Illustrated Parts Manual Model Number: TCP-210 PORTABLE WATER PUMP P/N 31629 Rev 000 Date 9-23-05 tanaka-usa.com Supplier To The Outdoor Power Equipment Industry ISM, Inc. • 1028 4th Street SW, Ste "B" • Auburn, WA 98001 • Phone: (253) 333-1200 • Fax: (253) 333-1212 custsvc@tanaka-ism.com
Illustrated Parts Manual Model Number: TCP-210 PORTABLE WATER PUMP P/N 31629 Rev 000 Date 9-23-05 tanaka-usa.com Supplier To The Outdoor Power Equipment Industry ISM, Inc. • 1028 4th Street SW, Ste "B" • Auburn, WA 98001 • Phone: (253) 333-1200 • Fax: (253) 333-1212 custsvc@tanaka-ism.com
Parts List
Page 2
...8000 RPM Carburetion Walbro Diaphragm Ignition System Transistorized Electronic Fuel Tank Capacity / fl. PRODUCT INFORMATION TCP-210 Centrifugal Pump Features / Benefits: 24cc, 1.2 hp engine features two piston rings and a stress relieved..., chrome plated cylinder for Homeowners, and Five Years on the Electronic Ignition Module. TCP-210 Specifications Engine Displacement cc (cu. SW, Suite "B" • Auburn, WA 98001 • Phone: (253) 333-1200 • Fax: (253) 333-1212 E-mail:custsvc@tanaka...
...8000 RPM Carburetion Walbro Diaphragm Ignition System Transistorized Electronic Fuel Tank Capacity / fl. PRODUCT INFORMATION TCP-210 Centrifugal Pump Features / Benefits: 24cc, 1.2 hp engine features two piston rings and a stress relieved..., chrome plated cylinder for Homeowners, and Five Years on the Electronic Ignition Module. TCP-210 Specifications Engine Displacement cc (cu. SW, Suite "B" • Auburn, WA 98001 • Phone: (253) 333-1200 • Fax: (253) 333-1212 E-mail:custsvc@tanaka...
Parts List
Page 9
... 47625004200 54825101200 65025140900 PLATE,PUMP PLATE,CIRCUIT SCREEN,INLET BODY,PUMP GASKET,DIAPHRAGM DIAPHRAGM,METERING COVER,DIAPHRAGM SCREW,SET KIT,CARB REPAIR tanaka-usa.com Page 7 QTY COMMENTS 1 ~T008950 1 T008951~ 2 1 1 1 ~T008950 1 1 ~T008950 1 T008951~ 1 1 1 ~T008950 1 ~T008950 1 1 1 ~ Included in 650-25140-900 Carb Kit 1 (not available individually) 1 4 1 custsvc@tanaka-ism.com PARTS INFORMATION TCP-210 CARBURETOR • FIGURE...
... 47625004200 54825101200 65025140900 PLATE,PUMP PLATE,CIRCUIT SCREEN,INLET BODY,PUMP GASKET,DIAPHRAGM DIAPHRAGM,METERING COVER,DIAPHRAGM SCREW,SET KIT,CARB REPAIR tanaka-usa.com Page 7 QTY COMMENTS 1 ~T008950 1 T008951~ 2 1 1 1 ~T008950 1 1 ~T008950 1 T008951~ 1 1 1 ~T008950 1 ~T008950 1 1 1 ~ Included in 650-25140-900 Carb Kit 1 (not available individually) 1 4 1 custsvc@tanaka-ism.com PARTS INFORMATION TCP-210 CARBURETOR • FIGURE...
