Momentus 4200.2 PATA Product Manual
Page 3
... Jumper settings 17 3.2.1 Master/slave configuration 17 3.2.2 Cable-select option 18 3.3 Drive mounting 18 4.0 ATA interface 19 4.1 ATA interface signals and connector pins 19 4.1.1 Supported ATA commands 20 4.1.2 Identify Device command 23 4.1.3 Set Features command 26 5.0 Compatibility summary 27 5.1 Installation considerations 27 5.2 System Compatibility 28 5.3 BIOS versions tested 29 5.4 Operating system versions tested 30 5.5 Compatibility test configurations 30 5.6 Software utilities 30 5.7 Other certification 30 6.0 Seagate Technology support services 31 Momentus 4200...
... Jumper settings 17 3.2.1 Master/slave configuration 17 3.2.2 Cable-select option 18 3.3 Drive mounting 18 4.0 ATA interface 19 4.1 ATA interface signals and connector pins 19 4.1.1 Supported ATA commands 20 4.1.2 Identify Device command 23 4.1.3 Set Features command 26 5.0 Compatibility summary 27 5.1 Installation considerations 27 5.2 System Compatibility 28 5.3 BIOS versions tested 29 5.4 Operating system versions tested 30 5.5 Compatibility test configurations 30 5.6 Software utilities 30 5.7 Other certification 30 6.0 Seagate Technology support services 31 Momentus 4200...
Momentus 4200.2 PATA Product Manual
Page 7
... diagnostic software performs a drive self-test that eliminates unnecessary drive returns. • Support for autodetection of -the-art cache and on models ST950212A, ST9402113A and ST930219A. • Quiet operation. Momentus 4200.2 PATA disc drive Momentus 4200.2 Product Manual, Rev. Fluid Dynamic Bearing (FDB) motor. • High instantaneous (burst) data transfer rates (up to 100 Mbytes per second) using Ultra DMA mode 5. • Tunneling Magnetoresistive (TMR) recording heads. • State-of master/slave drives that use cable select (CSEL). Figure 1. drive monitoring...
... diagnostic software performs a drive self-test that eliminates unnecessary drive returns. • Support for autodetection of -the-art cache and on models ST950212A, ST9402113A and ST930219A. • Quiet operation. Momentus 4200.2 PATA disc drive Momentus 4200.2 Product Manual, Rev. Fluid Dynamic Bearing (FDB) motor. • High instantaneous (burst) data transfer rates (up to 100 Mbytes per second) using Ultra DMA mode 5. • Tunneling Magnetoresistive (TMR) recording heads. • State-of master/slave drives that use cable select (CSEL). Figure 1. drive monitoring...
Momentus 4200.2 PATA Product Manual
Page 9
... Areal density (Gbits/inch2 max) Spindle speed (RPM) Internal data transfer rate OD (Mbytes/sec max) I/O data-transfer rate (Mbytes/sec max) ATA data-transfer modes supported Height Width Length Weight (typical) Average latency (msec) Power-on specification measurement or definition, see the appropriate section of this manual. 2.0 Drive specifications Unless otherwise noted, all specifications are used throughout this manual to -track seek time (msec typical) ST9100822A ST9808210A ST960821A ST950212A ST9402113A ST930219A 100 80 60 50 40 30 195...
... Areal density (Gbits/inch2 max) Spindle speed (RPM) Internal data transfer rate OD (Mbytes/sec max) I/O data-transfer rate (Mbytes/sec max) ATA data-transfer modes supported Height Width Length Weight (typical) Average latency (msec) Power-on specification measurement or definition, see the appropriate section of this manual. 2.0 Drive specifications Unless otherwise noted, all specifications are used throughout this manual to -track seek time (msec typical) ST9100822A ST9808210A ST960821A ST950212A ST9402113A ST930219A 100 80 60 50 40 30 195...
Momentus 4200.2 PATA Product Manual
Page 10
...) Average seek, write (msec typical) Full-stroke seek (msec) Seek power (typical) Read/write power (typical) Idle mode (typical) Standby mode Sleep mode Voltage tolerance (including noise) Ambient temperature Temperature gradient (°C per hour max, noncondensing) Relative humidity (noncondensing) Relative humidity gradient Wet bulb temperature (°C max) Altitude, operating Altitude, nonoperating (below 22 hz) Drive acoustics, sound power (bels) Idle* Quiet seek Performance seek Nonrecoverable read errors Mean time between failures (MTBF) ST9100822A ST9808210A ST960821A ST950212A...
