Product Manaul
Page 1
EN User manual Gas hob ZGG75524 ZGG76524 IE PK GB
EN User manual Gas hob ZGG75524 ZGG76524 IE PK GB
Product Manaul
Page 2
... the dimensions of the cooking surface www.zanussi.com Use • Remove all packaging away from the appliance during and after use . Flames can tip over the edges of the burners. Children must not be used for other purposes, for commercial and industrial use this manual carefully before first use the appliance. There is cold. It can use . Cookware and its contents can heat up the pan...
... the dimensions of the cooking surface www.zanussi.com Use • Remove all packaging away from the appliance during and after use . Flames can tip over the edges of the burners. Children must not be used for other purposes, for commercial and industrial use this manual carefully before first use the appliance. There is cold. It can use . Cookware and its contents can heat up the pan...
Product Manaul
Page 3
... operate the appliance with intensity for a long time. • Carefully obey the instructions for electrical connections. from a dishwasher or oven. • Do not install the appliance adjacent to doors and below the appliance. • Prevent damage of the cut surfaces of the worktop against moisture with a correct sealant. • Seal the appliance to the worktop with no space left...
... operate the appliance with intensity for a long time. • Carefully obey the instructions for electrical connections. from a dishwasher or oven. • Do not install the appliance adjacent to doors and below the appliance. • Prevent damage of the cut surfaces of the worktop against moisture with a correct sealant. • Seal the appliance to the worktop with no space left...
Product Manaul
Page 4
..., B.S. 5440 Part 2 Current Edition, should not be located in accordance with the Gas Safety (Installation and Use) Regulations (Current Edition) and the IEE Wiring Regulations (Current Edition). The following British Standards Codes Of Practice: B.S. 6172/ B.S. 5440, Par. 2 and B.S. 6891 Current Editions. Provision for Electrical Installations. Location The hob may be installed in the Republic of Ireland please refer to determine the requisite air vent requirements. Installation •...
..., B.S. 5440 Part 2 Current Edition, should not be located in accordance with the Gas Safety (Installation and Use) Regulations (Current Edition) and the IEE Wiring Regulations (Current Edition). The following British Standards Codes Of Practice: B.S. 6172/ B.S. 5440, Par. 2 and B.S. 6891 Current Editions. Provision for Electrical Installations. Location The hob may be installed in the Republic of Ireland please refer to determine the requisite air vent requirements. Installation •...
Product Manaul
Page 5
... semi-rigid pipe, i.e. Remove the knob. edges of Appliance. Domestic Gas Installation I.S 813 Current Edition Section 7Permitted Locations of the hob is carried out on the minimum position. 3. Screw the parts together without using metal rigid pipes (copper with mechanical end). When the final connection has been made, it is easily accessible for the type of gas supply. Light the burner. 2. If it...
... semi-rigid pipe, i.e. Remove the knob. edges of Appliance. Domestic Gas Installation I.S 813 Current Edition Section 7Permitted Locations of the hob is carried out on the minimum position. 3. Screw the parts together without using metal rigid pipes (copper with mechanical end). When the final connection has been made, it is easily accessible for the type of gas supply. Light the burner. 2. If it...
Product Manaul
Page 6
... the flame does not go out when you change the fuse, use a correctly installed shockproof socket. • Make sure that the ground connection complies with an extension cable, an adapter or a multiple socket. The manufacturer declines any hot parts. • The electrical installation must not touch any liability if these safety measures are not observed. Electrical Requirements Permanent electrical installation must not be heated to liquid gas...
... the flame does not go out when you change the fuse, use a correctly installed shockproof socket. • Make sure that the ground connection complies with an extension cable, an adapter or a multiple socket. The manufacturer declines any hot parts. • The electrical installation must not touch any liability if these safety measures are not observed. Electrical Requirements Permanent electrical installation must not be heated to liquid gas...
Product Manaul
Page 7
...) wire to the voltage and the working temperature. Neutral - 1 2 3 4 5 Important! Make sure that the cut or stray strands of electrical shock. The cord clamp must be no cut off plug put into a 13 amp socket is marked with the following code: Green and yellow Blue Brown - Warning! Replacement of the connection cable To replace the connection cable use only H05V2V2-F T90 or equivalent type.
...) wire to the voltage and the working temperature. Neutral - 1 2 3 4 5 Important! Make sure that the cut or stray strands of electrical shock. The cord clamp must be no cut off plug put into a 13 amp socket is marked with the following code: Green and yellow Blue Brown - Warning! Replacement of the connection cable To replace the connection cable use only H05V2V2-F T90 or equivalent type.
Product Manaul
Page 8
... cm2 a) Removable panel b) Space for approximately 5 seconds; this will be interrupted. The electrical connection of the hob and the oven must be equipped Product description Cooking surface layout 360 cm2 1 2 1 Semi-rapid burner 3 2 Triple Crown burner 3 Rapid burner 4 4 Auxiliary burner 5 Control knobs 5 180 cm2 Control knobs Symbol Description no gas supply / off position Symbol Description ignition position / maximum gas supply minimum gas supply Operation Ignition of the flame Always light the burner before you...
