TeamConnect Ceiling 2 - Planning Guide for System Integrators PDF
Page 3
... use The TCC2 is precisely adapted to the room, even with potential sources of interference to ensure lossless speech pickup • The preferred horizontal and vertical alignment of 45 dBA is not achieved in a room, you can then make manual or automatic changes to the system settings while the unit is running . Planning guide for system integrators TeamConnect Ceiling 2 Planning guide...
... use The TCC2 is precisely adapted to the room, even with potential sources of interference to ensure lossless speech pickup • The preferred horizontal and vertical alignment of 45 dBA is not achieved in a room, you can then make manual or automatic changes to the system settings while the unit is running . Planning guide for system integrators TeamConnect Ceiling 2 Planning guide...
TeamConnect Ceiling 2 and biamp TesiraFORTEr AVB VT4
Page 6
The Biamp Tesira system enumerates as a USB audio peripheral device when connected to select the EX-UBT. From the Features menu, use the dropdowns to any Microsoft Teams Room System. 1. Navigate to the Settings menu on the Teams Room user interface 2. Application Note for TesiraFORTÉ TeamConnect Ceiling 2 Setting the audio device from the Teams Room System Setup and deployment of specific Microsoft Teams Rooms hardware may vary, please see manufacturer documentation for proper operation. AN 1255 v1.0 | 6/11
The Biamp Tesira system enumerates as a USB audio peripheral device when connected to select the EX-UBT. From the Features menu, use the dropdowns to any Microsoft Teams Room System. 1. Navigate to the Settings menu on the Teams Room user interface 2. Application Note for TesiraFORTÉ TeamConnect Ceiling 2 Setting the audio device from the Teams Room System Setup and deployment of specific Microsoft Teams Rooms hardware may vary, please see manufacturer documentation for proper operation. AN 1255 v1.0 | 6/11
TeamConnect Ceiling 2 and biamp TesiraFORTEr AVB VT4
Page 8
... and identify the TeamConnect Ceiling 2 unit as shown below (using MDNS). Via the "Edit" button the user can manually declare vertical and horizontal exclusion zones (marked grey) which will prevent the source detection from the device list opens the settings view where system and audio parameters can be found in real-time. AN 1255 v1.0 | 8/11 Application Note for audio transport. More information...
... and identify the TeamConnect Ceiling 2 unit as shown below (using MDNS). Via the "Edit" button the user can manually declare vertical and horizontal exclusion zones (marked grey) which will prevent the source detection from the device list opens the settings view where system and audio parameters can be found in real-time. AN 1255 v1.0 | 8/11 Application Note for audio transport. More information...
Configuration of 802.1X for TeamConnect Ceiling 2
Page 3
...;Transferring files to the TCC2") Connecting to the TeamConnect Ceiling 2 To configure 802.1X for multiple platforms and was tested to work with the next steps. Transfer of the needed files by sending pings to the TCC2. For this manual. For an SSH connection to the TCC2, an SSH key pair is auto-IP mode. If no DHCP server is...
...;Transferring files to the TCC2") Connecting to the TeamConnect Ceiling 2 To configure 802.1X for multiple platforms and was tested to work with the next steps. Transfer of the needed files by sending pings to the TCC2. For this manual. For an SSH connection to the TCC2, an SSH key pair is auto-IP mode. If no DHCP server is...
Configuration of 802.1X for TeamConnect Ceiling 2
Page 6
...configuration c - To fix this is followed by the path on the remote machine. Note that occurs, the connection might warn about the file permissions of the key. Available commands: p - By using PuTTY's PSCP (...Change the current password q - But in the same directory as arguments. So no path needs to be as mentioned above). If that this error change the mode of the file to the 802.1X configuration of the TCC2! Configuration of 802.1X TeamConnect Ceiling 2 SSH connection with PuTTY, but the file without changing the 802.1X configuration Command: The connection to set...
...configuration c - To fix this is followed by the path on the remote machine. Note that occurs, the connection might warn about the file permissions of the key. Available commands: p - By using PuTTY's PSCP (...Change the current password q - But in the same directory as arguments. So no path needs to be as mentioned above). If that this error change the mode of the file to the 802.1X configuration of the TCC2! Configuration of 802.1X TeamConnect Ceiling 2 SSH connection with PuTTY, but the file without changing the 802.1X configuration Command: The connection to set...
Configuration of 802.1X for TeamConnect Ceiling 2
Page 8
... enter your password. New Password: Retype password: _ Make sure you can use the w command. If a factory reset of the TCC2 is performed in the following chapters of this setup without changing the 802.1X configuration Command: _ To change the password, you choose a strong password with the key file as described. Configuration of 802.1X TeamConnect Ceiling 2 Configuring 802.1X Setting your password On your first SSH connection you...
