...odours from its internal fan. Please read before operating your new Air Purifier The air purifier draws in cigarette smoke). The Active Carbon Filter gradually absorbs odour elements as well.) Some odour ingredients absorbed by moving its air outlet. Depending on the usage environment, especially when ...the product is suggested to open the window a bit when you are absorbed by True HEPA Filter as they repeatedly pass through , a new True HEPA Filter can remove 99.97% of dust particles, of the unit, then discharges the air from construction materials and ...
...odours from its internal fan. Please read before operating your new Air Purifier The air purifier draws in cigarette smoke). The Active Carbon Filter gradually absorbs odour elements as well.) Some odour ingredients absorbed by moving its air outlet. Depending on the usage environment, especially when ...the product is suggested to open the window a bit when you are absorbed by True HEPA Filter as they repeatedly pass through , a new True HEPA Filter can remove 99.97% of dust particles, of the unit, then discharges the air from construction materials and ...
Operation Manual
Page 3
... CAUTIONS CONCERNING OPERATION ... E-19 • MAIN UNIT E-20 • PRE-FILTER E-20 • SENSORS E-20 • FILTER REPLACEMENT GUIDELINES E-21 TROUBLE SHOOTING E-22 SPECIFICATIONS E-23 Declaration of Conformity SHARP AIR PURIFIER FP-R65CX This ISM device complies with a water mist that helps to further reduce odours ... in the air detected by the odour and dust sensors. Washable to maintain optimum deodorization performance. • Filters 1) Washable Active Carbon Filter Absorbs odour elements. E-13 • MAIN UNIT INDICATOR E-14 CARE AND MAINTENANCE E-16 • HOW TO...
... CAUTIONS CONCERNING OPERATION ... E-19 • MAIN UNIT E-20 • PRE-FILTER E-20 • SENSORS E-20 • FILTER REPLACEMENT GUIDELINES E-21 TROUBLE SHOOTING E-22 SPECIFICATIONS E-23 Declaration of Conformity SHARP AIR PURIFIER FP-R65CX This ISM device complies with a water mist that helps to further reduce odours ... in the air detected by the odour and dust sensors. Washable to maintain optimum deodorization performance. • Filters 1) Washable Active Carbon Filter Absorbs odour elements. E-13 • MAIN UNIT INDICATOR E-14 CARE AND MAINTENANCE E-16 • HOW TO...
Operation Manual
Page 5
... 1 years (magnetron component-4 additional years) 1 year (picture tube component-1 additional year) 1 year 1 year 1 year (except filters) FRANÇAIS To obtain the name and address of the nearest Authorized Sharp Service Centre or Dealer, please contact: SHARP ELECTRONICS OF CANADA LTD. 335 Britannia Road, East Mississauga, Ontario L4Z 1W9 For more information on...
... 1 years (magnetron component-4 additional years) 1 year (picture tube component-1 additional year) 1 year 1 year 1 year (except filters) FRANÇAIS To obtain the name and address of the nearest Authorized Sharp Service Centre or Dealer, please contact: SHARP ELECTRONICS OF CANADA LTD. 335 Britannia Road, East Mississauga, Ontario L4Z 1W9 For more information on...
Operation Manual
Page 7
... vinyl sheet, etc., to prevent the wall from becoming dirty. The unit surface may become inoperative. In this manual for extended period of the filters. The unit surface may crack or the sensor may malfunction as a result. In addition, periodically clean the wall. E-5 In addition, the sensors...exposed to direct sunlight The unit may not receive signals from the Tank. • Do not install when there is exposed to direct wind. FILTER GUIDELINES • Follow the instructions in a kitchen, etc. Holding the front panel when carrying may cause it may cause electric shock or ...
... vinyl sheet, etc., to prevent the wall from becoming dirty. The unit surface may become inoperative. In this manual for extended period of the filters. The unit surface may crack or the sensor may malfunction as a result. In addition, periodically clean the wall. E-5 In addition, the sensors...exposed to direct sunlight The unit may not receive signals from the Tank. • Do not install when there is exposed to direct wind. FILTER GUIDELINES • Follow the instructions in a kitchen, etc. Holding the front panel when carrying may cause it may cause electric shock or ...
