Datasheet
Page 1
... triggered by power failure • Power supply sold separately (model: TI-M6024) • Fanless design for industrial environments within a -40° - 75° C (-40° - 167° F) wide-temperature range. TI-E80 8-Port Industrial Fast Ethernet DIN-Rail Switch TI-E80 (v1.0R) • 8 x Fast Ethernet ports • 1.6Gbps switching capacity • Forwarding rate: 1.19Mpps (64-byte packet size) • Hardened IP30 rated metal switch • Includes DIN-Rail mount and wall mount brackets •...
... triggered by power failure • Power supply sold separately (model: TI-M6024) • Fanless design for industrial environments within a -40° - 75° C (-40° - 167° F) wide-temperature range. TI-E80 8-Port Industrial Fast Ethernet DIN-Rail Switch TI-E80 (v1.0R) • 8 x Fast Ethernet ports • 1.6Gbps switching capacity • Forwarding rate: 1.19Mpps (64-byte packet size) • Hardened IP30 rated metal switch • Includes DIN-Rail mount and wall mount brackets •...
Datasheet
Page 2
Industrial Hardened Design Equipped with a rugged IP30 rated housing, and designed to provide redundant power with overload current protection. NETWORKING SOLUTION Redundant Power The industrial Ethernet switches feature dual power inputs to withstand a high degree of vibration and shock, while operating within a wide temperature range of -40° - 75° C (-40° - 167° F). TI-E80 Easy Installation No configuration needed, simply connect network devices to the industrial Ethernet switch.
Industrial Hardened Design Equipped with a rugged IP30 rated housing, and designed to provide redundant power with overload current protection. NETWORKING SOLUTION Redundant Power The industrial Ethernet switches feature dual power inputs to withstand a high degree of vibration and shock, while operating within a wide temperature range of -40° - 75° C (-40° - 167° F). TI-E80 Easy Installation No configuration needed, simply connect network devices to the industrial Ethernet switch.
Datasheet
Page 3
... Interface • 8 x Fast Ethernet ports • 6-pin removable terminal block • LED indicators • DIN-Rail mount • Wall mount • Grounding point Data Transfer Rate • Ethernet: 10Mbps (half duplex), 20Mbps (full duplex) • Fast Ethernet: 100Mbps (half duplex), 200Mbps (full duplex) Performance • Data RAM Buffer: 56KB • Switching Fabric: 1.6Gbps • MAC Address Table: 1K entries • Forwarding rate: 1.19Mpps (64-byte packet size) Special Features • Hardened components rated for extreme temperatures • Redundant power...
... Interface • 8 x Fast Ethernet ports • 6-pin removable terminal block • LED indicators • DIN-Rail mount • Wall mount • Grounding point Data Transfer Rate • Ethernet: 10Mbps (half duplex), 20Mbps (full duplex) • Fast Ethernet: 100Mbps (half duplex), 200Mbps (full duplex) Performance • Data RAM Buffer: 56KB • Switching Fabric: 1.6Gbps • MAC Address Table: 1K entries • Forwarding rate: 1.19Mpps (64-byte packet size) Special Features • Hardened components rated for extreme temperatures • Redundant power...
Quick Installation Guide
Page 2
Hardware Installation Before You Start 2. Quick Reference 3. Table of Contents 1 English 1.
Hardware Installation Before You Start 2. Quick Reference 3. Table of Contents 1 English 1.
Quick Installation Guide
Page 4
Hardware Installation The switch can be placed on a desktop, wall, or mounted to lock it is secure when you hear the click. Mounting the unit Releasing the unit 4. Rotate the fiber converter downward towards the rail to a DIN-Rail. DIN-Rail Mounting Instructions 1. To remove the unit, pull down to the switch. 2. Attach the DIN-rail mount bracket to clear the bottom of the rail. 13. 3. You will know it into place. Position the unit in front of the DIN-Rail and hook the mount bracket over the top of the DIN-Rail and rotate up, away from the rail. 2
Hardware Installation The switch can be placed on a desktop, wall, or mounted to lock it is secure when you hear the click. Mounting the unit Releasing the unit 4. Rotate the fiber converter downward towards the rail to a DIN-Rail. DIN-Rail Mounting Instructions 1. To remove the unit, pull down to the switch. 2. Attach the DIN-rail mount bracket to clear the bottom of the rail. 13. 3. You will know it into place. Position the unit in front of the DIN-Rail and hook the mount bracket over the top of the DIN-Rail and rotate up, away from the rail. 2
Quick Installation Guide
Page 5
... current in each wire size. If the current surpasses the maximum ratings, the wiring could overheat, causing serious damage to your power source to switch. 2. co 0 0 0 0- Check the voltage of your equipment. 3 Attach the wall mount plates to make sure that you are using the correct part. co oo0 Safety Note • Turn off the power before connecting any module or wire.
