Compaq Leadership in Server Innovations
Page 5
... automatically installing and configuring Compaq systems. SmartStart assists users and resellers in successfully setting up -todate version available from Compaq. In addition, Insight Manager uses SNMP to a proven and tested server configuration. Compaq's integration labs, testing facilities, and design criteria also provide expertise that drives development of many components such as NIC throughput. is Compaq's intelligent integration tool that addresses three critical server management needs: configuration, performance monitoring, and fault prediction. Doc. No. Compaq first...
... automatically installing and configuring Compaq systems. SmartStart assists users and resellers in successfully setting up -todate version available from Compaq. In addition, Insight Manager uses SNMP to a proven and tested server configuration. Compaq's integration labs, testing facilities, and design criteria also provide expertise that drives development of many components such as NIC throughput. is Compaq's intelligent integration tool that addresses three critical server management needs: configuration, performance monitoring, and fault prediction. Doc. No. Compaq first...
intraNetWare Symmetric Multiprocessing
Page 9
... later as they become available, they should use the latest support modules as the Primary Operating System and press ENTER. 4. You may occur. NLM Updates During Installation NOTE: This section is not loaded. First, update the STARTUP.NCF file to prevent attempts to restart the server. Run the Compaq System Configuration Utility. 2. When you load MONITOR.NLM, you will see several new statistics...
... later as they become available, they should use the latest support modules as the Primary Operating System and press ENTER. 4. You may occur. NLM Updates During Installation NOTE: This section is not loaded. First, update the STARTUP.NCF file to prevent attempts to restart the server. Run the Compaq System Configuration Utility. 2. When you load MONITOR.NLM, you will see several new statistics...
LAN Driver Statistics for Novell Drivers
Page 11
... be on the network from a controller. Network Link Status (0=up ). If none of the link. If a hub or controller detects interference or invalid data control sequences, training will be used to verify the operation of network analyzer products such as the device to ensure that there is connected. If you determine if a problem exists. 3. Link Speed (bits per second) This indicates the speed that the driver has been operating. VG Transitions Into...
... be on the network from a controller. Network Link Status (0=up ). If none of the link. If a hub or controller detects interference or invalid data control sequences, training will be used to verify the operation of network analyzer products such as the device to ensure that there is connected. If you determine if a problem exists. 3. Link Speed (bits per second) This indicates the speed that the driver has been operating. VG Transitions Into...
PCI Bus Numbering in a Microsoft Windows NT Environment
Page 19
... to configure and verify hardware installations and modifications to view the slot and bus number assignments before the server is powered on. • Gather all network and disk controllers included in the configuration are detailed in the "Planning the New Configuration" section. to configure the hardware and to the system in a Microsoft Windows NT Environment 19 Step-By-Step Review The Compaq Array Configuration Utility can better comprehend how PCI Bus numbers reassign when configuration changes occur...
... to configure and verify hardware installations and modifications to view the slot and bus number assignments before the server is powered on. • Gather all network and disk controllers included in the configuration are detailed in the "Planning the New Configuration" section. to configure the hardware and to the system in a Microsoft Windows NT Environment 19 Step-By-Step Review The Compaq Array Configuration Utility can better comprehend how PCI Bus numbers reassign when configuration changes occur...
PCI Bus Numbering in a Microsoft Windows NT Environment
Page 49
... first network controller detected by the PCI BIOS. It is different than previous configuration. The PCI BIOS increments the PCI bus number to 5 changing the bus number assignment on the controller. Description of PCI BIOS Discovery Process As with Test 1, the PCI BIOS assigns 0 to the Primary Bus and continues downstream with a PCI bridge detected in slot 6. Intelligent drive array controller with the controller discovery process. A PCI bridged Intelligent drive array controller was ADDED to the server in slot 5. All bus numbers assigned later in the ProLiant...
... first network controller detected by the PCI BIOS. It is different than previous configuration. The PCI BIOS increments the PCI bus number to 5 changing the bus number assignment on the controller. Description of PCI BIOS Discovery Process As with Test 1, the PCI BIOS assigns 0 to the Primary Bus and continues downstream with a PCI bridge detected in slot 6. Intelligent drive array controller with the controller discovery process. A PCI bridged Intelligent drive array controller was ADDED to the server in slot 5. All bus numbers assigned later in the ProLiant...