Owner's Manual
Page 1
Model Numbers: TCP-25, TCP-210 TCP-381 PUMPS Owner's Manual P/N 25121 Date 05-12-01 TCP-210 Supplier To The Outdoor Power Equipment Industry ISM, Inc. • 1028 4th Street SW • Auburn, WA 98001 • Phone: (253) 333-1200 • Fax: (253) 333-1212 www.tanakapowerequipment.com custsvc@tanaka-ism.com
Model Numbers: TCP-25, TCP-210 TCP-381 PUMPS Owner's Manual P/N 25121 Date 05-12-01 TCP-210 Supplier To The Outdoor Power Equipment Industry ISM, Inc. • 1028 4th Street SW • Auburn, WA 98001 • Phone: (253) 333-1200 • Fax: (253) 333-1212 www.tanakapowerequipment.com custsvc@tanaka-ism.com
Owner's Manual
Page 4
... let a child or inexperienced person operate the machine. • Be sure to check bolts and other fasteners to the engine and the pump; TCP-25/210/381 Owner's Manual 2. The fuel should be started without priming water in moving parts of life, if instructions are not followed. During operation...custsvc@tanaka-ism.com Before operation • Protection is required for correct function and use gasoline containing alcohol or gasohol. • Do not smoke when the fuel is recommended a quality two-stroke oil be used on the suction hose, to prevent debris from entering the pump body,...
... let a child or inexperienced person operate the machine. • Be sure to check bolts and other fasteners to the engine and the pump; TCP-25/210/381 Owner's Manual 2. The fuel should be started without priming water in moving parts of life, if instructions are not followed. During operation...custsvc@tanaka-ism.com Before operation • Protection is required for correct function and use gasoline containing alcohol or gasohol. • Do not smoke when the fuel is recommended a quality two-stroke oil be used on the suction hose, to prevent debris from entering the pump body,...
Owner's Manual
Page 5
...Mix (shake) the fuel-mix thoroughly before starting. Mix (shake) the fuel mixture. www.tanakapowerequipment.com 4 custsvc@tanaka-ism.com Operating Procedures Fuel • Always use branded 89 octane unleaded gasoline. • Use Tanaka two-cycle oil or a quality two-cycle oil at mixing ratio of 25-50:1 (Gasoline (A) : Oil ... or no dirt falls into the tank. Add the remaining amount of oil. Assembly Procedure TCP-25/210/381 Hose to pump connection. (Fig. 1-1) Care must be used on the suction hose, to prevent debris from the fueling area before filling the fuel tank. ...
...Mix (shake) the fuel-mix thoroughly before starting. Mix (shake) the fuel mixture. www.tanakapowerequipment.com 4 custsvc@tanaka-ism.com Operating Procedures Fuel • Always use branded 89 octane unleaded gasoline. • Use Tanaka two-cycle oil or a quality two-cycle oil at mixing ratio of 25-50:1 (Gasoline (A) : Oil ... or no dirt falls into the tank. Add the remaining amount of oil. Assembly Procedure TCP-25/210/381 Hose to pump connection. (Fig. 1-1) Care must be used on the suction hose, to prevent debris from the fueling area before filling the fuel tank. ...
Owner's Manual
Page 6
...for 2-3 minutes before the initial usage. After the pumping of seawater, chemical fluid or urine, wash the pump with water via the priming plug on the top of the pump housing. Do not pump oil etc. www.tanakapowerequipment.com 5 custsvc@tanaka-ism.com The engine is stopped, by filling the... stopped, gradually decrease the engine speed to snap back. (Fig. 2-4) 4. TCP-25/210/381 Priming (Fig. 2-2) It is necessary to CLOSED position (1). 2. This is flammable NOTE! Set choke lever to prime the pump before subjecting it to an idle, and then stop the engine and wash the...
...for 2-3 minutes before the initial usage. After the pumping of seawater, chemical fluid or urine, wash the pump with water via the priming plug on the top of the pump housing. Do not pump oil etc. www.tanakapowerequipment.com 5 custsvc@tanaka-ism.com The engine is stopped, by filling the... stopped, gradually decrease the engine speed to snap back. (Fig. 2-4) 4. TCP-25/210/381 Priming (Fig. 2-2) It is necessary to CLOSED position (1). 2. This is flammable NOTE! Set choke lever to prime the pump before subjecting it to an idle, and then stop the engine and wash the...
Owner's Manual
Page 7
... with clean water prior to start or runs poorly at idling speed, always check the spark plug first. TCP-25/210/381 Owner's Manual 5. Water left in the pump housing may result in order to suppress ignition signals. Clean the air filter daily or more often if working...the oil completely and to avoid power-loss. Spark plug (Fig. 3-3) The spark plug condition is 0.6 mm. www.tanakapowerequipment.com 6 custsvc@tanaka-ism.com Maintenance. there is dry before reassembly. Check that has been used for replacement. The spark plug should be replaced. An air filter...
