Question posted by bennykittoop on August 13th, 2015

Clamp Meter Out Of Accuracy

fluke model 355 out of accuracy showing more

Current Answers

Answer #1: Posted by waelsaidani1 on September 6th, 2015 10:38 AM
This answer was accepted by the poster of the original question.
waelsaidani1

Member since:
May 12th, 2013

Points: 19,501,787
1,100
points
troubleshooting variable speed drives (VSD), the input bandwidth of a meter can become very important toward getting a meaningful reading. Due to the high harmonic content in the signal coming out of a VSD to the motor, a DMM would measure most of the voltage content depending on its input bandwidth. Measuring the voltage output of a VSD is not a common measurement; if you did the reading would be higher. A motor connected to a VSD only responds to the average value of the signal, and to measure that power, the input bandwidth of the meter must be narrower than its DMM counterpart. The Fluke 337 Clamp Meter has been specifically designed for testing and troubleshooting VSDs.

How to make voltage measurements

  1. Select Volts AC (V~) or Volts DC (V ), as desired.
  2. Plug the black test probe into the COM input jack. Plug the red test probe into the V input jack.
  3. Touch the probe tips to the circuit across a load or power source (in parallel to the circuit).
  4. View the reading, being sure to note the unit of measurement.
  5. (Optional) Press the HOLD button to freeze the reading in the display. Now you can remove the meter from the live circuit and then read the display when you are safely clear of the electrical hazard.
By taking a voltage measurement at the circuit breaker and then at the input of the load on that breaker, you can determine the voltage drop that occurs across the wires connecting them. A significant drop in voltage at the load may effect how well the load functions.

Related Fluke 355 Manual Pages

Fluke 353 and 355 Clamp Meter Datasheet - Page 1

...' surge current with accuracy and repeatability • High voltage measurement of 1000 V ac + dc true-rms, 600 V ac, and 1000 V dc allows users to perform multiple tests with only one tool (355 only) • Resistance to 400 kW coupled with the true-rms, Fluke 355/353 Clamp Meters; Fluke 355/353 True-rms 2000 A Clamp Meters Technical Data High current...
Fluke 353 and 355 Clamp Meter Datasheet - Page 2

...) Range 400 Ω 4 kΩ 40 kΩ 400 kΩ Resolution 0.1 Ω 1 Ω 10 Ω 100 Ω Accuracy 1.5 % + 5 digits 1.5 % + 5 digits 1.5 % + 5 digits 1.5 % + 5 digits 2 Fluke Corporation Fluke 355/353 True-rms 2000 A Clamp Meters Range Resolution Accuracy Trigger Level for Hz Filter OFF 4 V 1 mV 3 % rdg + 10 digits 0.050 V 40 V 10 mV 3 % rdg + 5 digits 0.25...
Fluke 353 and 355 Clamp Meter Datasheet - Page 3

... Test Leads, TP2 Test Probes, AC285 Alligator Clips, and users manual Fluke-355 3 Fluke Corporation Fluke 355/353 True-rms 2000 A Clamp Meters Fluke. Continuity beeper (355 only) On at ≤ 30 Ω Off at ≥ 100 Ω Frequency measurement Measurement range Resolution Accuracy - 5.0 Hz to 100 Hz Accuracy - 100.1 Hz to 1 kHz Trigger level General specifications Batteries Battery life...
Fluke 353 & 355 Users Manual - Page 1

All product names are trademarks of their respective companies. Printed in China. ® 353/355 Clamp Meter Users Manual PN 2842223 October 2007 © 2007 Fluke Corporation, All rights reserved.
Fluke 353 & 355 Users Manual - Page 3

Table of Contents Title Page Introduction ...1 Contacting Fluke ...1 Safety Information ...2 Features ...5 Display ...7 Using the Meter ...8 Measuring AC or DC Current 8 Measuring Inrush Current 9 Measuring AC and DC Voltage (355 only 10 Testing Continuity (355 only 12 Measuring Resistance (355 only 13 Maintenance...14 Cleaning the Meter ...14 Changing the Batteries 14 User Replaceable ...
Fluke 353 & 355 Users Manual - Page 9

