Print Specs
Page 1
... software) PIN code Label Lamp replacement label UL cable card Warranty card Three years parts and labor; 90 days original lamp; Back Panel ©2009 SANYO 3,000 LUMENS z XGA z ULTRAPORTABLE PROJECTOR PLC-XW300 ULTRAPORTABLE PROJECTOR 3LCD Built-in Network Closed Caption ULTRA-COMPACT, FULLY PORTABLE XGA DESIGN Not much larger than a laptop PC, the...
... software) PIN code Label Lamp replacement label UL cable card Warranty card Three years parts and labor; 90 days original lamp; Back Panel ©2009 SANYO 3,000 LUMENS z XGA z ULTRAPORTABLE PROJECTOR PLC-XW300 ULTRAPORTABLE PROJECTOR 3LCD Built-in Network Closed Caption ULTRA-COMPACT, FULLY PORTABLE XGA DESIGN Not much larger than a laptop PC, the...
RS232 Basic
Page 1
BASIC SERIAL COMMAND SPECIFICATIONS PLC-XW200 PLC-XW250 PLC-XW300 Ver.1.01 SANYO Electric Co., Ltd DS Company Projector Division
BASIC SERIAL COMMAND SPECIFICATIONS PLC-XW200 PLC-XW250 PLC-XW300 Ver.1.01 SANYO Electric Co., Ltd DS Company Projector Division
RS232 Basic
Page 4
... be used to a computer and a projector. These specifications define projector control commands for connection to remotely control a projector through RS-232C from a computer. 2. Serial Interface Specifications 2.1. PC COM 1 Projector Control Port D-Sub 9 Pin D-Sub 9 Pin 3/22 PLC-XW200/250/300 Basic Serial Command Specifications 1. The projector control commands are used for PLC-XW200/250/300. 1.2. Connection Dedicated...
... be used to a computer and a projector. These specifications define projector control commands for connection to remotely control a projector through RS-232C from a computer. 2. Serial Interface Specifications 2.1. PC COM 1 Projector Control Port D-Sub 9 Pin D-Sub 9 Pin 3/22 PLC-XW200/250/300 Basic Serial Command Specifications 1. The projector control commands are used for PLC-XW200/250/300. 1.2. Connection Dedicated...
RS232 Basic
Page 5
...5. The number of characters of response to receive carriage return (0x0D) after the projector receives the first data "C". 4. For Command pipelining, wait for the interval of buffer...ends with carriage return (0x0D). 2. Do not issue any command. 6. Z). 4/22 The projector control command is no Response for internal initialization after receiving a response. When a command is...Communication 1. Please see [7. It takes about 5 seconds for more than 100ms PC → Projector Projector → PC Command "C" "0" "7" CR ACK CR Next Command Response A few ms 5s ...
...5. The number of characters of response to receive carriage return (0x0D) after the projector receives the first data "C". 4. For Command pipelining, wait for the interval of buffer...ends with carriage return (0x0D). 2. Do not issue any command. 6. Z). 4/22 The projector control command is no Response for internal initialization after receiving a response. When a command is...Communication 1. Please see [7. It takes about 5 seconds for more than 100ms PC → Projector Projector → PC Command "C" "0" "7" CR ACK CR Next Command Response A few ms 5s ...
RS232 Basic
Page 9
...ms. 6.2.2. Command Pipelining When some functions need the command pipelining, the performance is the same as below. When the projector receives other incoming commands within 120 ms, the function is executed for another 120 ms from the moment. 6.2.3. When receiving...received Functional Execution Commands. 6.1.2 " " CR When the received data cannot be decoded. 6.2. PC → Projector Projector → PC Command "C" "0" "7" CR ACK CR Processing A few ms 5s 8/22 PLC-XW200/250/300 Basic Serial Command Specifications 6. Format 6.1.1 PC issues a command in format as that of ...
...ms. 6.2.2. Command Pipelining When some functions need the command pipelining, the performance is the same as below. When the projector receives other incoming commands within 120 ms, the function is executed for another 120 ms from the moment. 6.2.3. When receiving...received Functional Execution Commands. 6.1.2 " " CR When the received data cannot be decoded. 6.2. PC → Projector Projector → PC Command "C" "0" "7" CR ACK CR Processing A few ms 5s 8/22 PLC-XW200/250/300 Basic Serial Command Specifications 6. Format 6.1.1 PC issues a command in format as that of ...
