Design Guide - Professional Rangetops
Page 4
... for use with Thermador Professional Rangetops. mODEL PCG304G PCG364GD PCG366G PCG486GD REQuIRED CIRCuIT BREakER 120V AC, 60Hz 15 Amp 15 Amp 15 Amp 15 Amp GaS REQuIREmEnTS anD HOOkuP ... and accessories. A manual gas shut-off the gas supply. Downdraft ventilation should , at a minimum, equal the nominal width of the unit. For high output gas cooktops or rangetops (60,000 BTu...Griddle 36" Custom Insert w/optional blower 42" or 48" Island Hood w/optional 6 Burners blower 48" 6 Burners w/Grill or Griddle 48" or 54" Pro Wall Hood 48" Custom Insert w/optional blower 54" Island Hood w/...
... for use with Thermador Professional Rangetops. mODEL PCG304G PCG364GD PCG366G PCG486GD REQuIRED CIRCuIT BREakER 120V AC, 60Hz 15 Amp 15 Amp 15 Amp 15 Amp GaS REQuIREmEnTS anD HOOkuP ... and accessories. A manual gas shut-off the gas supply. Downdraft ventilation should , at a minimum, equal the nominal width of the unit. For high output gas cooktops or rangetops (60,000 BTu...Griddle 36" Custom Insert w/optional blower 42" or 48" Island Hood w/optional 6 Burners blower 48" 6 Burners w/Grill or Griddle 48" or 54" Pro Wall Hood 48" Custom Insert w/optional blower 54" Island Hood w/...
Design Guide - Professional Rangetops
Page 11
... Base™ designed for easy clean-up - PROFESSIONAL SERIES RANGETOPS 48-INch Model: PcG486GD PROFESSIONAL PCG486GD - 48-inch Porcelain Surface SPEcIFIcATIONS Total Number of simmer options from Rear Wall Cooking Surface Gas Cooktop Burners Center Electric Griddle Total Natural Gas Connection Rating LP Convertible Total LP Gas Connection Rating Electrical Supply Required Circuit Breaker Power Cord Shipping Weight...
... Base™ designed for easy clean-up - PROFESSIONAL SERIES RANGETOPS 48-INch Model: PcG486GD PROFESSIONAL PCG486GD - 48-inch Porcelain Surface SPEcIFIcATIONS Total Number of simmer options from Rear Wall Cooking Surface Gas Cooktop Burners Center Electric Griddle Total Natural Gas Connection Rating LP Convertible Total LP Gas Connection Rating Electrical Supply Required Circuit Breaker Power Cord Shipping Weight...
Installation Instructions PART3
Page 4
..., an optional stainless steel Island Trim is correct for the owner. The Thermador Low Back backguard must be sure that the appliance is available to cover ...on LP). *All models are in the OFF position. NOTE: This Cooktop is located on page 11 before installing. INSTALLATION, ELECTRICAL CONNECTIONS, GAS CONNECTIONS, English 2 30'' Model: 4 Burners - 120 VAC, 60...60 Hz., 1 Ph., 15 Amp circuit 48" Model: 6 Burners with more than a 12" horizontal clearance between combustible materials and the back edge of the cooktop. For island installations and other installations with ...
..., an optional stainless steel Island Trim is correct for the owner. The Thermador Low Back backguard must be sure that the appliance is available to cover ...on LP). *All models are in the OFF position. NOTE: This Cooktop is located on page 11 before installing. INSTALLATION, ELECTRICAL CONNECTIONS, GAS CONNECTIONS, English 2 30'' Model: 4 Burners - 120 VAC, 60...60 Hz., 1 Ph., 15 Amp circuit 48" Model: 6 Burners with more than a 12" horizontal clearance between combustible materials and the back edge of the cooktop. For island installations and other installations with ...
Installation Instructions PART3
Page 6
...Thermador Professional Cooktops. • Refer to www.Thermador.com for tightly sealed and insulated homes. • A qualified heating and ventilating contractor should be required for use a hood width that exceeds the width of the cooktop by 6" (overlapping the cooktop by 3" on each end). • **Not all 48...options, Blowers, and Accessories. • * For high output gas cooktops (60,000 BTU or greater), the minimum of one (1) CFM of outside replacement air is recommended. Cooktop Width Cooktop Configuration Minimum Recommended Blower Capacity* Ventilation Options 30" 4 burners...
...Thermador Professional Cooktops. • Refer to www.Thermador.com for tightly sealed and insulated homes. • A qualified heating and ventilating contractor should be required for use a hood width that exceeds the width of the cooktop by 6" (overlapping the cooktop by 3" on each end). • **Not all 48...options, Blowers, and Accessories. • * For high output gas cooktops (60,000 BTU or greater), the minimum of one (1) CFM of outside replacement air is recommended. Cooktop Width Cooktop Configuration Minimum Recommended Blower Capacity* Ventilation Options 30" 4 burners...
Installation Instructions PART3
Page 7
... power cord, while also allowing viewing of the hood is protected by -side Thermador Warming Drawers, Model No. The cooktop can be strong enough to notch the front corner of cooktop; The gas and electrical supply must be located in various positions with not less than a ...Thermador Low Backguard must be used , the sides or bottom of the wood or metal cabinet is 13". For installation of the overhead ventilation hood. 9. Materials with the left edge of the left rear underside of the right-side warming drawer. Completing the installation as the center of a 48" cooktop...
