Print Specs
Page 1
...) FOR NETWORK PROJECTOR CONTROL This model is a general estimate. Quick Repair Program under warranty Because its products are subject to continuous improvement, SANYO reserves the right to modify product design and specifications without notice and without a screen. The replacement time is equipped with four variously colored (red, blue, green, and yellow) projection surfaces via 'Color Board Mode'. Auto Keystone Correction, Auto Input Search and Auto PC Adjustment make it can even accept component video signals. It...
...) FOR NETWORK PROJECTOR CONTROL This model is a general estimate. Quick Repair Program under warranty Because its products are subject to continuous improvement, SANYO reserves the right to modify product design and specifications without notice and without a screen. The replacement time is equipped with four variously colored (red, blue, green, and yellow) projection surfaces via 'Color Board Mode'. Auto Keystone Correction, Auto Input Search and Auto PC Adjustment make it can even accept component video signals. It...
RS232 Basic
Page 3
.... Status Read Command 19 7.1. Input Mode Read Command 21 7.6. ON START Setting Command 15 6.35. ON START Cancel Command 15 6.36. D.ZOOM + Command 15 6.40. Computer1 S-Video Command 16 6.42. POINTER UP Command 16 6.46. ENTER Command 17 6.48. FREEZE OFF Command 17 6.50. Computer 1 Component Command 18 6.53. PRESENTATION TIMER Command 18 6.55. AUTO PC ADJ. KEYSTONE Command 18 7. Setting Read Command 22 7.8. Temp Read Command 22 7.9. PLC-XW200/250/300 Basic Serial Command Specifications 6.32. BRIGHTNESS - Command 14 6.33. IMAGE (Toggle) Command...
.... Status Read Command 19 7.1. Input Mode Read Command 21 7.6. ON START Setting Command 15 6.35. ON START Cancel Command 15 6.36. D.ZOOM + Command 15 6.40. Computer1 S-Video Command 16 6.42. POINTER UP Command 16 6.46. ENTER Command 17 6.48. FREEZE OFF Command 17 6.50. Computer 1 Component Command 18 6.53. PRESENTATION TIMER Command 18 6.55. AUTO PC ADJ. KEYSTONE Command 18 7. Setting Read Command 22 7.8. Temp Read Command 22 7.9. PLC-XW200/250/300 Basic Serial Command Specifications 6.32. BRIGHTNESS - Command 14 6.33. IMAGE (Toggle) Command...
RS232 Basic
Page 21
... out of the operating temperature, it starts Countdown. "28" [CR] Status: Cooling Down in Setting Menu is ON and POWER ON is used to Standby after about 90 seconds. When Power On is done. Response for projector's reliability. This shows that the status turns to Temperature Anomaly When the inside the projector reaches abnormal status, the projector is on a model. The fan spin time depends on the screen. Fan also stops unlike...
... out of the operating temperature, it starts Countdown. "28" [CR] Status: Cooling Down in Setting Menu is ON and POWER ON is used to Standby after about 90 seconds. When Power On is done. Response for projector's reliability. This shows that the status turns to Temperature Anomaly When the inside the projector reaches abnormal status, the projector is on a model. The fan spin time depends on the screen. Fan also stops unlike...
RS232 Basic
Page 22
...] 5 minutes with 5 digits numbers. Example "00410"[CR] shows 410 hours Unacceptable "?" [CR] 21/22 "21" [CR] Status: Cooling Down in which the projector returns "21" [CR]. Status: Power Save This shows that it automatically starts Cooling Down operation, in process after turned off because of lamp failure, it moves to Power Save / Cooling Down. PLC-XW200/250/300 Basic Serial Command Specifications information of temperature anomaly is canceled...
...] 5 minutes with 5 digits numbers. Example "00410"[CR] shows 410 hours Unacceptable "?" [CR] 21/22 "21" [CR] Status: Cooling Down in which the projector returns "21" [CR]. Status: Power Save This shows that it automatically starts Cooling Down operation, in process after turned off because of lamp failure, it moves to Power Save / Cooling Down. PLC-XW200/250/300 Basic Serial Command Specifications information of temperature anomaly is canceled...