...) Average seek, write (msec typical) Full-stroke seek (msec) Seek power (typical) Read/write power (typical) Idle mode (typical) Standby mode Sleep mode Voltage tolerance (including noise) Ambient temperature Temperature gradient (°C per hour max, noncondensing) Relative humidity (noncondensing) Relative humidity gradient Wet bulb temperature (°C max) Altitude, operating Altitude, nonoperating (below 22 hz) Drive acoustics, sound power (bels) Idle* Quiet seek Performance seek Nonrecoverable read errors Mean time between failures (MTBF) ST9100822A ST9808210A ST960821A ST950212A...
Momentus 4200.2 PATA Product Manual
Page 11
... ST930219A Formatted capacity 100 Gbytes 80 Gbytes 60 Gbytes 50 Gbytes 40 Gbytes 30 Gbytes Guaranteed sectors 195,371,568 156,301,488 117,210,240 97,696,368 78,140,160 58,605,120 Bytes per sector 512 512 512 512 512 512 2.3 Default logical geometry Cylinders 16,383 Read/write heads 16 Sectors per track 63 LBA mode When addressing these drives in LBA mode...
... ST930219A Formatted capacity 100 Gbytes 80 Gbytes 60 Gbytes 50 Gbytes 40 Gbytes 30 Gbytes Guaranteed sectors 195,371,568 156,301,488 117,210,240 97,696,368 78,140,160 58,605,120 Bytes per sector 512 512 512 512 512 512 2.3 Default logical geometry Cylinders 16,383 Read/write heads 16 Sectors per track 63 LBA mode When addressing these drives in LBA mode...
Momentus 4200.2 PATA Product Manual
Page 12
... TPI (tracks/inch typical) Areal density (Mbits/inch2 max) Spindle speed (RPM) (± 0.2%) Internal data-transfer rate OD (Mbytes/sec max) I/O data-transfer rate (Mbytes/sec max) Interleave Cache buffer Specification Parallel ATA RLL 0,11 703,000 115,000 86 4,200 RPM-Class Performance (Actual spin speed 5,400 RPM) 48.25 100 (Ultra DMA mode 5) 1:1 8 Mbytes (8,184 kbytes) on ST9100822A, ST9808210A and ST960821A 2 Mbytes (2,048 kbytes) on ST950212A, ST9402113A, and ST930219A...
... TPI (tracks/inch typical) Areal density (Mbits/inch2 max) Spindle speed (RPM) (± 0.2%) Internal data-transfer rate OD (Mbytes/sec max) I/O data-transfer rate (Mbytes/sec max) Interleave Cache buffer Specification Parallel ATA RLL 0,11 703,000 115,000 86 4,200 RPM-Class Performance (Actual spin speed 5,400 RPM) 48.25 100 (Ultra DMA mode 5) 1:1 8 Mbytes (8,184 kbytes) on ST9100822A, ST9808210A and ST960821A 2 Mbytes (2,048 kbytes) on ST950212A, ST9402113A, and ST930219A...
Momentus 4200.2 PATA Product Manual
Page 13
... power at least 5,000 measurements of mode (such as track-to-track and average), are expected to Ready (sec) 3.0 8.0 Momentus 4200.2 Product Manual, Rev. Typical seek times (msec)* Track-to consistently meet or exceed the noted values. These drives are defined as follows: • Track-to-track seek time is an average of all possible single-track seeks in this manual. All times are formatted, benchmark tests...
... power at least 5,000 measurements of mode (such as track-to-track and average), are expected to Ready (sec) 3.0 8.0 Momentus 4200.2 Product Manual, Rev. Typical seek times (msec)* Track-to consistently meet or exceed the noted values. These drives are defined as follows: • Track-to-track seek time is an average of all possible single-track seeks in this manual. All times are formatted, benchmark tests...
