Get support for Dell PowerEdge 2900

Dell PowerEdge 2900 Support Question

Dell PowerEdge 2900 Support Question

Find answers below for this question about Dell PowerEdge 2900.
Need a Dell PowerEdge 2900 manual? We have 9 online manuals for this item!
Question posted by omso on August 6th, 2014

What Does The First Digit Of The Poweredge 2900 Lcd Message Code Indicate

The person who posted this question about this Dell product did not include a detailed explanation. Please use the "Request More Information" button to the right if more details would help you to answer this question.

Current Answers

Answer #1: Posted by MWatDell on August 18th, 2014 11:39 PM
This answer was accepted by the poster of the original question.
MWatDell

Member since:
November 17th, 2011

Points: 306,490
1,100
points
Hi omso

Basically the E means error whereas W means warning.

Please refer to this manual on Page 19 to have better understanding on these messages:
ftp://ftp.dell.com/Manuals/all-products/esuprt_ser_stor_net/esuprt_poweredge/poweredge-2900_owner%27s%20manual_en-us.pdf

Hope this helps.


MW@Dell

Related Dell PowerEdge 2900 Manual Pages

Installing a SATA Optical Drive - Page 3

... peripheral bay and remove the optical drive from the back of the optical drive. 6 PowerEdge 2900 and 1900 systems only: Perform the following steps. Installing a SATA Optical Drive 3 WARNING... cover. See "Removing a SAS Controller Daughter Card" in your Hardware Owner's Manual. 4 PowerEdge 1950 systems only: Disconnect and remove the SAS controller daughter card. b Remove the center fans...
Installing a SATA Optical Drive - Page 4

... and press the drive down to lock it into the corresponding holes in the same carrier. On PowerEdge 1950 systems, the existing optical drive tray must remove the old drive and interposer card from the tray... the old drive. 1 Pull outward on the left side of the tray. The PowerEdge 2900 and 1900 systems do not reuse the interposer board attached to the optical drive. The pins on the...
Installing a SATA Optical Drive - Page 9

... end to the optical drive and the other to an available power supply cable. 5 Replace the center fan bracket. For a PowerEdge 2900 system, connect to the SATA connector on the system board. For a PowerEdge 1900, use the SATA_B connector. - See "Replacing the Center Fan Bracket" in your Hardware Owner's Manual. 6 Replace the fans...
Installing a SATA Optical Drive - Page 10

... system board 8 Reconnect the cables to the SAS controller daughter card. 9 Close the system. See "Closing the System" in a PowerEdge 2900 or 1900 3 2 4 5 1 1 optical drive 3 SATA data cable 5 SATA power connector on SAS backplane (PowerEdge 2900 only) 2 SATA power cable 4 SATA connector on the system and attached peripherals. 10 Installing a SATA Optical Drive Figure 1-5.
Hardware Owner's Manual (PDF) - Page 18

... signify when the system is being sent or received. The LCD messages refer to indicate an error condition. NIC Indicators 1 2 1 link indicator 2 activity indicator Table 1-5. See your system fails to the network. NIC Indicator Codes Each NIC on the back panel has an indicator that includes a status code followed by descriptive text. The NIC is not connected to boot, press...
Hardware Owner's Manual (PDF) - Page 19

... range. Specified voltage regulator has See "Getting Help" on page 147. failed. Cooling Problems" on page 123. Another fan failure additional scrolling messages. About Your System 19 LCD Status Messages Code Text N/A SYSTEM NAME E1000 E1114 FAILSAFE, Call Support Temp Ambient E1116 Temp Memory E1210 CMOS Batt E1211 ROMB Batt E12nn XX PwrGd E1229...
Hardware Owner's Manual (PDF) - Page 26

... on the screen to the same display entry. See your Product Information Guide for an explanation of range, the LCD displays the fault; The code on the status LCD, locate the code in socket 1. Either of messages indicating multiple voltage faults, you know that is removed from the electrical outlet; when the temperature returns to determine...
Information Update - Page 1

