Instructions for Use
Page 2
... 19 Using the ADN Cable Calculator software 20 System requirements 20 Installing the ADN Cable Calculator 20 Using the ADN Cable Calculator 22 Deinstalling the ADN Cable Calculator 22 Putting the conference system into operation 23 Preparing the ADN CU1 central unit for use 23 Preparing the ADN PS power supply for use 25 Preparing the ADN C1/ADN D1 conference units for use 27 Setting up the conference system 29 Connecting external audio devices to the central unit 39 Connecting a USB...
... 19 Using the ADN Cable Calculator software 20 System requirements 20 Installing the ADN Cable Calculator 20 Using the ADN Cable Calculator 22 Deinstalling the ADN Cable Calculator 22 Putting the conference system into operation 23 Preparing the ADN CU1 central unit for use 23 Preparing the ADN PS power supply for use 25 Preparing the ADN C1/ADN D1 conference units for use 27 Setting up the conference system 29 Connecting external audio devices to the central unit 39 Connecting a USB...
Instructions for Use
Page 3
... the Windows version of the software for use 81 Starting/exiting the software 87 Getting to know and adjusting the basic features of the conference system 149 If a problem occurs 150 Accessories ...154 Specifications ...155 Appendix ...157 Manufacturer Declarations 163 Index ...164 2 | ADN Digital Conference System "Setup" operating mode 122 Adjusting the conference settings - "Conference Recording 141 Using the log and diagnosis function - "Setup" operating mode 106 Initializing the conference units - "Setup" operating mode 126 Controlling...
... the Windows version of the software for use 81 Starting/exiting the software 87 Getting to know and adjusting the basic features of the conference system 149 If a problem occurs 150 Accessories ...154 Specifications ...155 Appendix ...157 Manufacturer Declarations 163 Index ...164 2 | ADN Digital Conference System "Setup" operating mode 122 Adjusting the conference settings - "Conference Recording 141 Using the log and diagnosis function - "Setup" operating mode 106 Initializing the conference units - "Setup" operating mode 126 Controlling...
Instructions for Use
Page 8
... be used in a conference system) • SDC CBL RJ-45 system cables (available in different lengths) • ADN PS power supplies (optional, for conferences with up to a max. can be run on a separate Windows PC with Ethernet connection • USB mass storage device for audio recording of conferences (optional) • REC ADN CU1 "Conference Manager" software Conferences with up to 400 conference units connected...
... be used in a conference system) • SDC CBL RJ-45 system cables (available in different lengths) • ADN PS power supplies (optional, for conferences with up to a max. can be run on a separate Windows PC with Ethernet connection • USB mass storage device for audio recording of conferences (optional) • REC ADN CU1 "Conference Manager" software Conferences with up to 400 conference units connected...
Instructions for Use
Page 9
Overview of the components ADN D1 delegate unit ³ · ¾ º µ¸ ¶² ³ Sound inlet basket with firmly fixed windshield · Signal light ring » Headphone socket ² Headphone volume control for headphone socket ¶ Microphone key º Microphone LED ¾ Loudspeaker » µ IN socket ¸ OUT socket 8 | ADN Digital Conference System
Overview of the components ADN D1 delegate unit ³ · ¾ º µ¸ ¶² ³ Sound inlet basket with firmly fixed windshield · Signal light ring » Headphone socket ² Headphone volume control for headphone socket ¶ Microphone key º Microphone LED ¾ Loudspeaker » µ IN socket ¸ OUT socket 8 | ADN Digital Conference System
Instructions for Use
Page 16
... between the central unit or power supply and the first conference unit is 80 m max. The number of connected conference units and on the cable lengths. The standard cable length between the individual conference units is 2 to 5 m. per ADN PS power supply - 60-70 conference units connected in simple strings - 30-40 conference units connected in ring topology per conference system. ADN D1 delegate units and ADN C1 chairperson units can be...
... between the central unit or power supply and the first conference unit is 80 m max. The number of connected conference units and on the cable lengths. The standard cable length between the individual conference units is 2 to 5 m. per ADN PS power supply - 60-70 conference units connected in simple strings - 30-40 conference units connected in ring topology per conference system. ADN D1 delegate units and ADN C1 chairperson units can be...