RS232 Basic
Page 10
...mode of below, Functional Execution Commands are invalid. 9/22 Note) When the status is as above, even if the projector receives other commands, it returns [ACK] [CR]. 2) When Eco mode is selected in Standby, Functional Execution Commands are limited.... PLC-XW200/250/300 Basic Serial Command Specifications 6.4. Operation Requirements 1) When the projector's status is any of Setting menu and projector is terminated NONE (No Execution) NONE (No Execution) NONE (No Execution) NONE (No ...
...mode of below, Functional Execution Commands are invalid. 9/22 Note) When the status is as above, even if the projector receives other commands, it returns [ACK] [CR]. 2) When Eco mode is selected in Standby, Functional Execution Commands are limited.... PLC-XW200/250/300 Basic Serial Command Specifications 6.4. Operation Requirements 1) When the projector's status is any of Setting menu and projector is terminated NONE (No Execution) NONE (No Execution) NONE (No Execution) NONE (No ...
RS232 Basic
Page 11
... OFF Command Command "C02" [CR] Detail Power OFF (Standby). When sending this command while Input search is set to On1 or On2, Note 2) Although projector returns "OK", this command is not executed while Monitor out is executed. When sending this command is sent, Quick Power OFF is selected in Terminal... menu, Acceptable [ACK] [CR] Response Unacceptable " "[CR] 10/22 is terminated. PLC-XW200/250/300 Basic Serial Command Specifications 6.5. However, as soon as ON/STAND-BY button of the...
... OFF Command Command "C02" [CR] Detail Power OFF (Standby). When sending this command while Input search is set to On1 or On2, Note 2) Although projector returns "OK", this command is not executed while Monitor out is executed. When sending this command is sent, Quick Power OFF is selected in Terminal... menu, Acceptable [ACK] [CR] Response Unacceptable " "[CR] 10/22 is terminated. PLC-XW200/250/300 Basic Serial Command Specifications 6.5. However, as soon as ON/STAND-BY button of the...
RS232 Basic
Page 12
... of the remote control for Mute OFF, but does not work for Mute OFF. PLC-XW200/250/300 Basic Serial Command Specifications 6.10. This command operates the same way as "VOLUME-" button of the projector and remote control. VOLUME + Command Command "C09" [CR] Detail Volume Up. ..." "[CR] 6.14. Command Command "C0A" [CR] Detail Volume Down This command operates the same way as "VOLUME+" button of the projector and remote control. AUDIO MUTE OFF Command Command "C0C" [CR] Detail Sound Mute OFF. Video Command Command "C07" [CR] Detail Select Video Input ...
... of the remote control for Mute OFF, but does not work for Mute OFF. PLC-XW200/250/300 Basic Serial Command Specifications 6.10. This command operates the same way as "VOLUME-" button of the projector and remote control. VOLUME + Command Command "C09" [CR] Detail Volume Up. ..." "[CR] 6.14. Command Command "C0A" [CR] Detail Volume Down This command operates the same way as "VOLUME+" button of the projector and remote control. AUDIO MUTE OFF Command Command "C0C" [CR] Detail Sound Mute OFF. Video Command Command "C07" [CR] Detail Select Video Input ...
RS232 Basic
Page 17
... On-Screen Display Menu to On1 or On2, Acceptable [ACK] [CR] Response Unacceptable " "[CR] 6.42. PLC-XW200/250/300 Basic Serial Command Specifications 6.40. Although projector returns "OK", Input search is not executed with this command while Input search is set to the right. POINTER ...LEFT Command Command "C3B" [CR] Detail Move the Pointer of the remote control. This command works differently from the pointer ">" of the projector and remote control, and has no function of Computer1 input. Image Colorboard Command Command "C39" [CR] Detail Set image to the left. ...
