Service Manual
Page 9
... Signal Auto Sync. Position Standby Mode Language Reset Setup Option Audio Only Digital Noise Reduction Input Select HDMI Setup Output Select LC-32D41U/LC-32M41U/LC-40C32U 2 - 3 Audio Setup Digital Setup Basic adjustment settings Menu items for TV/INPUT 1/INPUT 2 Menu items for HDMI/DVI Picture OPC Backlight Contrast Brightness Color Tint Sharpness Advanced Color Temp.
... Signal Auto Sync. Position Standby Mode Language Reset Setup Option Audio Only Digital Noise Reduction Input Select HDMI Setup Output Select LC-32D41U/LC-32M41U/LC-40C32U 2 - 3 Audio Setup Digital Setup Basic adjustment settings Menu items for TV/INPUT 1/INPUT 2 Menu items for HDMI/DVI Picture OPC Backlight Contrast Brightness Color Tint Sharpness Advanced Color Temp.
Service Manual
Page 21
... Set the point 4 to the specified gradation. dard value. MG6G**** 8) Write the adjustment values with the R/C. AV MODE: [DYNAMIC] Backlight: +16 Aging Time: Min. 60 minutes 2) Connect a white balance adjustment jig and the set. 2 Execution of white balance 1. Set ...stan- MSET0004 dard value. 7) Set the point 1 to DVI-I (analog) signal: XGA (1024 x 768) 60Hz SYNC: HV separate LC-32D41U/LC-32M41U/LC-40C32U Adjustment procedure Feed the XGA (100%) white 1/2 window to the specified gradation. DVI-I (analog) signal adjustment Adjustment item Adjustment conditions 1...
... Set the point 4 to the specified gradation. dard value. MG6G**** 8) Write the adjustment values with the R/C. AV MODE: [DYNAMIC] Backlight: +16 Aging Time: Min. 60 minutes 2) Connect a white balance adjustment jig and the set. 2 Execution of white balance 1. Set ...stan- MSET0004 dard value. 7) Set the point 1 to DVI-I (analog) signal: XGA (1024 x 768) 60Hz SYNC: HV separate LC-32D41U/LC-32M41U/LC-40C32U Adjustment procedure Feed the XGA (100%) white 1/2 window to the specified gradation. DVI-I (analog) signal adjustment Adjustment item Adjustment conditions 1...
Service Manual
Page 27
2.8. Menu list in process A mode LC-32D41U/LC-32M41U/LC-40C32U Page 1 Line Item MAIN Version BOOT Version Monitor Version EQ DATA CHECKSUM TEMPERATURE LAMP ERROR NORMAL STANDBY CAUSE ERROR STANDBY CAUSE Main microcomputer ... HOTELMODE Activate/deactivate the hotel mode Center Acutime Main microcomputer operating time RESET Reset main microcomputer operating time Lamp error rest BacklightAcutime Backlight lighting time RESET Reset backlight lighting time LAMP ERROR RESET VIC XPOS x-coordinate for reading image data VIC YPOS y-coordinate for reading image data VIC COLOR ...
2.8. Menu list in process A mode LC-32D41U/LC-32M41U/LC-40C32U Page 1 Line Item MAIN Version BOOT Version Monitor Version EQ DATA CHECKSUM TEMPERATURE LAMP ERROR NORMAL STANDBY CAUSE ERROR STANDBY CAUSE Main microcomputer ... HOTELMODE Activate/deactivate the hotel mode Center Acutime Main microcomputer operating time RESET Reset main microcomputer operating time Lamp error rest BacklightAcutime Backlight lighting time RESET Reset backlight lighting time LAMP ERROR RESET VIC XPOS x-coordinate for reading image data VIC YPOS y-coordinate for reading image data VIC COLOR ...
Service Manual
Page 42
... for the monitor model No. L_FL_ERR (pin 73): Abnormal L. Note that is performed at 1 second intervals (detected only when the backlight is activated by polling. If error is detected during operation (interruption) If the panel temperature is 60°C or more for 15 ... row, error standby is interrupted. ψ Main CPU operation failure or monitor microprocessor's reception failure Refer to "Power failure details". LC-32D41U/LC-32M41U/LC-40C32U 6 - 11 LED flashing timing chart for error notification 250ms 1sec 1) Red power LED Error type Lamp failure Flashes once: Fast ...
... for the monitor model No. L_FL_ERR (pin 73): Abnormal L. Note that is performed at 1 second intervals (detected only when the backlight is activated by polling. If error is detected during operation (interruption) If the panel temperature is 60°C or more for 15 ... row, error standby is interrupted. ψ Main CPU operation failure or monitor microprocessor's reception failure Refer to "Power failure details". LC-32D41U/LC-32M41U/LC-40C32U 6 - 11 LED flashing timing chart for error notification 250ms 1sec 1) Red power LED Error type Lamp failure Flashes once: Fast ...