Question posted by lxblack on September 9th, 2014

Battery

we have a 1550B megohmmeter but the battery does not hold a charge, how can we get a new battery for it

Current Answers

Answer #1: Posted by Brainerd on November 5th, 2014 11:45 PM
This answer was accepted by the poster of the original question.
Brainerd

Member since:
May 24th, 2014

Points: 759,620
1,090
points


I hope this helps you!
Please press accept to reward my effort or post again with more details if not satisfied.
Regards, Brainerd

Related Fluke 1550B Manual Pages

Fluke 1550B MegOhmMeter Datasheet - Page 1

...accessories • Includes heavy-duty leads, probes and alligator clips • Two-year warranty Measurement storage and PC interface soft- age is present and gives the voltage reading up to 5000 Volts Technical Data The Fluke 1550B is a digital megohmmeter... later • High-capacity rechargeable batteries • Includes Quicklink 1550B Software and Optical Interface cable for ...
Fluke 1550B MegOhmMeter Datasheet - Page 2

...accessories Test leads and low leakage probes Alligator clips Interface adapter and cable Quicklink 1550B PC software Line cord Soft carrying case with waterproof bottom User's manual CD with battery... 20 % Short circuit current Bar graph range Insulation test voltage accuracy Induced ac mains current rejection Charging rate for one year after calibration at 50 °C 0 to 2000 meters IP-40 MIL...
FE 1550B Users Manual - Page 1

All rights reserved. All product names are trademarks of their respective companies. ® 1550B MegOhmMeter Users Manual PN 3001289 August 2003, Rev. 1, 6/05 © 2003, 2005 Fluke Corporation.
FE 1550B Users Manual - Page 4

1550B Users Manual ii
FE 1550B Users Manual - Page 5

...9 7. Symbols 4 2. Pushbuttons 5 3. Power Supply Connections 7 5. Connecting to the Circuit Under Test 10 9. Improved Guard Terminal Connection 9 8. Standard Items Provided 2 2. Display Features 6 4. IR Port on 1550B MegOhmMeter 18 iii List of Figures Figure Title Page 1. List of Replacable Parts 21 3. 1550B Accessories 21 List of Tables Table Title Page 1.
FE 1550B Users Manual - Page 6

1550B Users Manual Cover Terminals Display (LCD) Pushbuttons Safety Shutter IR Port PIRODRAT UP FUNCTION OONF/F SCROLL DOWN ENTER TEST Latch Handle Fluke 1550B MegOhmMeter asw16F.EPS iv
FE 1550B Users Manual - Page 7

... EN 61557 Parts 1 and 2; Register your Meter at : www.fluke.com. 1550B MegOhmMeter Introduction The Fluke 1550B MegOhmMeter (hereafter "the Meter") is designed to get the location of the nearest Fluke ... results with user settable ID tag ⇒ Breakdown voltage indication ⇒ Rechargeable lead-acid battery ⇒ Auto shutoff after 30 minutes of inactivity ⇒ Infrared (IR) port for ...
FE 1550B Users Manual - Page 8

... F Infrared Adapter with the items shown in Figure 1. The supplied test leads are for use with this instrument only. Do not use with other equipment 2 1550B Users Manual Unpacking the Meter The Meter comes with interface cable G CD containing Users Manual H CD containing FlukeView Forms Basic I Software License Agreement J Registration Card...
FE 1550B Users Manual - Page 10

... and Off To turn the Meter on and off the Meter. 4 Press O again to turn on the Meter and in the manual are explained Table 1. 1550B Users Manual Symbols Symbols on the Meter. Table 1. s TUV GS ) W X This product complies with voltages higher than 660 V. Symbols P Conforms to turn off : 1. Press O to...
FE 1550B Users Manual - Page 12

...G H I J ASW03F.EPS Description Interference present. Displayed readings may be outside the specified accuracy range. 1550B Users Manual Understanding the Display Display annunciators are shown and described in Ramp mode. Ramp mode indicator. If..., disconnect test leads and remove power from the Meter before charging the battery. 6 Voltage sourced by the Meter or from the circuit ...
FE 1550B Users Manual - Page 13

... information. When the Meter is possible. 7 Fully charging the battery typically takes 12 hours. Disconnect the test leads from the Meter. 3. Figure 4 shows how to connect the Meter to an AC power supply. MegOhmMeter Operating the Meter = Pb Note This Meter uses a rechargeable 12 V a lead-acid battery for AC charger input specifications. 6. Connect the...
FE 1550B Users Manual - Page 14

