Mini Split Catalog
Page 4
... available. Air Conditioners and Heat Pumps Line-Up Your Best Choice in Mini Split Air Conditioning and Heat Pump Systems Since 1983, Panasonic Mini Split Air Conditioner and Heat Pump products offer a wide range of versatile solutions for cooling and heating requirements for single or multiple rooms. The indoor unit (evaporator) is simple, fast and efficient. Model Chart HEAT PUMP MODELS Btu/h 9,000 MODEL (System) XE12SKUA E9RKUA RE9SKUA E9SD3UAW* NEW EXTERIOS Wall Mounted EXTERIOS CS-XE9SKUA CU-XE9SKUA Wall Mounted CS-E9RKUA CU-E9RKUA NEW Wall Mounted CS-RE9SKUA CU...
... available. Air Conditioners and Heat Pumps Line-Up Your Best Choice in Mini Split Air Conditioning and Heat Pump Systems Since 1983, Panasonic Mini Split Air Conditioner and Heat Pump products offer a wide range of versatile solutions for cooling and heating requirements for single or multiple rooms. The indoor unit (evaporator) is simple, fast and efficient. Model Chart HEAT PUMP MODELS Btu/h 9,000 MODEL (System) XE12SKUA E9RKUA RE9SKUA E9SD3UAW* NEW EXTERIOS Wall Mounted EXTERIOS CS-XE9SKUA CU-XE9SKUA Wall Mounted CS-E9RKUA CU-E9RKUA NEW Wall Mounted CS-RE9SKUA CU...
Mini Split Catalog
Page 5
...,000 CS-E12RB4UW CS-E18RB4UW 37,800 Outdoor Unit Outdoor CU-2E18NBU 5E Series Btu/h 7,000 9,000 12,000 Wall Mounted 4-Way Cassette 24" x 24" Btu/h CS-ME7RKUA/CS-E9RKUAW/ CS-E12RKUAW CS-E12RB4UW 18,000 24,000 CS-E18RKUAW/ CS-E24RKUAW CS-E18RB4UW CU-3E19RBU COOLING ONLY MODELS / LOW AMBIENT TYPE Btu/h MODEL (System) 30,000 KS30NKUA CU-4E24RBU 36,000 KS36NKUA Low Ambient Type AIR CONDITIONER Wall Mounted CS-KS30NKU CU-KS30NKUA CS-KS36NKU CU-KS36NKUA HEAT PUMP Indoor Unit Outdoor Unit Outdoor CU...
...,000 CS-E12RB4UW CS-E18RB4UW 37,800 Outdoor Unit Outdoor CU-2E18NBU 5E Series Btu/h 7,000 9,000 12,000 Wall Mounted 4-Way Cassette 24" x 24" Btu/h CS-ME7RKUA/CS-E9RKUAW/ CS-E12RKUAW CS-E12RB4UW 18,000 24,000 CS-E18RKUAW/ CS-E24RKUAW CS-E18RB4UW CU-3E19RBU COOLING ONLY MODELS / LOW AMBIENT TYPE Btu/h MODEL (System) 30,000 KS30NKUA CU-4E24RBU 36,000 KS36NKUA Low Ambient Type AIR CONDITIONER Wall Mounted CS-KS30NKU CU-KS30NKUA CS-KS36NKU CU-KS36NKUA HEAT PUMP Indoor Unit Outdoor Unit Outdoor CU...
Mini Split Catalog
Page 7
.... Microprocessor-Controlled Operation Microprocessor control ensures that air is higher than the set : temperature, sweep (louver control), fan speeds, timer and more energy savings. Dry Mode By coupling compressor and fan operation, intermittent operation can take a beating from exposure to diagnose malfunctions, greatly reducing service labor (Wired remote controller). (Example of the indoor unit. Electric Refrigerant Control Valve The circulation volume of mold and mildew, and helps create clean air. Wireless Remote Control Panasonic's infrared Remote Control with an...