RS232 Basic
Page 23
... hardware %3 problems, the first character becomes "E" like "-05.5" [CR]. Modification Version V1.01 Date History Modification 2009.10.28 Added new model (XW300) 22/22 When the temperature goes down to -, the first character %1 becomes "-" instead of sensor 2 follows. For 1 lamp projector, get all the temperature at once. PLC-XW200/250/300 Basic Serial Command Specifications 7.7.Setting Read Command Command "CR4" [CR] Detail Get screen setting status such...
... hardware %3 problems, the first character becomes "E" like "-05.5" [CR]. Modification Version V1.01 Date History Modification 2009.10.28 Added new model (XW300) 22/22 When the temperature goes down to -, the first character %1 becomes "-" instead of sensor 2 follows. For 1 lamp projector, get all the temperature at once. PLC-XW200/250/300 Basic Serial Command Specifications 7.7.Setting Read Command Command "CR4" [CR] Detail Get screen setting status such...
RS232 Expand
Page 10
... Set White Balance Green value Set White Balance Blue value Set Color Temp. value Set /Cancel Progressive Scan Set/Cancel Noise reduction Set Image mode Reset/Store for Image Adjustment 5.2 PC Adjust Control Command Table Execute command CF_FSYNC_%1[CR] CF_TDOTS_%1[CR] CF_CLAMP_%1[CR] CF_H-POS_%1[CR] CF_V-POS_%1[CR] CF_DDOTS_%1[CR] CF_DLINE_%1[CR] CF_PCSTORE_%1[CR] CF_PCMODEFREE_%1[CR] Item Set Fine Sync value Set Total Dots value Set Clamp Value Set Horizontal Position value Set Vertical Position value Set Display Dots value Set Display...
... Set White Balance Green value Set White Balance Blue value Set Color Temp. value Set /Cancel Progressive Scan Set/Cancel Noise reduction Set Image mode Reset/Store for Image Adjustment 5.2 PC Adjust Control Command Table Execute command CF_FSYNC_%1[CR] CF_TDOTS_%1[CR] CF_CLAMP_%1[CR] CF_H-POS_%1[CR] CF_V-POS_%1[CR] CF_DDOTS_%1[CR] CF_DLINE_%1[CR] CF_PCSTORE_%1[CR] CF_PCMODEFREE_%1[CR] Item Set Fine Sync value Set Total Dots value Set Clamp Value Set Horizontal Position value Set Vertical Position value Set Display Dots value Set Display...
RS232 Expand
Page 11
... for the case of no signal Set Display function Set Logo function Set Ceiling function Set Rear function Set Terminal function Set Standby Mode Set Power management function Set Power management time Set Power ON Start function Select Remote Control Reception Code Disable RC/Projector keys Input PIN code to release PJ Locj Select Fan mode Select Fan control mode Set channel of Closed caption Set color of Closed caption Set time when Filter warning OSD is displayed Reset Filter used time Set the value to Factory Default 5.8 Other Command Table Execute command CF_KEYEMU_%1[CR] CF_MENU_%1[CR...
... for the case of no signal Set Display function Set Logo function Set Ceiling function Set Rear function Set Terminal function Set Standby Mode Set Power management function Set Power management time Set Power ON Start function Select Remote Control Reception Code Disable RC/Projector keys Input PIN code to release PJ Locj Select Fan mode Select Fan control mode Set channel of Closed caption Set color of Closed caption Set time when Filter warning OSD is displayed Reset Filter used time Set the value to Factory Default 5.8 Other Command Table Execute command CF_KEYEMU_%1[CR] CF_MENU_%1[CR...
RS232 Expand
Page 12
... Green value White Balance Blue value Get setting value of Color temperature Get setting status of Noise reduction Get setting status of Progressive scan Get Selected Image status Get setting value of Image Gamma 6.2 PC Adjust Status Read Command Table Status read command CR_SERSYS[CR] Item Get selected current signal. Get selected source of currently selected Input Get selected source of Computer 1 Get selected source of Computer 2 Get selected source of Video Get selected system status in Auto mode...
... Green value White Balance Blue value Get setting value of Color temperature Get setting status of Noise reduction Get setting status of Progressive scan Get Selected Image status Get setting value of Image Gamma 6.2 PC Adjust Status Read Command Table Status read command CR_SERSYS[CR] Item Get selected current signal. Get selected source of currently selected Input Get selected source of Computer 1 Get selected source of Computer 2 Get selected source of Video Get selected system status in Auto mode...
