Warranty Information
Page 1
... serial number has been altered or removed from your sales slip together for Factory Specified Parts and repair labor to published user or operator instructions and/or installation instructions. 4. Major appliances with the product, Whirlpool Corporation or Whirlpool Canada LP (hereafter "Whirlpool") will need to know your major appliance to correct house wiring or plumbing. 2. DISCLAIMER OF IMPLIED WARRANTIES; This limited warranty is valid only in the United States or Canada...
... serial number has been altered or removed from your sales slip together for Factory Specified Parts and repair labor to published user or operator instructions and/or installation instructions. 4. Major appliances with the product, Whirlpool Corporation or Whirlpool Canada LP (hereafter "Whirlpool") will need to know your major appliance to correct house wiring or plumbing. 2. DISCLAIMER OF IMPLIED WARRANTIES; This limited warranty is valid only in the United States or Canada...
Installation Guide
Page 3
... manufacturer. ■ Before servicing or cleaning the unit, switch power off the burner. When the service disconnecting means cannot be done by NFPA. ■ WARNING: To reduce the risk of fire or electrical shock, do not vent exhaust air into spaces within walls or ceilings, attics or into wall or ceiling; Crepes Suzette, Cherries Jubilee, Peppercorn Beef Flambé). ■ Clean ventilating fans frequently. You know how...
... manufacturer. ■ Before servicing or cleaning the unit, switch power off the burner. When the service disconnecting means cannot be done by NFPA. ■ WARNING: To reduce the risk of fire or electrical shock, do not vent exhaust air into spaces within walls or ceilings, attics or into wall or ceiling; Crepes Suzette, Cherries Jubilee, Peppercorn Beef Flambé). ■ Clean ventilating fans frequently. You know how...
Installation Guide
Page 4
... filler strips). Length and thickness determined by recess dimensions. ■ Four flat head wood screws or machine screws with installation clearances specified on the left wall. ■ Range hood location should be installed must conform to comply with washers and nuts (to 6" (15.2 cm) or larger diameter transition piece if using 6" (15.2 cm) or larger diameter round vent system. ■ 3 - UL listed wire connectors For cabinets with local codes. Given dimensions...
... filler strips). Length and thickness determined by recess dimensions. ■ Four flat head wood screws or machine screws with installation clearances specified on the left wall. ■ Range hood location should be installed must conform to comply with washers and nuts (to 6" (15.2 cm) or larger diameter transition piece if using 6" (15.2 cm) or larger diameter round vent system. ■ 3 - UL listed wire connectors For cabinets with local codes. Given dimensions...
Installation Guide
Page 5
... Air Local building codes may require the use 6" (15.2 cm) or larger round damper (purchased separately) C. Round vent: use of make up air systems when using ventilation systems greater than 1 elbow is not recommended. ■ The length of vent system and number of elbows should be installed to minimize conduction of outside temperatures as possible to where the vent system enters the heated portion of range hood to 6" (15.2 cm) or larger diameter transition...
... Air Local building codes may require the use 6" (15.2 cm) or larger round damper (purchased separately) C. Round vent: use of make up air systems when using ventilation systems greater than 1 elbow is not recommended. ■ The length of vent system and number of elbows should be installed to minimize conduction of outside temperatures as possible to where the vent system enters the heated portion of range hood to 6" (15.2 cm) or larger diameter transition...
Installation Guide
Page 6
..." (8.3 cm x 25.4 cm) system = 5.0 ft (1.5 m) = 8.0 ft (2.4 m) = 0.0 ft (0.0 m) = 13.0 ft (3.9 m) 6 wall cap Length of the system you need, add the equivalent feet (meters) for each vent piece used in the system. 6" (15.2 cm) or Larger Round Vent System Vent Piece Round 45° elbow 2.5 ft (0.8 m) 3¹⁄₄" x 10" (8.3 cm x 25.4 cm) Vent System Vent Piece 3¹⁄₄" x 10" (8.3 cm x 25.4 cm) 5.0 ft...
..." (8.3 cm x 25.4 cm) system = 5.0 ft (1.5 m) = 8.0 ft (2.4 m) = 0.0 ft (0.0 m) = 13.0 ft (3.9 m) 6 wall cap Length of the system you need, add the equivalent feet (meters) for each vent piece used in the system. 6" (15.2 cm) or Larger Round Vent System Vent Piece Round 45° elbow 2.5 ft (0.8 m) 3¹⁄₄" x 10" (8.3 cm x 25.4 cm) Vent System Vent Piece 3¹⁄₄" x 10" (8.3 cm x 25.4 cm) 5.0 ft...
Installation Guide
Page 7
... Electrical Code, Part 1 and C22.2 No. 0-M91 (latest edition) and all local codes and ordinances. Connect a section of copper wire using special connectors and/or tools designed and UL listed for exhaust vent. 1. The model/serial plate is adequate and in the area the vent opening will be made. 4. Determine which venting method to attach filler strips in locations shown. Wood filler strips (recessed cabinet bottoms only) 3" (7.6 cm) A Cabinet bottom 3" (7.6 cm) Wall...