... On-Screen Display Menu to On1 or On2, Acceptable [ACK] [CR] Response Unacceptable " "[CR] 6.42. PLC-XW200/250/300 Basic Serial Command Specifications 6.40. Although projector returns "OK", Input search is not executed with this command while Input search is set to the right. POINTER ...LEFT Command Command "C3B" [CR] Detail Move the Pointer of the remote control. This command works differently from the pointer ">" of the projector and remote control, and has no function of Computer1 input. Image Colorboard Command Command "C39" [CR] Detail Set image to the left. ...
RS232 Basic
Page 18
...[CR] Detail Move down the Pointer of the projector and remote control. This command works the same way as the pointer "▼" of the projector. Computer 1 Scart Command Command "C51" [CR...-screen image. FREEZE OFF Command Command "C44" [CR] Detail Cancel Freeze mode. Although projector returns "OK", Input search is not executed with this command while Input search is set to... 1 Analog RGB Command Command "C50" [CR] Detail Select Analog RGB input in Computer 1 Although projector returns "OK", Input search is not executed with this command while Input search is set to On1 or...
...[CR] Detail Move down the Pointer of the projector and remote control. This command works the same way as the pointer "▼" of the projector. Computer 1 Scart Command Command "C51" [CR...-screen image. FREEZE OFF Command Command "C44" [CR] Detail Cancel Freeze mode. Although projector returns "OK", Input search is not executed with this command while Input search is set to... 1 Analog RGB Command Command "C50" [CR] Detail Select Analog RGB input in Computer 1 Although projector returns "OK", Input search is not executed with this command while Input search is set to On1 or...
RS232 Basic
Page 19
Projector suspends Auto PC Adj. This command works the same way as "AUTO PC ADJ." PLC-XW200/250/300 Basic Serial Command Specifications 6.52. AUTO PC ADJ. PRESENTATION TIMER Command Command "C8A" [CR] Detail Execute Presentation Timer. .... function. operation when receiving this command while Input search is set to On1 or On2, Acceptable [ACK] [CR] Response Unacceptable " "[CR] 6.53. Although projector returns "OK", Input search is not executed with this command another time. Acceptable [ACK] [CR] Response Unacceptable " "[CR] 6.56. KEYSTONE ↓Command Command...
Projector suspends Auto PC Adj. This command works the same way as "AUTO PC ADJ." PLC-XW200/250/300 Basic Serial Command Specifications 6.52. AUTO PC ADJ. PRESENTATION TIMER Command Command "C8A" [CR] Detail Execute Presentation Timer. .... function. operation when receiving this command while Input search is set to On1 or On2, Acceptable [ACK] [CR] Response Unacceptable " "[CR] 6.53. Although projector returns "OK", Input search is not executed with this command another time. Acceptable [ACK] [CR] Response Unacceptable " "[CR] 6.56. KEYSTONE ↓Command Command...
RS232 Basic
Page 20
...due to lamp failure Unacceptable "?" [CR] 19/22 Format 7.1.1. When the received data cannot be decoded, the projector returns "?" [CR]. 7.2.Transfer Example Get input mode for projector with basic commands PC → Projector Projector → PC Command issues a command of getting current input mode "C" "R" "1" "CR" "1" "CR" ... Power Save/Cooling Down in process "04" = Power Save "21" = Cooling Down is in format as the required data. PLC-XW200/250/300 Basic Serial Command Specifications 7. "CR" Command [CR] Command 1 character See Basic Status Read Command Table 7.1.2.
...due to lamp failure Unacceptable "?" [CR] 19/22 Format 7.1.1. When the received data cannot be decoded, the projector returns "?" [CR]. 7.2.Transfer Example Get input mode for projector with basic commands PC → Projector Projector → PC Command issues a command of getting current input mode "C" "R" "1" "CR" "1" "CR" ... Power Save/Cooling Down in process "04" = Power Save "21" = Cooling Down is in format as the required data. PLC-XW200/250/300 Basic Serial Command Specifications 7. "CR" Command [CR] Command 1 character See Basic Status Read Command Table 7.1.2.
RS232 Basic
Page 21
... Cooling Down in process due to Temperature Anomaly When the inside the projector reaches abnormal status, the projector is automatically turned off and the fan spin finishes after Cooling Down due to power failure. The projector returns "10"[CR], which shows it moves to Standby after lamp ... Standby after about 90 seconds. Even if the temperature decreases during this time, Functional Execution Commands are not acceptable except POWER ON Command. PLC-XW200/250/300 Basic Serial Command Specifications [Details of Response] "00" [CR] Status : Power ON Normal image is on a model...