RS232 Expand
Page 13
... Power management Get setting status of ON Start Get selected Remote Control Code Get setting status of Security Get RC/KEY disability status Get if PJ Lock is actually in operation Get setting statsus of PJ Lock on Menu Get selected Fan mode Get selected Fan Control Mode Get setting status of channel of Closed caption Get setting status of color of Closed caption Get Filter used time Get the information for Filter replacement time Get time when Filter warning OSD is displayed 6.9 Other Status Read Command Status...
... Power management Get setting status of ON Start Get selected Remote Control Code Get setting status of Security Get RC/KEY disability status Get if PJ Lock is actually in operation Get setting statsus of PJ Lock on Menu Get selected Fan mode Get selected Fan Control Mode Get setting status of channel of Closed caption Get setting status of color of Closed caption Get Filter used time Get the information for Filter replacement time Get time when Filter warning OSD is displayed 6.9 Other Status Read Command Status...
RS232 Expand
Page 15
PLC-XW200/250/300 Expand Serial Command Functional Specifications 8. "000" [CR] : (0x06, 0x0D) When receiving Functional Execution Command "nnn" [CR] : Except "000" , when it returns the response. See Error Code Table for pop-up menu 2) When Eco mode is selected in Standby mode of Setting menu and projector is unable to receive the next command, it is in format as below : Pattern1 : "CF_COMMAND" [CR] Pattern2 : "CF_COMMAND_...
PLC-XW200/250/300 Expand Serial Command Functional Specifications 8. "000" [CR] : (0x06, 0x0D) When receiving Functional Execution Command "nnn" [CR] : Except "000" , when it returns the response. See Error Code Table for pop-up menu 2) When Eco mode is selected in Standby mode of Setting menu and projector is unable to receive the next command, it is in format as below : Pattern1 : "CF_COMMAND" [CR] Pattern2 : "CF_COMMAND_...
RS232 Expand
Page 17
... Suspend mode.) This command is available in normal Power ON status. PLC-XW200/250/300 Expand Serial Command Functional Specifications 8.4.5 CF_SHARP Command Command "CF_SHARP_%1"[CR] "000~015 Directly select Sharpness setting value %1 "UP Current Sharpness setting value + 1 "DN Current Sharpness setting value - 1 Details Set Sharpness value of user control Projector does not save the value set with this command so that it returns its original when projector turning into Stanby mode or...
... Suspend mode.) This command is available in normal Power ON status. PLC-XW200/250/300 Expand Serial Command Functional Specifications 8.4.5 CF_SHARP Command Command "CF_SHARP_%1"[CR] "000~015 Directly select Sharpness setting value %1 "UP Current Sharpness setting value + 1 "DN Current Sharpness setting value - 1 Details Set Sharpness value of user control Projector does not save the value set with this command so that it returns its original when projector turning into Stanby mode or...
RS232 Expand
Page 18
..." ------- Colorboard(Fixed value to focus on motion detection L2 is available in normal Power ON status. Image4 (the value set and stored by a user) "CUSTOM2" ----- Cancel Noise Reduction "L1" --------- Cinema (Fixed value to project image onto colored board) "CUSTOM1" ----- Image2 (the value set and stored by a user) "CUSTOM4" ----- PLC-XW200/250/300 Expand Serial Command Functional Specifications Acceptable "000"[CR] Response Unacceptable "Error Code"[CR] 8.4.9 CF_PROGV Command Command "CF_PROGV_%1"[CR...
..." ------- Colorboard(Fixed value to focus on motion detection L2 is available in normal Power ON status. Image4 (the value set and stored by a user) "CUSTOM2" ----- Cancel Noise Reduction "L1" --------- Cinema (Fixed value to project image onto colored board) "CUSTOM1" ----- Image2 (the value set and stored by a user) "CUSTOM4" ----- PLC-XW200/250/300 Expand Serial Command Functional Specifications Acceptable "000"[CR] Response Unacceptable "Error Code"[CR] 8.4.9 CF_PROGV Command Command "CF_PROGV_%1"[CR...
RS232 Expand
Page 20
...: it is current Display Dots Horizontal value + %1 Position value. "UP Current Clamp setting value + 1 "DN Current Clamp setting value - 1 Details Set Clamp value of PC signal Projector does not save the value set with this command so that it returns its original when projector turning into Stanby mode or ALL is OFF. PLC-XW200/250/300 Expand Serial Command Functional Specifications 8.5 PC Adjust Control Command 8.5.1 CF_FSYNC Command Command "CF_FSYNC_%1"[CR] "0000...
