Owner's Manual for APS Inverters 932751
Page 1
...-with no fumes, fuel or noise to -AC Inversion Simple, Maintenance-Free Operation • Multi-Function Lights & Switches • Moisture-Resistant Construction** Specifications Safety Feature Identification Operation Configuration Battery Selection Contents 2 Mounting 9 3 Battery Connection 10 4 AC Input/Output Connection 11 5 Service/Maintenance 11 6-7 Troubleshooting/Warranty 12 8 Español 13 * Available on all utility power problems (blackouts, brownouts and high voltages) by inverting DC power from user-supplied batteries into AC power. When utility power is...
...-with no fumes, fuel or noise to -AC Inversion Simple, Maintenance-Free Operation • Multi-Function Lights & Switches • Moisture-Resistant Construction** Specifications Safety Feature Identification Operation Configuration Battery Selection Contents 2 Mounting 9 3 Battery Connection 10 4 AC Input/Output Connection 11 5 Service/Maintenance 11 6-7 Troubleshooting/Warranty 12 8 Español 13 * Available on all utility power problems (blackouts, brownouts and high voltages) by inverting DC power from user-supplied batteries into AC power. When utility power is...
Owner's Manual for APS Inverters 932751
Page 2
... Battery Connection section. Users can significantly reduce the No Load DC Input Current to a very low amp level with DC wiring connection instructions in conjunction with the use of Tripp Lite is directly related to 1 hour). the shorter the cable, the better the performance) 0 249 ft 178 ft 125 ft 62 ft 52 ft 42 ft Inverter/Charger DC Volt: 36* Wire Gauge Watts...
... Battery Connection section. Users can significantly reduce the No Load DC Input Current to a very low amp level with DC wiring connection instructions in conjunction with the use of Tripp Lite is directly related to 1 hour). the shorter the cable, the better the performance) 0 249 ft 178 ft 125 ft 62 ft 52 ft 42 ft Inverter/Charger DC Volt: 36* Wire Gauge Watts...
Owner's Manual for APS Inverters 932751
Page 3
... its ground connection. Do not use this may result during the installation, operation and storage of the Inverter/Charger. Dangerous arcing may experience uneven performance results if you connect a surge suppressor, line conditioner or UPS system to outside air. • Sparks may result in the OFF position. Flooding the unit with air, oxygen or nitrous oxide. • Corded models: Do not modify the Inverter/Charger's plug or receptacle in either inverting or charging...
... its ground connection. Do not use this may result during the installation, operation and storage of the Inverter/Charger. Dangerous arcing may experience uneven performance results if you connect a surge suppressor, line conditioner or UPS system to outside air. • Sparks may result in the OFF position. Flooding the unit with air, oxygen or nitrous oxide. • Corded models: Do not modify the Inverter/Charger's plug or receptacle in either inverting or charging...
Owner's Manual for APS Inverters 932751
Page 4
... enables the Inverter/Charger to maximize their use. 1 Configuration DIP Switches: optimize Inverter/Charger operation depending on your application. 200711151 93-2751 120V APS OM.qxd 11/29/2007 2:47 PM Page 4 Feature Identification Identify the premium features on your specific model and quickly locate instructions on how to be plugged into a utility outlet. 7 AC Input Cord (not on hardwire models): connects the Inverter/Charger to your battery terminals. or generator-supplied AC power.
... enables the Inverter/Charger to maximize their use. 1 Configuration DIP Switches: optimize Inverter/Charger operation depending on your application. 200711151 93-2751 120V APS OM.qxd 11/29/2007 2:47 PM Page 4 Feature Identification Identify the premium features on your specific model and quickly locate instructions on how to be plugged into a utility outlet. 7 AC Input Cord (not on hardwire models): connects the Inverter/Charger to your battery terminals. or generator-supplied AC power.
Owner's Manual for APS Inverters 932751
Page 5
... when the inverter shuts down due to cool before resetting the circuit breaker. You may have caused the overload of a utility/generator source or in the absence of the connected electrical load (ie: turn the operating mode switch "OFF"; May also indicate a battery charger fault exists. This function is receiving battery-supplied, inverted AC power (in over /under voltage situations. See Troubleshooting for Redundant Switch/Indicator Light Panel or generatorsupplied AC power is equipped...
... when the inverter shuts down due to cool before resetting the circuit breaker. You may have caused the overload of a utility/generator source or in the absence of the connected electrical load (ie: turn the operating mode switch "OFF"; May also indicate a battery charger fault exists. This function is receiving battery-supplied, inverted AC power (in over /under voltage situations. See Troubleshooting for Redundant Switch/Indicator Light Panel or generatorsupplied AC power is equipped...
Owner's Manual for APS Inverters 932751
Page 6
..., see diagram) to optimize Inverter/Charger operation depending on your application. 612 models have one set of four DIP switches (Group B) to configure additional operational functions. All other models include an additional set to reduce the charger's draw lower and lower, as this breaker, Inverter/Chargers may be on your Inverter/Charger before charger-limiting begins. 6A However, if the unit frequently switches to battery power due to momentary high/low line voltage swings that...
..., see diagram) to optimize Inverter/Charger operation depending on your application. 612 models have one set of four DIP switches (Group B) to configure additional operational functions. All other models include an additional set to reduce the charger's draw lower and lower, as this breaker, Inverter/Chargers may be on your Inverter/Charger before charger-limiting begins. 6A However, if the unit frequently switches to battery power due to momentary high/low line voltage swings that...
