Page 5
Medalist 4342, 3232, 2122, 1722 and 1012 Product Manual iii Contents Introduction 1 Specification summary table 2 1.0 Drive specifications 5 1.1 Formatted capacity 5 1.1.1 Default logical geometry 5 1.1.2 Supported CHS translation geometries 6 1.2 Physical organization 6 1.3 Recording and interface technology 6 1.4 Physical characteristics 7...Temperature gradient 12 1.8.3 Humidity 12 1.8.4 Altitude 13 1.8.5 Shock 13 1.8.6 Vibration 13 1.9 Drive acoustics 14 1.10 Electromagnetic susceptibility 14 1.11 Reliability 14 1.12 Agency certification 15 1.12.1 Safety certification 15
Medalist 4342, 3232, 2122, 1722 and 1012 Product Manual iii Contents Introduction 1 Specification summary table 2 1.0 Drive specifications 5 1.1 Formatted capacity 5 1.1.1 Default logical geometry 5 1.1.2 Supported CHS translation geometries 6 1.2 Physical organization 6 1.3 Recording and interface technology 6 1.4 Physical characteristics 7...Temperature gradient 12 1.8.3 Humidity 12 1.8.4 Altitude 13 1.8.5 Shock 13 1.8.6 Vibration 13 1.9 Drive acoustics 14 1.10 Electromagnetic susceptibility 14 1.11 Reliability 14 1.12 Agency certification 15 1.12.1 Safety certification 15
Product Manual
Page 6
commands 30 iv Medalist 4342, 3232, 2122, 1722 and 1012 Product Manual 1.12.2 Electromagnetic Compatibility 15 1.12.3 FCC verification 15 2.0 Drive mounting and configuration 17 2.1 Handling and static-discharge precautions 17 2.2 Jumper settings 17 2.2.1 Master/slave configuration 17 2.2.2 Alternate capacity jumper 17 2.3 Drive mounting 18 3.0 ATA interface 21 3.1 ATA interface signals and connector pins 21...
commands 30 iv Medalist 4342, 3232, 2122, 1722 and 1012 Product Manual 1.12.2 Electromagnetic Compatibility 15 1.12.3 FCC verification 15 2.0 Drive mounting and configuration 17 2.1 Handling and static-discharge precautions 17 2.2 Jumper settings 17 2.2.1 Master/slave configuration 17 2.2.2 Alternate capacity jumper 17 2.3 Drive mounting 18 3.0 ATA interface 21 3.1 ATA interface signals and connector pins 21...
Product Manual
Page 7
Typical startup and operation current profile for the ST32122A, ST31722A and ST31012A 10 Figure 3. Alternate capacity jumper and master/slave jumpers . . . 18 Figure 4. Medalist 4342, 3232, 2122, 1722 and 1012 Product Manual v Figures Figure 1. I/O pins and supported ATA signals 22 Typical startup and operation current profile for the ST34342A and ST33232A 10 Figure 2. Mounting dimensions-top, side and end view 19 Figure 5.
Typical startup and operation current profile for the ST32122A, ST31722A and ST31012A 10 Figure 3. Alternate capacity jumper and master/slave jumpers . . . 18 Figure 4. Medalist 4342, 3232, 2122, 1722 and 1012 Product Manual v Figures Figure 1. I/O pins and supported ATA signals 22 Typical startup and operation current profile for the ST34342A and ST33232A 10 Figure 2. Mounting dimensions-top, side and end view 19 Figure 5.
Product Manual
Page 13
... Medalist 4342, 3232, 2122, 1722 and 1012 Product Manual 5 1.0 Drive specifications Unless otherwise noted, all blocks (sectors) are consecutively numbered from 0 to indicate the ST34342A, ST33232A, ST32122A, ST31722A and the ST31012A. 1.1 Formatted capacity Drive Guaranteed... Mbytes Guaranteed Model (1 Mbyte = 106 bytes) sectors (n) Bytes per track ST34342A 8,894 15 63 ST33232A 6,253 16 63 ST32122A 4,092 16 63 ST31722A 3,303 16 63 ST31012A 2,098 16 63 LBA Mode When addressing your Seagate...
... Medalist 4342, 3232, 2122, 1722 and 1012 Product Manual 5 1.0 Drive specifications Unless otherwise noted, all blocks (sectors) are consecutively numbered from 0 to indicate the ST34342A, ST33232A, ST32122A, ST31722A and the ST31012A. 1.1 Formatted capacity Drive Guaranteed... Mbytes Guaranteed Model (1 Mbyte = 106 bytes) sectors (n) Bytes per track ST34342A 8,894 15 63 ST33232A 6,253 16 63 ST32122A 4,092 16 63 ST31722A 3,303 16 63 ST31012A 2,098 16 63 LBA Mode When addressing your Seagate...