...: it is current Display Dots Horizontal value + %1 Position value. "UP Current Clamp setting value + 1 "DN Current Clamp setting value - 1 Details Set Clamp value of PC signal Projector does not save the value set with this command so that it returns its original when projector turning into Stanby mode or ALL is OFF. PLC-XW200/250/300 Expand Serial Command Functional Specifications 8.5 PC Adjust Control Command 8.5.1 CF_FSYNC Command Command "CF_FSYNC_%1"[CR] "0000...
RS232 Expand
Page 22
... and turns it to Mode1~Mode5. Set Mode1 to Free status %1 "MODE3" ---- Set Mode2 to Free status "MODE2" ---- Acceptable "000"[CR] Response Unacceptable "101"[CR] ---- Store current PC Adjust status to Free status "MODE4" ---- Set Mode3 to Mode4 "MODE5" ---- PLC-XW200/250/300 Expand Serial Command Functional Specifications 8.5.8 CF_PCSTORE Command Command "CF_PCSTORE_%1"[CR] "MODE1" ---- Acceptable "000"[CR] Response Unacceptable "101"[CR] ---- This command operates the same way as Total dots) to Free status.
... and turns it to Mode1~Mode5. Set Mode1 to Free status %1 "MODE3" ---- Set Mode2 to Free status "MODE2" ---- Acceptable "000"[CR] Response Unacceptable "101"[CR] ---- Store current PC Adjust status to Free status "MODE4" ---- Set Mode3 to Mode4 "MODE5" ---- PLC-XW200/250/300 Expand Serial Command Functional Specifications 8.5.8 CF_PCSTORE Command Command "CF_PCSTORE_%1"[CR] "MODE1" ---- Acceptable "000"[CR] Response Unacceptable "101"[CR] ---- This command operates the same way as Total dots) to Free status.
RS232 Expand
Page 26
... Set Keystone OFF Details Change Keystone distortion correction This command is available in negative order (Normal →Custom → Wide →Normal) Select image size on screen. PLC-XW200/250/300 Expand Serial Command Functional Specifications 8.7 Screen Control Command 8.7.1 CF_SCREEN Command Command "CF_SCREEN_%1"[CR] Input is Computer "NORMAL Select Normal size "TRUE Select True size "WIDE Select Wide size "FULL Select Full screen size "CUSTOM Select Custom size "DZOOM_UP Expand image size with Digital Zoom "DZOOM_DN Reduce image size with Digital Zoom...
... Set Keystone OFF Details Change Keystone distortion correction This command is available in negative order (Normal →Custom → Wide →Normal) Select image size on screen. PLC-XW200/250/300 Expand Serial Command Functional Specifications 8.7 Screen Control Command 8.7.1 CF_SCREEN Command Command "CF_SCREEN_%1"[CR] Input is Computer "NORMAL Select Normal size "TRUE Select True size "WIDE Select Wide size "FULL Select Full screen size "CUSTOM Select Custom size "DZOOM_UP Expand image size with Digital Zoom "DZOOM_DN Reduce image size with Digital Zoom...
RS232 Expand
Page 27
... in Custom mode, projector changes image mode into Custom by receiving this command. Acceptable "000"[CR] Response Unacceptable "Error Code"[CR] 8.7.6 CF_VPOS Command Command "CF_VPOS_%1"[CR] "015 15 "014 14 "002 2 "001 1 "000 0 %1 "-01 1 "-02 2 Details "-14 14 "-15 15 "UP Vertical Position setting value + 1 "DN Vertical Position setting value - 1 Set Vertical Position 26 / 64 Note1) When Screen setting is available in normal Power ON status. Note2...
... in Custom mode, projector changes image mode into Custom by receiving this command. Acceptable "000"[CR] Response Unacceptable "Error Code"[CR] 8.7.6 CF_VPOS Command Command "CF_VPOS_%1"[CR] "015 15 "014 14 "002 2 "001 1 "000 0 %1 "-01 1 "-02 2 Details "-14 14 "-15 15 "UP Vertical Position setting value + 1 "DN Vertical Position setting value - 1 Set Vertical Position 26 / 64 Note1) When Screen setting is available in normal Power ON status. Note2...