Momentus 4200.2 PATA Product Manual
Page 16
.... 2.9.4 Power-management modes The drive provides programmable power management to Active mode when disc access is reinitialized and begins counting down from the host. After receiving a reset, the drive exits Sleep mode and enters Standby mode with all current translation parameters intact. • Idle and Standby timers Each time the drive performs an Active function (read /write and seek operations. • Idle mode The buffer remains enabled, and the drive accepts all commands...
.... 2.9.4 Power-management modes The drive provides programmable power management to Active mode when disc access is reinitialized and begins counting down from the host. After receiving a reset, the drive exits Sleep mode and enters Standby mode with all current translation parameters intact. • Idle and Standby timers Each time the drive performs an Active function (read /write and seek operations. • Idle mode The buffer remains enabled, and the drive accepts all commands...
Momentus 4200.2 PATA Product Manual
Page 20
....2 Electromagnetic compatibility Hard drives that all unused I /O cable (if necessary) and terminators on /off cycles 5 Years 5 Years 2.14 Agency certification 2.14.1 Safety certification The drives are tested in representative end-user systems. Although CE-marked Seagate drives comply with the directives when used in the previous paragraph. Max case temperature: 65°C at the case measurement location shown in Figure 4 600,000 software-controlled power on/off...
....2 Electromagnetic compatibility Hard drives that all unused I /O cable (if necessary) and terminators on /off cycles 5 Years 5 Years 2.14 Agency certification 2.14.1 Safety certification The drives are tested in representative end-user systems. Although CE-marked Seagate drives comply with the directives when used in the previous paragraph. Max case temperature: 65°C at the case measurement location shown in Figure 4 600,000 software-controlled power on/off...
Momentus 4200.2 PATA Product Manual
Page 21
... occur in enclosures as an external device). This equipment generates and uses radio frequency energy and if not installed and used in a representative, end-user system by turning the equipment on different branch outlets. If this device in a particular installation. D 15 ST9808210A, ST960821A, ST950212A, ST9402113A and ST930219A. • Certificate numbers: Pending • Trade name or applicant: Seagate Technology • Manufacturing date: August 2004...
... occur in enclosures as an external device). This equipment generates and uses radio frequency energy and if not installed and used in a representative, end-user system by turning the equipment on different branch outlets. If this device in a particular installation. D 15 ST9808210A, ST960821A, ST950212A, ST9402113A and ST930219A. • Certificate numbers: Pending • Trade name or applicant: Seagate Technology • Manufacturing date: August 2004...
Momentus 4200.2 PATA Product Manual
Page 23
Removal voids the warranty. Jumper settings Momentus 4200.2 Product Manual, Rev. Drive is master (or single drive) Drive is the factory default setting. This jumper block is the 4pin header adjacent to service the drive. Do not press down on the drive top cover. • Always rest the drive on a padded, antistatic surface until you are used to seal out dirt and contamination. 3.2 Jumper settings 3.2.1 Master/slave configuration Use the options jumper block shown in Figure 3 to potential handling...
Removal voids the warranty. Jumper settings Momentus 4200.2 Product Manual, Rev. Drive is master (or single drive) Drive is the factory default setting. This jumper block is the 4pin header adjacent to service the drive. Do not press down on the drive top cover. • Always rest the drive on a padded, antistatic surface until you are used to seal out dirt and contamination. 3.2 Jumper settings 3.2.1 Master/slave configuration Use the options jumper block shown in Figure 3 to potential handling...
Momentus 4200.2 PATA Product Manual
Page 24
... (17.09 +/- .254) Recommended case temp. Mounting dimensions-top, side and end view 18 2X M3 X 0.5-6H Mounting holes Both sides .12 min. D 3.2.2 Cable-select option Computers that use cable select determine the master and slave drives by their physical position on the interface bus. Master and slave drives are determined by selecting or deselecting pin 28, CSEL, on the cable. To enable cable select, set a jumper as shown in Figure...
... (17.09 +/- .254) Recommended case temp. Mounting dimensions-top, side and end view 18 2X M3 X 0.5-6H Mounting holes Both sides .12 min. D 3.2.2 Cable-select option Computers that use cable select determine the master and slave drives by their physical position on the interface bus. Master and slave drives are determined by selecting or deselecting pin 28, CSEL, on the cable. To enable cable select, set a jumper as shown in Figure...