.... Microprocessor-Controlled Operation Microprocessor control ensures that air is higher than the set : temperature, sweep (louver control), fan speeds, timer and more energy savings. Dry Mode By coupling compressor and fan operation, intermittent operation can take a beating from exposure to diagnose malfunctions, greatly reducing service labor (Wired remote controller). (Example of the indoor unit. Electric Refrigerant Control Valve The circulation volume of mold and mildew, and helps create clean air. Wireless Remote Control Panasonic's infrared Remote Control with an...
Mini Split Catalog
Page 8
... control with higher cooling/heating power during the start-up period to cool/heat the room faster than non-inverter models. This keeps everyone comfortable while saving energy. Quick Cooling and Heating Panasonic Inverter air conditioners can operate with a wide power output range enables an inverter air conditioner to meet different room occupancy levels, providing constant comfort. Wider Output Power Range Maximum capacity 12,000Btu/h Rated capacity 8,700Btu/h Minimum capacity 2,800Btu/h What's ECONAVI? Reduces Electricity Consumption Panasonic inverter air conditioners/heat pumps...
... control with higher cooling/heating power during the start-up period to cool/heat the room faster than non-inverter models. This keeps everyone comfortable while saving energy. Quick Cooling and Heating Panasonic Inverter air conditioners can operate with a wide power output range enables an inverter air conditioner to meet different room occupancy levels, providing constant comfort. Wider Output Power Range Maximum capacity 12,000Btu/h Rated capacity 8,700Btu/h Minimum capacity 2,800Btu/h What's ECONAVI? Reduces Electricity Consumption Panasonic inverter air conditioners/heat pumps...
Mini Split Catalog
Page 10
Performance & Electrical Ratings Capacity Cooling Btu/h Heating Btu/h Moisture Removal High Pints/H Dry Air Flow High CFM SEER Cooling EER Cooling HSPF Heating Power Supply V, Phase, Hz Running Amps Cooling A Heating A Power Input Cooling W Heating W Back-up Heater kW Fuse or Circuit Breaker Capacity A Features Controls Low Ambient Control Wireless Remote Controller Wired Remote Controller (optional) Fan Speeds Timer Air Deflection Horizontal Vertical Air Filter Refrigerant Refrigerant control Operation Sound In(Hi / Lo/ Q-Lo) dB-A Outdoor(Hi)...
Performance & Electrical Ratings Capacity Cooling Btu/h Heating Btu/h Moisture Removal High Pints/H Dry Air Flow High CFM SEER Cooling EER Cooling HSPF Heating Power Supply V, Phase, Hz Running Amps Cooling A Heating A Power Input Cooling W Heating W Back-up Heater kW Fuse or Circuit Breaker Capacity A Features Controls Low Ambient Control Wireless Remote Controller Wired Remote Controller (optional) Fan Speeds Timer Air Deflection Horizontal Vertical Air Filter Refrigerant Refrigerant control Operation Sound In(Hi / Lo/ Q-Lo) dB-A Outdoor(Hi)...
Mini Split Catalog
Page 12
... Unit CU-E9RKUA Indoor Unit CS-E12RKUA Outdoor Unit CU-E12RKUA Performance & Electrical Ratings Capacity Cooling Btu/h HeatingBtu/h Moisture Removal High Pints/H Dry Air Flow HighCFM SEER Cooling EER Cooling HSPF Heating Power Supply V, Phase, Hz Running Amps CoolingA HeatingA Power Input CoolingW HeatingW Back-up Heater kW Fuse or Circuit Breaker Capacity A Features Controls Low Ambient Control Wireless Controller Wired Remote Controller(optional) Fan Speeds Timer Air Deflection Horizontal Vertical Air Filter Refrigerant Refrigerant control...