... Electrical Code, Part 1 and C22.2 No. 0-M91 (latest edition) and all local codes and ordinances. Connect a section of copper wire using special connectors and/or tools designed and UL listed for exhaust vent. 1. The model/serial plate is adequate and in the area the vent opening will be made. 4. Determine which venting method to attach filler strips in locations shown. Wood filler strips (recessed cabinet bottoms only) 3" (7.6 cm) A Cabinet bottom 3" (7.6 cm) Wall...
Installation Guide
Page 8
... the underside of cabinet. 3. Use saber or keyhole saw to cut a rectangular opening for 3¼" x 10" (8.3 x 25.4 cm) Rectangular Vent to cut the circular vent opening *5" (12.7 cm) Cabinet cutouts *From wall, not cabinet frame 8 Drill a 1¹⁄₄" (3.2 cm) diameter hole through wall: Mark a line distance "A" from the underside of the cabinet top: 1. Use saber or keyhole saw to Round Vent Transition Roof Venting To make a 4¹⁄...
... the underside of cabinet. 3. Use saber or keyhole saw to cut a rectangular opening for 3¼" x 10" (8.3 x 25.4 cm) Rectangular Vent to cut the circular vent opening *5" (12.7 cm) Cabinet cutouts *From wall, not cabinet frame 8 Drill a 1¹⁄₄" (3.2 cm) diameter hole through wall: Mark a line distance "A" from the underside of the cabinet top: 1. Use saber or keyhole saw to Round Vent Transition Roof Venting To make a 4¹⁄...
Installation Guide
Page 9
... mounting screws in upper cabinet or wall. NOTE: Do not reconnect power until the installation is directly behind the vent connector, the dampers in the hood electrical terminal box. See "Venting Requirements" section. 2. Install Range Hood Complete Preparation 1. Use ¹⁄₈" (3 mm) drill bit and drill 4 pilot holes as shown. ■ Depending on a covered surface. Remove the grease filters. Drill pilot hole. 4. Vertical vent B. Horizontal vent NOTE: If the wall cap is complete. 6. NOTE: The exhaust adaptor/damper...
... mounting screws in upper cabinet or wall. NOTE: Do not reconnect power until the installation is directly behind the vent connector, the dampers in the hood electrical terminal box. See "Venting Requirements" section. 2. Install Range Hood Complete Preparation 1. Use ¹⁄₈" (3 mm) drill bit and drill 4 pilot holes as shown. ■ Depending on a covered surface. Remove the grease filters. Drill pilot hole. 4. Vertical vent B. Horizontal vent NOTE: If the wall cap is complete. 6. NOTE: The exhaust adaptor/damper...
Installation Guide
Page 10
... push the hood toward the wall so that back draft dampers work properly. See "Replacing the Fluorescent Lamp" in the neck of the range hood fan and light. Check that the screws are over the mounting screws. Make Electrical Connection WARNING Electrical Shock Hazard Disconnect power before operating. If range hood does not operate, check to hood. Tip the terminal box cover at the screw flange area to make secure and airtight. 12. Use UL listed wire connectors and connect white wires (A) together. 3. Reconnect power.
... push the hood toward the wall so that back draft dampers work properly. See "Replacing the Fluorescent Lamp" in the neck of the range hood fan and light. Check that the screws are over the mounting screws. Make Electrical Connection WARNING Electrical Shock Hazard Disconnect power before operating. If range hood does not operate, check to hood. Tip the terminal box cover at the screw flange area to make secure and airtight. 12. Use UL listed wire connectors and connect white wires (A) together. 3. Reconnect power.
Installation Guide
Page 11
... lamp housing B. Cleaning Method: ■ Rub in direction of the range hood. Blower speed medium button D. Operating the blower The BLOWER SPEED buttons turn the blower off the range hood and allow it to operate several minutes after the cooking is complete to remove smoke, cooking vapors and odors from the kitchen. A. Wash metal filters as needed in spring release handle. 5. Disconnect power. 2. C A B A. Reconnect power. Push up on and control the blower speed and sound level for GX24 base. 4. Screw B. Blower and light controls D. Grease filter Range Hood...
... lamp housing B. Cleaning Method: ■ Rub in direction of the range hood. Blower speed medium button D. Operating the blower The BLOWER SPEED buttons turn the blower off the range hood and allow it to operate several minutes after the cooking is complete to remove smoke, cooking vapors and odors from the kitchen. A. Wash metal filters as needed in spring release handle. 5. Disconnect power. 2. C A B A. Reconnect power. Push up on and control the blower speed and sound level for GX24 base. 4. Screw B. Blower and light controls D. Grease filter Range Hood...
