RS232 Basic
Page 1
BASIC SERIAL COMMAND SPECIFICATIONS PLC-XW200 PLC-XW250 PLC-XW300 Ver.1.01 SANYO Electric Co., Ltd DS Company Projector Division
BASIC SERIAL COMMAND SPECIFICATIONS PLC-XW200 PLC-XW250 PLC-XW300 Ver.1.01 SANYO Electric Co., Ltd DS Company Projector Division
RS232 Basic
Page 2
... Blackboard (Green) Command 13 6.27. Transfer Specifications 3 2.2. Operation Requirements 9 6.5. POWER OFF Command 10 6.8. VOLUME - VIDEO MUTE ON Command 12 6.16. MENU OFF Command 14 6.30. PLC-XW200/250/300 Basic Serial Command Specifications CONTENTS 1. Overview ...3 2. Serial Interface Specifications 3 2.1. Connection ...3 3. Status Read Command Table 7 6. Functional Execution Command 8 6.1. Format ...8 6.2. Transfer Example ...8 6.4. POWER ON Command...
... Blackboard (Green) Command 13 6.27. Transfer Specifications 3 2.2. Operation Requirements 9 6.5. POWER OFF Command 10 6.8. VOLUME - VIDEO MUTE ON Command 12 6.16. MENU OFF Command 14 6.30. PLC-XW200/250/300 Basic Serial Command Specifications CONTENTS 1. Overview ...3 2. Serial Interface Specifications 3 2.1. Connection ...3 3. Status Read Command Table 7 6. Functional Execution Command 8 6.1. Format ...8 6.2. Transfer Example ...8 6.4. POWER ON Command...
RS232 Basic
Page 3
PLC-XW200/250/300 Basic Serial Command Specifications 6.32. ON START Setting Command 15 6.35. D.ZOOM + Command 15 6.40. POINTER DOWN Command 17 6.47. Format ...19 7.2. Status ...
PLC-XW200/250/300 Basic Serial Command Specifications 6.32. ON START Setting Command 15 6.35. D.ZOOM + Command 15 6.40. POINTER DOWN Command 17 6.47. Format ...19 7.2. Status ...
RS232 Basic
Page 4
PLC-XW200/250/300 Basic Serial Command Specifications 1. Serial Interface Specifications 2.1. Connection Dedicated serial cable must be changed in service mode. 2.2. Transfer Specifications Item Specifications Synchronous system ... Overview 1.1. These specifications define projector control commands for connection to remotely control a projector through RS-232C from a computer. 2. The projector control commands are used for PLC-XW200/250/300. 1.2.
PLC-XW200/250/300 Basic Serial Command Specifications 1. Serial Interface Specifications 2.1. Connection Dedicated serial cable must be changed in service mode. 2.2. Transfer Specifications Item Specifications Synchronous system ... Overview 1.1. These specifications define projector control commands for connection to remotely control a projector through RS-232C from a computer. 2. The projector control commands are used for PLC-XW200/250/300. 1.2.
RS232 Basic
Page 5
... and Status Read Commands. More than one second to Status Read Commands depends on commands. Please see [7. During this time, it does not operate. Z). 4/22 PLC-XW200/250/300 Basic Serial Command Specifications 3. Notes for commands must be Capital (A - There are two types of Status Read Command: "CR0" [CR] 3. When it takes...
... and Status Read Commands. More than one second to Status Read Commands depends on commands. Please see [7. During this time, it does not operate. Z). 4/22 PLC-XW200/250/300 Basic Serial Command Specifications 3. Notes for commands must be Capital (A - There are two types of Status Read Command: "CR0" [CR] 3. When it takes...
RS232 Basic
Page 6
... C2A C2B C2C C2D C2E C2F C30 C31 C32 C33 C34 C35 C36 C37 C38 C39 C3A C3B C3C C3D C3E C3F Item BRIGHTNESS + BRIGHTNESS - PLC-XW200/250/300 Basic Serial Command Specifications 4.
... C2A C2B C2C C2D C2E C2F C30 C31 C32 C33 C34 C35 C36 C37 C38 C39 C3A C3B C3C C3D C3E C3F Item BRIGHTNESS + BRIGHTNESS - PLC-XW200/250/300 Basic Serial Command Specifications 4.