... Unit CU-E9RKUA Indoor Unit CS-E12RKUA Outdoor Unit CU-E12RKUA Performance & Electrical Ratings Capacity Cooling Btu/h HeatingBtu/h Moisture Removal High Pints/H Dry Air Flow HighCFM SEER Cooling EER Cooling HSPF Heating Power Supply V, Phase, Hz Running Amps CoolingA HeatingA Power Input CoolingW HeatingW Back-up Heater kW Fuse or Circuit Breaker Capacity A Features Controls Low Ambient Control Wireless Controller Wired Remote Controller(optional) Fan Speeds Timer Air Deflection Horizontal Vertical Air Filter Refrigerant Refrigerant control...
Mini Split Catalog
Page 13
... Wired Remote Controller(optional) N/A N/A Fan Speeds Timer Air Deflection Air Filter Refrigerant Refrigerant control Operation Sound Refrigerant Piping Refrigerant Pipe Length Elevation Difference* Dimensions & Weight Height Width Depth Net Weight Horizontal Vertical In(Hi / Me / Lo/ Qt) dB-A Outdoor(Hi)dB-A Type Dischargeinches Suctioninches Ft. Performance & Electrical Ratings Capacity Cooling Btu/h HeatingBtu/h Moisture Removal High Pints/H Dry Air Flow HighCFM SEER Cooling EER Cooling HSPF Heating Power Supply V, Phase, Hz Running Amps Cooling...
... Wired Remote Controller(optional) N/A N/A Fan Speeds Timer Air Deflection Air Filter Refrigerant Refrigerant control Operation Sound Refrigerant Piping Refrigerant Pipe Length Elevation Difference* Dimensions & Weight Height Width Depth Net Weight Horizontal Vertical In(Hi / Me / Lo/ Qt) dB-A Outdoor(Hi)dB-A Type Dischargeinches Suctioninches Ft. Performance & Electrical Ratings Capacity Cooling Btu/h HeatingBtu/h Moisture Removal High Pints/H Dry Air Flow HighCFM SEER Cooling EER Cooling HSPF Heating Power Supply V, Phase, Hz Running Amps Cooling...
Mini Split Catalog
Page 14
... & Electrical Ratings Capacity Cooling Btu/h HeatingBtu/h Moisture Removal High Pints/H Dry Air Flow Hi / Med / Low CFM SEER Cooling EER Cooling HSPF Heating Power Supply V, Phase, Hz Running Amps CoolingA HeatingA Power Input CoolingW HeatingW Back-up Heater kW Fuse or Circuit Breaker Capacity A Features Controls Low Ambient Control Wireless Remote Controller Wired Remote Controller (optional) Fan Speeds Timer Air Deflection Horizontal Vertical Air Filter Refrigerant Refrigerant control Operation Sound In (Hi / Me / Lo / Qt) dB-A Outdoor...
... & Electrical Ratings Capacity Cooling Btu/h HeatingBtu/h Moisture Removal High Pints/H Dry Air Flow Hi / Med / Low CFM SEER Cooling EER Cooling HSPF Heating Power Supply V, Phase, Hz Running Amps CoolingA HeatingA Power Input CoolingW HeatingW Back-up Heater kW Fuse or Circuit Breaker Capacity A Features Controls Low Ambient Control Wireless Remote Controller Wired Remote Controller (optional) Fan Speeds Timer Air Deflection Horizontal Vertical Air Filter Refrigerant Refrigerant control Operation Sound In (Hi / Me / Lo / Qt) dB-A Outdoor...
Mini Split Catalog
Page 15
... & Electrical Ratings Capacity Cooling Btu/h HeatingBtu/h Moisture Removal High Pints/H Dry Air Flow Hi / Med / Low CFM SEER Cooling EER Cooling HSPF Heating Power Supply V, Phase, Hz Running Amps CoolingA HeatingA Power Input CoolingW HeatingW Back-up Heater kW Fuse or Circuit Breaker Capacity A Features Controls Low Ambient Control Wireless Remote Controller Wired Remote Controller (optional) Fan Speeds Timer Air Deflection Horizontal Vertical Air Filter Refrigerant Refrigerant control Operation Sound In (Hi / Me / Lo / Qt) dB-A Outdoor...