... current in each wire size. If the current surpasses the maximum ratings, the wiring could overheat, causing serious damage to your power source to switch. 2. co 0 0 0 0- Check the voltage of your equipment. 3 Attach the wall mount plates to make sure that you are using the correct part. co oo0 Safety Note • Turn off the power before connecting any module or wire.
Quick Installation Guide
Page 6
Attach the terminal block to the unit, connect the neutral wire to the ground, and supply power to confirm the connections are established. I - il l oL OK O GND W1. 02- Check the LEDs to the power adapter. Note: Polarities must match. 2. Connect a network source and devices to the included terminal block (as shown below) and secure with the screws. TI-E50 TI-E80 .0. Apo'vino Power 1. DL OK +V O GND PW1 rr PW2 1424V I 0 0 3. Connect the power supply (sold separately) to the switch. Your installation is completed. 4
Attach the terminal block to the unit, connect the neutral wire to the ground, and supply power to confirm the connections are established. I - il l oL OK O GND W1. 02- Check the LEDs to the power adapter. Note: Polarities must match. 2. Connect a network source and devices to the included terminal block (as shown below) and secure with the screws. TI-E50 TI-E80 .0. Apo'vino Power 1. DL OK +V O GND PW1 rr PW2 1424V I 0 0 3. Connect the power supply (sold separately) to the switch. Your installation is completed. 4
Quick Installation Guide
Page 7
TI-E50 / TI-E80 LED Indicators LED PW1 PW2 RLY (TI-E80) Link Status Solid Green Solid Green Solid Amber Solid Green Flashing Green Off Description Power Connected Power Connected Connected only PW1 or PW2 Connected Data Transmitting / Receiving No Connection 5 s a a
TI-E50 / TI-E80 LED Indicators LED PW1 PW2 RLY (TI-E80) Link Status Solid Green Solid Green Solid Amber Solid Green Flashing Green Off Description Power Connected Power Connected Connected only PW1 or PW2 Connected Data Transmitting / Receiving No Connection 5 s a a
Quick Installation Guide
Page 8
...: Sonny Su Title: Director of Conformity TRErlDnEf Manufacturer's Name and Address TRENDnet, Inc. 20675 Manhattan Place Torrance, CA 90501 USA Zwolsestraat 156 2587 WB The Hague The Netherlands Product Information: Model Number: Product Name: Trade Name: TI-E50/TI-E80 5-Port Industrial Fast Ethernet DIN-Rail Switch 8-Port Industrial Fast Ethernet DIN-Rail Switch TRENDnet TRENDnet hereby declare that the product is herewith confirmed to comply with...
...: Sonny Su Title: Director of Conformity TRErlDnEf Manufacturer's Name and Address TRENDnet, Inc. 20675 Manhattan Place Torrance, CA 90501 USA Zwolsestraat 156 2587 WB The Hague The Netherlands Product Information: Model Number: Product Name: Trade Name: TI-E50/TI-E80 5-Port Industrial Fast Ethernet DIN-Rail Switch 8-Port Industrial Fast Ethernet DIN-Rail Switch TRENDnet TRENDnet hereby declare that the product is herewith confirmed to comply with...
Quick Installation Guide
Page 9
... disposed of the FCC Rules. TRErlDnET® Certifications This device complies with Part 15 of with your product online. Technical Support If you have any interference received. Toll free US/Canada: 1-855-373-4741 Regional phone numbers available at wwwtrendnet.com/register TI-E50 /TI-E80 (V1) / 06.19.2019 Product Warranty Registration Please take a moment to the...
... disposed of the FCC Rules. TRErlDnET® Certifications This device complies with Part 15 of with your product online. Technical Support If you have any interference received. Toll free US/Canada: 1-855-373-4741 Regional phone numbers available at wwwtrendnet.com/register TI-E50 /TI-E80 (V1) / 06.19.2019 Product Warranty Registration Please take a moment to the...