Software Guide
Page 31
..., refer to large-scale, fully integrated internetworks. Table 1-1 describes the Catalyst 4000 series switches. Table 1-1 Catalyst 4000 Series and Catalyst 4500 Series Switches Product Number Catalyst 4000 Series WS-C4003 WS-C4006 Chassis Description Catalyst 4003 • Modular 3-slot chassis • Optional redundant power supplies Catalyst 4006 • Modular 6-slot chassis • 30-Gbps backplane • Two power supplies with optional...
..., refer to large-scale, fully integrated internetworks. Table 1-1 describes the Catalyst 4000 series switches. Table 1-1 Catalyst 4000 Series and Catalyst 4500 Series Switches Product Number Catalyst 4000 Series WS-C4003 WS-C4006 Chassis Description Catalyst 4003 • Modular 3-slot chassis • Optional redundant power supplies Catalyst 4006 • Modular 6-slot chassis • 30-Gbps backplane • Two power supplies with optional...
Software Guide
Page 32
.../100BASE-TX Fast Ethernet ports Catalyst 4500 Series, Catalyst 2948G, Catalyst 2980G Switches Software Configuration Guide-Release 8.1 1-2 78-15486-01 Table 1-2 describes the Catalyst 2948G switch. Catalyst 2948G Switch Chapter 1 Product Overview Table 1-1 Catalyst 4000 Series and Catalyst 4500 Series Switches (continued) Product Number WS-C4912G Catalyst 4500 Series WS-C4503 WS-C4506 Chassis Description Catalyst 4912G • Fixed-configuration switch • 12-Gbps backplane...
.../100BASE-TX Fast Ethernet ports Catalyst 4500 Series, Catalyst 2948G, Catalyst 2980G Switches Software Configuration Guide-Release 8.1 1-2 78-15486-01 Table 1-2 describes the Catalyst 2948G switch. Catalyst 2948G Switch Chapter 1 Product Overview Table 1-1 Catalyst 4000 Series and Catalyst 4500 Series Switches (continued) Product Number WS-C4912G Catalyst 4500 Series WS-C4503 WS-C4506 Chassis Description Catalyst 4912G • Fixed-configuration switch • 12-Gbps backplane...
Software Guide
Page 33
... can configure modules and ports on the switches. Chapter 1 Product Overview Catalyst 2980G Switch Catalyst 2980G Switch Note For installation information and a complete description of the available CLI commands, refer to the Catalyst 2948G and 2980G Installation Guide. Table 1-3 Catalyst 2980G Switch Product Number WS-C2980G-A Chassis Description Catalyst 2980G • Fixed-configuration switch • 12-Gbps backplane • Optional redundant...
... can configure modules and ports on the switches. Chapter 1 Product Overview Catalyst 2980G Switch Catalyst 2980G Switch Note For installation information and a complete description of the available CLI commands, refer to the Catalyst 2948G and 2980G Installation Guide. Table 1-3 Catalyst 2980G Switch Product Number WS-C2980G-A Chassis Description Catalyst 2980G • Fixed-configuration switch • 12-Gbps backplane • Optional redundant...
Software Guide
Page 76
...a router, a host, or another switch. If a port within the EtherChannel. You can also configure identical trunk ports as trunk links. For more information, see the "Understanding the LACP" section on page 6-5. Hardware Support for a 6-slot chassis. To use PAgP, see the "... on Fast Ethernet and Gigabit Ethernet Ports." Catalyst 4500 Series, Catalyst 2948G, Catalyst 2980G Switches Software Configuration Guide-Release 8.1 6-2 78-15486-01 Ports in an EtherChannel according to be run only on Cisco switches and those switches released by the spanning tree feature, the...