... & Electrical Ratings Capacity Cooling Btu/h HeatingBtu/h Moisture Removal High Pints/H Dry Air Flow Hi / Med / Low CFM SEER Cooling EER Cooling HSPF Heating Power Supply V, Phase, Hz Running Amps CoolingA HeatingA Power Input CoolingW HeatingW Back-up Heater kW Fuse or Circuit Breaker Capacity A Features Controls Low Ambient Control Wireless Remote Controller Wired Remote Controller (optional) Fan Speeds Timer Air Deflection Horizontal Vertical Air Filter Refrigerant Refrigerant control Operation Sound In (Hi / Me / Lo / Qt) dB-A Outdoor...
Mini Split Catalog
Page 16
... CS-ME5RKUA / CS-ME7RKUA CS-E12RB4UW Wireless Remote Controller "Included" with each indoor Wired Remote Controller (CZ-RD516C-1) (Optional) Indoor Unit: Wall Mounted Type Model No. RAC Multi-System Indoor Units The multi-system type allows a single outdoor unit to be connected to the table on the P.34 in the catalog for more detail.) 15 ECONAVI Room Freeze Protection Microprocessor Control Wireless Controller Wired Controller Self Diagnose Dry 5 Fan speeds Air Sweep Louver Autochange over Night setback Hot Start 24hr timer...
... CS-ME5RKUA / CS-ME7RKUA CS-E12RB4UW Wireless Remote Controller "Included" with each indoor Wired Remote Controller (CZ-RD516C-1) (Optional) Indoor Unit: Wall Mounted Type Model No. RAC Multi-System Indoor Units The multi-system type allows a single outdoor unit to be connected to the table on the P.34 in the catalog for more detail.) 15 ECONAVI Room Freeze Protection Microprocessor Control Wireless Controller Wired Controller Self Diagnose Dry 5 Fan speeds Air Sweep Louver Autochange over Night setback Hot Start 24hr timer...
Mini Split Catalog
Page 19
... Units SEER Cooling EER Cooling HSPF Heating Electrical Rating Power Supply V, Phase, Hz Running Ampere A Power Input W Maximum Fuse Size Amps Features Controls Fan Speeds Compressor Refrigerant / Amount Charged at Shipment Refrigerant Control Operation Sound HidB-A Refrigerant Tubing Connections Type Max. RAC Multi-System Outdoor Units 4E Series Connectable from 2 to 4 Indoor Units RAC Multi System 4 Up to the compressor may cause a malfunction. * Test Conditions based on AHRI 210/240 1hr off timer Weekly Timer System Controller Filter sign Auto...
... Units SEER Cooling EER Cooling HSPF Heating Electrical Rating Power Supply V, Phase, Hz Running Ampere A Power Input W Maximum Fuse Size Amps Features Controls Fan Speeds Compressor Refrigerant / Amount Charged at Shipment Refrigerant Control Operation Sound HidB-A Refrigerant Tubing Connections Type Max. RAC Multi-System Outdoor Units 4E Series Connectable from 2 to 4 Indoor Units RAC Multi System 4 Up to the compressor may cause a malfunction. * Test Conditions based on AHRI 210/240 1hr off timer Weekly Timer System Controller Filter sign Auto...
Mini Split Catalog
Page 20
..." 42-5/32" 9-15/32" 26.0 Air Sweep Louver Autochange over Night setback Hot Start 24hr timer Performance & Electrical Ratings Capacity Moisture Removal Dry Air Flow Power Supply Running Amps Power Input Operation Sound [Hi / Me / Lo / Q-Lo ] Elevation Difference* Refrigerant Tube Diameter Adapters Required Dimensions & Weight Height Width Depth Net Weight Cooling Btu/h HeatingBtu/h High Pints/H HighCFM V, Phase, Hz CoolingA HeatingA CoolingW HeatingW Cooling Heating Outdoor Above ft Outdoor Below ft Dischargeinches Suctioninches...
