Campbell Scientific CR1000 Support and Manuals

Get Help and Manuals for this Campbell Scientific item

View All Support Options Below
Free Campbell Scientific CR1000 manuals!
Problems with Campbell Scientific CR1000?

Ask a Question

Campbell Scientific CR1000 Videos

Multiplexer Programming with a CR1000 Data Logger
Duration: 6:10
Total Views: 4,553
Signed Integer Data from CR1000 Datalogger Using LabView and Modbus TCP/IP
Duration: 12:32
Total Views: 857
Floating Point Data from CR1000 Datalogger Using LabView and Modbus TCP/IP
Duration: 9:51
Total Views: 1,221
Part 3 Connecting CR1000 to Sampler
Duration: 3:34
Total Views: 39

Popular Campbell Scientific CR1000 Manual Pages

CR1000 Measurement and Control System - Page 8

... 59 5.1.2 Sensor Support 59 5.1.3 CR1000 Wiring Panel 60 5.1.3.1 Measurement Inputs 60 5.1.3.2 Voltage Outputs 61 5.1.3.3 Grounding Terminals 62 5.1.3.4 Power Terminals 62 5.1.3.4.1 Power In 62 5.1.3.4.2 Power Out 62 5.1.3.5 Communications Ports 63 5.1.4 CR1000KD Keyboard Display 63 5.1.5 Power Requirements 64 5.1.6 Programming 65 5.1.6.1 Operating System and Settings 65 5.1.6.2 User...
CR1000 Measurement and Control System - Page 27

...your office, Campbell Scientific dataloggers support research and operations all over the world. You can still hear the cheery HELLO echoed in the voices you need assistance with a cheery HELLO at Campbell Scientific. 1.2 Typography The following type faces used throughout the CR1000 operator's manual. Quickstart Tutorial (p. 33) gives a cursory view of CR1000 data-acquisition and walks...
CR1000 Measurement and Control System - Page 68

... then turn off . The CR1000 manages data on the use of the TableFile() instruction. 5.1.8.5 Data Format on Computer CR1000 data stored on a PC via a CF adapter can be converted to a Campbell Scientific format using CardConvert software (see the CRD: Drive (p. 334) section. 5.1.8.4 Data File-Formats in CR1000 Memory Routine CR1000 operations store data in one of data files collected via...
CR1000 Measurement and Control System - Page 77

... Station Software supports Campbell Scientific weather stations. Short Cut and CRBasic Editor are included for setting the datalogger clock, sending programs, monitoring sensors, and on a separate computer, and are available for more weather stations. • PCONNECT Palm Datalogger Software supports communications, program send, data collection, and real time monitoring of a CR1000 using...
CR1000 Measurement and Control System - Page 79

.... Section 6. Three switched voltage excitation outputs are valid from measurement with a Campbell Scientific applications engineer before purchase. 2.0 PROGRAM EXECUTION RATE 2.1 10 ms to 50°C in footnote 9: ±(0.04% of a single A/D (p. 447) conversion. SDM communications are also supported. 7.1 LOW FREQUENCY MODE MAX: INPUT CURRENT: ±1 nA typical, ±6 nA...
CR1000 Measurement and Control System - Page 106

... code. This allows the "Include" file to act both as an "Include" file and as Run On Power-up , the CR1000 loads default.cr1 if no program is to run the program listed in 1), or if the selected file cannot be the current program. Installation Note: No BeginProg Instruction!! CRBasic Example 3. Otherwise, any file marked as communication settings...
CR1000 Measurement and Control System - Page 118

... and output sections of variables (via the Dim or Public instructions) allows an optional type descriptor As that specifies the data type. The datalogger support software is declared as Public StringVar(5) As String * 36 Five variables are As String and three numeric types: As Float, As Long, and As Boolean. The CRBasic programming language allows mixing data types within a string. however...
CR1000 Measurement and Control System - Page 172

... transmissions. transparent mode and programmed mode. • Transparent mode facilitates sensor setup and troubleshooting. To set up Modbus TCP/IP, specify port 502 as the ComPort in the appendix Network Links (p. 567). 7.8.2.10 Modbus TCP/IP The CR1000 can be manually issued and the full sensor response viewed. If multiple sensors are wired to allow serial communication...
CR1000 Measurement and Control System - Page 173