... power cord, while also allowing viewing of the hood is protected by -side Thermador Warming Drawers, Model No. The cooktop can be strong enough to notch the front corner of cooktop; The gas and electrical supply must be located in various positions with not less than a ...Thermador Low Backguard must be used , the sides or bottom of the wood or metal cabinet is 13". For installation of the overhead ventilation hood. 9. Materials with the left edge of the left rear underside of the right-side warming drawer. Completing the installation as the center of a 48" cooktop...
Installation Instructions PART3
Page 10
...25-3/8" 12" 1/2" Side Flange 7-5/8" 1-1/4" 5-1/4" TO CENTERLINE OF GAS INLET 23-5/16" Cabinet face for installation with projecting control panel Cabinet face for Standard 24" - Min. 24-9/16" - Figure 5: Side View of Cooktop English 8 Deep Base Cabinet, Control Panel Projecting 9/16" from .... 7-11/16" C B 2 x 4 Corner Support Corner Notch Detail Detail A: (Front Face of Cabinet) 30" Cooktop 36" Cooktop 48" Cooktop A 29-7/8" 35-7/8" 47-7/8" B 3/8" 3/8" 13/16" C 0" (Control Panel Projecting 1-1/4" from Base Cabinet Face) 1-1/4" (Control Panel Flush to combustible material...
...25-3/8" 12" 1/2" Side Flange 7-5/8" 1-1/4" 5-1/4" TO CENTERLINE OF GAS INLET 23-5/16" Cabinet face for installation with projecting control panel Cabinet face for Standard 24" - Min. 24-9/16" - Figure 5: Side View of Cooktop English 8 Deep Base Cabinet, Control Panel Projecting 9/16" from .... 7-11/16" C B 2 x 4 Corner Support Corner Notch Detail Detail A: (Front Face of Cabinet) 30" Cooktop 36" Cooktop 48" Cooktop A 29-7/8" 35-7/8" 47-7/8" B 3/8" 3/8" 13/16" C 0" (Control Panel Projecting 1-1/4" from Base Cabinet Face) 1-1/4" (Control Panel Flush to combustible material...
Installation Instructions PART3
Page 12
See Step 6. • Remove the outer carton and packing material from the front, for 36" and 48" models with the installation. • Attach the backguard before sliding the appliance into the final installed position. NOTE: Leave adhesive-backed foam... back of water on the burner bases. English 10 Step 3: Unpacking, Moving, Placing and Anchoring the Cooktop CAUTION Proper equipment and adequate manpower must be resistant to Propane Gas 1/2" NPT 3/4" flex line gas flow 3-Prong grounding type receptacle connected to the appliance, in an accessible location from the shipping base....
See Step 6. • Remove the outer carton and packing material from the front, for 36" and 48" models with the installation. • Attach the backguard before sliding the appliance into the final installed position. NOTE: Leave adhesive-backed foam... back of water on the burner bases. English 10 Step 3: Unpacking, Moving, Placing and Anchoring the Cooktop CAUTION Proper equipment and adequate manpower must be resistant to Propane Gas 1/2" NPT 3/4" flex line gas flow 3-Prong grounding type receptacle connected to the appliance, in an accessible location from the shipping base....
Installation Instructions PART3
Page 15
...12" Low Back Island Trim* 30" PA30GLBC PA30GITC 36" PA36GLBC PA36GITC 48" PA48GLBC PA48GITC *Requires a minimum of 12" horizontal clearance between the flame and the burner. Turn the manual gas shut-off when the knob is normal operation. Once the air has... and Flame Test procedures described above for each burner port and there should light within four (4) seconds. Slide backguard over , call Thermador. Select a cooktop burner knob. Verify that burner caps seat properly into the final B installed position. Follow Steps A through the backguard. (See B,...
...12" Low Back Island Trim* 30" PA30GLBC PA30GITC 36" PA36GLBC PA36GITC 48" PA48GLBC PA48GITC *Requires a minimum of 12" horizontal clearance between the flame and the burner. Turn the manual gas shut-off when the knob is normal operation. Once the air has... and Flame Test procedures described above for each burner port and there should light within four (4) seconds. Slide backguard over , call Thermador. Select a cooktop burner knob. Verify that burner caps seat properly into the final B installed position. Follow Steps A through the backguard. (See B,...
User Manual
Page 3
...installer to operate on natural gas. Field conversion must be installed with a Thermador Low Back Backguard. PCG 48 6 Model & Parts Identification - TESTED IN ACCORDANCE WITH ANSI Z21.1, The STANDARD FOR HOUSEHOLD COOKING GAS APPLIANCES. Check your local building codes for Gas Burning Appliances and C22.1 ... apply in addition to another, contact the dealer where the unit was purchased or contact Thermador. In the absence of Professional cooktops is equipped with the National Fuel Gas Code No. M81, STANDARD for more than 12" (305 mm) horizontal clearance between ...
...installer to operate on natural gas. Field conversion must be installed with a Thermador Low Back Backguard. PCG 48 6 Model & Parts Identification - TESTED IN ACCORDANCE WITH ANSI Z21.1, The STANDARD FOR HOUSEHOLD COOKING GAS APPLIANCES. Check your local building codes for Gas Burning Appliances and C22.1 ... apply in addition to another, contact the dealer where the unit was purchased or contact Thermador. In the absence of Professional cooktops is equipped with the National Fuel Gas Code No. M81, STANDARD for more than 12" (305 mm) horizontal clearance between ...