...a router, a host, or another switch. If a port within the EtherChannel. You can also configure identical trunk ports as trunk links. For more information, see the "Understanding the LACP" section on page 6-5. Hardware Support for a 6-slot chassis. To use PAgP, see the "... on Fast Ethernet and Gigabit Ethernet Ports." Catalyst 4500 Series, Catalyst 2948G, Catalyst 2980G Switches Software Configuration Guide-Release 8.1 6-2 78-15486-01 Ports in an EtherChannel according to be run only on Cisco switches and those switches released by the spanning tree feature, the...
Software Guide
Page 110
... an MST region. 7-14 Catalyst 4500 Series, Catalyst 2948G, Catalyst 2980G Switches Software Configuration Guide-Release 8.1 78-15486-01 MST allows you add a Catalyst 4500 series switch with 802.1D STP, 802.1w, the Rapid Spanning Tree Protocol (RSTP), and the Cisco PVST+ architecture. Network fault ... the chassis with the same MST configuration information, allowing them to participate in one instance (forwarding path) does not affect other spanning tree instances. Interconnected bridges that is a root switch In this switch cannot become the root switch. • The Catalyst 4006 is...
... an MST region. 7-14 Catalyst 4500 Series, Catalyst 2948G, Catalyst 2980G Switches Software Configuration Guide-Release 8.1 78-15486-01 MST allows you add a Catalyst 4500 series switch with 802.1D STP, 802.1w, the Rapid Spanning Tree Protocol (RSTP), and the Cisco PVST+ architecture. Network fault ... the chassis with the same MST configuration information, allowing them to participate in one instance (forwarding path) does not affect other spanning tree instances. Interconnected bridges that is a root switch In this switch cannot become the root switch. • The Catalyst 4006 is...
Software Guide
Page 375
...172.16.10.10 read -write-all Note To disable access for the community string). 78-15486-01 Catalyst 4500 Series, Catalyst 2948G, Catalyst 2980G Switches Software Configuration Guide-Release 8.1 24-7 Console> (enable) show snmp This example shows how to define ...enabled. You set to the null string (do not enter a value for an SNMP community, set to 'Administrators'. set snmp trap enable all | auth | bridge | chassis | config | entity | entityfru | envfan | envpower | envshutdown | envtemp | flashinsert | flashremove | ippermit | module | stpx | syslog | system | vlancreate |...
...172.16.10.10 read -write-all Note To disable access for the community string). 78-15486-01 Catalyst 4500 Series, Catalyst 2948G, Catalyst 2980G Switches Software Configuration Guide-Release 8.1 24-7 Console> (enable) show snmp This example shows how to define ...enabled. You set to the null string (do not enter a value for an SNMP community, set to 'Administrators'. set snmp trap enable all | auth | bridge | chassis | config | entity | entityfru | envfan | envpower | envshutdown | envtemp | flashinsert | flashremove | ippermit | module | stpx | syslog | system | vlancreate |...
Software Guide
Page 388
...). Enabling RMON Chapter 25 Configuring RMON Enabling RMON Note RMON is disabled by the supervisor engine software. 25-2 Catalyst 4500 Series, Catalyst 2948G, Catalyst 2980G Switches Software Configuration Guide-Release 8.1 78-15486-01 Command set snmp rmon enable SNMP RMON support enabled. You cannot ...access RMON data through the switch CLI; Verify that RMON is enabled: Console> (enable) set snmp rmon enable show snmp RMON: Enabled Extended RMON: Extended RMON module is not present Traps Enabled: Port,Module,Chassis,Bridge,Repeater,Vtp,Auth,ippermit,Vmps,...
...). Enabling RMON Chapter 25 Configuring RMON Enabling RMON Note RMON is disabled by the supervisor engine software. 25-2 Catalyst 4500 Series, Catalyst 2948G, Catalyst 2980G Switches Software Configuration Guide-Release 8.1 78-15486-01 Command set snmp rmon enable SNMP RMON support enabled. You cannot ...access RMON data through the switch CLI; Verify that RMON is enabled: Console> (enable) set snmp rmon enable show snmp RMON: Enabled Extended RMON: Extended RMON module is not present Traps Enabled: Port,Module,Chassis,Bridge,Repeater,Vtp,Auth,ippermit,Vmps,...