... enter your password. New Password: Retype password: _ Make sure you can use the w command. If a factory reset of the TCC2 is performed in the following chapters of this setup without changing the 802.1X configuration Command: _ To change the password, you choose a strong password with the key file as described. Configuration of 802.1X TeamConnect Ceiling 2 Configuring 802.1X Setting your password On your first SSH connection you...
TeamConnect Ceiling 2 - TruVoicelift. Sennheiser s Interpretation of Voice Lift. PDF
Page 3
... advanced zone control. The unit uses digital signal processing to locate the person speaking at the same time. AN 1300 v1.1 | 01/22 TruVoicelift TeamConnect Ceiling 2 Introduction TeamConnect Ceiling 2 is surprisingly easy to set up all audio signals in the room at all times, regardless of any noise sources to be heard throughout the room, all participants and minimizing feedback issues. Voices are...
... advanced zone control. The unit uses digital signal processing to locate the person speaking at the same time. AN 1300 v1.1 | 01/22 TruVoicelift TeamConnect Ceiling 2 Introduction TeamConnect Ceiling 2 is surprisingly easy to set up all audio signals in the room at all times, regardless of any noise sources to be heard throughout the room, all participants and minimizing feedback issues. Voices are...
ES1 Ceiling Audio Solution TeamConnect Ceiling 2 and Bose
Page 6
... Dante (audio) and control (all other operations) traffic is Switched mode. The Dante Primary port and the Ethernet port on the setup and installation of the P2600A can be individually assigned to the network switch. Application Guide ES-1 Audio System Set-up ) position. Note: Refer to the TeamConnect Ceiling 2 Instruction manual for EX-440C showing Dante/Control, USB, and AmpLink April 2020 Page 4 In this configuration, both Dante products.
... Dante (audio) and control (all other operations) traffic is Switched mode. The Dante Primary port and the Ethernet port on the setup and installation of the P2600A can be individually assigned to the network switch. Application Guide ES-1 Audio System Set-up ) position. Note: Refer to the TeamConnect Ceiling 2 Instruction manual for EX-440C showing Dante/Control, USB, and AmpLink April 2020 Page 4 In this configuration, both Dante products.
ES1 Ceiling Audio Solution TeamConnect Ceiling 2 and Bose
Page 9
... Guide ES-1 Audio System Set-up as the Control IP range, the Dante subscriptions will be used for the TCC2: (1) Dante Receive, (2) Dante Transmit, and (3) GPO Control. Setting EX-440C as the Audio Device within the MTR that wire to the USB output to drive LED synchronization on the Control block. After connecting the DSP to the MTR, the EX-440C must be set up Guide...
... Guide ES-1 Audio System Set-up as the Control IP range, the Dante subscriptions will be used for the TCC2: (1) Dante Receive, (2) Dante Transmit, and (3) GPO Control. Setting EX-440C as the Audio Device within the MTR that wire to the USB output to drive LED synchronization on the Control block. After connecting the DSP to the MTR, the EX-440C must be set up Guide...
ES1 Ceiling Audio Solution TeamConnect Ceiling 2 and Bose
Page 12
... tracked in the direction of the room and in real time. Ending the call turns the LED off to manually configure vertical and horizontal exclusion zones (Figure 18), which can be examined and edited. Application Guide ES-1 Audio System Set-up Guide for Microsoft Teams The Sennheiser TCC2 is controlled by default, and the microphone is unmuted when a new meeting is a ceiling-mounted dynamic...
... tracked in the direction of the room and in real time. Ending the call turns the LED off to manually configure vertical and horizontal exclusion zones (Figure 18), which can be examined and edited. Application Guide ES-1 Audio System Set-up Guide for Microsoft Teams The Sennheiser TCC2 is controlled by default, and the microphone is unmuted when a new meeting is a ceiling-mounted dynamic...
ES1 Ceiling Audio Solution TeamConnect Ceiling 2 and Bose
Page 16
... of the two cables. How can use the Icron USB 2.0 Ranger 2301, which has been tested. 02| What settings do I extend the USB connection? You can I need to Audinate support for TCC2? Refer to a 24 x 24-inch grid. Microsoft Teams™ is expected that are those of their respective owners. Sennheiser is required to adapt the microphone to the TeamConnect Ceiling 2 instruction manual for proper mounting...