Instructions for Use
Page 20
... use of the "ADN Cable Calculator" software, refer to control conferences via a graphical interface: Function Operating menu "Conference Manager" software Configuring the conference Controlling the conference via the programmable commands of your Sennheiser partner or from your media control system (see page 81). 2. For further information on the PC and integrate the PC together with the central unit in a network (see page 81). 1 2 Input and output of audio signals...
... use of the "ADN Cable Calculator" software, refer to control conferences via a graphical interface: Function Operating menu "Conference Manager" software Configuring the conference Controlling the conference via the programmable commands of your Sennheiser partner or from your media control system (see page 81). 2. For further information on the PC and integrate the PC together with the central unit in a network (see page 81). 1 2 Input and output of audio signals...
Instructions for Use
Page 22
The installation is displayed: ̈ Confirm this summary by clicking the "Next" button. ADN Digital Conference System | 21 The software has been successfully installed. Using the ADN Cable Calculator software ̈ Click the "Next" button. A selection window for specifying the installation location appears: ̈ Use the default or select an installation path. ̈ Click the "Next" button. A summary of the selected installation settings is performed and a confirmation appears: ̈ Click the "Close" button.
The installation is displayed: ̈ Confirm this summary by clicking the "Next" button. ADN Digital Conference System | 21 The software has been successfully installed. Using the ADN Cable Calculator software ̈ Click the "Next" button. A selection window for specifying the installation location appears: ̈ Use the default or select an installation path. ̈ Click the "Next" button. A summary of the selected installation settings is performed and a confirmation appears: ̈ Click the "Close" button.
Instructions for Use
Page 40
... use different settings for processing the audio signals of the IN audio input and the OUT audio output in videoconferencing or teleconferencing systems (see page 77), you require a USB mass storage device with the following characteristics: USB mass storage device Recommended memory size File system Partition Connection Interface Power supply Requirements > 500 GB NTFS FAT32 1 USB type A plug USB 2.0 via USB socket (approx. 500 mA) or separate mains unit ADN Digital...
... use different settings for processing the audio signals of the IN audio input and the OUT audio output in videoconferencing or teleconferencing systems (see page 77), you require a USB mass storage device with the following characteristics: USB mass storage device Recommended memory size File system Partition Connection Interface Power supply Requirements > 500 GB NTFS FAT32 1 USB type A plug USB 2.0 via USB socket (approx. 500 mA) or separate mains unit ADN Digital...
Instructions for Use
Page 42
... 240W B ̈ Use a network cable (Cat5) to connect the Ethernet socket B of your conference system so that you can set the on or off orange Conference units are connected in strings green Conference units are connected in redundant ring topology via output 1 and 2 flashing Error in series are also switched on and its display panel lights up your PC. ADN CU1 ADN PS ADN PS ADN PS ADN PS ESC...
... 240W B ̈ Use a network cable (Cat5) to connect the Ethernet socket B of your conference system so that you can set the on or off orange Conference units are connected in strings green Conference units are connected in redundant ring topology via output 1 and 2 flashing Error in series are also switched on and its display panel lights up your PC. ADN CU1 ADN PS ADN PS ADN PS ADN PS ESC...
Instructions for Use
Page 57
..." setting; Adjusting the processing of the floor channel increases with each additional audio signal* and tends to the floor channel ("Floor/Loudspeakers") which in turn is output via the conference units' built-in the floor channel - "-3.0 dB per Mic" ... The "Audio Gain Reduction" menu item allows you can change between the frequency ranges by pressing the jog dial. store the setting Menu item Function "Floor/Loudspeakers Volume" Adjusts the floor channel volume...
..." setting; Adjusting the processing of the floor channel increases with each additional audio signal* and tends to the floor channel ("Floor/Loudspeakers") which in turn is output via the conference units' built-in the floor channel - "-3.0 dB per Mic" ... The "Audio Gain Reduction" menu item allows you can change between the frequency ranges by pressing the jog dial. store the setting Menu item Function "Floor/Loudspeakers Volume" Adjusts the floor channel volume...
Instructions for Use
Page 79
... the "Record" menu item and select "On". store the setting 78 | ADN Digital Conference System Example: ADN/CEO-Meeting_2011-05-02_160923 File names The file names of the audio recordings consist of the following: • Floor channel: Name of the conference and starting time (date and time) Example: .../CEO-Meeting_2011-05-02_160923.wav • Conference unit channel: Type of conference unit, serial number of the conference unit, starting time of...