..." 42-5/32" 9-15/32" 26.0 Air Sweep Louver Autochange over Night setback Hot Start 24hr timer Performance & Electrical Ratings Capacity Moisture Removal Dry Air Flow Power Supply Running Amps Power Input Operation Sound [Hi / Me / Lo / Q-Lo ] Elevation Difference* Refrigerant Tube Diameter Adapters Required Dimensions & Weight Height Width Depth Net Weight Cooling Btu/h HeatingBtu/h High Pints/H HighCFM V, Phase, Hz CoolingA HeatingA CoolingW HeatingW Cooling Heating Outdoor Above ft Outdoor Below ft Dischargeinches Suctioninches...
Mini Split Catalog
Page 21
... timer Weekly Timer System Controller Filter sign Auto Restart Fresh Air intake Branch Extension Drain Pump Low Ambient Operation Elect.Valve ODP=0 Refrigerant Quiet Antimicrobial Filt. 20 Blue Fin RAC Multi-System Heat Pump CS-ME5RKUA / CS-ME7RKUA / CS-E9RKUAW / CS-E12RKUAW RAC Multi System CS-E18RKUAW / CS-E18RB4U / CS-E24RKUAW Wireless Remote Controller (Standard) (optional) Tubing Length Wired Remote Controller CZ-RD516C-1 (Optional) CU-5E36QBU CS-E12RB4U / CS-E18RB4U Wireless Remote Controller (Included) Specifications Wired Remote Controller (Optional) Outdoor...
... timer Weekly Timer System Controller Filter sign Auto Restart Fresh Air intake Branch Extension Drain Pump Low Ambient Operation Elect.Valve ODP=0 Refrigerant Quiet Antimicrobial Filt. 20 Blue Fin RAC Multi-System Heat Pump CS-ME5RKUA / CS-ME7RKUA / CS-E9RKUAW / CS-E12RKUAW RAC Multi System CS-E18RKUAW / CS-E18RB4U / CS-E24RKUAW Wireless Remote Controller (Standard) (optional) Tubing Length Wired Remote Controller CZ-RD516C-1 (Optional) CU-5E36QBU CS-E12RB4U / CS-E18RB4U Wireless Remote Controller (Included) Specifications Wired Remote Controller (Optional) Outdoor...
Mini Split Catalog
Page 25
... set to F5 in any operation mode (heat F1 pump type only). Outdoor Below Ft. Wind direction is a standard feature which provides optimum airflow during heating or cooling operation. Performance & Electrical Ratings Capacity Cooling Btu/h HeatingBtu/h Moisture Removal High Pints/H Dry Air Flow Hi / Med / Low CFM SEER Cooling EER Cooling HSPF Heating Power Supply V, Phase, Hz Running Amps CoolingA HeatingA Power Input CoolingW HeatingW Fuse or Circuit Breaker Capacity A Features Controls Low Ambient Control (for heating or cooling. Indoor Unit...
... set to F5 in any operation mode (heat F1 pump type only). Outdoor Below Ft. Wind direction is a standard feature which provides optimum airflow during heating or cooling operation. Performance & Electrical Ratings Capacity Cooling Btu/h HeatingBtu/h Moisture Removal High Pints/H Dry Air Flow Hi / Med / Low CFM SEER Cooling EER Cooling HSPF Heating Power Supply V, Phase, Hz Running Amps CoolingA HeatingA Power Input CoolingW HeatingW Fuse or Circuit Breaker Capacity A Features Controls Low Ambient Control (for heating or cooling. Indoor Unit...
Mini Split Catalog
Page 26
Wireless Remote Controller (Included) Wired Remote Controller CZ-RD52CU Outdoor Unit CU-E12RB4U Outdoor Unit CU-E18RB4U CZ-CENSC1 Econavi Sensor (Optional) CZ-RTC4 Standard Wired Remote Controller (Optional) CZ-RTC5 High-spec Wired Remote Controller (Optional) Outdoor Unit U-26PE1U6 U-36PE1U6 Outdoor Unit U-42PE1U6 (Heat Pump) (Heat Pump) (optional) (optional) Integrated Drain Pump Drain pump is returned through the center of the grille, while evenly distributing air through each of drain water 4-way Recessed Air Conditioners & Heat Pumps Whisper-Quiet Operation Thanks to...