Software Guide
Page 412
... using the Network Time Protocol (NTP). Setting the System Clock Chapter 27 Administering the Switch disable 9600 0% 0% Wed Apr 24 2002, 15:46:01 Power Capacity of the Chassis:2 supplies WARNING:Power supplies of the day. After entering the ending delimiter, press Return... the switch. For information on the screen when someone logs in privileged mode: Step 1 Step 2 Task Set the system clock. Display the current date and time. To set banner motd c message_of_the_day c - 27-4 Catalyst 4500 Series, Catalyst 2948G, Catalyst 2980G Switches Software Configuration Guide-Release 8.1 ...
... using the Network Time Protocol (NTP). Setting the System Clock Chapter 27 Administering the Switch disable 9600 0% 0% Wed Apr 24 2002, 15:46:01 Power Capacity of the Chassis:2 supplies WARNING:Power supplies of the day. After entering the ending delimiter, press Return... the switch. For information on the screen when someone logs in privileged mode: Step 1 Step 2 Task Set the system clock. Display the current date and time. To set banner motd c message_of_the_day c - 27-4 Catalyst 4500 Series, Catalyst 2948G, Catalyst 2980G Switches Software Configuration Guide-Release 8.1 ...
Software Guide
Page 423
... See Table 28-1 on page 28-4 for a list of the maximum available power for chassis and inline power for each power supply. 78-15486-01 Catalyst 4500 Series, Catalyst 2948G, Catalyst 2980G Switches Software Configuration Guide-Release 8.1 28-3 The power supplies have power redundancy. • When... for using redundant mode in the Catalyst 4500 series switches: • By default, the power supplies in a Catalyst 4500 series switch are less than the maximum available power for the chassis and inline power for the power supply. Your switch will have no power redundancy. •...
... See Table 28-1 on page 28-4 for a list of the maximum available power for chassis and inline power for each power supply. 78-15486-01 Catalyst 4500 Series, Catalyst 2948G, Catalyst 2980G Switches Software Configuration Guide-Release 8.1 28-3 The power supplies have power redundancy. • When... for using redundant mode in the Catalyst 4500 series switches: • By default, the power supplies in a Catalyst 4500 series switch are less than the maximum available power for the chassis and inline power for the power supply. Your switch will have no power redundancy. •...
Software Guide
Page 424
... section describes the power-management limitations for specified configuration. 28-4 Catalyst 4500 Series, Catalyst 2948G, Catalyst 2980G Switches Software Configuration Guide-Release 8.1 78-15486-01 For more information,...Chassis = 1360 Chassis = 2473 In-line = 1400 Inline = 2545 1. The chassis power includes power for the 1400 W DC power supply and is provided by the power supplies. • If you insert a single power supply into the switch and then set combined mode, the switch displays this message: Insufficient power supplies present for the Catalyst 4500 series switches...
... section describes the power-management limitations for specified configuration. 28-4 Catalyst 4500 Series, Catalyst 2948G, Catalyst 2980G Switches Software Configuration Guide-Release 8.1 78-15486-01 For more information,...Chassis = 1360 Chassis = 2473 In-line = 1400 Inline = 2545 1. The chassis power includes power for the 1400 W DC power supply and is provided by the power supplies. • If you insert a single power supply into the switch and then set combined mode, the switch displays this message: Insufficient power supplies present for the Catalyst 4500 series switches...
Software Guide
Page 425
...Insufficient power available for the current chassis configuration. • If you try to insert additional modules that exceed the power of DC sources. The inline power is working properly. 78-15486-01 Catalyst 4500 Series, Catalyst 2948G, Catalyst 2980G Switches Software Configuration Guide-Release 8.1 28...-5 The power supply fan status is tied to the power supply status so that is installed in the chassis. 1400 W DC Power Supply Guidelines and...