... the "Record" menu item and select "On". store the setting 78 | ADN Digital Conference System Example: ADN/CEO-Meeting_2011-05-02_160923 File names The file names of the audio recordings consist of the following: • Floor channel: Name of the conference and starting time (date and time) Example: .../CEO-Meeting_2011-05-02_160923.wav • Conference unit channel: Type of conference unit, serial number of the conference unit, starting time of...
Instructions for Use
Page 92
... the software System Properties** Opens the hardware settings for 97 screen, mouse and keyboard Help Help ... Toolbar c Button Function Opens the "Audio Settings" window (see page 130) Opens the "Conference Settings" window (see page 129) "Device Unlocked" "Device Locked" ADN Digital Conference System | 91 Changes to the commands. Starts the help function - About ... The Delegate View window changes depending on whether "Setup" or "Live" operating mode is set (see page 93). Conference Recording Language Set Password ... version...
... the software System Properties** Opens the hardware settings for 97 screen, mouse and keyboard Help Help ... Toolbar c Button Function Opens the "Audio Settings" window (see page 130) Opens the "Conference Settings" window (see page 129) "Device Unlocked" "Device Locked" ADN Digital Conference System | 91 Changes to the commands. Starts the help function - About ... The Delegate View window changes depending on whether "Setup" or "Live" operating mode is set (see page 93). Conference Recording Language Set Password ... version...
Instructions for Use
Page 127
"Setup" operating mode Adjusting the conference modes ̈ Click the button on the toolbar. To change the orientation/visibility of the number: ̈ Select the desired orientation from the "ID" drop-down list. Possible settings: "Direct Access", "Override", "Push To Talk" and "Request" • "Direct Access" mode and "Override" mode: These two conference modes do not require the use of speakers who can take the floor immediately. 126...
"Setup" operating mode Adjusting the conference modes ̈ Click the button on the toolbar. To change the orientation/visibility of the number: ̈ Select the desired orientation from the "ID" drop-down list. Possible settings: "Direct Access", "Override", "Push To Talk" and "Request" • "Direct Access" mode and "Override" mode: These two conference modes do not require the use of speakers who can take the floor immediately. 126...
Instructions for Use
Page 143
... the number of channels recorded, the memory capacity will suffice for approx. 15 minutes of the "Conference Managers" software logs all information on the audio recording (see page 39). ̈ In the menu bar, click "Settings" > "Conference Recording". display panel lights up red. To close the "Conference Recording" window: ̈ Click "Close". The CU1 display panel displays the status of the audio recording: Direct Access O 30 Units 22 O icon Meaning Audio recording in...
... the number of channels recorded, the memory capacity will suffice for approx. 15 minutes of the "Conference Managers" software logs all information on the audio recording (see page 39). ̈ In the menu bar, click "Settings" > "Conference Recording". display panel lights up red. To close the "Conference Recording" window: ̈ Click "Close". The CU1 display panel displays the status of the audio recording: Direct Access O 30 Units 22 O icon Meaning Audio recording in...
Instructions for Use
Page 152
.... as NTFS or FAT32 file system Connect the external power supply of speaking privileges. The data transmission speed is deactivated. Use a USB mass storage device with - ADN Digital Conference System | 151 Use a shielded USB cable. - Set a conference mode which does not require the grant of - A further speaker has made speak has been reached. The speaking time limit is too high. not flash when a request to grant speaking...
.... as NTFS or FAT32 file system Connect the external power supply of speaking privileges. The data transmission speed is deactivated. Use a USB mass storage device with - ADN Digital Conference System | 151 Use a shielded USB cable. - Set a conference mode which does not require the grant of - A further speaker has made speak has been reached. The speaking time limit is too high. not flash when a request to grant speaking...
Instructions for Use
Page 153
... operation. Check the conference system for a cabling error. Problem The number of conference units displayed does not correspond to the number of different ADN PS power supplies Ring topology connected to the conference system during switch the conference system on again (see page 41). A cabling error has occurred. DATA socket of an ADN PS power supply connected to a PORT socket of an ADN PS power supply Ring topology connected to different PORT sockets of an ADN PS power supply...