...the programmed mode to wait for data recording. 7.8.3.1 SDI-12 Transparent Mode System operators can be unlocked before sending responses. Press Enter until the CR1000 responds with the CR1000 through Campbell Scientific datalogger support software (p. 77), but may not execute. Transparent mode may need to finish before transparent mode can manually interrogate and enter settings in...
CR1000 Measurement and Control System - Page 184

...instruction pair programs the CR1000 to a thirdparty SDI-12 recorder. command range from the CR1000 to other Campbell Scientific dataloggers over a single-wire interface (SDI-12 port to SDI-12 port), or to transfer data...helpful tips include: Concerning the Reps parameter in table CRBasic example SDI-12 Sensor Setup -- However, different SDI-12 ports can be found in the CRBasic Editor Help....
CR1000 Measurement and Control System - Page 351

... link to change settings, but can exist in PakBus Networking Guide, available at the...Campbell Scientific dataloggers and telecommunications peripherals to other Campbell Scientific dataloggers via PakBus®. o A leaf node cannot route packets but has no provision for backup. Operation of nodes, double-digit to the second tier, triple-digit to IP (Internet protocol). The CR1000...
CR1000 Measurement and Control System - Page 420

... troubleshooting procedures while on the outside of the problem, an RMA number will be returned without prior authorization. Affiliate companies handle repairs for repair. Section 9. Many problems can be followed when sending the product. To obtain a Returned Materials Authorization (RMA), contact CAMPBELL SCIENTIFIC, INC., phone (435) 227-2342. Occasionally, a CR1000 requires repair...
CR1000 Measurement and Control System - Page 424

... compile, and the datalogger reverted to a Campbell Scientific applications engineer, especially if the problem is too short. Section 10. A message will report that some of code referenced by the CRBasic compiler to be ignored because no longer accessible. 424 Error messages may not work. Messages report variables that the program will not be obvious because the display...
CR1000 Measurement and Control System - Page 524

...) OmniSatData Sends a table of data to a Campbell Scientific GOES satellite data transmitter. Syntax OmniSatData(OmniDataResult, TableName, TableOption, OmniBufferCtrl, DataFormat) OmniSatRandomSetup Sets up the OMNISAT transmitter to an Argos satellite when the instruction is executed. Syntax GOESGPS(GoesArray1(6), GoesArray2(7)) GOESSetup Programs the GOES transmitter for status...
CR1000 Measurement and Control System - Page 562

Other Campbell Scientific Products 4WHB10K 4WPB100 4WPB1K 10-kΩ, four-wire, half-bridge TIM module 100-Ω, four-wire, PRT-bridge TIM module 1-kΩ, four-wire, PRT-bridge TIM module F.2.5.2 Voltage Dividers Table 136. Terminal-Strip Covers Datalogger CR800 CR1000 CR3000 Terminal-Strip Cover Part Number No cover available 17324 18359 F.3 Cameras A camera can be an ...

Campbell Scientific CR1000 Reviews

Do you have an experience with the Campbell Scientific CR1000 that you would like to share?
Earn 750 points for your review!
We have not received any reviews for Campbell Scientific yet.

Popular Campbell Scientific CR1000 Search Terms

The following terms are frequently used to search for Campbell Scientific CR1000 support:

Ask a New Question
Use the box below to post a new question about Campbell Scientific CR1000.
Manuals / Documents
Download any of our Campbell Scientific CR1000 manuals for free!

We have the following 3 documents available for the Campbell Scientific CR1000:
  • CR1000 Measurement and Control System
  • PakBus NetWorking Guide
  • CR1000 Specifications
Related Items
View other Campbell Scientific Electronics Accessories:

Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

Campbell Scientific Manuals

Find free Campbell Scientific CR1000 manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Campbell Scientific Reviews

View thousands of Campbell Scientific CR1000 user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete Campbell Scientific customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed Campbell Scientific customer service rankings, employee comments and much more from our sister site.