Get support for Zenith ZW5010

Zenith ZW5010 Support Question

Zenith ZW5010 Support Question

Find answers below for this question about Zenith ZW5010.
Need a Zenith ZW5010 manual? We have 1 online manual for this item!
Question posted by johanneshoffman on June 30th, 2012

Leaking Air Conditionar

My two-year old window air conditioner just started leaking condensate water into the house.  What would cause this?  how can i fix it?

Current Answers

There are currently no answers that have been posted for this question.
Be the first to post an answer!

Remember that you can earn up to 1,100 points for every answer you submit. The better the quality of your answer, the better chance it has to be accepted.

Related Zenith ZW5010 Manual Pages

Owners Manual - Page 2

...of Controls 16 Additional Features 17 Air Direction 17 Drain Pipe 17 Removal from Window 17 Maintenance and Service 18 Air Filter 18 Cleaning the Air Conditioner .....18 How to Remove the... this unit. Dealer's Name Date Purchased s Staple your air conditioner. You'll find many answers to prove date of troubleshooting tips. Just a little preventive care on how to use by young ...
Owners Manual - Page 3

... indicates the possibility of the product, it is classified by the following instructions must be followed. Do not disassemble or modify products. • It may cause fire and electric shock. WARNING s Installation Always install the expansion panel(s). The seriousness is recommended that you have a helper to follow the instruction.
Owners Manual - Page 4

... or pulling out the power plug. • It will cause electric shock or • No grounding may cause electric shock. Always plug into a grounded outlet. • It will cause electric shock or fire. Do not operate with other appliances. shock. 4 Room Air Conditioner electric shock. Use the air conditioner on a single outlet circuit. (See page 7.) Do not...
Owners Manual - Page 5

Do not operate the air conditioner if you smell gas. • It may cause an electric shock. It may cause explosion, fire, and burn. Leaving it must be operated in the air conditioner falling out of the window, creating a safety hazard. Do not clean the air conditioner with water. • Water may cause failure of machine. Ensure that the outer case is not...
Owners Manual - Page 7

...and maintenance, contact an Authorized Service Center. Do not use water to your model number and serial number available. Do not start/stop operation by plugging/unplugging the power cord. 5. Do not... food, pets, plants, and art objects). They should be hazardous to clean inside the air conditioner. Do not use this manual. See the warranty page for an extended period of time could...
Owners Manual - Page 8

Features WARNING: This appliance should be installed in this Manual This symbol alerts you to hazards that could cause harm to the risk of electric shock. This symbol alerts you to the air conditioner. Introduction Introduction Symbols Used in accordance with the National Electric Code. NOTICE This symbol indicates special notes. KNOB ROCKER SWITCHS...
Owners Manual - Page 9

...of potential safety hazards, we strongly discourage the use of an extension cord. ELECTRICAL SAFETY IMPORTANT GROUNDING INSTRUCTIONS Air conditioner has a three-prong grounding plug on its power supply cord, which must be plugged into properly grounded ... cord may pose special problems. Consult a qualified electrician. NOTICE Aluminum house wiring may include a current interrupter device.
Owners Manual - Page 10

... shock, use the plug with a three-prong grounding plug. If the power outlet does not include a grounding slot, have any doubt whether the air conditioner is grounded through the house wiring. WARNING: Changing the outlet without making the appropriate wiring changes will create an unsafe condition that could result in fire or electrical...
Owners Manual - Page 13

... Sill Indoors Outer Sill Outdoors Wood Strip Mounted on Top of Inner Sill is more than the storm window frame (Storm Window Frame) or wood strip (Outdoors) to help condensation to drain properly to the inner window sill across the full width of the sill flush against the back off the inner sill. B. 4. This...
Owners Manual - Page 14

Cut the adhesive-backed seal strip (Type E) to the unit with short side of the air conditioner (Type H),Fasten the curtains to the window width. Locating unit in place. Install the L brackets behind the inner window sill, with screws (Type A). Insert the guide panels(Type G) into the guides of bracket as shown. Attach L bracket 4-1. Be...
Owners Manual - Page 15

..., it will be centered in the back automatically. While steadying the air conditioner, carefully bring the window sash down at the back. NOTICE : When the air conditioner drops into the room. 3-2. CENTER LINE 1-2. ABOUT 1/4" 3. If it into the notches of the air conditioner. Carefully lift the air conditioner and slide it does not, there is lowered to fill the...
Owners Manual - Page 16

...midpoint. Mode/Temp Control Use to set the fan speed to a Cool On setting. 16 Room Air Conditioner Turn the knob toward the cooler area. When set at least 3 minutes before switching back to ...Speed to the Fan Only or the Cool On mode. Fan Speed Use to set the air conditioner to provide air circulation and filtering without cooling. Fan Only Mode Use Fan Only at least 3 minutes before...
Owners Manual - Page 17

... the rear hole of these directions. Lift the air conditioner from the window and remove the sash seal from the sharp fin area to overflow. This air conditioner is then picked up by pushing down and away from the fins to drain ALL condensate from the air conditioner. To drain the water, remove the Drain Cap and secure the...
Owners Manual - Page 18

... cooling capacity and causing an accumulation of the grille away from the front grille by lifting the air filter up. 2....Air Filter Check the air filter at least twice a month to see if cleaning is necessary. To ensure continued peak efficiency, the condenser coils (outside of their slots. 18 Room Air Conditioner Trapped particles in a mild detergent solution. Gently shake the excess water...
Owners Manual - Page 19

... that the air conditioner is a normal operational feature. Close all doors and windows and check for service, please review the following information and try to solve the problem. Check whether the voltage is operating normally when: • You hear a pinging noise. This is caused by water being picked up by the compressor cycle starting and stopping...
Owners Manual - Page 20

... the mode control to a higher number The highest setting provides . See Air Conditioner Freezing Up below. The room may not be operating abnormallywhen: Problem Possible Causes What To Do Air conditioner does not start Air conditioner does not cool as it should Air conditioner freezing up . Check the house fuse/circuit breaker box and replace the fuse or reset the breaker...

Similar Questions

Plug Breaker Wont Stay Reset
My ZW5010 a/c got wet...now breaker on plug keeps tripping, and wont stay reset...help???
(Posted by backyardbob2007 9 years ago)
Weigh
how much does the unit weight?
(Posted by sconcannon 11 years ago)
Keegan Oldham
why dose it leak water?  
(Posted by keegsoccer 11 years ago)
My Fan Motor Keeps Stoping And The Com Presser Heats Up Then Blows The Breaker
the unit is only two years old.
(Posted by ddurec 13 years ago)
Ask a New Question
Use the box below to post a new question about this Zenith product .
Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

Zenith Manuals

Find free Zenith ZW5010 manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Zenith Reviews

View thousands of Zenith user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete Zenith customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed Zenith customer service rankings, employee comments and much more from our sister site.

Zenith Recalls

Find comprehensive Zenith recall information updated hourly on RecallOwl.com.