... used , connecting the positive (+) and negative (−) terminals on the Meter to prevent surface leakage or other unwanted leakage currents from one of the cable. 1550B Users Manual Using the Guard Terminal Note Insulation resistance is left unconnected. For most tests, only two test leads are used to the circuit under...
FE 1550B Users Manual - Page 16

...test. Rotate the safety shutter to the Circuit Under Test ASW09F.EPS Note The 1550B is normal for this meter's input circuitry configuration and does not affect readings that...FUNCTION OONF/F SCROLL DOWN ENTER TEST Figure 8. This is NOT specified below 200 kΩ. 1550B Users Manual Making Measurements Connecting to the Circuit Under Test XW Warning To avoid possible electric ...
FE 1550B Users Manual - Page 18

... pre-set test voltage options (250 V, 500 V, 1000 V, 2500 V, and 5000 V). TV=xxxxV appears flashing in between the pre-set test voltages proceed as follows: 1. 1550B Users Manual Programming a Test Voltage To set a test voltage in the lower-left of the display. 3.
FE 1550B Users Manual - Page 20

... measures and stores dielectric absorption ratio (DAR), when appropriate. When an insulation test is 1 minute or more the polarization test is included in the results. 1550B Users Manual Polarization Index (PI) As part of potentially dangerous voltages to the circuit under test and discharge circuit capacitance before you make connection to...
FE 1550B Users Manual - Page 24

.... 5. Press R to view the stored test data for use FlukeView Forms software to download stored test data. An infrared adapter is supplied with the Fluke 1550B MegOhmMeter for a specific test. Test data appears on the alphanumeric text display and on your stored test data to install FlukeView Forms Basic software on the...
FE 1550B Users Manual - Page 25

... Meter can be installed on it to change the COM port setting to access the DELETE? Double-click on your Windows PC. Turn the 1550B MegOhmMeter on the Fluke 1550B. Follow the instructions for details. See the FlukeView Forms Users Manual file for transferring data from the PC using the FlukeView Forms Basic...
FE 1550B Users Manual - Page 27

... Cable Assembly Users Manual CD English Users Manual Quick Reference Card Table 3. 1550B Accessories Accessories Extended Test Lead Set, 25 feet (7.6 meters) Part No. 1642584 1642591...AC Power Cord (S. Table 3 Identifies the Accessories available for the Meter. Red Test Clip - MegOhmMeter Maintaining the Meter Replaceable Parts and Accessories Table 2 lists the replaceable parts that are ...
FE 1550B Users Manual - Page 28

1550B Users Manual Specifications General Specifications Display Power Charger Input (AC) Dimensions (H x W x L) Weight Temperature (operating) Temperature (storage) Humidity Altitude Enclosure Sealing Input Overload Protection Electromagnetic Compatibility Certifications Safety Compliance Typical Battery Charge Capability Note At temperature extremes, the battery needs to 50 % at 50 oC 2000 m...
Quick Reference Guide - Page 1

.... Printed in USA Visit Fluke's website @ www.fluke.com l Lisez le mode d'emploi du 1550B avant d'utiliser le testeur. l Lue 1550B-käyttöopas ennen tämän testerin käyttöä. 1550B MegOhmMeter Quick Reference Guide Warning l Read the 1550B Users Manual before using the tester. l Man bør læse brugsanvisningen til modelserie...

Similar Questions

No Power After Battery Change
I left my meter on volts and it sat for about 6 months when I went to use it the batteries were obvi...
(Posted by Ragius 8 months ago)
1550b 2016 Model
Wouldn't charge, so I replaced the battery with a correct new one. Let it properly charge and now th...
(Posted by brianrobcox3 1 year ago)
Fluke 1550b Error Code
my fluke 1550b has a error code 2 on the screen it has been dead for 2 years just charged it up.. no...
(Posted by Anonymous-163687 6 years ago)
Works Fine With Battery But Cannot Charge The Battery By Power Supply
If the battery is charged full it works fine. the problem is we cannot chrge the battery from the po...
(Posted by rahimm 7 years ago)
Suitable Replacement Battery For My Fluke 744
I have the old Fluke BP7217 ni-cad battery. What is an acceptable replacement batttery for my Fluke ...
(Posted by cwoodard 8 years ago)
Ask a New Question
Use the box below to post a new question about this Fluke product .
Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

Fluke Manuals

Find free Fluke 1550B manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Fluke Reviews

View thousands of Fluke user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete Fluke customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed Fluke customer service rankings, employee comments and much more from our sister site.

Fluke Recalls