RS232 Basic
Page 7
Command C80 C81 C82 C83 C84 C85 C86 C87 C88 C89 C8A C8B C8C C8D C8E C8F C90 C91 C92 C93 C94 C95 C96 C97 C98 C99 C9A C9B C9C Item Auto PC ADJ. PLC-XW200/250/300 Basic Serial Command Specifications Command C40 C41 C42 C43 C44 C45 C46 C47 C48 C49 C4A C4B C4C C4D C4E C4F C50 C51 C52 C53 C54 C55 C56 C57 C58 C59 C5A C5B C5C Item FREEZE ON FREEZE OFF Computer 1 Analog RGB Computer 1 Scart Computer 1 Component ――― means no function. PRESENTATION TIMER KEYSTONE ↑ KEYSTONE 6/22
Command C80 C81 C82 C83 C84 C85 C86 C87 C88 C89 C8A C8B C8C C8D C8E C8F C90 C91 C92 C93 C94 C95 C96 C97 C98 C99 C9A C9B C9C Item Auto PC ADJ. PLC-XW200/250/300 Basic Serial Command Specifications Command C40 C41 C42 C43 C44 C45 C46 C47 C48 C49 C4A C4B C4C C4D C4E C4F C50 C51 C52 C53 C54 C55 C56 C57 C58 C59 C5A C5B C5C Item FREEZE ON FREEZE OFF Computer 1 Analog RGB Computer 1 Scart Computer 1 Component ――― means no function. PRESENTATION TIMER KEYSTONE ↑ KEYSTONE 6/22
RS232 Basic
Page 8
Memo 7/22 PLC-XW200/250/300 Basic Serial Command Specifications 5. Status Read Command Table Command CR0 CR1 CR2 Item Status Read Input Mode Read ――― CR3 (Corresponding) Lamp Time Read CR4 CR5 Setting Read ――― CR6 Temp Read CR7 Lamp Mode Read ――― means no function.
Memo 7/22 PLC-XW200/250/300 Basic Serial Command Specifications 5. Status Read Command Table Command CR0 CR1 CR2 Item Status Read Input Mode Read ――― CR3 (Corresponding) Lamp Time Read CR4 CR5 Setting Read ――― CR6 Temp Read CR7 Lamp Mode Read ――― means no function.
RS232 Basic
Page 9
... the command pipelining, the performance is the same as below. PC → Projector Projector → PC Command "C" "0" "7" CR ACK CR Processing A few ms 5s 8/22 PLC-XW200/250/300 Basic Serial Command Specifications 6. When receiving the appropriate command, the function is stopped. 6.3. Transfer Example Switch the projector to decode and returns a result...
... the command pipelining, the performance is the same as below. PC → Projector Projector → PC Command "C" "0" "7" CR ACK CR Processing A few ms 5s 8/22 PLC-XW200/250/300 Basic Serial Command Specifications 6. When receiving the appropriate command, the function is stopped. 6.3. Transfer Example Switch the projector to decode and returns a result...
RS232 Basic
Page 10
... in process Cooling Down due to Abnormal Temperature Abnormal Temperature Status Abnormal Power Status Power Save / Cooling Down in Standby, Functional Execution Commands are limited. PLC-XW200/250/300 Basic Serial Command Specifications 6.4.
... in process Cooling Down due to Abnormal Temperature Abnormal Temperature Status Abnormal Power Status Power Save / Cooling Down in Standby, Functional Execution Commands are limited. PLC-XW200/250/300 Basic Serial Command Specifications 6.4.
RS232 Basic
Page 11
PLC-XW200/250/300 Basic Serial Command Specifications 6.5. POWER ON Command Command "C00" [CR] Detail Power ON When already Power is ON, nothing is displayed. Acceptable [ACK] [...
PLC-XW200/250/300 Basic Serial Command Specifications 6.5. POWER ON Command Command "C00" [CR] Detail Power ON When already Power is ON, nothing is displayed. Acceptable [ACK] [...
RS232 Basic
Page 12
... does not work for Mute OFF. AUDIO MUTE OFF Command Command "C0C" [CR] Detail Sound Mute OFF. VOLUME + Command Command "C09" [CR] Detail Volume Up. PLC-XW200/250/300 Basic Serial Command Specifications 6.10. Acceptable [ACK] [CR] Response Unacceptable " "[CR] 6.14. This command works the same way as "MUTE" button of the...
... does not work for Mute OFF. AUDIO MUTE OFF Command Command "C0C" [CR] Detail Sound Mute OFF. VOLUME + Command Command "C09" [CR] Detail Volume Up. PLC-XW200/250/300 Basic Serial Command Specifications 6.10. Acceptable [ACK] [CR] Response Unacceptable " "[CR] 6.14. This command works the same way as "MUTE" button of the...
RS232 Basic
Page 13
... operation. Image Standard Command Command "C11" [CR] Detail Set image to Real mode. Image Real Command Command "C12" [CR] Detail Set image to Standard mode. PLC-XW200/250/300 Basic Serial Command Specifications 6.15. VIDEO MUTE OFF Command Command "C0E" [CR] Detail Video Mute OFF. Screen Wide size Command Command "C10" [CR...
... operation. Image Standard Command Command "C11" [CR] Detail Set image to Real mode. Image Real Command Command "C12" [CR] Detail Set image to Standard mode. PLC-XW200/250/300 Basic Serial Command Specifications 6.15. VIDEO MUTE OFF Command Command "C0E" [CR] Detail Video Mute OFF. Screen Wide size Command Command "C10" [CR...
