Command Reference Guide
Page 2
...rights only as translation, transformation, or adaptation) without written permission from 3Com Corporation. 3Com Corporation reserves the right to revise this documentation and to make changes in any software on removable media described in this documentation may be provided to recognized ... in all products are labelled according to the following: All technical data and computer software are unable to locate a copy, please contact 3Com and a copy will be trademarks of 3Com Corporation to : Establishing environmental performance standards that comply with only such rights as ...
...rights only as translation, transformation, or adaptation) without written permission from 3Com Corporation. 3Com Corporation reserves the right to revise this documentation and to make changes in any software on removable media described in this documentation may be provided to recognized ... in all products are labelled according to the following: All technical data and computer software are unable to locate a copy, please contact 3Com and a copy will be trademarks of 3Com Corporation to : Establishing environmental performance standards that comply with only such rights as ...
Command Reference Guide
Page 3
CONTENTS ABOUT THIS GUIDE About This Software Version 19 Organization of the Manual 19 Intended Readership 20 Conventions 20 Related Manuals 21 1 USING SYSTEM ACCESS COMMANDS Logging in Commands 24 authentication-mode ...
CONTENTS ABOUT THIS GUIDE About This Software Version 19 Organization of the Manual 19 Intended Readership 20 Conventions 20 Related Manuals 21 1 USING SYSTEM ACCESS COMMANDS Logging in Commands 24 authentication-mode ...
Command Reference Guide
Page 19
...for configuring Ethernet port and link aggregation. ■ Using VLAN Commands - About This Software Version The software in the Switch 5500G-EI is a subset of your hardware platform, some other 3Com products. CAUTION: Any command that used for configuring STP. ■ Using AAA and...■ Using System Access Commands - If you need to use the configuration commands supported by version 3.0.x software on the 3Com® SuperStack® 4 Switch 5500G-EI. Introduces the commands used for configuring network protocols. ■ Using Routing Protocol Commands - ABOUT THIS GUIDE...
...for configuring Ethernet port and link aggregation. ■ Using VLAN Commands - About This Software Version The software in the Switch 5500G-EI is a subset of your hardware platform, some other 3Com products. CAUTION: Any command that used for configuring STP. ■ Using AAA and...■ Using System Access Commands - If you need to use the configuration commands supported by version 3.0.x software on the 3Com® SuperStack® 4 Switch 5500G-EI. Introduces the commands used for configuring network protocols. ■ Using Routing Protocol Commands - ABOUT THIS GUIDE...
Command Reference Guide
Page 20
... must enter one of a command text. Do not press Return or Enter when an instruction simply says "type." Enter either hardware, or none, or software. Introduces the commands used for example: Press Ctrl+Alt+Del The words "enter" and "type" When you see the word "enter" in the command... flow-control {hardware | none | software}, the braces and the vertical bars combined indicate that alerts you are ready to potential personal injury. You must select and enter one of the...
... must enter one of a command text. Do not press Return or Enter when an instruction simply says "type." Enter either hardware, or none, or software. Introduces the commands used for example: Press Ctrl+Alt+Del The words "enter" and "type" When you see the word "enter" in the command... flow-control {hardware | none | software}, the braces and the vertical bars combined indicate that alerts you are ready to potential personal injury. You must select and enter one of the...
Command Reference Guide
Page 95
... Legacy Detection :disable PSE Total Power Consumption :12000 mW PSE Available Power :268000 mW PSE Peak Value :12000 mW PSE Average Value :12000 mW PSE Software Version :290 PSE Hardware Version :000 PSE CPLD Version :021 PSE Power-Management mode :auto poe enable Syntax poe enable undo poe enable View Ethernet...
... Legacy Detection :disable PSE Total Power Consumption :12000 mW PSE Available Power :268000 mW PSE Peak Value :12000 mW PSE Average Value :12000 mW PSE Software Version :290 PSE Hardware Version :000 PSE CPLD Version :021 PSE Power-Management mode :auto poe enable Syntax poe enable undo poe enable View Ethernet...
Command Reference Guide
Page 99
...exceed the maximum power supplied by the equipment, i.e., 300W. Description Use the poe update command to the switch. In this case, no new PD can be added to update the PSE processing software online Note that is, all the PoE commands cannot be successfully executed), you can use the full mode... to the Switch. Example Set the port priority to critical. [SW5500-GigabitEthernet1/0/3]poe priority critical Set Port PSE...
...exceed the maximum power supplied by the equipment, i.e., 300W. Description Use the poe update command to the switch. In this case, no new PD can be added to update the PSE processing software online Note that is, all the PoE commands cannot be successfully executed), you can use the full mode... to the Switch. Example Set the port priority to critical. [SW5500-GigabitEthernet1/0/3]poe priority critical Set Port PSE...
Command Reference Guide
Page 100
100 CHAPTER 4: USING POWER OVER ETHERNET (POE) COMMANDS Example Update the PSE processing software online. [SW5500]poe update refresh 0290_021.s19 ...Update PoE board successfully
100 CHAPTER 4: USING POWER OVER ETHERNET (POE) COMMANDS Example Update the PSE processing software online. [SW5500]poe update refresh 0290_021.s19 ...Update PoE board successfully
Command Reference Guide
Page 283
...the sequence number of number 2000 ACL. You can be processed by a number, and enter the corresponding ACL View. By default, the ACLs are software matched times, namely, the matched times of data filtering and classification. system-view System View: return to User View with a small range); It ...The matched times displayed by this rule. ACL Configuration Command List 283 Description Use the acl command to define an ACL identified by the Switch CPU. Using the match-order, you can specify whether the match order is the user's configuration order or depth first order (it first...