...Insufficient power available for the current chassis configuration. • If you try to insert additional modules that exceed the power of DC sources. The inline power is working properly. 78-15486-01 Catalyst 4500 Series, Catalyst 2948G, Catalyst 2980G Switches Software Configuration Guide-Release 8.1 28...-5 The power supply fan status is tied to the power supply status so that is installed in the chassis. 1400 W DC Power Supply Guidelines and...
Software Guide
Page 426
Understanding How Power Management Works on the Catalyst 4006 Switch Chapter 28 Power Management Understanding How Power Management Works on page 28-1. If you use the 1+1 redundancy mode in these hardware configurations: • One Catalyst 4006 chassis with a WS-X4013 supervisor engine with two 400 W power supplies (in 1+1 ... to manage power for up to operate in 2+1 redundancy mode (the default mode), there is supplied by the power supply. The Catalyst 4000 series switch chassis supports only the 400 W AC, 400 W DC, and 650 W DC power supplies and allows you use AC-input and DC...
Understanding How Power Management Works on the Catalyst 4006 Switch Chapter 28 Power Management Understanding How Power Management Works on page 28-1. If you use the 1+1 redundancy mode in these hardware configurations: • One Catalyst 4006 chassis with a WS-X4013 supervisor engine with two 400 W power supplies (in 1+1 ... to manage power for up to operate in 2+1 redundancy mode (the default mode), there is supplied by the power supply. The Catalyst 4000 series switch chassis supports only the 400 W AC, 400 W DC, and 650 W DC power supplies and allows you use AC-input and DC...
Software Guide
Page 427
... capacity restriction applies to use a 1+1 redundancy configuration, you must change the module configuration inappropriately and power on the switch again, the module(s) in the chassis than the single power supply provides, the switch places the newly inserted module into reset mode. 78-15486-01 Catalyst 4500 Series, Catalyst 2948G, Catalyst 2980G Switches Software Configuration Guide-Release 8.1 28-7
... capacity restriction applies to use a 1+1 redundancy configuration, you must change the module configuration inappropriately and power on the switch again, the module(s) in the chassis than the single power supply provides, the switch places the newly inserted module into reset mode. 78-15486-01 Catalyst 4500 Series, Catalyst 2948G, Catalyst 2980G Switches Software Configuration Guide-Release 8.1 28-7
Software Guide
Page 428
... several evaluation cycles to 2+1 redundancy mode, each (600 W total) • Fan tray-25 W 28-8 Catalyst 4500 Series, Catalyst 2948G, Catalyst 2980G Switches Software Configuration Guide-Release 8.1 78-15486-01 During the evaluation cycle, the modules are required to stabilize the chassis' power usage. You must remove the failed 400 W power supply so that exceed the...
... several evaluation cycles to 2+1 redundancy mode, each (600 W total) • Fan tray-25 W 28-8 Catalyst 4500 Series, Catalyst 2948G, Catalyst 2980G Switches Software Configuration Guide-Release 8.1 78-15486-01 During the evaluation cycle, the modules are required to stabilize the chassis' power usage. You must remove the failed 400 W power supply so that exceed the...
Software Guide
Page 430
... your configuration and reload the configuration file after you insert the supervisor engine into the Catalyst 4500 series chassis. Migrating a Supervisor Engine II from a Catalyst 4006 Switch to a Catalyst 4500 Series Switch Chapter 28 Power Management Table 28-2 Power Consumption for Catalyst 4500 Series and 4000 Series Components (continued) Module 48-port 1000BASE-X Gigabit Ethernet WS-X4448...
... your configuration and reload the configuration file after you insert the supervisor engine into the Catalyst 4500 series chassis. Migrating a Supervisor Engine II from a Catalyst 4006 Switch to a Catalyst 4500 Series Switch Chapter 28 Power Management Table 28-2 Power Consumption for Catalyst 4500 Series and 4000 Series Components (continued) Module 48-port 1000BASE-X Gigabit Ethernet WS-X4448...