RS232 Basic
Page 15
... Display Menu. IMAGE (Toggle) Command Command "C27"[CR] Detail Switch Image Setting status. MENU ON Command Command "C1C" [CR] Detail Display On-Screen Display Menu. PLC-XW200/250/300 Basic Serial Command Specifications 6.28. DISPLAY CLEAR Command Command "C1E" [CR] Detail Hide On-Screen Display.
... Display Menu. IMAGE (Toggle) Command Command "C27"[CR] Detail Switch Image Setting status. MENU ON Command Command "C1C" [CR] Detail Display On-Screen Display Menu. PLC-XW200/250/300 Basic Serial Command Specifications 6.28. DISPLAY CLEAR Command Command "C1E" [CR] Detail Hide On-Screen Display.
RS232 Basic
Page 16
PLC-XW200/250/300 Basic Serial Command Specifications 6.34. Power Management Ready Command Command "C2A" [CR] Detail Set Power Management to OFF mode. This status is stored ...
PLC-XW200/250/300 Basic Serial Command Specifications 6.34. Power Management Ready Command Command "C2A" [CR] Detail Set Power Management to OFF mode. This status is stored ...
RS232 Basic
Page 17
... the projector and remote control, and has no function of On-Screen Display Menu to On1 or On2, Acceptable [ACK] [CR] Response Unacceptable " "[CR] 6.42. PLC-XW200/250/300 Basic Serial Command Specifications 6.40. Acceptable [ACK] [CR] Response Unacceptable " "[CR] 6.44. Acceptable [ACK] [CR] Response Unacceptable " "[CR] 6.43. D.ZOOM - Command Command "C31...
... the projector and remote control, and has no function of On-Screen Display Menu to On1 or On2, Acceptable [ACK] [CR] Response Unacceptable " "[CR] 6.42. PLC-XW200/250/300 Basic Serial Command Specifications 6.40. Acceptable [ACK] [CR] Response Unacceptable " "[CR] 6.44. Acceptable [ACK] [CR] Response Unacceptable " "[CR] 6.43. D.ZOOM - Command Command "C31...
RS232 Basic
Page 18
... control for Freeze ON, but does not work for Freeze ON. Acceptable [ACK] [CR] Response Unacceptable " "[CR] 6.47. Acceptable [ACK] [CR] Response Unacceptable " "[CR] 6.49. PLC-XW200/250/300 Basic Serial Command Specifications 6.46. This command works the same way as "FREEZE" button of the projector and remote control. Computer 1 Analog RGB...
... control for Freeze ON, but does not work for Freeze ON. Acceptable [ACK] [CR] Response Unacceptable " "[CR] 6.47. Acceptable [ACK] [CR] Response Unacceptable " "[CR] 6.49. PLC-XW200/250/300 Basic Serial Command Specifications 6.46. This command works the same way as "FREEZE" button of the projector and remote control. Computer 1 Analog RGB...
RS232 Basic
Page 19
... "C8E" [CR] Detail Correct keystone distortion by reducing down part of image. Projector suspends Auto PC Adj. Acceptable [ACK] [CR] Response Unacceptable " "[CR] 18/22 PLC-XW200/250/300 Basic Serial Command Specifications 6.52. operation when receiving this command while Input search is set to On1 or On2, Acceptable [ACK] [CR] Response...
... "C8E" [CR] Detail Correct keystone distortion by reducing down part of image. Projector suspends Auto PC Adj. Acceptable [ACK] [CR] Response Unacceptable " "[CR] 18/22 PLC-XW200/250/300 Basic Serial Command Specifications 6.52. operation when receiving this command while Input search is set to On1 or On2, Acceptable [ACK] [CR] Response...
RS232 Basic
Page 20
When a projector receives the appropriate command, it returns a character line as below; PLC-XW200/250/300 Basic Serial Command Specifications 7. When the received data cannot be decoded, the projector returns "?" [CR]. 7.2.Transfer Example Get input mode for projector with ...
When a projector receives the appropriate command, it returns a character line as below; PLC-XW200/250/300 Basic Serial Command Specifications 7. When the received data cannot be decoded, the projector returns "?" [CR]. 7.2.Transfer Example Get input mode for projector with ...
RS232 Basic
Page 21
... POWER ON is executed, it moves to Standby because of the operating temperature, it automatically starts Cooling Down. Fan also stops unlike Cooling Down status. PLC-XW200/250/300 Basic Serial Command Specifications [Details of Response] "00" [CR] Status : Power ON Normal image is on a model. "80" [CR] Status: Standby When the...
... POWER ON is executed, it moves to Standby because of the operating temperature, it automatically starts Cooling Down. Fan also stops unlike Cooling Down status. PLC-XW200/250/300 Basic Serial Command Specifications [Details of Response] "00" [CR] Status : Power ON Normal image is on a model. "80" [CR] Status: Standby When the...