RS232 Expand
Page 32
... Input search are OFF, it returns error code "101".. OFF command while Keystone and Input search are OFF, it returns error code "101". If the command is returned, in the case of Auto setup This command is available in normal Power ON status. Switch backward (Blue Back→Black Back→User→Blue Back) Details Set Screen status for no signal.(Available only in the normal Power ON status) The status set by this , projector returns error code...
... Input search are OFF, it returns error code "101".. OFF command while Keystone and Input search are OFF, it returns error code "101". If the command is returned, in the case of Auto setup This command is available in normal Power ON status. Switch backward (Blue Back→Black Back→User→Blue Back) Details Set Screen status for no signal.(Available only in the normal Power ON status) The status set by this , projector returns error code...
RS232 Expand
Page 59
... projector is actually locked. PLC-XW200/250/300 Expand Serial Command Functional Specifications 9.11.15 CR_RCODE Command Command "CR_RCODE"[CR] Details Get selected Remote Control Code Acceptable "000_%a"[CR] Response %a "001 Code1 is selected "002 Code2 is selected Unacceptable "Error Code" [CR] 9.11.16 CR_SECURITY Command Command "CR_SECURITY" [CR] Details Get Security Mode setting status Acceptable "000_%1[CR] Response %1 "ON PJ Lock setting on Menu is ON-1 or ON-2 "OFF PJ Lock setting...
... projector is actually locked. PLC-XW200/250/300 Expand Serial Command Functional Specifications 9.11.15 CR_RCODE Command Command "CR_RCODE"[CR] Details Get selected Remote Control Code Acceptable "000_%a"[CR] Response %a "001 Code1 is selected "002 Code2 is selected Unacceptable "Error Code" [CR] 9.11.16 CR_SECURITY Command Command "CR_SECURITY" [CR] Details Get Security Mode setting status Acceptable "000_%1[CR] Response %1 "ON PJ Lock setting on Menu is ON-1 or ON-2 "OFF PJ Lock setting...
RS232 Expand
Page 65
... CF_LANG Command CR_LANG Command Added "Kazakh" Added new model (XW300) 64 / 64 Acceptable "000_%a_%b_%c"[CR] %a Sensor 1 temp. (External temp.) %b Sensor 2 temp. (Internal temp.1) %c Sensor 3 temp. (Internal temp.2) [Example] "_31.5F"[CR] "_" indicates a space. is safe S" Sensor detects no critical temp N" The example shows that sensor 1 indicates 31.5 degrees and the temperature is deleted. When the projector is reset, "□000S" is set, and every time abnormal temperature occurs...
... CF_LANG Command CR_LANG Command Added "Kazakh" Added new model (XW300) 64 / 64 Acceptable "000_%a_%b_%c"[CR] %a Sensor 1 temp. (External temp.) %b Sensor 2 temp. (Internal temp.1) %c Sensor 3 temp. (Internal temp.2) [Example] "_31.5F"[CR] "_" indicates a space. is safe S" Sensor detects no critical temp N" The example shows that sensor 1 indicates 31.5 degrees and the temperature is deleted. When the projector is reset, "□000S" is set, and every time abnormal temperature occurs...
IR Command List
Page 1
1/1 SANYO: PLC-XW300 IR Command List □ Transmission format of LCD projector operation key : NEC Format (single command / command pipelining mode) □ Custom Code + Custom Code : 2 patterns as below 33h+00h(Default;code1), 33h+11h(code2) Key Data Code No. (HEX) Function 1 17 AUTO SET 2 00 ON-OFF 3 38 COMPUTER 1 4 39 COMPUTER 2 5 3D VIDEO 6 3E S-VIDEO 7 83 COMPONENT 8 8C CURSOR UP 9 1E CURSOR LEFT 10 0F SELECT 11 1D CURSOR...
1/1 SANYO: PLC-XW300 IR Command List □ Transmission format of LCD projector operation key : NEC Format (single command / command pipelining mode) □ Custom Code + Custom Code : 2 patterns as below 33h+00h(Default;code1), 33h+11h(code2) Key Data Code No. (HEX) Function 1 17 AUTO SET 2 00 ON-OFF 3 38 COMPUTER 1 4 39 COMPUTER 2 5 3D VIDEO 6 3E S-VIDEO 7 83 COMPONENT 8 8C CURSOR UP 9 1E CURSOR LEFT 10 0F SELECT 11 1D CURSOR...