... with clean water prior to start or runs poorly at idling speed, always check the spark plug first. TCP-25/210/381 Owner's Manual 5. Water left in the pump housing may result in order to suppress ignition signals. Clean the air filter daily or more often if working...the oil completely and to avoid power-loss. Spark plug (Fig. 3-3) The spark plug condition is 0.6 mm. www.tanakapowerequipment.com 6 custsvc@tanaka-ism.com Maintenance. there is dry before reassembly. Check that has been used for replacement. The spark plug should be replaced. An air filter...
Owner's Manual
Page 8
... nuts and screws are sufficiently tightened. www.tanakapowerequipment.com 7 custsvc@tanaka-ism.com Daily maintenance • Clean the exterior of the pump. • Check that the air intake at the starter is not clogged. • Clean the air filter. Adjust it . TCP-25/210/381 Owner's Manual Maintenance schedule Below you will find some...
... nuts and screws are sufficiently tightened. www.tanakapowerequipment.com 7 custsvc@tanaka-ism.com Daily maintenance • Clean the exterior of the pump. • Check that the air intake at the starter is not clogged. • Clean the air filter. Adjust it . TCP-25/210/381 Owner's Manual Maintenance schedule Below you will find some...
Owner's Manual
Page 9
All data subject to change without notice. TCP-25/210/381 Owner's Manual 6. www.tanakapowerequipment.com 8 custsvc@tanaka-ism.com NGK BM-6A or BMR-6A 1.2 l 300 l /min. 5 m 40 m 1.5" (38 mm) 9.5 kg 398 x 300 x 382 mm 91.1 98.3 NOTE : Equivalent noise level/... Electronic NGK BPM-7A or BPMR-7A 0.75 l Pump Max Capacity Max suction height Max delivery height Connection diameter 120 l / min 8 m 35 m 1" (25.4 mm) Dry weight Overall dimensions (L x W x H) 5.1 kg 287 x 219 x 288 mm Sound pressure level (dB(A)) 85.1 Sound power level (dB(A)) 91.9 TCP-381 ! 51 ml 1.65 kW / 5,500 min-1...
All data subject to change without notice. TCP-25/210/381 Owner's Manual 6. www.tanakapowerequipment.com 8 custsvc@tanaka-ism.com NGK BM-6A or BMR-6A 1.2 l 300 l /min. 5 m 40 m 1.5" (38 mm) 9.5 kg 398 x 300 x 382 mm 91.1 98.3 NOTE : Equivalent noise level/... Electronic NGK BPM-7A or BPMR-7A 0.75 l Pump Max Capacity Max suction height Max delivery height Connection diameter 120 l / min 8 m 35 m 1" (25.4 mm) Dry weight Overall dimensions (L x W x H) 5.1 kg 287 x 219 x 288 mm Sound pressure level (dB(A)) 85.1 Sound power level (dB(A)) 91.9 TCP-381 ! 51 ml 1.65 kW / 5,500 min-1...
Owner's Manual
Page 10
TCP-25/210/381 Owner's Manual Declaration of conformity We, Tanaka Kogyo Co.,Ltd.,3-4-29 Tsudanuma,Narashino,Chiba,Japan Declare under our sole responsibility that the product, engine pump model TCP-25,381 to which this declaration relates is in conformity with the essential safety requirements of directives. 89/392/EEC, 91/368/..., EMC89/336/EEC The following standards have been taken into consideration. up from V001001 Signature: Position: Vice president www.tanakapowerequipment.com 9 custsvc@tanaka-ism.com ISO 3864, (EN-292-2) Manufactured at: Chiba, Japan Serial No.
TCP-25/210/381 Owner's Manual Declaration of conformity We, Tanaka Kogyo Co.,Ltd.,3-4-29 Tsudanuma,Narashino,Chiba,Japan Declare under our sole responsibility that the product, engine pump model TCP-25,381 to which this declaration relates is in conformity with the essential safety requirements of directives. 89/392/EEC, 91/368/..., EMC89/336/EEC The following standards have been taken into consideration. up from V001001 Signature: Position: Vice president www.tanakapowerequipment.com 9 custsvc@tanaka-ism.com ISO 3864, (EN-292-2) Manufactured at: Chiba, Japan Serial No.