Wireless Remote Controller (Included) Wired Remote Controller CZ-RD52CU Outdoor Unit CU-E12RB4U Outdoor Unit CU-E18RB4U CZ-CENSC1 Econavi Sensor (Optional) CZ-RTC4 Standard Wired Remote Controller (Optional) CZ-RTC5 High-spec Wired Remote Controller (Optional) Outdoor Unit U-26PE1U6 U-36PE1U6 Outdoor Unit U-42PE1U6 (Heat Pump) (Heat Pump) (optional) (optional) Integrated Drain Pump Drain pump is returned through the center of the grille, while evenly distributing air through each of drain water 4-way Recessed Air Conditioners & Heat Pumps Whisper-Quiet Operation Thanks to...
Mini Split Catalog
Page 27
... Air Conditioners & Heat Pumps 4-Way Cassette 36" x 36" Heat Pumps Model No. Unit Model No. Grille Assembly Performance & Electrical Ratings Capacity Cooling Btu/h HeatingBtu/h Moisture Removal High Pints/H Dry Air Flow Hi / Med / Low CFM SEER Cooling EER Cooling HSPF Heating Power Supply V, Phase, Hz Running Amps CoolingA HeatingA Power Input CoolingW HeatingW Fuse or Circuit Breaker Capacity A Features Controls Low Ambient Control (for Cooling) Wireless Remote Controller Wired Remote Controller (optional) Fan Speeds Air Deflection Air Filter...
... Air Conditioners & Heat Pumps 4-Way Cassette 36" x 36" Heat Pumps Model No. Unit Model No. Grille Assembly Performance & Electrical Ratings Capacity Cooling Btu/h HeatingBtu/h Moisture Removal High Pints/H Dry Air Flow Hi / Med / Low CFM SEER Cooling EER Cooling HSPF Heating Power Supply V, Phase, Hz Running Amps CoolingA HeatingA Power Input CoolingW HeatingW Fuse or Circuit Breaker Capacity A Features Controls Low Ambient Control (for Cooling) Wireless Remote Controller Wired Remote Controller (optional) Fan Speeds Air Deflection Air Filter...
Mini Split Catalog
Page 28
... & Electrical Ratings Capacity Moisture Removal Dry Air Flow SEER EER HSPF Power Supply Running Amps Power Input External Static Pressure Fuse or Circuit Breaker Capacity Features Controls Low Ambient Control Wireless Remote Controller (optional) Wired Remote Controller (optional) Fan Speeds Timer Air Deflection Air Filter Refrigerant Control Operation Sound Refrigerant Piping Refrigerant Pipe Length Elevation Difference** Dimensions & Weight Height Width Depth Net Weight CoolingBtu/h HeatingBtu/h HighPints/H Hi / Med / LowCFM Cooling Cooling Heating V, Phase, Hz CoolingA Heating...
... & Electrical Ratings Capacity Moisture Removal Dry Air Flow SEER EER HSPF Power Supply Running Amps Power Input External Static Pressure Fuse or Circuit Breaker Capacity Features Controls Low Ambient Control Wireless Remote Controller (optional) Wired Remote Controller (optional) Fan Speeds Timer Air Deflection Air Filter Refrigerant Control Operation Sound Refrigerant Piping Refrigerant Pipe Length Elevation Difference** Dimensions & Weight Height Width Depth Net Weight CoolingBtu/h HeatingBtu/h HighPints/H Hi / Med / LowCFM Cooling Cooling Heating V, Phase, Hz CoolingA Heating...
