Top Cap For Rv36
I am looking to replace the white top cap of my Dacor RV36S with a stainless or aluminum one. Is that possible?
Current Answers
There are currently no answers that have been posted for this question.
Be the first to post an answer! Remember that you can earn up to 1,100 points for every answer you submit. The better the quality of your answer, the better chance it has to be accepted.
Be the first to post an answer! Remember that you can earn up to 1,100 points for every answer you submit. The better the quality of your answer, the better chance it has to be accepted.
Related Dacor RV36 Manual Pages
Planning Guides - Page 1
.... All tolerances: +1/16", -0, (+1.6 mm, -0) unless otherwise stated
Model Number
RV30
RV36
RV46
Vent shown in accordance with a single Dacor approved cabinet, remote or in -line blowers, refer to
34"
(864 mm)
4...the particular appliance for approved blowers. For detailed information on the remote and in -line blower. Top Cap Width
30" (762 mm)
36" (914 mm)
46" (1168 mm)
B - Chassis Width
...
Planning Guides - Page 2
...vent, blower and cooktop so that the electrical connection of the raised vent itself and a single Dacor approved remote blower or internal cabinet blower. Raised Vent Model No. Cabinet blower
Connection to cabinet ... 15 Amps.
■■ The above the cooktop should be solid and at right angles. RV30, RV36, RV46
Document # PG08-003
30", 36", 46" Wide, Raised Vent
Revised 03/29/10 Page ...
Planning Guides - Page 3
... bottom or through rear wall to accompanying installation instructions. www.Dacor.com Phone: (800) 793-0093
8.9 Allow room for the exhaust duct coming out of the sides.
See Planning the Duct Work for Gas Cooktop Installations - Side View
Internal cabinet blower
Wall cap
3 1/4" x 10" 90˚ elbow
floor
Duct directly through one...
Planning Guides - Page 4
www.Dacor.com Phone: (800) 793-0093
8.10 RV30, RV36, RV46
Document # PG08-003
30", 36", 46" Wide, Raised Vent
General System Layout (continued)
Revised 03/29/10 Page 4/7
PLANNING GUIDE
Cooktop
Cabinet back
Raised vent
Raised vent configured for bottom exhaust
3 1/4" X 10" to round transition
Outside wall
Floor
Wall cap on outside wall...
Planning Guides - Page 5
...odors from the hood exhaust as possible, with as much space between each bend as possible. Only one ...Dacor blower models listed below for the shortest, most direct route to the outside the house or building. Also allow the duct work to pass through.
■■ All duct work , always look...Document # PG08-003
Planning the Duct Work
RV30, RV36, RV46
30", 36", 46" Wide, Raised Vent
...
Planning Guides - Page 6
...Side Dimensions for in any orientation (bottom, or side exahust)
Front Exhaust Dimensions CABP3 Blower - www.Dacor.com
B 6" (152 mm) 9" (229 mm)
C 12" (205 mm) 9" (229 ...Internal cabinet blower mounting location
Exhaust Locations and Dimensions for CABP3 Internal Cabinet Blower
Model
RV30 RV36
RV46
A 2" (51 mm) 5" (127 mm)
Specifications subject to accompanying installation instructions...
Planning Guides - Page 7
... of the equivalent lengths of roof and wall caps vary with model and configuration. www.Dacor.com Phone: (800) 793-0093
8.13
Blower...9632; For best performance, keep the duct run as short as possible and never exceed the maximums stated at the right.
■■...transition (see table) must be used .
Document # PG08-003
RV30, RV36, RV46
30", 36", 46" Wide, Raised Vent
Revised 03/29/...
Installation Instructions - Page 1
See the installation instructions for optional cabinet blower (Dacor model CABP3)
Part No. 85515 Rev. H
Use these downdraft raised vents only with approved Dacor ® cooktops. Installation Instructions Downdraft Raised Vent
Models: RV30, RV36, RV46
Includes installation instructions for the particular cooktop model being
installed to determine suitability.
Installation Instructions - Page 2
... product data label also specifies the power supply requirements. Pacific Time
Web site: www.Dacor.com
Dacor Distinctive Service (repairs under warranty call , have questions or problems with the latest edition...858 household electrical ranges, CAN/CSA-C22.2 NO. 64 Standard for future reference and the local building inspector's use. Pacific Time
RV30 = 30-inch wide raised vent RV36 = 36-inch...
Installation Instructions - Page 3
...gasoline) inside or in accordance with all possible problems and conditions that WILL result in ...
If you don't understand. b) Always turn hood ON when cooking at high settings. Use common...qualified person(s) in the vicinity of a range top grease fire:
a) Never leave surface ... other appliance.
• Always contact the Dacor Customer Service Team about problems and conditions that...
Installation Instructions - Page 4
...appliance is not equipped with these installation instructions the Dacor cooktop installation instructions and the remote or in use... to sit or stand on top of the vent top cap. Contact your local building department for commercial use and care...not use only. A qualified service technician should not install, repair or replace any way.