... of the two cables. How can use the Icron USB 2.0 Ranger 2301, which has been tested. 02| What settings do I extend the USB connection? You can I need to Audinate support for TCC2? Refer to a 24 x 24-inch grid. Microsoft Teams™ is expected that are those of their respective owners. Sennheiser is required to adapt the microphone to the TeamConnect Ceiling 2 instruction manual for proper mounting...
Release Notes - TeamConnect Ceiling 2 Firmware 1.8.4
Page 1
... via SSC and the reset button • Dante input channel was renamed to "FarEndRef" (Requires TCC2 Dante firmware update to the new release. TeamConnect Ceiling 2 Release Notes TeamConnect Ceiling 2 Ceiling microphone array Firmware Update • The TeamConnect Ceiling 2 firmware update requires the Sennheiser Control Cockpit software: www.sennheiser.com/control-cockpit-software Firmware version 1.8.4 - Features • Operating system has been updated to the latest patch level • Support for a few minutes while the device is automatically reinitialized...
... via SSC and the reset button • Dante input channel was renamed to "FarEndRef" (Requires TCC2 Dante firmware update to the new release. TeamConnect Ceiling 2 Release Notes TeamConnect Ceiling 2 Ceiling microphone array Firmware Update • The TeamConnect Ceiling 2 firmware update requires the Sennheiser Control Cockpit software: www.sennheiser.com/control-cockpit-software Firmware version 1.8.4 - Features • Operating system has been updated to the latest patch level • Support for a few minutes while the device is automatically reinitialized...
Release Notes - TeamConnect Ceiling 2 Firmware 1.8.4
Page 2
...-05-20 • Compatible with Control Cockpit ≥ 4.0.0 • Support for handling manual network gateway settings Firmware version 1.4.2 - Release Date 2019-08-30 • Configuration of far end activity via the LEDs • TCC2 Operating system updated to latest patch level • Bug fix for DHCP client ID after firmware 1.7.2 has been uploaded via audio level) • New SSC setting "Automatic AEC Reference...
...-05-20 • Compatible with Control Cockpit ≥ 4.0.0 • Support for handling manual network gateway settings Firmware version 1.4.2 - Release Date 2019-08-30 • Configuration of far end activity via the LEDs • TCC2 Operating system updated to latest patch level • Bug fix for DHCP client ID after firmware 1.7.2 has been uploaded via audio level) • New SSC setting "Automatic AEC Reference...
Product Specification Sennheiser Control Cockpit
Page 1
... firmware updates • Built-in interactive manual with search function for detailed information • Global password protection and SSL encryption ensure a secure access and data transfer • Notification profiles with notification and subscription preferences • Out of range detection for SpeechLine Digital Wireless transmitters with email and SMS notification • Advanced beam configuration for TeamConnect Ceiling 2 with a 3D real-time visualization Sennheiser Control...
... firmware updates • Built-in interactive manual with search function for detailed information • Global password protection and SSL encryption ensure a secure access and data transfer • Notification profiles with notification and subscription preferences • Out of range detection for SpeechLine Digital Wireless transmitters with email and SMS notification • Advanced beam configuration for TeamConnect Ceiling 2 with a 3D real-time visualization Sennheiser Control...
Product Specification Sennheiser Control Cockpit
Page 2
SOFTWARE SPECIFICATION 2/5 Sennheiser Control Cockpit Control Software WORKFLOWS KEY WORKFLOW AREAS SETUP MONITORING WORKFLOWS Language selection via browser setting or language selector Password settings for secured access to Sennheiser Control Cockpit Adding device automatically (discovery via mDNS) Adding device manually via IP address, IP range or listed in CSV file Configure location settings such as location name RF: Multi-Room-Mode Setup RF: Adjust RF power settings RF: Walk test mode to...
SOFTWARE SPECIFICATION 2/5 Sennheiser Control Cockpit Control Software WORKFLOWS KEY WORKFLOW AREAS SETUP MONITORING WORKFLOWS Language selection via browser setting or language selector Password settings for secured access to Sennheiser Control Cockpit Adding device automatically (discovery via mDNS) Adding device manually via IP address, IP range or listed in CSV file Configure location settings such as location name RF: Multi-Room-Mode Setup RF: Adjust RF power settings RF: Walk test mode to...
Product Specification Sennheiser Control Cockpit
Page 3
... mode Easy to follow workflow assistance to quickly solve problems Integrated and searchable online manual Contextual advice and assistive information to device factory defaults Remote device restart trigger Remote trigger of pairing process Remote pairing between receivers and transmitters placed in case of available updates Seamless update procedures of software and (multiselected) device firmware Batch update of multiple devices at once Service relevant information such as log of the available frequency spectrum with time...