SMART-2DH Array Controller Reference Guide
Page 82
... Array Controller with a drive that the connection was successful. NEED TO KNOW REQUIRED Remove the failed drive and replace it to recreate the previous image. Recovering Drives Configured for Hardware Fault Tolerance If you configure your NetWare/intraNetWare server. On hot-pluggable drives in the bay, the LEDs on your DOS partition, use your STARTUP.NCF file. For hot-pluggable drives, after a disk drive failure. 1. 6-14 Installing the Operating System Drivers 9. If you secure the drive in a ProLiant server or storage...
... Array Controller with a drive that the connection was successful. NEED TO KNOW REQUIRED Remove the failed drive and replace it to recreate the previous image. Recovering Drives Configured for Hardware Fault Tolerance If you configure your NetWare/intraNetWare server. On hot-pluggable drives in the bay, the LEDs on your DOS partition, use your STARTUP.NCF file. For hot-pluggable drives, after a disk drive failure. 1. 6-14 Installing the Operating System Drivers 9. If you secure the drive in a ProLiant server or storage...
SMART-2DH Array Controller Reference Guide
Page 95
... install the driver using the Windows NT Support Software Diskette utility during initial Windows NT installation. At the next screen, press S to install additional device support, repeat steps 4-8. If it is necessary to specify additional SCSI controllers. 5. After the driver has been loaded into memory, the Setup program will return to skip detection. 4. Otherwise, continue with step 9. 9. Highlight Compaq Drive Array in step 4. Some device drivers are installed during the initial installation of recognized mass storage devices...
... install the driver using the Windows NT Support Software Diskette utility during initial Windows NT installation. At the next screen, press S to install additional device support, repeat steps 4-8. If it is necessary to specify additional SCSI controllers. 5. After the driver has been loaded into memory, the Setup program will return to skip detection. 4. Otherwise, continue with step 9. 9. Highlight Compaq Drive Array in step 4. Some device drivers are installed during the initial installation of recognized mass storage devices...
SMART-2DH Array Controller Reference Guide
Page 176
...cabling problem with the system board integrated SCSI controller. This message indicates that logical drive configuration has been updated automatically following physical drive position changes. H-1 Appendix H POST Error Messages The SMART-2DH Controller produces diagnostic error messages at some time in the SMART-2DH Array Controller Installation Guide for troubleshooting. System Halted. Hard Drive Detects Imminent Failure SCSI: Port y: SCSI ID x. If this drive is part of a faulttolerant configuration, do not replace this drive is part of these Power-On Self-Test (POST) messages...
...cabling problem with the system board integrated SCSI controller. This message indicates that logical drive configuration has been updated automatically following physical drive position changes. H-1 Appendix H POST Error Messages The SMART-2DH Controller produces diagnostic error messages at some time in the SMART-2DH Array Controller Installation Guide for troubleshooting. System Halted. Hard Drive Detects Imminent Failure SCSI: Port y: SCSI ID x. If this drive is part of a faulttolerant configuration, do not replace this drive is part of these Power-On Self-Test (POST) messages...
ProLiant Server Troubleshooting Guide
Page 59
... removing power to the slot using the PCI Hot Plug Utility (if supported by your server-specific user documentation to enable this technology. The PPM is installed correctly. Some requirements may not power up. In either case, replace the PPM. PCI or PCI-X Hot Plug device drivers and operating system support are occurring, be the same size, type, and speed. If errors are required to determine if the memory is no longer redundant. Refer to remove, replace, upgrade, and add PCI or PCI-X expansion boards without redundancy, displaying a message...
... removing power to the slot using the PCI Hot Plug Utility (if supported by your server-specific user documentation to enable this technology. The PPM is installed correctly. Some requirements may not power up. In either case, replace the PPM. PCI or PCI-X Hot Plug device drivers and operating system support are occurring, be the same size, type, and speed. If errors are required to determine if the memory is no longer redundant. Refer to remove, replace, upgrade, and add PCI or PCI-X expansion boards without redundancy, displaying a message...
ProLiant Server Troubleshooting Guide
Page 69
... connected to turn off, but in some situations a problem could exist with the cause of a hot-plug hard drive. The backplane board automatically sets the ID when the drive is used, it should be installed adjacent to each corresponding drive, when configured as a part of the hot-plug drive often causes the fault LED to a powered-up Smart Array Controller. Hardware Problems CAUTION: Before removing a hot-plug drive, refer to "Unsafe Hot-Plug Drive Replacement Precautions" in this chapter to your server-specific user documentation...