Operation Manual
Page 9
... Operation Indicator Light CLEAN-SIGN Light MIST Operation Indicator Light Odour Sensor Temperature / Humidity Sensor Tank Tank Cap Filter Frame True HEPA Filter Washable Active Carbon Filter Pre - Filter MIST Unit MIST Filter Set • MIST Filter • MIST Filter Frame • Antibacterial Sheet MIST Tray Cap Float MIST Tray MIST Tray Top Power ON/OFF Button...
... Operation Indicator Light CLEAN-SIGN Light MIST Operation Indicator Light Odour Sensor Temperature / Humidity Sensor Tank Tank Cap Filter Frame True HEPA Filter Washable Active Carbon Filter Pre - Filter MIST Unit MIST Filter Set • MIST Filter • MIST Filter Frame • Antibacterial Sheet MIST Tray Cap Float MIST Tray MIST Tray Top Power ON/OFF Button...
Operation Manual
Page 10
..., then pull the Front Panel. Active Carbon Filter True HEPA Filter E-8 PREPARATION Be sure to remove the filters from the wall outlet. Preparing Active Carbon Filter. Front Panel 2 Pull out the Filter Frame and remove the Pre-Filter. Filter Frame Pre-Filter 3 Remove the True HEPA Filter. Pre-Filter True HEPA Filter Active Carbon Filter Filter Frame (At open) 4 Remove the ActiveCarbonFilter(black...
..., then pull the Front Panel. Active Carbon Filter True HEPA Filter E-8 PREPARATION Be sure to remove the filters from the wall outlet. Preparing Active Carbon Filter. Front Panel 2 Pull out the Filter Frame and remove the Pre-Filter. Filter Frame Pre-Filter 3 Remove the True HEPA Filter. Pre-Filter True HEPA Filter Active Carbon Filter Filter Frame (At open) 4 Remove the ActiveCarbonFilter(black...
Operation Manual
Page 11
... Date Label. Please make sure that the True HEPA Filter is placed in the corners of the Active Carbon Filter. Date Label E-9 Use the date as a guide for the Filter Replacement schedule. ENGLISH FRANÇAIS 2 Install the filters 1 Place the True HEPA Filter within the Filter Frame. Side View Front Panel 5 Fill in the usage...
... Date Label. Please make sure that the True HEPA Filter is placed in the corners of the Active Carbon Filter. Date Label E-9 Use the date as a guide for the Filter Replacement schedule. ENGLISH FRANÇAIS 2 Install the filters 1 Place the True HEPA Filter within the Filter Frame. Side View Front Panel 5 Fill in the usage...
Operation Manual
Page 16
... Mode and the air in the room is selected using the 'Lights ON/OFF Button' on the Remote Control. OPERATION MAIN UNIT INDICATOR 5 Active Carbon Filter Indicator Light 6 MIST Unit Indicator Light 3 MIST Operation Indicator Light 2 CLEAN-SIGN Light 4 SENTINEL Operation Indicator Light 1 Plasmacluster Indicator Light 1 PLASMACLUSTER INDICATOR LIGHT Plasmacluster ion...
... Mode and the air in the room is selected using the 'Lights ON/OFF Button' on the Remote Control. OPERATION MAIN UNIT INDICATOR 5 Active Carbon Filter Indicator Light 6 MIST Unit Indicator Light 3 MIST Operation Indicator Light 2 CLEAN-SIGN Light 4 SENTINEL Operation Indicator Light 1 Plasmacluster Indicator Light 1 PLASMACLUSTER INDICATOR LIGHT Plasmacluster ion...
Operation Manual
Page 17
...about 1 month, when using the unit 24 hours a day, every day.) (See Page E-19) 6 MIST FILTER INDICATOR LIGHT Clean the MIST Filter when the MIST Filter Indicator Light activates. (The indicator light will come out automatically. FRANÇAIS Molds and mildews: refer to ".... Viruses: refer to Taisaku (Indoor Pollution: Causes and Measures)" Plasmacluster Indicator Light 5 ACTIVE CARBON FILTER INDICATOR LIGHT Clean the Active Carbon Filter when the Active Carbon Filter Indicator Light activates. (The indicator light will activate in to "The Influence of Environment on humidity and...
