Manual - Page 10

... are used on the World Wide Web at : www. .com 1.877.766.5412 Set of 5 5 Test Leads, 2.5 m + Color Coding Clips. Fluke 434-II/435-II/437-II Users Manual # Description 1 Power Quality Analyzer Fluke 43x Series II + Side Strap, Battery Pack BP290 (28 Wh) and 8 GB SD Memory Card Installed 2 Decal Set for PC Connection (USB-A to the user. A Warning identifies conditions and actions that...
Manual - Page 19

... time the U (Unstable) symbol shows in a logical order. If not installed, they show up in the menu in grey color. Chapter 3 Features of Fluke 434-II/435-II/437-II Introduction The Analyzer offers an extensive and powerful set of measurements to perform measurements in the screen header. In Fluke 434-II the functions Flicker, Transients, Power Wave and Mains Signaling can be...
Manual - Page 59

... to use for power calculations; VA∑. 11-1 MyFlukeStore Shop for Fluke products online at the fundamental frequency (60, 50 Hz, or 400 Hz in Fluke 437-II) for rms based measurements. The related Trend screen shows the changes over time of use the Unified method to chapter 24 for the Fluke 430 series II instruments is also...
Manual - Page 79

... is used. When selecting timed start of the measurement. Note: Monitor is not available for Fluke products online at: www. .com 1.877.766.5412 Flicker 4. Timed start in Fluke 437-II. 16-1 MyFlukeStore Shop for measurements in 400 Hz power systems such as offered in combination with the 10 minute real time clock is started...
Manual - Page 87

... measurements in 400 Hz power systems such as offered in the Meter screen. It quantifies the luminance fluctuation of the human eye / brain sensory system. The algorithm behind the measurement meets EN61000-4-15 and is based on a perceptual model of lamps caused by the parameters shown in Fluke 435-II and 437-II. A high flicker reading means...
Manual - Page 95

... available in Fluke 435-II and 437-II the Analyzer functions as offered in a single shot acquisition. Power Wave Screen To access the Power Wave screen: c MENU d F2 19-1 MyFlukeStore Shop for Voltage, Amps, Watts). The function records half cycle rms values on 8 channels, frequency and instantaneous power (Vrms½, Arms½, W, Hz and scope waveforms for Fluke products online...
Manual - Page 99

... 2 is set from HOLD to RUN. The frequency range is 70.0 - 3000.0 Hz for 60 Hz systems and 60.0 - 2500.0 Hz for Fluke products online ...435-II and 437-II can capture the occurrence (signal level) of the nominal line voltage. Power distribution systems often carry control signals to switch appliances on and off remotely (also known as offered in Fluke 435-II and 437-II. MANUAL SETUP...
Manual - Page 107

.... Events such as dips and swells are useful for Fluke products online at: www. .com 1.877.766.5412 The function is available in the Fluke 437-II and provides measuring functions that are listed in the Meter screen. Meter screen To access the Shipboard V/A/Hz Meter screen: c MENU d F2 e 22-1 MyFlukeStore Shop for shipboard installations.
Manual - Page 121

... key F5 - Use the up the Analyzer MANUAL SETUP 1 Press the SETUP key and next Function key F4 - Press ENTER to the power system. MANUAL SETUP to reach the MANUAL SETUP screen. 2 Use the up/down arrow keys to select the Nominal Frequency. Sensitivity x10 increases amps sensitivity by -step example on in Fluke 437-II also 400 Hz). Date, Time: use...
Manual - Page 136

...437-II Users Manual Installation of 1 year is recommended. To order replacement parts or additional accessories, contact your authorized Fluke Service Center if the calibration interval has been expired. Item Ordering Code Power Adapter Rechargeable Li-ion battery 28 Wh Test Lead Set 2.5 m incl. Flexible 6000 A AC Current Clamp Set (4 pieces). INSTALL OPTION. For this Analyzer...
Manual - Page 139

... without tolerances are based on the results of an average instrument excluding accessories. Chapter 27 Specifications Introduction Models Concerned Fluke 434-II: Energy Analyzer Fluke 435-II: Power Quality and Energy Analyzer Fluke 437-II: Power Quality and Energy Analyzer 400 Hz. This manual contains information and warnings that must be followed by the user to ensure safe operation and...
Manual - Page 142

...435-II/437-II Users Manual MEASUREMENT MODES Scope Volts/Amps/Hertz Dips and Swells Harmonics DC, 1 ... 50 Power and Energy Energy Loss Calculator Inverter Efficiency Unbalance Inrush Monitor Flicker Transients Mains Signaling Power Wave Logger Shipboard V/A/Hz 4 voltage waveforms, 4 current waveforms, Vrms, Vfund. All parameters are measured sumultaneously in Fluke 434-II. Note: not supported...
Manual - Page 143

...5...2000 A 0.5...200 A (ac only) Hz2 Fluke 435-II /437-II @ 50 Hz nominal Fluke 435-II /437-II @ 60 Hz nominal Fluke 437-II @ 400 Hz nominal 42.5 ... 57.5 Hz 51 ... 69 Hz 340 ... 460 Hz 1 V 0.1 V 0.1 V 0.1 V 0.1 V 0.01 1 A 0,1 A 1 A 0.1 A 1 Arms 1 Arms 0.01 1 A 0,1 A 1 A 0.1 A 1 A 0,1 A 1 A 0.1 A 0.001 Hz 0.001 Hz 0.1 Hz 27 Specifications Electrical Measurements Accuracy ± 0.1% of nominal...
Manual - Page 166

... the instrument. Fluke 434-II/435-II/437-II Users Manual Installing the USB Drivers To install the USB drivers, do the following window, click "Next" to install the software automatically. If you have not yet been installed, Windows will open. B-2 MyFlukeStore Shop for the Fluke 430 series II instrument have internet access at : www. .com 1.877.766.5412 Depending on your PC settings and...
Manual - Page 169

...: the instrument's embedded software and calibration data. SN74V235-7PAG, contains: data to be exchanged between DSP and Microcontroller. 5. SD Memory Card. Appendix C Instrument Security Procedures Introduction Model Numbers: Fluke 434-II, Fluke 435-II, Fluke 437-II Short Description: 3-Phase Energy & Power Quality Analyzer Memory. Fluke 43x-II has the following memory devices: 1. RAM...

Fluke 437-II Reviews

Do you have an experience with the Fluke 437-II that you would like to share?
Earn 750 points for your review!
We have not received any reviews for Fluke yet.

Popular Fluke 437-II Search Terms

The following terms are frequently used to search for Fluke 437-II support:

Ask a New Question
Use the box below to post a new question about Fluke 437-II.
Manuals / Documents
Download any of our Fluke 437-II manuals for free!

We have the following 2 documents available for the Fluke 437-II:
  • Manual
  • Datasheet

Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

Fluke Manuals

Find free Fluke 437-II manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Fluke Reviews

View thousands of Fluke 437-II user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete Fluke customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed Fluke customer service rankings, employee comments and much more from our sister site.

Fluke Recalls

Find comprehensive Fluke recall information updated hourly on RecallOwl.com.