2 Do not store items of interest to children above ...
Installation Instructions - Page 5
...Tolerances: ±1/16" (±1.6 mm) unless otherwise stated
1 15/16" (49 mm)
1/2" (13 mm) thick stiffener
across back
1 13/16" (46 mm)
Top cap with vent down
15/16" (24 mm)
3 1/8" (79 mm)
3/16" (5 mm)
9/16" (14 mm)
2" (51 mm)
2 5/16" (59 mm)...34"
(864 mm)
4 5/8" (117 mm)
9 7/8" (251 mm) with CABP3 blower installed
Adjustable anchor legs Front View
Model Number
RV30
RV36
RV46
A -
Installation Instructions - Page 9
... see the instructions later in " the duct work , always look for bottom exhaust and use an elbow to vent through the rear....
• Cross-drafts or air currents from the hood exhaust as possible, with the exhaust pointing in the floor to determine if...adjacent elbows.
• Do not use round duct instead of the Dacor blower models listed below for actual rating.
** Nominal rating at zero...
Installation Instructions - Page 10
... Dimensions for Remote or In-line Blower Configurations
(ILHSF and REMP series blowers)
3 1/4 X 10 Duct connection
Front Exhaust Dimensions CABP3 Blower - Left Exhaust
Model
RV30 RV36
RV46
A
B
2" (51 mm) 6" (152 mm)
5" (127 mm) 9" (229 mm)
C 12" (205 mm) 9" (229 mm) Bottom Exhaust
Raised vent Countertop center line
B
11 5/8" (295 mm)
3 1/4 X 10...
Installation Instructions - Page 16
...
If the raised vent still does not function after installation:
• Make sure that the top cap on the raised vent intake does not catch on the raised vent? Are the anchor legs fastened ...;□ Is the duct work completely installed? Replace the vent cover or cabinet blower and make sure the speed changes
or the blower turns off. Dacor is being supplied to the raised vent and ...
Use & Care Manuals - Page 1
G Model RV30 shown. Ta b l e o f C o n t e n t s
Important Safety Instructions 1-2 Operating Your Raised Vent 3 Care and Cleaning 4-5 Before You Call for Service 5 Warranty and Service 6 Notes 7-8
Part No. 85516 Rev. Use and Care Manual Downdraft Raised Vent
Models: RV30, RV36, RV46
Style varies.
Use & Care Manuals - Page 3
... or operating this manual and the range use and care information.
warning
Hazards...personal injury or death. b) Always turn hood ON when cooking at service panel and ... If you have any other than warranty questions), call:
Dacor Customer Service (800) 793-0093 (U.S.A. Safety Symbols and Labels...:
a) Use this manual can't cover all possible problems and conditions that can occur. When the...
Use & Care Manuals - Page 4
...Dacor Customer Service Team for commercial use.
• This raised vent must be installed by a qualified installer according to the accompanying installation instructions. Never allow acids (citrus juices, tomato sauces, etc.) to remain on top of the vent top cap...in the area around the range.
• Make sure ...• Do not install, repair or replace any part of this manual. BE CAREFUL...
Use & Care Manuals - Page 5
...the vent intake and activate the blower whenever using the cooktop or range.
• Eliminate air currents in the vent vicinity by shutting ...CLEAN FILTER
DELAY OFF
MEDIUM
UP / DOWN
OFF
LOW
HIGH
Top cap
Control panel
Intake grill
Parts the of the vent intake cannot ... key while the raised vent is on the rear burners whenever possible, as the vent intake is in the fully lowered or fully...
Use & Care Manuals - Page 6
... Do not use abrasive cleaners or scrubbers on stainless steel surfaces.
• To avoid damage to clean...of cooking.
Align the left shown)
Top cap Rear intake panel Grasp filter and lift Front... key indicator light will damage the anodized aluminum finish. Vertical grill guide (left and ...8226; To avoid personal injury, turn off the range and vent and make sure all surrounding surfaces are...
Similar Questions
How Do I Replace The Trim Ring Around The Lightbulb On A Dacor Ivsr1 Range Hood?
(Posted by glenrobertson 3 years ago)
Light Bulbs
Where Can I Buy The Lightbulbs That Go In A Dacor Range Hood Eh/ehr3612
Where Can I Buy The Lightbulbs That Go In A Dacor Range Hood Eh/ehr3612
(Posted by ltiessen4 8 years ago)
Need To Replace Worn Out Control Switches That Are On Top Right Side Of My Dacor
(Posted by dhwilkie 9 years ago)
Dacor Rv36 Does Not Rise, Controls Ineffective
My Dacor RV36 downdraft exhaust fan has operated well for quite a few years, but recently it stopped...
My Dacor RV36 downdraft exhaust fan has operated well for quite a few years, but recently it stopped...
(Posted by bertrandkan 10 years ago)
Oven Temperature
Oven temperature will not reach selected temperature one time and maybe the next will exceed the sel...
Oven temperature will not reach selected temperature one time and maybe the next will exceed the sel...
(Posted by goodeg1920 12 years ago)