...about 1 month, when using the unit 24 hours a day, every day.) (See Page E-19) 6 MIST FILTER INDICATOR LIGHT Clean the MIST Filter when the MIST Filter Indicator Light activates. (The indicator light will come out automatically. FRANÇAIS Molds and mildews: refer to ".... Viruses: refer to Taisaku (Indoor Pollution: Causes and Measures)" Plasmacluster Indicator Light 5 ACTIVE CARBON FILTER INDICATOR LIGHT Clean the Active Carbon Filter when the Active Carbon Filter Indicator Light activates. (The indicator light will activate in to "The Influence of Environment on humidity and...
Operation Manual
Page 18
... PANEL Dust Sensor Odour Sensor Temperature / Humidity Sensor Care Cycle : 2 months How to Care : See Page E-20 Active Carbon Filter Care Cycle : 2 months The Active Carbon Filter Indicator Light lights up. CARE AND MAINTENANCE HOW TO REMOVE THE UNIT To maintain optimum performance of this air purifier, please clean... the unit including the sensor and filters periodically. 1 When cleaning the unit, be sure to Care : See Page E-19 Do not wash the True HEPA Filter. Filter Care Cycle : 2 months How to Care : See Page E-20 Front Panel ...
... PANEL Dust Sensor Odour Sensor Temperature / Humidity Sensor Care Cycle : 2 months How to Care : See Page E-20 Active Carbon Filter Care Cycle : 2 months The Active Carbon Filter Indicator Light lights up. CARE AND MAINTENANCE HOW TO REMOVE THE UNIT To maintain optimum performance of this air purifier, please clean... the unit including the sensor and filters periodically. 1 When cleaning the unit, be sure to Care : See Page E-19 Do not wash the True HEPA Filter. Filter Care Cycle : 2 months How to Care : See Page E-20 Front Panel ...
Operation Manual
Page 19
...lights up . MIST Tray Cap Be careful of water. How to Care : See Page E-18 Open the MIST Tray. Mist Filter MIST Filter Frame Mist Filter Set Care Cycle : 2 weeks The MIST Filter Indicator Light lights up . Mist Tray Top Mist Tray E-17 Remove all at once may fall . Remove the MIST Tray Cap...by tilting the MIST Unit slowly, as excessive force applied all the water drops that may fall . • Do not take the MIST Filter out of a MIST Filter frame, to avoid spilling of the water drops that are on the tank cap before you pull out the tank. Carefully remove the top...
...lights up . MIST Tray Cap Be careful of water. How to Care : See Page E-18 Open the MIST Tray. Mist Filter MIST Filter Frame Mist Filter Set Care Cycle : 2 weeks The MIST Filter Indicator Light lights up . Mist Tray Top Mist Tray E-17 Remove all at once may fall . Remove the MIST Tray Cap...by tilting the MIST Unit slowly, as excessive force applied all the water drops that may fall . • Do not take the MIST Filter out of a MIST Filter frame, to avoid spilling of the water drops that are on the tank cap before you pull out the tank. Carefully remove the top...
Operation Manual
Page 20
... the mist tray set by following the procedures shown in some drugstores, or 100% bottled lemon juice are not sure). MIST Filter Antibacterial Sheet MIST Filter Frame 3 Rinse the MIST Filter set to cleaning. Failing to close the cap completely may cause citric acid odour or changes in water spills. MIST...the cap. Choose one to presoak longer than citric acid. MIST UNIT 1 Preparing the descaling solution. MIST Tray MIST Tray Cap 6 Attach the MIST Filter set with a cotton swab or tooth brush. 5 Put the MIST tray cap back on to close it. Tank E-18 Use only bottled 100% ...
... the mist tray set by following the procedures shown in some drugstores, or 100% bottled lemon juice are not sure). MIST Filter Antibacterial Sheet MIST Filter Frame 3 Rinse the MIST Filter set to cleaning. Failing to close the cap completely may cause citric acid odour or changes in water spills. MIST...the cap. Choose one to presoak longer than citric acid. MIST UNIT 1 Preparing the descaling solution. MIST Tray MIST Tray Cap 6 Attach the MIST Filter set with a cotton swab or tooth brush. 5 Put the MIST tray cap back on to close it. Tank E-18 Use only bottled 100% ...