Software Guide
Page 431
... 6.3 W per port for each module. • Total available inline power that can set each port; Table 28-3 Switch Components Supporting Inline Power Switch Chassis Catalyst 4006 Catalyst 4503 Catalyst 4506 Modules WS-X4148-RJ45V WS-X4148-RJ45V Power Supplies Catalyst 4000 Series Power Entry Module (PEM) 1300 W AC 2800 W AC 1400 W DC You can utilize inline power...
... 6.3 W per port for each module. • Total available inline power that can set each port; Table 28-3 Switch Components Supporting Inline Power Switch Chassis Catalyst 4006 Catalyst 4503 Catalyst 4506 Modules WS-X4148-RJ45V WS-X4148-RJ45V Power Supplies Catalyst 4000 Series Power Entry Module (PEM) 1300 W AC 2800 W AC 1400 W DC You can utilize inline power...
Software Guide
Page 437
...Peak-Time disable 9600 0% 0% Fri May 31 2002, 10:24:04 Power Capacity of the Chassis: 1 supply 78-15486-01 Catalyst 4500 Series, Catalyst 2948G, Catalyst 2980G Switches Software Configuration Guide-Release 8.1 28-17 Chapter 28 Power Management Configuring Power Management This example shows ...for the show system command with mixed power supplies: Switch# show environment power Total Inline Power Available:0 Watt Total Inline Power Drawn From the System:0 Watt Remaining Inline Power in the chassis and other chassis information, perform this task: Task Display system information...
...Peak-Time disable 9600 0% 0% Fri May 31 2002, 10:24:04 Power Capacity of the Chassis: 1 supply 78-15486-01 Catalyst 4500 Series, Catalyst 2948G, Catalyst 2980G Switches Software Configuration Guide-Release 8.1 28-17 Chapter 28 Power Management Configuring Power Management This example shows ...for the show system command with mixed power supplies: Switch# show environment power Total Inline Power Available:0 Watt Total Inline Power Drawn From the System:0 Watt Remaining Inline Power in the chassis and other chassis information, perform this task: Task Display system information...
Software Guide
Page 441
... Cisco CallManager are as follows: • Catalyst 4006, Catalyst 4500 series, Catalyst 5000 family, and Catalyst 6500 series switches running supervisor engine software release 6.1(1) or later releases • Catalyst 4006, Catalyst 4500 series, and Catalyst 6500 series switches running supervisor engine software release 8.1 or later releases for the Catalyst 4500 series switches. Table 29-1 Catalyst 4500 Series Components Supporting Inline Power Switch Chassis Catalyst 4006 Catalyst 4503 Catalyst...
... Cisco CallManager are as follows: • Catalyst 4006, Catalyst 4500 series, Catalyst 5000 family, and Catalyst 6500 series switches running supervisor engine software release 6.1(1) or later releases • Catalyst 4006, Catalyst 4500 series, and Catalyst 6500 series switches running supervisor engine software release 8.1 or later releases for the Catalyst 4500 series switches. Table 29-1 Catalyst 4500 Series Components Supporting Inline Power Switch Chassis Catalyst 4006 Catalyst 4503 Catalyst...
Software Guide
Page 555
... 1/1 and traffic between modules installed in the chassis. • SE3 handles traffic for the commands used in on the Catalyst 4000 family supervisor engine. To avoid such congestion, you can disable the uplink ports and create a direct internal link between the switch engines (SEs). 36 C H A P T E R Configuring Switch Acceleration This chapter describes the Backplane Channel...
... 1/1 and traffic between modules installed in the chassis. • SE3 handles traffic for the commands used in on the Catalyst 4000 family supervisor engine. To avoid such congestion, you can disable the uplink ports and create a direct internal link between the switch engines (SEs). 36 C H A P T E R Configuring Switch Acceleration This chapter describes the Backplane Channel...