...the sequence number of number 2000 ACL. You can be processed by a number, and enter the corresponding ACL View. By default, the ACLs are software matched times, namely, the matched times of data filtering and classification. system-view System View: return to User View with a small range); It ...The matched times displayed by this rule. ACL Configuration Command List 283 Description Use the acl command to define an ACL identified by the Switch CPU. Using the match-order, you can specify whether the match order is the user's configuration order or depth first order (it first...
Command Reference Guide
Page 301
...acl counter Reset the statistics information of the ACL which is used in the case of filtering or classifying the data transmitted by the software of ACL, ranging from 2000 to 65534; reset traffic-statist ic Reset statistic information of an active ACL, ranging from 0 to 3999.... acl-number: Sequence number of the Switch. QoS Configuration Commands List 301 Parameters inbound: specify the traffic received by route policy function, ACL used for control logon user, etc. ...
...acl counter Reset the statistics information of the ACL which is used in the case of filtering or classifying the data transmitted by the software of ACL, ranging from 2000 to 65534; reset traffic-statist ic Reset statistic information of an active ACL, ranging from 0 to 3999.... acl-number: Sequence number of the Switch. QoS Configuration Commands List 301 Parameters inbound: specify the traffic received by route policy function, ACL used for control logon user, etc. ...
Command Reference Guide
Page 371
... option is called a self-service server. otherwise, this function is not configured on the Switch. This string cannot contain "?" If both of the page used to specify the RADIUS scheme...-url disable command to configure self-service server URL. And a server with the self-service software is in the URL address, you must be incorporated with a RADIUS server (such as a... option is contained in grey and unavailable. AAA Configuration Commands 371 You can use the RADIUS scheme 3Com, enter the following operations: ■ Select "Change user password" on the 802.1x client. ...
... option is called a self-service server. otherwise, this function is not configured on the Switch. This string cannot contain "?" If both of the page used to specify the RADIUS scheme...-url disable command to configure self-service server URL. And a server with the self-service software is in the URL address, you must be incorporated with a RADIUS server (such as a... option is contained in grey and unavailable. AAA Configuration Commands 371 You can use the RADIUS scheme 3Com, enter the following operations: ■ Select "Change user password" on the 802.1x client. ...
Command Reference Guide
Page 414
... display startup command, to the current and the next enabling. Example Display the filenames related to display the related system software and configuration filenames used for the current view of the switch system. [SW5500]display this command in protocol sub-views. For the related command, see startup saved-configuration. display startup UNIT1...
... display startup command, to the current and the next enabling. Example Display the filenames related to display the related system software and configuration filenames used for the current view of the switch system. [SW5500]display this command in protocol sub-views. For the related command, see startup saved-configuration. display startup UNIT1...
Command Reference Guide
Page 415
... on a network but in flash memory may not match the new version's software. Related commands: save the current configuration files to flash memory. The switch configurations will be erased and the switch reconfigured. Are you execute the save [ filename | safely ] View Any view...save , display current-configuration, display saved-configuration. Perform reset saved-configuration command to erase the old configuration files. ■ When a Switch 5500G-EI is a character string of 5 to 56 characters. reset saved-configuration This will choose the default setting. It is reused on and ...
... on a network but in flash memory may not match the new version's software. Related commands: save the current configuration files to flash memory. The switch configurations will be erased and the switch reconfigured. Are you execute the save [ filename | safely ] View Any view...save , display current-configuration, display saved-configuration. Perform reset saved-configuration command to erase the old configuration files. ■ When a Switch 5500G-EI is a character string of 5 to 56 characters. reset saved-configuration This will choose the default setting. It is reused on and ...
Command Reference Guide
Page 438
Example Show device information. Example Display the working state of BOOTROM software, application version number, address learning mode, interface card type and interface card type description, etc. display fan Unit 1 Fan 1 State: Normal Fan 2 State: Normal ...current system memory status. display memory Syntax display memory [ unit unit-id ] View All views Parameter unit unit-id: Specify the Unit ID of the switch Description Use the display memory command to display the working status information of a card, including physical card number, physical daughter card number, number of ports...
Example Show device information. Example Display the working state of BOOTROM software, application version number, address learning mode, interface card type and interface card type description, etc. display fan Unit 1 Fan 1 State: Normal Fan 2 State: Normal ...current system memory status. display memory Syntax display memory [ unit unit-id ] View All views Parameter unit unit-id: Specify the Unit ID of the switch Description Use the display memory command to display the working status information of a card, including physical card number, physical daughter card number, number of ports...
Command Reference Guide
Page 447
...: Specify the Ethernet port type. Show all the enabled debugging. display debugging IP packet debugging switch is no parameter. Example Display the information about the system version. Description Use the display debugging command to view the software version, issue date and the basic hardware configuration information. For the related commands, see debugging... Parameter None Description Use the display version command to display the enabled debugging process. Example Show all the enabled debugging when there is on your Switch 5500G-EI.
...: Specify the Ethernet port type. Show all the enabled debugging. display debugging IP packet debugging switch is no parameter. Example Display the information about the system version. Description Use the display debugging command to view the software version, issue date and the basic hardware configuration information. For the related commands, see debugging... Parameter None Description Use the display version command to display the enabled debugging process. Example Show all the enabled debugging when there is on your Switch 5500G-EI.