Operation Manual
Page 21
... large container with water after rinsing. It may soil your fingers. • Let the filter dry thoroughly. If used while the filter is good and dry it on 24 hours a day then the Filter Indicator Light will then go out automatically. Wash it in a well ventilated area. CAUTION If...be removed. 7 Connect the power cord to be cleaned. To decrease drying time, wrap the filter in a container, be saturated with warm water, add a mild kitchen detergent and stir. Clean the filter as often as indicated on Page E-8,9 3 Rinse thoroughly with your floor. • Make ...
... large container with water after rinsing. It may soil your fingers. • Let the filter dry thoroughly. If used while the filter is good and dry it on 24 hours a day then the Filter Indicator Light will then go out automatically. Wash it in a well ventilated area. CAUTION If...be removed. 7 Connect the power cord to be cleaned. To decrease drying time, wrap the filter in a container, be saturated with warm water, add a mild kitchen detergent and stir. Clean the filter as often as indicated on Page E-8,9 3 Rinse thoroughly with your floor. • Make ...
Operation Manual
Page 22
...Dust Sensor E-20 If stains are allowed to remain, they may become hard to remove the dust. Pre-Filter SENSORS (DUST SENSOR, ODOUR SENSOR, TEMPERATURE/HUMIDITY SENSOR) Remove dust from water PRE-FILTER As shown in a figure, clean the top surface of the sensors using a vacuum cleaner. If it... very dirty, wash it with water and then allow it lightly with mild kitchen detergent and dry Pre-Filter well in the sensor cover.) (Detach the sensor filter and tap it to dry thoroughly. Do not use detergents Detergent ingredients may damage the surface. Do not use volatile ...
...Dust Sensor E-20 If stains are allowed to remain, they may become hard to remove the dust. Pre-Filter SENSORS (DUST SENSOR, ODOUR SENSOR, TEMPERATURE/HUMIDITY SENSOR) Remove dust from water PRE-FILTER As shown in a figure, clean the top surface of the sensors using a vacuum cleaner. If it... very dirty, wash it with water and then allow it lightly with mild kitchen detergent and dry Pre-Filter well in the sensor cover.) (Detach the sensor filter and tap it to dry thoroughly. Do not use detergents Detergent ingredients may damage the surface. Do not use volatile ...
Operation Manual
Page 23
... dander and other concentrations of Air Purifier. Please check filters regularly and replace as needed. MIST Filter materials: • Rayon , Polyester Antibacterial sheet Materials: • Paper 40% For replacement filters contact Sharp for information. (CANADA) (905) 568-7140 or website at www.sharp.ca E-21 FILTER REPLACEMENT GUIDELINES ENGLISH The replacement period differs depending on the...
... dander and other concentrations of Air Purifier. Please check filters regularly and replace as needed. MIST Filter materials: • Rayon , Polyester Antibacterial sheet Materials: • Paper 40% For replacement filters contact Sharp for information. (CANADA) (905) 568-7140 or website at www.sharp.ca E-21 FILTER REPLACEMENT GUIDELINES ENGLISH The replacement period differs depending on the...
Operation Manual
Page 24
... , since the problem may produce an odour. Check to E-18,21) E-22 A clicking or ticking sound is generating ions. Replace the filters. • Plasmacluster Air Purifiers emit small traces of blue and green) repeats the light/dark colour cycles. SENTINEL Operation mode is turned on ...The CLEAN-SIGN Light lights green even when the air is impure. • The air could be a unit malfunction. Clean the Mist Tray. Replace the filter when it is working. REMEDY (not a malfunction) • Have the batteries been depleted? • Are the batteries inserted correctly? • Is ...
... , since the problem may produce an odour. Check to E-18,21) E-22 A clicking or ticking sound is generating ions. Replace the filters. • Plasmacluster Air Purifiers emit small traces of blue and green) repeats the light/dark colour cycles. SENTINEL Operation mode is turned on ...The CLEAN-SIGN Light lights green even when the air is impure. • The air could be a unit malfunction. Clean the Mist Tray. Replace the filter when it is working. REMEDY (not a malfunction) • Have the batteries been depleted? • Are the batteries inserted correctly? • Is ...