Product Manual
Page 25
... the drive's capacity to 4,092 cylinders. signal, the slave drive must monitor DASP- at power up , and the master drive must assert the DASP- Medalist 4342, 3232, 2122, 1722 and 1012 Product Manual 17 2.0 Drive mounting and configuration 2.1 Handling and static-discharge precautions After unpacking, and before installation, the drive may "hang" if their BIOS detects a hard drive that...
... the drive's capacity to 4,092 cylinders. signal, the slave drive must monitor DASP- at power up , and the master drive must assert the DASP- Medalist 4342, 3232, 2122, 1722 and 1012 Product Manual 17 2.0 Drive mounting and configuration 2.1 Handling and static-discharge precautions After unpacking, and before installation, the drive may "hang" if their BIOS detects a hard drive that...
Product Manual
Page 26
... orientation using four screws in the side-mounting holes or four screws in singleor dual-drive system Drive is more than 18 inches long. 18 Medalist 4342, 3232, 2122, 1722 and 1012 Product Manual 3 4 1 2 3 1 Alternate capacity jumper 42 Full capacity (as shipped) ATA interface pin 1 connector 4-pin power connector Master/slave jumper settings 2 46 135...
... orientation using four screws in the side-mounting holes or four screws in singleor dual-drive system Drive is more than 18 inches long. 18 Medalist 4342, 3232, 2122, 1722 and 1012 Product Manual 3 4 1 2 3 1 Alternate capacity jumper 42 Full capacity (as shipped) ATA interface pin 1 connector 4-pin power connector Master/slave jumper settings 2 46 135...
Product Manual
Page 33
...) Contents 0C5AH 22BEH (ST34342A) 186DH (ST33232A) 0FFCH (ST32122A) 0CE7H (ST31722A) 0832H (ST31012A) 2 ATA-reserved Number of the drive. Medalist 4342, 3232, 2122, 1722 and 1012 Product Manual 25 The following power up. If the alternate capacity jumper is installed on the ST34342A or the ST33232A, the drive capacity is organized as a single 512-byte block of...
...) Contents 0C5AH 22BEH (ST34342A) 186DH (ST33232A) 0FFCH (ST32122A) 0CE7H (ST31722A) 0832H (ST31012A) 2 ATA-reserved Number of the drive. Medalist 4342, 3232, 2122, 1722 and 1012 Product Manual 25 The following power up. If the alternate capacity jumper is installed on the ST34342A or the ST33232A, the drive capacity is organized as a single 512-byte block of...
Product Manual
Page 34
26 Medalist 4342, 3232, 2122, 1722 and 1012 Product Manual continued from previous page Word Description Contents 5 Retired 6 Number of...revision (8 ASCII character string, padded with blanks to end of string) x.xx 27-46 Drive model number: (40 ASCII characters, padded with blanks to end of string) ST34342A ST33232A ST32122A ST31722A or ST31012A 47 (Bits 0-7) Maximum sectors per interrupt on Read Multiple and Write ... of current logical heads 56 Number of current logical sectors per logical track 57-58 Current capacity in sectors 0000H 0100H 0200H 0007H xxxxH xxxxH xxxxH xxxxH
26 Medalist 4342, 3232, 2122, 1722 and 1012 Product Manual continued from previous page Word Description Contents 5 Retired 6 Number of...revision (8 ASCII character string, padded with blanks to end of string) x.xx 27-46 Drive model number: (40 ASCII characters, padded with blanks to end of string) ST34342A ST33232A ST32122A ST31722A or ST31012A 47 (Bits 0-7) Maximum sectors per interrupt on Read Multiple and Write ... of current logical heads 56 Number of current logical sectors per logical track 57-58 Current capacity in sectors 0000H 0100H 0200H 0007H xxxxH xxxxH xxxxH xxxxH
Product Manual
Page 37
... does not represent a feature that the drive supports. When the drive receives this command, it sets BSY, checks the contents of various features that the drive supports, the command is aborted. The acceptable... cache) feature 82H Disable write cache AAH Enable read cache) feature (default) F1H Report full capacity available At power-on, or after a hardware reset, the default values of the features are ...00H Set PIO mode to default (PIO mode 2) 01H Set PIO mode to default values. Medalist 4342, 3232, 2122, 1722 and 1012 Product Manual 29 3.2.3 Set Features command This command controls...
... does not represent a feature that the drive supports. When the drive receives this command, it sets BSY, checks the contents of various features that the drive supports, the command is aborted. The acceptable... cache) feature 82H Disable write cache AAH Enable read cache) feature (default) F1H Report full capacity available At power-on, or after a hardware reset, the default values of the features are ...00H Set PIO mode to default (PIO mode 2) 01H Set PIO mode to default values. Medalist 4342, 3232, 2122, 1722 and 1012 Product Manual 29 3.2.3 Set Features command This command controls...