Fluke 1623-2 Not Powering Up/turning On

I have a fluke 1623-2 and although not store bought, appears to have never been used. With new batteries the device will not turn on. I'm getting 9.1DC from the battery pack and continuity from the pins on both sides of the cover. The fuse is good. I have to be overlooking some detail. If anyone can help I would appreciate it

Current Answers

There are currently no answers that have been posted for this question.
Be the first to post an answer!

Remember that you can earn up to 1,100 points for every answer you submit. The better the quality of your answer, the better chance it has to be accepted.

Related Fluke 1623 Manual Pages

Fluke 1623 and 1625 Geo Earth Ground Testers Datasheet - Page 2

... Hz), measurement inhibited for battery door according to EN60529 Protection by using 2 clamps only) The testers are distinctive earth ground testers that can be used even with special symbols, digit height 25 mm, fluorescent backlight Instant measurement through TURN and START one button concept. The most complete testers The Fluke 1623 and 1625 are also easy...
Fluke 1623 and 1625 Geo Earth Ground Testers Datasheet - Page 3

... error indicator Automatic range selection Max. 100 k7 Max. 100 k7 Measurement is not performed if the current through the current clamp is too low 3 Fluke Corporation 1623 and 1625 GEO Earth Ground Testers RA 3-pole ground resistance measurement (IEC 1557-5) Switch position Resolution Measuring range RA 3-pole 0.001 7 to 10 7 0.001...
Fluke 1623 and 1625 Geo Earth Ground Testers Datasheet - Page 4

.... 100 k7 Measurement is not performed if the current through the current clamp is only valid when used in closed loops using two current transformers Measuring voltage Vm = 48 V ac (primary) Measuring frequency 128 Hz (125 ... Stakeless measurement of RS, and RH with the recommended current clamps at the minimum distance specified. 4 Fluke Corporation 1623 and 1625 GEO Earth Ground Testers
Fluke 1623 and 1625 Geo Earth Ground Testers Datasheet - Page 5

... its output voltage directly from the distribution system. 5 Fluke Corporation 1623 and 1625 GEO Earth Ground Testers The rms value of the series interference voltage shall be used over the full Working temperature range by using the temperature coefficient to 140° F) Note: The chart of use. and 4-pole with dc 4 digit (2999 Digit) - 7 segment...
Fluke 1623 and 1625 Geo Earth Ground Testers Datasheet - Page 6

... (5 % of rdg + 5 digit) Measuring sequence Internal resistance Max. accessories and batteries in carrying case NORYL, shock -and scratch proof thermoplast Measurement of interference ...Fluke Corporation 1623 and 1625 GEO Earth Ground Testers Limits of error Climate class Type of protection Max voltage EMC (Emission Immunity) Quality standard External field influence Auxiliary power Battery...
FE 1623 Users Manual - Page 10

...been exposed to Figure 1 and Table 1 for a complete list of the device and possess a formal qualification required for such activities. been dropped from some ...measurements in progress no earth stake must be touched! no separation Refer to unfavourable conditions (e.g. Fluke 1623 Users Manual It can be assumed that safe operation is in different installations (e.g. high voltage pylons...
FE 1623 Users Manual - Page 11

... Item Description A Rotary switch for 6 alcaline batteries (type AA, LR6) or NiCd J batteries (bottom side of measurement functions and ON/OFF. B START button for starting the selected measurement function. C Liquid crystal display (LCD). Features and Functions edv001.eps Table 1. Earth/Ground Tester Safety Regulations 2 1 11 3 FLUKE 1623 max 50 V P2 S 4 5 6 P1 ES 7 plus...
FE 1623 Users Manual - Page 12

Fluke 1623 Users Manual Accessories The following standard accessories were shipped with your Tester: • 6 alkaline AA - type (LR6) batteries • 2 measuring leads 1,5 m • 1 connector cable (for RA 2-pole measurements) • 2 alligator clips • 1 Users Manual Carrying Case The part number for the carrying case for the 1623 Earth/Ground Tester and accessories such as the ...
FE 1623 Users Manual - Page 13

...) with shielded cable set Shielded Cable (Used w/EI-162X Clamp) Clip-on Current Transformer (inducing) 12.7 Inch (320mm) Spilt Core Transformer Earth Stake Cable Reel w/25m Wire Cable Reel w/50m Wire 1623 Users Manual Item/Part Number Fluke-1623 Fluke-1623 Kit Fluke-162x-7001 ES-162P3 ES-162P4 EI-1623 EI-162X 2630254 EI-162AC EI-162BN...
FE 1623 Users Manual - Page 14

Insert batteries. Inserting Batteries edv002.eps 6 Disconnect all test leads. 3. Switch off instrument. 2. If you have problems see section "Troubleshooting". Inserting Batteries Refer to Figure 2 and following these steps: 1. Close battery compartment. 1 2 3 4 + Figure 2. Fluke 1623 Users Manual Setup W Warning Please, read carefully the "safety regulations" before powering up the...
FE 1623 Users Manual - Page 17