Momentus 4200.2 PATA Product Manual
Page 26
...ATA Device Configuration Overlay ATA Service Check Power Mode Download Microcode Execute Device Diagnostics Flush Cache Flush Cache Extended Format Track (Legacy) Identify Device Idle Idle Immediate Initialize Device Parameters Read Buffer Read DMA Read DMA Extended Read Log Extended Read Multiple Read Multiple Extended Read Native Max Address Read Native Max Address Extended Read Sectors Read Sectors Extended Read Verify Sectors Read Verify Sectors Extended Recalibrate Security Disable Password Security Erase Prepare Security Erase Unit Security Freeze Lock Security Set Password Command code...
...ATA Device Configuration Overlay ATA Service Check Power Mode Download Microcode Execute Device Diagnostics Flush Cache Flush Cache Extended Format Track (Legacy) Identify Device Idle Idle Immediate Initialize Device Parameters Read Buffer Read DMA Read DMA Extended Read Log Extended Read Multiple Read Multiple Extended Read Native Max Address Read Native Max Address Extended Read Sectors Read Sectors Extended Read Verify Sectors Read Verify Sectors Extended Recalibrate Security Disable Password Security Erase Prepare Security Erase Unit Security Freeze Lock Security Set Password Command code...
Momentus 4200.2 PATA Product Manual
Page 29
4.1.2 Identify Device command The Identify Device command (command code ECH) transfers information about the drive to the host following commands contain drive-specific features that may be disabled ATA-reserved PIO data-transfer cycle timing mode Retired Words 54-58, 64-70 and 88 are valid Number of current logical cylinders Number of current logical heads Number of data, whose contents are drive-specific or vary with the state of the drive. See Section 2.0 on page 20. Word...
4.1.2 Identify Device command The Identify Device command (command code ECH) transfers information about the drive to the host following commands contain drive-specific features that may be disabled ATA-reserved PIO data-transfer cycle timing mode Retired Words 54-58, 64-70 and 88 are valid Number of current logical cylinders Number of current logical heads Number of data, whose contents are drive-specific or vary with the state of the drive. See Section 2.0 on page 20. Word...
Momentus 4200.2 PATA Product Manual
Page 30
...word (120 nsec) Minimum PIO cycle time without IORDY flow control (240 nsec) Minimum PIO cycle time with IORDY flow control (120 nsec) ATA-reserved Queue depth ATA-reserved Major version number Minor version number Command sets supported Command sets supported Command sets support extension Command sets enabled Command sets enabled Command sets enable extension Ultra DMA support and current mode (see note following this table) Security erase time Enhanced security erase time Advanced power management value Master password revision code Hardware reset value (see description following this table...
...word (120 nsec) Minimum PIO cycle time without IORDY flow control (240 nsec) Minimum PIO cycle time with IORDY flow control (120 nsec) ATA-reserved Queue depth ATA-reserved Major version number Minor version number Command sets supported Command sets supported Command sets support extension Command sets enabled Command sets enabled Command sets enable extension Ultra DMA support and current mode (see note following this table) Security erase time Enhanced security erase time Advanced power management value Master password revision code Hardware reset value (see description following this table...
Momentus 4200.2 PATA Product Manual
Page 33
...'s support website for the end user to replace the hard drive. Momentus 4200.2 Product Manual, Rev. Refer to the hard drive. Read and follow all instructions regarding replacement. Seagate recommends taking your system to an authorized service technician to be needed to your system's user manual for the location of today's mobile computers have been designed to make it possible for the most up-todate information. Refer to service some cases, opening the case may...
...'s support website for the end user to replace the hard drive. Momentus 4200.2 Product Manual, Rev. Refer to the hard drive. Read and follow all instructions regarding replacement. Seagate recommends taking your system to an authorized service technician to be needed to your system's user manual for the location of today's mobile computers have been designed to make it possible for the most up-todate information. Refer to service some cases, opening the case may...
Momentus 4200.2 PATA Product Manual
Page 36
... operating systems have been tested to troubleshoot most ATA, SATA, or SCSI drives in desktop systems and has a 98 percent accuracy rate. These tests were preformed to ensure the functionality to ATA/ATAPI-6 specifications and the compatibility of Seagate Momentus drives with other ATA/ATAPI-6 compliant peripherals. 5.6 Software utilities The following is a brief overview of a some of the Seagate utilities used in both the master drive and slave drive positions. This is an exclusive disc drive diagnostic software...