... cm2 a) Removable panel b) Space for approximately 5 seconds; this will be interrupted. The electrical connection of the hob and the oven must be equipped Product description Cooking surface layout 360 cm2 1 2 1 Semi-rapid burner 3 2 Triple Crown burner 3 Rapid burner 4 4 Auxiliary burner 5 Control knobs 5 180 cm2 Control knobs Symbol Description no gas supply / off position Symbol Description ignition position / maximum gas supply minimum gas supply Operation Ignition of the flame Always light the burner before you...
Product Manaul
Page 9
... when you remove the pans from the burner. 1 Burner cap 2 Burner crown 3 Ignition candle 4 Thermocouple Helpful hints and tips Energy savings • If possible, always put the flame out, turn the knob to maximum gas release position. 3. Do not keep the control knob pushed for more than 15 seconds. If the burner does not light after minimum 1 minute. Warning! Warning! Adjust the flame after installation or a power cut. Turning the burner off To...
... when you remove the pans from the burner. 1 Burner cap 2 Burner crown 3 Ignition candle 4 Thermocouple Helpful hints and tips Energy savings • If possible, always put the flame out, turn the knob to maximum gas release position. 3. Do not keep the control knob pushed for more than 15 seconds. If the burner does not light after minimum 1 minute. Warning! Warning! Adjust the flame after installation or a power cut. Turning the burner off To...
Product Manaul
Page 10
... electrical supply before you clean it. After cleaning, dry the appliance with a soft cloth. • The pan supports are not recommended. The stainless steel can cause damage to prevent damage the top during operation. Removing the dirt: 1. - Do not use aluminium foil to the appliance. Flame will heat up the control zone. They must not enter the control zone. Do not use abrasive cleaners, steel...
... electrical supply before you clean it. After cleaning, dry the appliance with a soft cloth. • The pan supports are not recommended. The stainless steel can cause damage to prevent damage the top during operation. Removing the dirt: 1. - Do not use aluminium foil to the appliance. Flame will heat up the control zone. They must not enter the control zone. Do not use abrasive cleaners, steel...
Product Manaul
Page 11
... difficult lighting and check that the unit is connected and the electrical supply is obtained through a ceramic ignition candle with food residues Remedy • Make sure that the burner crown holes are in correct positions. • After lightning the flame, keep the knob pushed for surface of the gas supply pipe and the pressure adjuster, if fitted. Clean the appliance with a clean cloth. www.zanussi...
... difficult lighting and check that the unit is connected and the electrical supply is obtained through a ceramic ignition candle with food residues Remedy • Make sure that the burner crown holes are in correct positions. • After lightning the flame, keep the knob pushed for surface of the gas supply pipe and the pressure adjuster, if fitted. Clean the appliance with a clean cloth. www.zanussi...
Product Manaul
Page 12
... on the supplied rating plate. • Model description Technical data • Product number (PNC • Serial Number (S.N Use the original spare parts only. SER.NO. If you quickly and correctly. PROD.NO. They are necessary to help you operated the appliance incorrectly, or the installation was not carried out by a registered engineer, the visit from the customer service technician or dealer...
... on the supplied rating plate. • Model description Technical data • Product number (PNC • Serial Number (S.N Use the original spare parts only. SER.NO. If you quickly and correctly. PROD.NO. They are necessary to help you operated the appliance incorrectly, or the installation was not carried out by a registered engineer, the visit from the customer service technician or dealer...
Product Manaul
Page 13
... the recycling of electrical and electronic equipment. tridge fuse II2H3+ G 1/2" Gas supply: Appliance class: G20 (2H) 20 mbar 3 By-pass diameters Burner Auxiliary Semi-rapid Rapid Triple Crown Ø By-pass in 1/100 mm 28 32 42 56 Gas burners BURNER NORMAL POWER kW Auxiliary Semi-rapid Rapid Triple Crown 1.0 2.0 3.0 (natural gas) 2.8 (LPG) 4.0 REDUCED POWER kW 0.33 0.45 NORMAL POWER NATURAL GAS G20 (2H...
... the recycling of electrical and electronic equipment. tridge fuse II2H3+ G 1/2" Gas supply: Appliance class: G20 (2H) 20 mbar 3 By-pass diameters Burner Auxiliary Semi-rapid Rapid Triple Crown Ø By-pass in 1/100 mm 28 32 42 56 Gas burners BURNER NORMAL POWER kW Auxiliary Semi-rapid Rapid Triple Crown 1.0 2.0 3.0 (natural gas) 2.8 (LPG) 4.0 REDUCED POWER kW 0.33 0.45 NORMAL POWER NATURAL GAS G20 (2H...