Mini Split Catalog
Page 30
... (High Spec) CZ-64ESMC1U Key Features (Standard Remote/7 Day Timer): • Thin and Easy To Read • Simple To Install and Use • Can Be Adapted for Use On All Indoor Units • Fan Speed Control • Airflow Direction • Operating Mode (Heating/Cooling/Auto/Dry/Fan) • Vacation Mode for All Connected Wired Remotes Wireless Remote Controller Applicable Unit U2-series (4-Way Cassette) Built-in type • Signal receiving unit can be installed in the inside indoor unit. The Air Conditioning Gateway.
... (High Spec) CZ-64ESMC1U Key Features (Standard Remote/7 Day Timer): • Thin and Easy To Read • Simple To Install and Use • Can Be Adapted for Use On All Indoor Units • Fan Speed Control • Airflow Direction • Operating Mode (Heating/Cooling/Auto/Dry/Fan) • Vacation Mode for All Connected Wired Remotes Wireless Remote Controller Applicable Unit U2-series (4-Way Cassette) Built-in type • Signal receiving unit can be installed in the inside indoor unit. The Air Conditioning Gateway.
CS-ME7RKUA 7 000 BTU Indoor Wall Mount Heat Pump
Page 1
... Control Timer Night Setback Air Louver, Vertical Power Failure Automatic Restart Self-Diagnosis Quiet Operation Air Filter Microprocessor LCD Wireless Type, Temp. O.D. Program, 1 Hr. Off Built-In Automatic Built-In Built-In Built-In Washable, Anti-Mold Accessories Refrigerant Line Set Airduct Extension Condensate Drain Pump Hard Wired Remote Controller Non-Removeable Remote control Bracket Available N/A Standard Available Available Operating Range Cooling (Max) Cooling (Min) Heating (Max) Heating (Min) Indoor Air Intake Temp Refer to Outdoor Unit Specification Refer to Outdoor...
... Control Timer Night Setback Air Louver, Vertical Power Failure Automatic Restart Self-Diagnosis Quiet Operation Air Filter Microprocessor LCD Wireless Type, Temp. O.D. Program, 1 Hr. Off Built-In Automatic Built-In Built-In Built-In Washable, Anti-Mold Accessories Refrigerant Line Set Airduct Extension Condensate Drain Pump Hard Wired Remote Controller Non-Removeable Remote control Bracket Available N/A Standard Available Available Operating Range Cooling (Max) Cooling (Min) Heating (Max) Heating (Min) Indoor Air Intake Temp Refer to Outdoor Unit Specification Refer to Outdoor...
CS-ME7RKUA 7 000 BTU Indoor Wall Mount Heat Pump
Page 2
.../32 Right piping hole Remote control 1-7/8 7/8 5-1/4 AUTO HEAT COOL DRY FAN FAN S P E ED A IR SW IN G O FF/O N ECONAVI AUTO CO MFO RT MODE T E M P AIR SWING POWERFUL/ QUIET FAN SPEED TIM ER ON 1 2 SET 3 O FF CAN CEL AC RC SET CHECK CLOCK RESET Remote control holder 2-3/8 2 16-1/8 (1-5/8~2-13/32) Relative position between the indoor unit and the installation plate 29-29/64 Installation plate Indoor unit external dimensions line 17-9/32 Left piping hole 3-3/4 1-11/16 17 Right piping hole 5-1/16 9-17...
.../32 Right piping hole Remote control 1-7/8 7/8 5-1/4 AUTO HEAT COOL DRY FAN FAN S P E ED A IR SW IN G O FF/O N ECONAVI AUTO CO MFO RT MODE T E M P AIR SWING POWERFUL/ QUIET FAN SPEED TIM ER ON 1 2 SET 3 O FF CAN CEL AC RC SET CHECK CLOCK RESET Remote control holder 2-3/8 2 16-1/8 (1-5/8~2-13/32) Relative position between the indoor unit and the installation plate 29-29/64 Installation plate Indoor unit external dimensions line 17-9/32 Left piping hole 3-3/4 1-11/16 17 Right piping hole 5-1/16 9-17...