... operating systems have been tested to troubleshoot most ATA, SATA, or SCSI drives in desktop systems and has a 98 percent accuracy rate. These tests were preformed to ensure the functionality to ATA/ATAPI-6 specifications and the compatibility of Seagate Momentus drives with other ATA/ATAPI-6 compliant peripherals. 5.6 Software utilities The following is a brief overview of a some of the Seagate utilities used in both the master drive and slave drive positions. This is an exclusive disc drive diagnostic software...
Momentus 4200.2 PATA Product Manual
Page 38
..., go to the "Contact Us" page on www.seagate.com. Resellers or end users of drive products should contact their place of defective products. Our data recovery services labs are available on www.seagate.com. 32 Momentus 4200.2 Product Manual, Rev. Have your customer support representative for all formats and all brands of telephone numbers to technical support, presales and warranty service in Asia/Pacific, go to the "Contact Us...
..., go to the "Contact Us" page on www.seagate.com. Resellers or end users of drive products should contact their place of defective products. Our data recovery services labs are available on www.seagate.com. 32 Momentus 4200.2 Product Manual, Rev. Have your customer support representative for all formats and all brands of telephone numbers to technical support, presales and warranty service in Asia/Pacific, go to the "Contact Us...
Momentus 4200.2 PATA Product Manual
Page 39
... seek time 7 B BIOS manufacturers 29 BPI 6 buffer 1, 6 burst 1 C cable select 1 cable-select option 18 cache 1, 6 case temperature 11 CE mark 14 certification 14 Check Power Mode 21 commands 20 compatibility 28 compatibility summary 27 compatibility test configurations 30 compliance 14 conducted noise 9 conducted RF immunity 13 configuring the drive 17 connector pins 19 CSA C22.2 (950) 14 CSEL 18 C-Tick 15 current profile 9 cycles 14 D data-transfer rates 1 DC power 8 demonstrate compliance 30 density 6 diagnostic software 1 discs 5 Momentus 4200.2 Product Manual, Rev...
... seek time 7 B BIOS manufacturers 29 BPI 6 buffer 1, 6 burst 1 C cable select 1 cable-select option 18 cache 1, 6 case temperature 11 CE mark 14 certification 14 Check Power Mode 21 commands 20 compatibility 28 compatibility summary 27 compatibility test configurations 30 compliance 14 conducted noise 9 conducted RF immunity 13 configuring the drive 17 connector pins 19 CSA C22.2 (950) 14 CSEL 18 C-Tick 15 current profile 9 cycles 14 D data-transfer rates 1 DC power 8 demonstrate compliance 30 density 6 diagnostic software 1 discs 5 Momentus 4200.2 Product Manual, Rev...
Momentus 4200.2 PATA Product Manual
Page 40
... Lock 22 Security Set Password 21 Security Unlock 21 Seek 21 seek mode 8 seek time 7 Momentus 4200.2 Product Manual, Rev. D interface signals 19 interference 15 interleave 6 internal data-transfer rate OD 6 ISO document 7779 13 J jumper settings 17 K Korean RRL 15 L LBA mode 5 length 6 Load/Unload 14 logical geometry 5 M master/slave 1 Master/slave configuration 17 maximum temperature 11 Mean time between failures 4, 14 modes 19 monitoring 1 mounting the drive 17, 18 MTBF 4, 14 N noise 9 nominal power 3 nonoperating shock 12 nonoperating vibration 12 nonrecoverable read errors 14 O operating...
... Lock 22 Security Set Password 21 Security Unlock 21 Seek 21 seek mode 8 seek time 7 Momentus 4200.2 Product Manual, Rev. D interface signals 19 interference 15 interleave 6 internal data-transfer rate OD 6 ISO document 7779 13 J jumper settings 17 K Korean RRL 15 L LBA mode 5 length 6 Load/Unload 14 logical geometry 5 M master/slave 1 Master/slave configuration 17 maximum temperature 11 Mean time between failures 4, 14 modes 19 monitoring 1 mounting the drive 17, 18 MTBF 4, 14 N noise 9 nominal power 3 nonoperating shock 12 nonoperating vibration 12 nonrecoverable read errors 14 O operating...