... rms voltage, and resistance. Register the Meter at : www.fluke.com. The Meter ships with: • TL224 Test leads (355 only) • AC285 Clips (355 only) • TP74 Test Probes (355 only) • Soft carrying case • 6 AA/LR6 Batteries, installed • 353/355 Users Manual (7 languages) Clamp Meter Contacting Fluke To contact Fluke, call one of the following telephone numbers...
Fluke 353 & 355 Users Manual - Page 10

... measuring current, center the conductor in the clamp. Contact with the back cover removed or the case open. • Never remove the back cover or open the case of the Meter- 600 V rms and 1 kHz or ... measurements. 353/355 Users Manual Safety Information XWWarnings: Read First To avoid possible electric shock or personal injury: • Use the Meter only as marked on the Meter, between the ...
Fluke 353 & 355 Users Manual - Page 11

... the common test lead before testing resistance, continuity, or diodes. • Use only 6 AA/LR6 batteries, properly installed in the jaw opening is not visible. Clamp Meter Safety Information • To avoid false readings that can lead to local and national safety codes. Check...
Fluke 353 & 355 Users Manual - Page 12

...removal from the primary supply level, such as an electricity meter or an overhead or underground utility service. Conforms to requirements ...against transients in equipment in large buildings. Go to operation instructions. Canadian Standards Association 4 Refer to Fluke's web site for recycling information. Explanation of Symbols Explanation Risk of this product as distribution panels, ...
Fluke 353 & 355 Users Manual - Page 13

...) Common input terminal. (355 only) Min Max button -When first pressed, the Meter shows maximum input. Inrush button- Range button- Clears last reading from a ASD or VFD motor speed controller. With subsequent presses, the minimum and the average inputs are shown. Features and Buttons Number A B C D E F G H I J K Description Current sensing clamp Rotary function switch Hold button...
Fluke 353 & 355 Users Manual - Page 15

... display M Main display N Hazardous voltage present O Continuity symbol P Inrush mode is active Min, Max, Avg, or Live modes. time reading. The Display 5 6 7 8 9 10 fbq01.eps Clamp Meter Features Table 4. Live mode is E active with Min Max and designates the real- Display Figure 2 and Table 4 explain the display. 1 23 4 16 15 14 MAXMINAVGLIVE...
Fluke 353 & 355 Users Manual - Page 16

.... XWWarning To avoid possible electric shock or personal injury, if current is moving in opposite directions, place only ONE conductor into the clamp at a time. See Figure 3. 600 V 355 AC/DC CLAMP METER Auto Range 2000 A TRUE RMS 600 V CAT A OFF A AC+DC A V V VAC+DC RANGE HOLD ZERO INRUSH Hz MIN MAX FILTER COM...
Fluke 353 & 355 Users Manual - Page 17

... VAC+DC RANGE HOLD ZERO INRUSH Hz MIN MAX FILTER COM V 600 V CAT 1000 V CAT 2A INRUSH 3 355 AC/DC CLAMP METER Auto Range TRUE RMS 2000 A 600 V CAT A OFF A AC+DC A V V VAC+DC RANGE HOLD ZERO... system under test powered down, place the source wire into the Meter jaws. 2. Press E on the Meter. 4. See Figure 4. Measuring Inrush Current Inrush current is surge current that...
Fluke 353 & 355 Users Manual - Page 18

... frequency reading on the display. 5. Turn the rotary function switch to the V terminal. AC Voltage Measurement fbq05.eps See Figures 5 and 6. 10 353 AC/DC CLAMP METER Auto Range 2000 A TRUE RMS 600 V CAT A OFF A AC+DC A V V VAC+DC RANGE HOLD ZERO INRUSH Hz MIN MAX FILTER COM V 600 V CAT 1000 V CAT...
Fluke 353 & 355 Users Manual - Page 19

