Owner's Manual for 3-Phase Monitored 0U Power Distribution Units 9332F9 (Multi-language) - Page 1
... MODEL PDU3XVN6G20
(Series Number: AG-00BD)
Important Safety Instructions 2 Service
18
Installation
...3 Warranty and
19
Digital Display
6 Product Registration
Using the Digital Display
9 Español
20
Features
16 Français
39
Configuration and Operation 18
58
1111 W. 35th Street, Chicago, IL 60609 USA • www.tripplite.com/support...
Owner's Manual for 3-Phase Monitored 0U Power Distribution Units 9332F9 (Multi-language) - Page 2
... the PDU to an insecure or unstable surface. • Install in accordance with National Electrical Code standards. Important Safety Instructions
SAVE THESE INSTRUCTIONS
This manual contains instructions and warnings that should be followed during a thunderstorm. • Individual equipment connected to the PDU should be installed near the equipment
and easily accessible. • Do not connect...
Owner's Manual for 3-Phase Monitored 0U Power Distribution Units 9332F9 (Multi-language) - Page 3
...determine the fitness of the rack. The PDU and included hardware are included. Screws for attaching the mounting brackets to the rack.
Installation
Mounting the PDU
Note: The illustrations may differ somewhat from your
rack or rack enclosure to attach the
mounting brackets to the ... rail in
your rack or rack enclosure. (Use the
mounting hardware that came with your PDU model.
Owner's Manual for 3-Phase Monitored 0U Power Distribution Units 9332F9 (Multi-language) - Page 4
Installation
Connecting the PDU
2-1 Each model is equipped with 5-15/20R
outlets)
3 x Double Pole, 20A Branch-Rated
45 Total: 3 Banks of (2) C19, (12)...20A Red IEC 309 30A Blue IEC 309 60A Blue IEC 309
CS8365C 3P + N + E
3P + E
3P + E
Model Name
Input Plug
Max Input Amps (Limited by Input Cord
and Plug)
Input Voltage Range
Output Voltage Range
Cord Breakers Length
Outlets
PDU3VN6L2120...
Owner's Manual for 3-Phase Monitored 0U Power Distribution Units 9332F9 (Multi-language) - Page 5
... receptacle.
2-2
LINE L1-L2
2-3
2-4
L1L2
A
Networking the PDU
Your PDU can find the guide by going to DB9 configuration cable (part number 73-1243) included with the PDU.
5
14-07-037-9332F9.indb 5
8/15/2014 3:13:09 PM For Installation Purposes Only
2-3 Connect your facility's compatible AC power source. To unplug equipment properly...
Owner's Manual for 3-Phase Monitored 0U Power Distribution Units 9332F9 (Multi-language) - Page 7
...L2-N L2-L3 L3-L1
LINE L2-L3 BANK 2
L2L3
BANK 2
BANK 6 120V
L3L1
BANK 3
MODELS
PDU3VN6L2120 PDU3VN6L2130
SILKSCREEN LABEL DESCRIPTION L1-L2 L2-L3 L3-L1
L1-N (Bank 4) L3-N (Bank 5)...for a given configuration category.
1 Configured via Configuration Category item "Outlet Indicator LED Color Code Options". Up Pushbutton
Depress ½ sec Depress 3 sec
Sequentially, moves down one selection ...
Owner's Manual for 3-Phase Monitored 0U Power Distribution Units 9332F9 (Multi-language) - Page 9
...
Scrolling Through Input Phases and Options (Measurement Category)
Press Mode button to -neutral voltages. The scrolling pattern of the arrow buttons switches between menus. Select models display phase-to toggle between measurement categories. A long press skips between options and data within a menu.
Owner's Manual for 3-Phase Monitored 0U Power Distribution Units 9332F9 (Multi-language) - Page 10
... displayed are phase-to -neutral voltages. i 8
Bank #2
Volts*
2 0 8
continued on next page
i 0.5
14-07-037-9332F9.indb 10
10
2. Select models display phase-to -phase voltages (i.e., b1 display will indicate L1-L2 voltage). Unbalanced Load Detect (Measurement Category) Phase Imbalance %
2 0
Scrolling Through Load Banks and Options (...
Owner's Manual for 3-Phase Monitored 0U Power Distribution Units 9332F9 (Multi-language) - Page 11
i 8
2 0 8
To Total Output Power
Note: Continue for Load Banks 4-6 for models PDU3VN6G60C, PDU3VN6L2120 and
i.2 3 PDU3VN6L2130. A long press skips between options and data within a menu.
The scrolling pattern of the arrow buttons switches between menus. i 0.5 2. A momentary press ...
Owner's Manual for 3-Phase Monitored 0U Power Distribution Units 9332F9 (Multi-language) - Page 13
... 13
8/15/2014 3:13:18 PM The number in the 2-digit display is defined as: 1=25%; 2=50%; 3=75%; 4=100%
4
I
2
3I
2I
2
Bank Indicator LED Color Code Options (Configuration Category)
I
2
Hold the Mode button for 3 seconds to switch between options.
Owner's Manual for 3-Phase Monitored 0U Power Distribution Units 9332F9 (Multi-language) - Page 15
... ii
00 33..00
At any point, pressing both of the arrow buttons simultaneously for 3 seconds to test the display. Please visit www.tripplite.com/support for issues with display segment or Indicator LED functionality.
88 88 88
8888
Viewing the IP Address
ii PP
At any point, pressing both of...
Owner's Manual for 3-Phase Monitored 0U Power Distribution Units 9332F9 (Multi-language) - Page 16
... does not include C19 receptacles. Circuit Breaker (Select Models): Each Load Bank is below the Low Voltage threshold. Note: Each breaker comes equipped with a push-to-reset guard to -Reset Guard
Note: Colors noted here reflect standard LED configuration.
Mounting Buttons: Come pre-installed on , each Bank Status LED will trip. PDUMVROTATEBRKT...
Owner's Manual for 3-Phase Monitored 0U Power Distribution Units 9332F9 (Multi-language) - Page 17
...part number 73-1243) is secure.
An RJ45 to connect any equipment that the fit is secure. Ethernet Port: Use this port to provide a direct terminal connection to the network with the PDU. The Link LED A and Status LED B indicate several operating conditions, as shown in the SNMPWEBCARD installation guide...Initialized and Operational Error - C20 Plug...www.tripplite.com/support and typing "...
Owner's Manual for 3-Phase Monitored 0U Power Distribution Units 9332F9 (Multi-language) - Page 18
.... Mark the RMA number on service, visit www.tripplite.com/support. Service
Your Tripp Lite product is required for service, follow these steps:
1. If the problem requires service, visit www.tripplite.com/support and click the Product Returns link. Review the installation and operation procedures in this manual. Return the product for your unit's model and serial numbers, along with...
Owner's Manual for 3-Phase Monitored 0U Power Distribution Units 9332F9 (Multi-language) - Page 19
...shielded cables and connectors with part 15 of this product, always refer to correct the interference at his own expense. Seller will repair or replace the product, in accordance...model number of initial purchase. When requesting compliance information for a chance to : Tripp Lite, 1111 W. 35th Street, Chicago, IL 60609 USA. Visit www.tripplite.com/support before sending any specific ...