... mode Easy to follow workflow assistance to quickly solve problems Integrated and searchable online manual Contextual advice and assistive information to device factory defaults Remote device restart trigger Remote trigger of pairing process Remote pairing between receivers and transmitters placed in case of available updates Seamless update procedures of software and (multiselected) device firmware Batch update of multiple devices at once Service relevant information such as log of the available frequency spectrum with time...
Product Specification Sennheiser Control Cockpit
Page 4
... / Firmware Update 45 UDP | TCP SSC Sound Control Protocol SPECIFICATIONS Language support • English • German • French • Spanish • Chinese Product TeamConnect Ceiling 2 TeamConnect Ceiling 2 TeamConnect Ceiling 2, Digital 6000 Digital 6000 evolution wireless G4 evolution wireless G4 SpeechLine Digital Wireless SpeechLine Digital Wireless SpeechLine Digital Wireless Rack Receiver Network-enabled chargers CHG 2N/4N/70N Evolution Wireless Digital EW-DX EM 2 Compatible Sennheiser products • Evolution Wireless Digital • SpeechLine Digital Wireless •...
... / Firmware Update 45 UDP | TCP SSC Sound Control Protocol SPECIFICATIONS Language support • English • German • French • Spanish • Chinese Product TeamConnect Ceiling 2 TeamConnect Ceiling 2 TeamConnect Ceiling 2, Digital 6000 Digital 6000 evolution wireless G4 evolution wireless G4 SpeechLine Digital Wireless SpeechLine Digital Wireless SpeechLine Digital Wireless Rack Receiver Network-enabled chargers CHG 2N/4N/70N Evolution Wireless Digital EW-DX EM 2 Compatible Sennheiser products • Evolution Wireless Digital • SpeechLine Digital Wireless •...
Product Specification Sennheiser Control Cockpit
Page 5
... Sync, RF Power, Out of Range Detection with Windows 7 or higher. Sennheiser electronic GmbH & Co. The user interface shall provide a dashboard view that displays the number of available microphone links together with link status information, the number of the devices in the network, the number of devices per room as well as device type and name, location, link activity, last online status, battery health, battery status, charging cycles, firmware version, product family, serial number...
... Sync, RF Power, Out of Range Detection with Windows 7 or higher. Sennheiser electronic GmbH & Co. The user interface shall provide a dashboard view that displays the number of available microphone links together with link status information, the number of the devices in the network, the number of devices per room as well as device type and name, location, link activity, last online status, battery health, battery status, charging cycles, firmware version, product family, serial number...
Mounting and operating instructions TeamConnect Ceiling 2 PDF
Page 9
The minimum distance from the speaker to the TeamConnect Ceiling 2 is 2.50 m. TeamConnect Ceiling 2 | 25 If installation variants 1 or 2 would result in the section „Installing the TeamConnect Ceiling 2" on page 21 Detailed installation instructions can be found in a distance greater than the recommended maximum due to the room height, we recommend installation variant 3. mmiinn.. 44--55mm 22.,55mm mmaaxx. 55 mm mmiinn...
The minimum distance from the speaker to the TeamConnect Ceiling 2 is 2.50 m. TeamConnect Ceiling 2 | 25 If installation variants 1 or 2 would result in the section „Installing the TeamConnect Ceiling 2" on page 21 Detailed installation instructions can be found in a distance greater than the recommended maximum due to the room height, we recommend installation variant 3. mmiinn.. 44--55mm 22.,55mm mmaaxx. 55 mm mmiinn...
Mounting and operating instructions TeamConnect Ceiling 2 PDF
Page 17
... the TeamConnect Ceiling 2 Variant 2: configuring the TeamConnect Ceiling 2 as a standalone solution using a computer Proceed as a PDF file on the TeamConnect Ceiling 2. A media control system allows you can use a custom user interface with the Sennheiser Control Cockpit, the TeamConnect Ceiling 2 can also be operated using a network cable (Cat5e or higher). www.sennheiser.com/tcc2 TeamConnect Ceiling 2 | 33 f Connect the network switch to use a PoE injector. Alternatively, you to the Ethernet PoE/Ctrl socket on the product web...
... the TeamConnect Ceiling 2 Variant 2: configuring the TeamConnect Ceiling 2 as a standalone solution using a computer Proceed as a PDF file on the TeamConnect Ceiling 2. A media control system allows you can use a custom user interface with the Sennheiser Control Cockpit, the TeamConnect Ceiling 2 can also be operated using a network cable (Cat5e or higher). www.sennheiser.com/tcc2 TeamConnect Ceiling 2 | 33 f Connect the network switch to use a PoE injector. Alternatively, you to the Ethernet PoE/Ctrl socket on the product web...