... cable reels to H/C2 and S/P2 as shown below . For a continuous measurement keep START pressed. The result is kept on the display until a new measurement is started or the rotary switch is in earth/dirt. Display as... to Figure 5. The "active" symbol indicates that a measurement is turned. 1 2 E ES S H FLUKE 1623 Earth/Ground Tester max 50 V P2 S P1 ES/P1 ES E/C1 S/P2 H/C2 plus...
FE 1623 Users Manual - Page 18

..." symbol indicates that measurement is turned. 1 2 E SH max 50 V P2 S plus FLUKE 3 4 active E SH E SH edv005.eps Figure 6. A Select function RA 3-pole A. Refer to be at least 20 m! Connect stakes with Current Clamp procedure is useful for measuring the resistance of different parallel sections of an earth/ground system. Fluke 1623 Users Manual RA 3-pole...
FE 1623 Users Manual - Page 20

...switch is turned. 12 A Select function D Display as shown. Connect the second current clamp using the supplied safety test leads (1.5 m) as shown below. For continuous measurement keep START pressed. B Connect current clamps. Clamp both current clamps around the earth electrode, which will subsequently be measured. D Symbol " " indicates completed measurement. Fluke 1623 Users...
FE 1623 Users Manual - Page 21

Stakeless Ground Loop Measurement edv007.eps 13 1 2 E H FLUKE 1623 max 50 V plus FLUKE Earth/Ground Tester Setup 3 4 active E H E H Figure 8.
FE 1623 Users Manual - Page 22

...sufficient. Use 6 alkaline AA-type (LR6) batteries. Probe S/P2 must be started (see "Technical data" for reliable measurements. However in some environmental 14 Weak batteries If the batteries are..., a reset occurs. Hint: Replace batteries. The measurement is not possible to drive the current necessary for Uext limit). Fluke 1623 Users Manual Troubleshooting Follow the steps in...
FE 1623 Users Manual - Page 23

... using the correct inducing clamp (see "Recommended Accessories")! If the clamps are reliable, if not increase the probe distance. 6 Is the result of the inducing clamp will render incorrect results. Ensure that the recommended minimum distance between the clamps can be regarded as reliable. 1 U ext >Limit 2 E SH H >Limit E ES S H 3 S >Limit 4 E ES S H E SH FLUKE 1623...
FE 1623 Users Manual - Page 24

... type: IP56 for case, IP40 for battery door according to the operating temperature range and is guaranteed for 1 year. the instrument can be used over the full Working temperature range by...TURN and START one button concept. Robust and Waterproof Instrument is designed for tough environmental conditions (rubber protective cover, IP56). Temp. Fluke 1623 Users Manual Specifications Note Fluke...
FE 1623 Users Manual - Page 26

... error Ra 4-pole 0,001 ... 10 Ω 0,001 Ω ... 19,99 kΩ ±(2% rdg + 3 d) ±(5% rdg + 3 d) Measuring principle: Current/voltage measurement Measuring voltage: Um = 48 Vac. Fluke 1623 Users Manual Automatic range selection. Short-circuit current: > 50 mA Measuring frequency: 128 Hz (125 Hz on request) 18 Measurement is not performed if the...
FE 1623 Users Manual - Page 28

...8486;) Automatic range selection The information regarding stakeless ground loop measurements is only valid when used in closed loops using two current transformers Measuring voltage: Um = 48 VAC (primary) Measuring frequency: 128 Hz...recommended current clamps at the minimum distance specified. 20 Fluke 1623 Users Manual D Stakeless ground loop measurement ( ) Switch position Resolution Measuring range Intrinsic ...
FE 1623 Users Manual - Page 30

Fluke 1623 Users Manual 22

Similar Questions

No Power After Battery Change
I left my meter on volts and it sat for about 6 months when I went to use it the batteries were obvi...
(Posted by Ragius 7 months ago)
Do9 Flashes When The Meter Is Turned Off
I have a fluke 381 that when ever the meter is turned off the display flashes DO9. and it does that ...
(Posted by ericksonra 4 years ago)
When Press Power Button Lcd Screen Flash But No Power On,battery Is 100% Charged
When press power button lcd screen flash but no power on,battery is 100% chargeWhat coud be the poss...
(Posted by rubenzip71030 7 years ago)
Ti32 Is Not Displaying The Thermal Image, Only The Visual Image
Hi,Out thermal scanner recently wont display the thermal image, only the visual view. We have tried ...
(Posted by norhasanamba 8 years ago)
Ask a New Question
Use the box below to post a new question about this Fluke product .
Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

Fluke Manuals

Find free Fluke 1623 manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Fluke Reviews

View thousands of Fluke user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete Fluke customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed Fluke customer service rankings, employee comments and much more from our sister site.

Fluke Recalls

Find comprehensive Fluke recall information updated hourly on RecallOwl.com.