DC Voltage Measurement fbq06.eps Clamp Meter Using the Meter 11 355 AC/DC CLAMP METER Auto Range 2000 A TRUE RMS 600 V CAT A OFF A AC+DC A V V VAC+DC RANGE HOLD ZERO INRUSH Hz MIN MAX FILTER COM V 600 V CAT 1000 V CAT Figure 6.
Fluke 353 & 355 Users Manual - Page 20

...all capacitors are discharged. If the resistance is open (B) or above 399.9 Ω. See Figure 7. 355 AC/DC CLAMP METER Auto Range 2000 A TRUE RMS 600 V CAT A OFF A AC+DC A V V VAC+DC... RANGE HOLD ZERO INRUSH Hz MIN MAX FILTER COM V 600 V CAT 1000 V CAT 355 AC/DC CLAMP METER Auto Range 2000 A TRUE RMS 600 V CAT A OFF A AC+DC A V V VAC+DC RANGE HOLD ...
Fluke 353 & 355 Users Manual - Page 21

...that dangerous voltages may be present at the input terminals and may not be displayed Clamp Meter Using the Meter 355 AC/DC CLAMP METER Auto Range 2000 A TRUE RMS 600 V CAT A OFF A AC+DC ... the circuit is turned off and all capacitors are discharged. See Figure 8. Measuring Resistance (355 only) XW Warning To avoid possible electric shock or personal injury, when measuring resistance in...
Fluke 353 & 355 Users Manual - Page 22

... Observe correct polarity when installing the batteries. 4. Turn the Meter off and disconnect the test leads. 2. 353/355 Users Manual Maintenance XW Warning To avoid electrical shock, or ... 14 Cleaning the Meter WCaution To avoid damaging the meter, do not touch the circuit board without proper static protection. • If the Meter is not going to Contacting Fluke for more information....
Fluke 353 & 355 Users Manual - Page 23

...1.5 % rdg + 15 digits 1.5 % rdg + 5 digits 1.5 % rdg + 5 digits Current Measurement 100.1 Hz to 1 kHz Range Resolution Accuracy > 10 A 40 A 10 mA 3.5 % rdg + 15 digits 400 A 100 mA 3.5 % rdg + 5 digits 2000 A; 1400 ac rms 1 A 3.5 % rdg + 5 digits Clamp Meter Specifications Trigger Level for Inrush 0.50 A 5.0 A 5 A Trigger Level for Hz Filter OFF 2.50 A 2.5 A 8 A Trigger Level for Hz...
Fluke 353 & 355 Users Manual - Page 25

Continuity Beeper (355) On at ≤ 30 Ω Off at ≥ 100 Ω Frequency Measurement Measurement Range 5.0 Hz to 1 kHz Resolution Accuracy 5.0 to 100 Hz 0.1 Hz (15 Hz to 399.9 Hz) 1 Hz ( 400 Hz to 1 kHz) 0.2 % + 2 counts Accuracy 100.1 Hz to 1 kHz 0.5 % + 5 counts Trigger Level Refer to current and voltage tables Clamp Meter Specifications General Specifications...

Similar Questions

Selector Dial
(Posted by Russellfenstermaker 1 year ago)
Cal Err Message Is Showing While On The Clamp Meter
CAL Err message is showing while power on the clamp meter.No buttons are functioning after this erro...
(Posted by kvramesh 1 year ago)
Pantalla Remota Flete 381
Buenos días donde puedo conseguir la pantalla inalámbrica para la pinza amperica 381
(Posted by delossantos2577 3 years ago)
Calibration Adjustment Procedure For Fluke 355 Clamp Meter
clamp meter readings out specification we need to know how to minimize the error
(Posted by bennykittoop 8 years ago)
Ask a New Question
Use the box below to post a new question about this Fluke product .
Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

Fluke Manuals

Find free Fluke 355 manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Fluke Reviews

View thousands of Fluke user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete Fluke customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed Fluke customer service rankings, employee comments and much more from our sister site.

Fluke Recalls

Find comprehensive Fluke recall information updated hourly on RecallOwl.com.