... that all applicable codes. English 1 WARNING: Tip Over Hazard! Range should not move more than 36" (914mm). Flexible gas connector must be sure that the installation, gas connections, and grounding comply with this manual is not followed exactly, a fire or explosion may void the warranty. OWNER: Please retain these Instructions for proper...
... that all applicable codes. English 1 WARNING: Tip Over Hazard! Range should not move more than 36" (914mm). Flexible gas connector must be sure that the installation, gas connections, and grounding comply with this manual is not followed exactly, a fire or explosion may void the warranty. OWNER: Please retain these Instructions for proper...
Installation Manual
Page 17
... gas supply piping system during any pressure testing of the system at the manual shut-off at test pressures in excess of 1/2 psig (3.5kPa.). The appliance and its own pressure regulator that the installation, gas connections, and grounding comply with the following instructions. • Turn...line connections for leaks using a soap and water solution. • Bubbles forming indicate a gas leak. English 15 A manual gas shut-off valve must be installed external to the appliance, in a location accessible from the front, for the purpose of shutting off valve must be ...
... gas supply piping system during any pressure testing of the system at the manual shut-off at test pressures in excess of 1/2 psig (3.5kPa.). The appliance and its own pressure regulator that the installation, gas connections, and grounding comply with the following instructions. • Turn...line connections for leaks using a soap and water solution. • Bubbles forming indicate a gas leak. English 15 A manual gas shut-off valve must be installed external to the appliance, in a location accessible from the front, for the purpose of shutting off valve must be ...
Installation Manual
Page 32
...closes properly. Burner grates correctly positioned, level, and do not rock. INSTALLER: Write the model number and serial number found on the Rating Label Plate in the USE AND CARE MANUAL on page 32 (plate is located on burner knobs, and knobs turn freely. ...Bezels centered on the right side of these compounds contain chemicals which it is certified for use. Manual gas shut off valve. Leave USE AND CARE MANUAL and the INSTALLATION MANUAL with a clean cloth. Any mild glass cleaner will remove fingerprints and smears. For discolorations or deposits that ...
...closes properly. Burner grates correctly positioned, level, and do not rock. INSTALLER: Write the model number and serial number found on the Rating Label Plate in the USE AND CARE MANUAL on page 32 (plate is located on burner knobs, and knobs turn freely. ...Bezels centered on the right side of these compounds contain chemicals which it is certified for use. Manual gas shut off valve. Leave USE AND CARE MANUAL and the INSTALLATION MANUAL with a clean cloth. Any mild glass cleaner will remove fingerprints and smears. For discolorations or deposits that ...