... Cooling Down in process due to Temperature Anomaly When the inside the projector reaches abnormal status, the projector is automatically turned off and the fan spin finishes after Cooling Down due to power failure. The projector returns "10"[CR], which shows it moves to Standby after lamp ... Standby after about 90 seconds. Even if the temperature decreases during this time, Functional Execution Commands are not acceptable except POWER ON Command. PLC-XW200/250/300 Basic Serial Command Specifications [Details of Response] "00" [CR] Status : Power ON Normal image is on a model...
RS232 Basic
Page 22
... "21" [CR]. "21" [CR] Status: Cooling Down in process after turned off due to lamp failure When a projector is turned off because of lamp failure, it moves to lamp failure This value is kept until the next operation starts. 7.5.Input Mode Read ...Command Command "CR1" [CR] Detail Get the selected Input No. Example "00410"[CR] shows 410 hours Unacceptable "?" [CR] 21/22 PLC-XW200/250/300 Basic Serial Command Specifications information of Cooling Down. Status No signal Response "00" Power Save / Cooling Down "24" Power Save "04" "04...
... "21" [CR]. "21" [CR] Status: Cooling Down in process after turned off due to lamp failure When a projector is turned off because of lamp failure, it moves to lamp failure This value is kept until the next operation starts. 7.5.Input Mode Read ...Command Command "CR1" [CR] Detail Get the selected Input No. Example "00410"[CR] shows 410 hours Unacceptable "?" [CR] 21/22 PLC-XW200/250/300 Basic Serial Command Specifications information of Cooling Down. Status No signal Response "00" Power Save / Cooling Down "24" Power Save "04" "04...
RS232 Basic
Page 23
...%2 Temperature of sensor 2 %3 Temperature of sensor 3 Temperature data is lighting or not. For 1 lamp projector, get all the temperature at once. Response %2 When no temperature data can be returned due to -, ... 2 follows. Modification Version V1.01 Date History Modification 2009.10.28 Added new model (XW300) 22/22 Unacceptable " "[CR] 7.9.Lamp Mode Read Command Command "CR7" [CR] ...] "11"[CR] = Normal Screen Setting "10"[CR] = Picture is out. PLC-XW200/250/300 Basic Serial Command Specifications 7.7.Setting Read Command Command "CR4" [CR] Detail Get screen setting ...
...%2 Temperature of sensor 2 %3 Temperature of sensor 3 Temperature data is lighting or not. For 1 lamp projector, get all the temperature at once. Response %2 When no temperature data can be returned due to -, ... 2 follows. Modification Version V1.01 Date History Modification 2009.10.28 Added new model (XW300) 22/22 Unacceptable " "[CR] 7.9.Lamp Mode Read Command Command "CR7" [CR] ...] "11"[CR] = Normal Screen Setting "10"[CR] = Picture is out. PLC-XW200/250/300 Basic Serial Command Specifications 7.7.Setting Read Command Command "CR4" [CR] Detail Get screen setting ...
RS232 Expand
Page 1
EXPAND SERIAL COMMAND FUNCTIONAL SPECIFICATIONS PLC-XW200 PLC-XW250 PLC-XW300 Ver. 1.02 SANYO Electric Co., Ltd DS Company Projector Division
EXPAND SERIAL COMMAND FUNCTIONAL SPECIFICATIONS PLC-XW200 PLC-XW250 PLC-XW300 Ver. 1.02 SANYO Electric Co., Ltd DS Company Projector Division
RS232 Expand
Page 8
...) Transmission Speed: initial setting value is 19200 Note2) Transmission Speed can be used to a computer and a projector. Overview 1.1 This Functional Specification defines communication functions for PLC-XW200/250/300. 1.2 Compatible to Firmware Ver. 1.x of the projector. 1.3 Most commands can be changed in service mode. 2.2 Connection Dedicated serial cable must be used for a connection...