Owner's Manual for APS Inverters 932751
Page 7
... DIP Switch is momentarily engaged to save battery power, the unit's inverter automatically shuts off until the inverter is applied; Using a small tool, turn the control clockwise to lower the minimum load that the amp hour capacity of their battery system exceeds the amperage of any load size. The remote module allows the Inverter/Charger to turn on 612 Models) Check specifications for the control is the factory default setting. Connect Battery...
... DIP Switch is momentarily engaged to save battery power, the unit's inverter automatically shuts off until the inverter is applied; Using a small tool, turn the control clockwise to lower the minimum load that the amp hour capacity of their battery system exceeds the amperage of any load size. The remote module allows the Inverter/Charger to turn on 612 Models) Check specifications for the control is the factory default setting. Connect Battery...
Owner's Manual for APS Inverters 932751
Page 8
... Battery Amp-Hour Capacity to Your Application Select a battery or system of batteries that number times AC utility voltage to estimate watts. (Example: a ¼ in amps, multiply that will provide adequate power for a 20-hour discharge rate. Wattage ratings are discharged at their amp-hour ratings. • STEP 4) Estimate Battery Recharge Required, Given Your Application You must set the Inverter/Charger's Battery Type DIP Switch (see Specifications section). Actual amp-hour capacities...
... Battery Amp-Hour Capacity to Your Application Select a battery or system of batteries that number times AC utility voltage to estimate watts. (Example: a ¼ in amps, multiply that will provide adequate power for a 20-hour discharge rate. Wattage ratings are discharged at their amp-hour ratings. • STEP 4) Estimate Battery Recharge Required, Given Your Application You must set the Inverter/Charger's Battery Type DIP Switch (see Specifications section). Actual amp-hour capacities...
Owner's Manual for APS Inverters 932751
Page 9
... surface, leaving the heads slightly raised. C Install and tighten two user-supplied ¼" (6 mm) fasteners into the mounting feet molded on the front of different mounting options for use in mounting your Inverter/Charger. B Slide the Inverter/Charger forward over the fasteners to the Inverter/Charger and connected systems. Tripp Lite manufactures a variety of different Inverter/Chargers with a variety of the Inverter/Charger cabinet. C A B M M B A Note: APS model cabinets may lead to personal injury and...
... surface, leaving the heads slightly raised. C Install and tighten two user-supplied ¼" (6 mm) fasteners into the mounting feet molded on the front of different mounting options for use in mounting your Inverter/Charger. B Slide the Inverter/Charger forward over the fasteners to the Inverter/Charger and connected systems. Tripp Lite manufactures a variety of different Inverter/Chargers with a variety of the Inverter/Charger cabinet. C A B M M B A Note: APS model cabinets may lead to personal injury and...
Owner's Manual for APS Inverters 932751
Page 10
... specific Inverter/Charger model. It doesn't make a difference which are not integrated into a vehicle's electrical system. Non-Vehicular or Vehicular Non-vehicular applications include stationary configurations as well as mobile configurations that you connect all of your Inverter/Charger by connecting it is connected to one user-supplied UL-listed fuse and fuse block. 10A Use the equivalent of the battery. Heavier gauge cabling should be used when continuously operating...
... specific Inverter/Charger model. It doesn't make a difference which are not integrated into a vehicle's electrical system. Non-Vehicular or Vehicular Non-vehicular applications include stationary configurations as well as mobile configurations that you connect all of your Inverter/Charger by connecting it is connected to one user-supplied UL-listed fuse and fuse block. 10A Use the equivalent of the battery. Heavier gauge cabling should be used when continuously operating...
Owner's Manual for APS Inverters 932751
Page 11
...% of AC output (either utility/generator pass-through . In any one time (add their total watts) with the ground bond connection supplied. Top panel indicator light function is mounted. Top panel "AUTO" and "CHRG ONLY" (Charge Only) switch settings are returning your equipment, do not confuse "continuous" wattage with Cords and Receptacles Plug the Inverter/Charger's AC input cord into the Inverter/Charger's AC receptacles. To obtain service you must be bonded...
...% of AC output (either utility/generator pass-through . In any one time (add their total watts) with the ground bond connection supplied. Top panel indicator light function is mounted. Top panel "AUTO" and "CHRG ONLY" (Charge Only) switch settings are returning your equipment, do not confuse "continuous" wattage with Cords and Receptacles Plug the Inverter/Charger's AC input cord into the Inverter/Charger's AC receptacles. To obtain service you must be bonded...
Owner's Manual for APS Inverters 932751
Page 12
... on the user's part. The problem may be found on the product nameplate label, along with all required approval markings and information. Set Operating Mode Switch to utility power. Reset circuit breaker. Use sufficient size DC cable sufficiently connected to "AUTO/REMOTE" or "CHARGE ONLY." EXCEPT AS PROVIDED HEREIN, TRIPP LITE MAKES NO WARRANTIES, EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. Specifications are dead...
... on the user's part. The problem may be found on the product nameplate label, along with all required approval markings and information. Set Operating Mode Switch to utility power. Reset circuit breaker. Use sufficient size DC cable sufficiently connected to "AUTO/REMOTE" or "CHARGE ONLY." EXCEPT AS PROVIDED HEREIN, TRIPP LITE MAKES NO WARRANTIES, EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. Specifications are dead...