Get support for Fluke 437-II

Fluke 437-II Support Question

Fluke 437-II Support Question

Find answers below for this question about Fluke 437-II.
Need a Fluke 437-II manual? We have 2 online manuals for this item!
Question posted by elhassanali19 on October 25th, 2015

How Can I Use Fluke 700pd6

The person who posted this question about this Fluke product did not include a detailed explanation. Please use the "Request More Information" button to the right if more details would help you to answer this question.

Current Answers

Answer #1: Posted by TechSupport101 on October 25th, 2015 8:13 AM
This answer was accepted by the poster of the original question.
TechSupport101

Member since:
May 24th, 2013

Points: 12,171,285
1,100
points
Hi. Refer to the Fluke 700 series' Instruction Manual here https://www.pce-instruments.com/slot/2/download/386131/700pdx_iseng0300.pdf

Related Fluke 437-II Manual Pages

Manual - Page 3

... & Limitation of Liability 1-2 Shipment Note 1-3 Contacting a Service Center 1-4 Safety Information: Read First 1-4 Safe Use of Li-ion Battery Pack 1-7 2 About This Manual 2-1 Introduction...2-1 Users Manual Contents 2-1 3 Features of Fluke 434-II/435-II/437-II 3-1 Introduction...3-1 General Measurements 3-1 Measuring modes to investigate details 3-2 Logging of Measuring Values in...
Manual - Page 7

... Note: Survey of items that should be included in your Analyzer Kit. • Contacting a Fluke Service Center. • Safety Information: Read First! • Safe Use of general and important aspects concerning the Fluke 434-II/435-II/437-II Three Phase Energy and Power Quality Analyzer (hereafter referred to as 'Analyzer'). Chapter 1 General Aspects Introduction This chapter informs...
Manual - Page 10

... & UK, EU, China, UK, US, Canada) 3 Hang Strap 4 Alligator Clips. The following international symbols are used on the World Wide Web at : www. .com 1.877.766.5412 Fluke 434-II/435-II/437-II Users Manual # Description 1 Power Quality Analyzer Fluke 43x Series II + Side Strap, Battery Pack BP290 (28 Wh) and 8 GB SD Memory Card Installed 2 Decal Set...
Manual - Page 11

...use. • Always connect the Power Adapter first to the AC outlet before connecting it to the Analyzer. • Do not touch voltages >30 V ac rms, 42 V ac peak, or 60 V dc. • Use...ratings of this product as suitable for the Fluke 434-II/435-II/437-II Analyzer. • Keep fingers behind the finger guards on the probes. • Before use the product around or remove from hazardous ...
Manual - Page 12

... the local line power voltage and frequency (refer to Ground: 42 V peak. Voltage ratings are exposed. • The battery door must be read as V ac rms (50-60 Hz) for AC sinewave applications and as "working voltage". Voltage at : www. .com 1.877.766.5412 Fluke 434-II/435-II/437-II Users Manual • Use only correct...
Manual - Page 14

... charger showing visible damage. • Batteries contain hazardous chemicals that specifically provided for use with this equipment. • Do not use any charger other ). • Never use with water en get medical aid. Fluke 434-II/435-II/437-II Users Manual Recommendations to safe use of the Battery Pack. • The Battery Pack needs to be charged before...
Manual - Page 17

... find certain subjects. On the last pages of measuring functions with the manual pages where they can use the Fluke Fluke 434-II/435-II/437-II Three Phase Energy and Power Quality Analyzers effectively and in this manual may be found. Power Inverter Efficiency (13), 2-1 MyFlukeStore Shop for instance the word 'Transients' to find all measuring modes. Users...
Manual - Page 18

Fluke 434-II/435-II/437-II Users Manual - Power Wave (19), - Cursor and Zoom: how to save, recall and delete screenshots and data formats. Using Memory and ... Shipboard V/A/Hz (22) • Chapter 23. Setting up the Analyzer: a comprehensive explanation of Power Measurement and Energy Loss Calculation, Installing USB Drivers, Instrument Security Procedures (English only). Flicker (17), ...
Manual - Page 19

... connected correctly, use Scope Waveform and Scope Phasor. Note After you have additional features such as Shipboard V/A/Hz and the possibility to measure in 400 Hz power systems, and has a heavy duty Hard Case with a timed start. Fluke 435-II and 437-II have switched on how to facilitate proper signal polarity. In Fluke 434-II the functions...
Manual - Page 20

... to capture voltage anomalies. Frequency is shown by inverters that is recorded in the Trend screen. Fluke 434-II/435-II/437-II Users Manual To get a general impression of the quality of these values over time of a power system use MONITOR. For this press the MENU key. Voltage waveforms must be a sine wave that convert single...
Manual - Page 25