...) Transmission Speed: initial setting value is 19200 Note2) Transmission Speed can be used to a computer and a projector. Overview 1.1 This Functional Specification defines communication functions for PLC-XW200/250/300. 1.2 Compatible to Firmware Ver. 1.x of the projector. 1.3 Most commands can be changed in service mode. 2.2 Connection Dedicated serial cable must be used for a connection...
RS232 Expand
Page 9
...: Functional Execution Command and Status Read Command. - Name Definition 1. Data from a controller to a projector is defined as COMMAND, and data from a projector Acceptable: "000". Response also ends with cartridge return code. Error Code Table]. 6. %a : Parameter in AC power. PLC-XW200/250/300 Expand Serial Command Functional Specifications 3. During this time commands cannot be...
...: Functional Execution Command and Status Read Command. - Name Definition 1. Data from a controller to a projector is defined as COMMAND, and data from a projector Acceptable: "000". Response also ends with cartridge return code. Error Code Table]. 6. %a : Parameter in AC power. PLC-XW200/250/300 Expand Serial Command Functional Specifications 3. During this time commands cannot be...
RS232 Expand
Page 11
PLC-XW200/250/300 Expand Serial Command Functional Specifications 5.5 Lamp Command Table Execute command CF_LAMPH_%1[CR] CF_LAMPMODE_%1[CR] CF_LAMPLIFECONTRL_%1[CR] Item Reset total running ...Other Command Table Execute command CF_KEYEMU_%1[CR] CF_MENU_%1[CR] CF_POWER_%1[CR] CF_FREEZE _%1[CR] CF_VMUTE _%1[CR] CF_PTIMER _%1[CR] Item Behave the same as corresponding key of projector top panel Switch ON/OFF of Sound Mute 5.7 Setting Command Table Execute command CF_LANG_%1[CR] CF_MENUPOSITION_%1[CR] CF_INPUTSEARCH_%1[CR] CF_AUTOSETUPPCADJ_%1[CR] CF_AUTOSETUPKEYSTONE_%1[CR] CF_AUTOSETUP_%1[CR...
PLC-XW200/250/300 Expand Serial Command Functional Specifications 5.5 Lamp Command Table Execute command CF_LAMPH_%1[CR] CF_LAMPMODE_%1[CR] CF_LAMPLIFECONTRL_%1[CR] Item Reset total running ...Other Command Table Execute command CF_KEYEMU_%1[CR] CF_MENU_%1[CR] CF_POWER_%1[CR] CF_FREEZE _%1[CR] CF_VMUTE _%1[CR] CF_PTIMER _%1[CR] Item Behave the same as corresponding key of projector top panel Switch ON/OFF of Sound Mute 5.7 Setting Command Table Execute command CF_LANG_%1[CR] CF_MENUPOSITION_%1[CR] CF_INPUTSEARCH_%1[CR] CF_AUTOSETUPPCADJ_%1[CR] CF_AUTOSETUPKEYSTONE_%1[CR] CF_AUTOSETUP_%1[CR...
RS232 Expand
Page 13
PLC-XW200/250/300 Expand Serial Command Functional Specifications 6.6 Lamp Status Read Command Table Status read...time Get lamp total running time Get corresponding lamp use time Get Lamp Mode status Get lamp lighting status Get projector total running time Get lamp number Get lamp life mode 6.7 Sound Status Read Command Table Status read command CR_VOLUME...CR] CR_VMUTE[CR] CR_FREEZE[CR] CR_PTIMER[CR] CR_TEMPWARN[CR] CR_TEMP[CR] CR_TEMPFAIL[CR] Item Get setting status of Projector behavior Get Signal Status if there is a signal or not Get setting status of No Show Get setting status of Freeze...
PLC-XW200/250/300 Expand Serial Command Functional Specifications 6.6 Lamp Status Read Command Table Status read...time Get lamp total running time Get corresponding lamp use time Get Lamp Mode status Get lamp lighting status Get projector total running time Get lamp number Get lamp life mode 6.7 Sound Status Read Command Table Status read command CR_VOLUME...CR] CR_VMUTE[CR] CR_FREEZE[CR] CR_PTIMER[CR] CR_TEMPWARN[CR] CR_TEMP[CR] CR_TEMPFAIL[CR] Item Get setting status of Projector behavior Get Signal Status if there is a signal or not Get setting status of No Show Get setting status of Freeze...