0'-'0'-'1' (30h, 30h, 30h, 31h): Power...
... CR (0Dh): End of Message Check code BCC: Block Check Code Refer to the monitor at a time is the controller. Message STX (02h): Start of Message Check code BCC: Block Check Code (16/40) No error. 'C'-'2','0'-'3'-'D'-'6' (43h, 32h, 30h, 33h, 44h, 36h): power control ...reply command The monitor replies same as power control command to the controller. '0'-'0'-'0'-'1' (30h, 30h, 30h, 31h): Power...