... operation. Check the conference system for a cabling error. Problem The number of conference units displayed does not correspond to the number of different ADN PS power supplies Ring topology connected to the conference system during switch the conference system on again (see page 41). A cabling error has occurred. DATA socket of an ADN PS power supply connected to a PORT socket of an ADN PS power supply Ring topology connected to different PORT sockets of an ADN PS power supply...
Instructions for Use
Page 154
.../or a firewall. If a problem occurs ... There is installed on the Windows PC. Screen connected to the Check the network settings and adjust 84 PC and/or the central unit. conf service is already a connection to the Disconnect the connection to 93 mode. Improper IP address allocation to the The screen resolution is not listed in "Live" operating Change to "Setup" operating mode to the 101 central unit. Password forgotten − Delete the...
.../or a firewall. If a problem occurs ... There is installed on the Windows PC. Screen connected to the Check the network settings and adjust 84 PC and/or the central unit. conf service is already a connection to the Disconnect the connection to 93 mode. Improper IP address allocation to the The screen resolution is not listed in "Live" operating Change to "Setup" operating mode to the 101 central unit. Password forgotten − Delete the...
Instructions for Use
Page 165
... flashing of the signal light ring when a request to speak is made 128 Adding conference units 77 ADN C1, see Chairperson unit ADN Cable Calculator 20 deinstallling the software 22 installing the software 20 system requirements 20 using the software 22 ADN CU1 display panel, see Display panel ADN CU1, see ADN CU1 central unit ADN PS power supply overview 13 status LEDs 13 ADN PS, see ADN PS power supply Advance warning time adjusting 53, 128 Audio devices connecting...
... flashing of the signal light ring when a request to speak is made 128 Adding conference units 77 ADN C1, see Chairperson unit ADN Cable Calculator 20 deinstallling the software 22 installing the software 20 system requirements 20 using the software 22 ADN CU1 display panel, see Display panel ADN CU1, see ADN CU1 central unit ADN PS power supply overview 13 status LEDs 13 ADN PS, see ADN PS power supply Advance warning time adjusting 53, 128 Audio devices connecting...
Instructions for Use
Page 166
... structural change icon 59 warning triangle 59 Error Indication resetting 67 Error indication 66 Errors current and power supply 64 detecting and eliminating 59, 150 eliminating connection problems 101 resetting Error Indication 67 resetting the counter 67 short-circuit 64 system analysis 64 system bus errors 66 temperature 65 F Factory default settings 71, 158 Feedback eliminating 57, 132 Feedback Suppression 57, 132 Firmware 149 Floor channel adjusting audio settings 56, 130 ADN Digital...
... structural change icon 59 warning triangle 59 Error Indication resetting 67 Error indication 66 Errors current and power supply 64 detecting and eliminating 59, 150 eliminating connection problems 101 resetting Error Indication 67 resetting the counter 67 short-circuit 64 system analysis 64 system bus errors 66 temperature 65 F Factory default settings 71, 158 Feedback eliminating 57, 132 Feedback Suppression 57, 132 Firmware 149 Floor channel adjusting audio settings 56, 130 ADN Digital...
Instructions for Use
Page 167
... speakers adjusting 51, 127 Media control system 19 connecting 42 connecting to the central unit 43 programming 43 using 42 Mic Loudspeaker Mute 58, 131 Microphone activating 73 deactivating 73 Microphone Limit 51, 127 N Network settings 70, 98 configuring Windows 84 dynamic IP addressing 86, 98 static IP addressing 87, 98 Number of connected conference units 63 O Operating menu functionality 19 operating principles 49 Operating mode buttons 92 "Live" 133 "Setup" 122 Override 50 166 | ADN Digital...
... speakers adjusting 51, 127 Media control system 19 connecting 42 connecting to the central unit 43 programming 43 using 42 Mic Loudspeaker Mute 58, 131 Microphone activating 73 deactivating 73 Microphone Limit 51, 127 N Network settings 70, 98 configuring Windows 84 dynamic IP addressing 86, 98 static IP addressing 87, 98 Number of connected conference units 63 O Operating menu functionality 19 operating principles 49 Operating mode buttons 92 "Live" 133 "Setup" 122 Override 50 166 | ADN Digital...