Dell™ PowerEdge2900 Systems Information Update
Information Update - Page 3

Contents PowerEdge 2900 III - Safeguarding Encrypted Data 9 System Message Update 10 LCD Status Messages Update 14 System Setup Program Update 19 Memory Screen 19 CPU Information ... Security Features 5 Optional Internal USB Memory Key 6 Installing the Optional Internal USB Memory Key 7 Processor Upgrades - PowerEdge 2900 II and PowerEdge 2900 III Systems 9 System Board Replacement -
Information Update - Page 5

...-only procedure) PowerEdge 2900 III - New System Features New Performance Features • Two dual-core or quad-core Intel® Xeon® processors. safeguarding encrypted data • System message update for PowerEdge 2900 III system • LCD status message update for PowerEdge 2900 III systems • System Setup program update for PowerEdge 2900 II and PowerEdge 2900 III systems...
Information Update - Page 6

... with a USB flash memory key (see Figure 1-1). Internal USB Connector Location 1 2 1 system board 2 internal USB connector location 6 Information Update Optional Internal USB Memory Key The PowerEdge 2900 III system provides an internal USB connector located on page 20. See "Integrated Devices Screen" on the system board for use the internal USB connector...
Information Update - Page 9

... chassis is upgradeable to create a recovery key during system setup. Information Update 9 PowerEdge 2900 II and PowerEdge 2900 III Systems • If the front of your system chassis is labeled with a... the front of your system is labeled with an encryption program, you are using Windows Server® 2008, you can use encryption programs, such as the BitLocker utility, to store...
Information Update - Page 10

... Remote Access Controller initialization failure Ensure that node interleaving cannot be available... System Messages Message Causes Corrective Actions Alert! slot. 10 Information Update The memory configuration does not...discharge Table 1-1. Check other system messages for additional information for the PowerEdge 2900 III system and the probable cause and corrective action if the...
Information Update - Page 14

.... 14 Information Update Write fault Write fault on the PowerEdge 2900 III system and the probable cause for each message. The system runs but with reduced functionality. The LCD messages refer to the LCD status messages that the memory modules are installed in the Hardware Owner's Manual. LCD Status Messages Update Table 1-2 lists updates to events recorded in the...
Information Update - Page 15

.... Reseat the RAID battery connector. Information Update 15 The SYSTEM NAME displays under the following conditions: • The system is out of acceptable range. LCD Status Messages Code N/A E1000 E1118 E1211 E1625 Text Causes Corrective Actions SYSTEM NAME A 62-character string that can change the system ID and name in the Hardware Owner...
Information Update - Page 18

.... many errors. "# & #" represents the DIMM pair implicated by Information only. The highest priority messages supersede any group of messages with a blue or amber background.) The video is turned off in ## (LCD lights with a lower priority. 18 Information Update LCD Status Messages (continued) Code E2111 E2112 I1915 I1916 Text Causes Corrective Actions SBE Log The system BIOS...
Information Update - Page 21

... stores the pre-boot measurements (compliant with Trusted Computing Group standards) to Off (default), presence of the TPM remains unchanged (all user settings for the PowerEdge 2900 III system.
Information Update - Page 23

SATA Optical Drive Support on RHEL3 and SLES9 SATA optical drives are supported on the Server OS Install tab. Incorrect Processor Information • If an Intel Xeon 54xx processor is installed...System Build and Update Utility, Microsoft® Windows® 2000 is supported by the PowerEdge 2900 and 2900 II systems, but not by the PowerEdge 2900 III system. RHEL - Information Update 23
Information Update - Page 46

System Security 表 1-6 PowerEdge 2900 III TPM。 TPM Security (TPM TPM。 表 1-6. 新的 System Security 选项 说明 TPM Security TPM (TPM Off [ 关 ]&#...
Information Update - Page 48

Microsoft Windows 2000 System Build and Update Utility Microsoft® Windows® 2000 将位于 Server OS Install PowerEdge 29002900 II PowerEdge 2900 III Customize Log output file pathname USB 1-3 48 信息更新

Similar Questions

Ask a New Question
Use the box below to post a new question about this Dell product .
Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

Dell Manuals

Find free Dell PowerEdge 2900 manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Dell Reviews

View thousands of Dell user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete Dell customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed Dell customer service rankings, employee comments and much more from our sister site.

Dell Recalls

Find comprehensive Dell recall information updated hourly on RecallOwl.com.