Installation Guide
Page 12
Black 56.5 Motor Characteristics Power Supply 120 VAC Frequency 60 Hz Power Absorption 144 Watts Current 1.2 A W R BR Y GY R BK BK 123 4567 GND Chassis GND Electrical Support GY R BK 1234 56 BK GY R Y BR 32 4 R BK 25 uF 15 uF Y/G R BK S30 L 1 BU 12 uF W 12 W Y/G WIRING DIAGRAM N GND L B K EMI Filter BK R W R BK Ballast BU BU W Y/G Y/G BK BK BK W Y/G Motor Resistance (Ohms) Red -
Black 56.5 Motor Characteristics Power Supply 120 VAC Frequency 60 Hz Power Absorption 144 Watts Current 1.2 A W R BR Y GY R BK BK 123 4567 GND Chassis GND Electrical Support GY R BK 1234 56 BK GY R Y BR 32 4 R BK 25 uF 15 uF Y/G R BK S30 L 1 BU 12 uF W 12 W Y/G WIRING DIAGRAM N GND L B K EMI Filter BK R W R BK Ballast BU BU W Y/G Y/G BK BK BK W Y/G Motor Resistance (Ohms) Red -
Installation Guide
Page 13
... provide assistance with: ■ Features and specifications on our full line of appliances. ■ Installation information. ■ Use and maintenance procedures. ■ Accessory and repair parts sales. ■ Specialized customer assistance (Spanish speaking, hearing impaired, limited vision, etc.). ■ Referrals to Whirlpool Canada LP with the same precision used to local dealers, repair parts distributors, and service companies. Whirlpool designated service technicians are made with any questions...
... provide assistance with: ■ Features and specifications on our full line of appliances. ■ Installation information. ■ Use and maintenance procedures. ■ Accessory and repair parts sales. ■ Specialized customer assistance (Spanish speaking, hearing impaired, limited vision, etc.). ■ Referrals to Whirlpool Canada LP with the same precision used to local dealers, repair parts distributors, and service companies. Whirlpool designated service technicians are made with any questions...
Installation Guide
Page 14
... need service, first see the "Troubleshooting" section of the Use & Care Guide. WHIRLPOOL CORPORATION MAJOR APPLIANCE WARRANTY LIMITED WARRANTY For one year from the date of purchase, when this major appliance is operated and maintained according to instructions attached to or furnished with the product, Whirlpool Corporation or Whirlpool Canada LP (hereafter "Whirlpool") will need to know your major appliance, to replace or repair house fuses, or to correct house wiring...
... need service, first see the "Troubleshooting" section of the Use & Care Guide. WHIRLPOOL CORPORATION MAJOR APPLIANCE WARRANTY LIMITED WARRANTY For one year from the date of purchase, when this major appliance is operated and maintained according to instructions attached to or furnished with the product, Whirlpool Corporation or Whirlpool Canada LP (hereafter "Whirlpool") will need to know your major appliance, to replace or repair house fuses, or to correct house wiring...
Dimension Guide
Page 1
...;₄" x 10" (8.3 x 25.4 cm) with a maximum vent length of 35 ft (10.7 m) or 6" (15.2 cm) or larger round vent with product. ® 30" (76.2 CM) Range Hood PRODUCT MODEL NUMBERS GXU7130DX ELECTRICAL REQUIREMENTS • A 120 Volt, 60 Hz., AC only, 15-amp, fused electrical circuit is not recommended. Round vent: use 6" (15.2 cm) or larger round damper (purchased separately) C. Roof Venting A E B Wall Venting A B C E C D D A. 6" (15.2 cm) or larger round vent or a 3¹⁄₄" x 10" (8.3 x 25...
...;₄" x 10" (8.3 x 25.4 cm) with a maximum vent length of 35 ft (10.7 m) or 6" (15.2 cm) or larger round vent with product. ® 30" (76.2 CM) Range Hood PRODUCT MODEL NUMBERS GXU7130DX ELECTRICAL REQUIREMENTS • A 120 Volt, 60 Hz., AC only, 15-amp, fused electrical circuit is not recommended. Round vent: use 6" (15.2 cm) or larger round damper (purchased separately) C. Roof Venting A E B Wall Venting A B C E C D D A. 6" (15.2 cm) or larger round vent or a 3¹⁄₄" x 10" (8.3 x 25...
Dimension Guide
Page 2
...;⁄₄" x 10" (8.3 cm x 0.0 ft (0.0 m) 25.4 cm) wall cap Example vent system 3¹⁄₄" x 10" (8.3 x 25.4 cm) elbow 6 ft (1.8 m) Wall cap 2 ft (0.6 m) Maximum Recommended Length = 35 ft (10.7 m) 1 - 90° elbow 8 ft (2.4 m) straight 1 - clearance - upper cabinet to cooking surface C. 30" (76.2 cm) min. Specifications subject to change without notice. bottom of range hood to countertop B. 24" (61.0 cm) min. W10320576A 10/20/10 for...
...;⁄₄" x 10" (8.3 cm x 0.0 ft (0.0 m) 25.4 cm) wall cap Example vent system 3¹⁄₄" x 10" (8.3 x 25.4 cm) elbow 6 ft (1.8 m) Wall cap 2 ft (0.6 m) Maximum Recommended Length = 35 ft (10.7 m) 1 - 90° elbow 8 ft (2.4 m) straight 1 - clearance - upper cabinet to cooking surface C. 30" (76.2 cm) min. Specifications subject to change without notice. bottom of range hood to countertop B. 24" (61.0 cm) min. W10320576A 10/20/10 for...