... Analyzer. • To avoid overheating of the Power Adapter to the correct voltage. • Connect the Power Adapter to the ac outlet. • Connect the Power Adapter to the INPUT for long periods, e.g. BATT. Additional to charge it before use check that can be empty and it for Fluke products online at: www. .com 1.877...
Manual - Page 28

... The Function keys F1 ... Highlight RS-232: . Active Function key selections are used to prevent unwanted operation during unattended measurements: ENTER Press for use the menus is illustrated in strong sunlight (when powered by battery). How to Factory Defaults. Fluke 434-II/435-II/437-II Users Manual Display Brightness Press repeatedly to the next higher menu SETUP...
Manual - Page 32

... all measurements except Monitor (Ch. 16) and Power Wave (Ch. 19). 2 Trend screen: this type of a Bar Graph. Used for all measurements. 3 Waveform screen: shows voltage and current waveforms as a percentage by means of screen is related to a Meter screen. Used for a certain phase - Fluke 434-II/435-II/437-II Users Manual Phase Colors Measuring results belonging...
Manual - Page 34

Nominal line voltage and frequency: are indicated in gray. Fluke 434-II/435-II/437-II Users Manual E Status line: following information appears on the screen. Active Function key selections are indicated in Chapter 20 - Time of Analyzer's real time clock. Number of the limits used for the measurement. F Softkey text area: softkey functions that can be...
Manual - Page 59

... SETUP key, F4 - FUNCTION PREF and the up/down arrow keys to measure real power (kW), apparent power (kVA), reactive power (kvar), harmonic power components ( kVA Harm), and unbalance power (kVA Unb). Unified uses algoritms according to IEEE 1149 as described in Fluke 437-II) for Fundamental and Full. The method can be changed via the Function Preference menu...
Manual - Page 60

...-II/435-II/437-II Users Manual Meter screen To access the Power & Energy Meter screen: c MENU d e ENTER The following power measurements are displayed. Real power (W, kW): measurement as normally registered by phase and in total. 11-2 MyFlukeStore Shop for Fluke products online at: www. .com 1.877.766.5412 Fundamental real power (W or kW fund): the fundamental frequency is used...
Manual - Page 158

... that utilizes the arithmetic method for system power as described in the wiring. Fluke 434-II/435-II/437-II Users Manual Displacement Power Factor (DPF) and Cos ϕ Displacement power factor is used behind the power parameters e.g. Displacement Power Factor: PF1X = P1X S1X System Displacement Power Factor Υ and Δ: PF1 = P1+ S1+ Power & Energy Losses Energy Loss has 2 main...
Manual - Page 159

... A-7 MyFlukeStore Shop for Fluke products online at 50/60 Hz N - is used to indicate phase A, B, C (or L1, L2, L3) Υ - is used for rms current calculated form samples over a 10/12 cycle window I - Time window of samples in formulas: P - is used for unbalance power PF - Power Factor DPF - superscript + is used for apparent power VA Q - first sample...
Datasheet - Page 2

... Fluke Power Quality tools enable the user to monitor and target energy usage to product waste. Fluke's Power Quality tools provide the means to identify potential power quality issues. Power...and grounding, and overloaded circuits or harmonics are not being used effectively. The increasing cost of poor power quality II Power Quality and Energy Analyz- Some problems are terms of ...
Datasheet - Page 6

Troubleshooters Loggers Fluke 345 Power Quality Clamp Meter Fluke 43B Power Quality Analyzer Fluke 430 Series II Three-Phase Power Quality and Energy Analyzers Fluke VR1710 Power Quality Recorder Monitor electronic loads. Power quality parameters including rms average, transients, flicker, and harmonics up to the 32nd, are recorded using a user-selected average period from 3 to 300 ...

Similar Questions

Схема Fluke 434?
(Posted by Unshikov 6 months ago)
Fluke 1735 Stuck On Main Page
Hello, my Fluke 1735 is stuck on the main boot up page and will not register anything when the dial ...
(Posted by electricians 2 years ago)
1735 Powers On Then Locks Up On Main Screen -
replaced battery. charged OKpower up unit - shows main screen. locks up on main screen none of the p...
(Posted by russellsaunders 2 years ago)
Power Cord
where can i get a power cord for the fluke 1735 power logger.
(Posted by clint9521 3 years ago)
Fluke 1735 Power Logger Current Measurement
In an induction generator experimental set up, I tried to measure power. But the current display was...
(Posted by ajibadeoa 10 years ago)
Ask a New Question
Use the box below to post a new question about this Fluke product .
Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

Fluke Manuals

Find free Fluke 437-II manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Fluke Reviews

View thousands of Fluke user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete Fluke customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed Fluke customer service rankings, employee comments and much more from our sister site.

Fluke Recalls

Find comprehensive Fluke recall information updated hourly on RecallOwl.com.