... connected to turn off, but in some situations a problem could exist with the cause of a hot-plug hard drive. The backplane board automatically sets the ID when the drive is used, it should be installed adjacent to each corresponding drive, when configured as a part of the hot-plug drive often causes the fault LED to a powered-up Smart Array Controller. Hardware Problems CAUTION: Before removing a hot-plug drive, refer to "Unsafe Hot-Plug Drive Replacement Precautions" in this chapter to your server-specific user documentation...
ProLiant Server Troubleshooting Guide
Page 136
... Management Log Messages The Integrated Management Log (IML) records memory errors, as well as catastrophic hardware and software errors, that cause the system to restart the operating system or Diagnostics without user intervention. The Diagnostics utility either resolves the error or suggests corrective action in the server setup utility). HP Servers Troubleshooting Guide 5-15 Set the server to the server configuration. During attended ASR-2 (local or remote), you must enter this Administrator Password before any modifications can view the...
... Management Log Messages The Integrated Management Log (IML) records memory errors, as well as catastrophic hardware and software errors, that cause the system to restart the operating system or Diagnostics without user intervention. The Diagnostics utility either resolves the error or suggests corrective action in the server setup utility). HP Servers Troubleshooting Guide 5-15 Set the server to the server configuration. During attended ASR-2 (local or remote), you must enter this Administrator Password before any modifications can view the...
ProLiant Server Troubleshooting Guide
Page 155
... the setup and installation guide, the maintenance and service guide, and the hardware configuration and installation poster. A forum to post questions to technical support or other information related to HP. Use the following Internet email address: support@compaq.com Contact these Internet providers directly for more information: • America Online • CompuServe • Prodigy Access the following website: www.compaq.com/support/servers and select your server. You can access HP utility files, drivers, software...
... the setup and installation guide, the maintenance and service guide, and the hardware configuration and installation poster. A forum to post questions to technical support or other information related to HP. Use the following Internet email address: support@compaq.com Contact these Internet providers directly for more information: • America Online • CompuServe • Prodigy Access the following website: www.compaq.com/support/servers and select your server. You can access HP utility files, drivers, software...
ProLiant Server Troubleshooting Guide
Page 238
...): SCSI Port Y SCSI ID Z None Drive firmware update needed. 1771-Primary Disk Port Address Assignment Conflict None Internal and external hard drive controllers are running firmware that is older than data found in array accelerator is known to cause intermittent problems. Use the Options ROMPaq utility to upgrade firmware on the following website: www.compaq.com/support Run the server setup utility and correct. Data found on another controller and reconnected to the latest revision. SCSI Drive Firmware Update Recommended - continued C-58 HP Servers Troubleshooting Guide...
...): SCSI Port Y SCSI ID Z None Drive firmware update needed. 1771-Primary Disk Port Address Assignment Conflict None Internal and external hard drive controllers are running firmware that is older than data found in array accelerator is known to cause intermittent problems. Use the Options ROMPaq utility to upgrade firmware on the following website: www.compaq.com/support Run the server setup utility and correct. Data found on another controller and reconnected to the latest revision. SCSI Drive Firmware Update Recommended - continued C-58 HP Servers Troubleshooting Guide...
ProLiant Server Troubleshooting Guide
Page 301
...array array controller maximum operating temperature exceeded during previous power up C-54 Index-26 HP Servers Troubleshooting Guide Index setup and installation guides, accessing through website A-2 short circuits 1-7, 1-10, 2-8 shut down, defined xiii shutting down the server 1-3 SIMMs (single inline memory modules) ECC multiple bit error detected C-4 POST error messages C-4, C-15 single inline memory modules See SIMMs single-ended drive D-24 slot 1 drive array performance optimization scan in progress C-53 slot 1 drive array recovery needed C-64 slot fan See also fans slot fan failure...
...array array controller maximum operating temperature exceeded during previous power up C-54 Index-26 HP Servers Troubleshooting Guide Index setup and installation guides, accessing through website A-2 short circuits 1-7, 1-10, 2-8 shut down, defined xiii shutting down the server 1-3 SIMMs (single inline memory modules) ECC multiple bit error detected C-4 POST error messages C-4, C-15 single inline memory modules See SIMMs single-ended drive D-24 slot 1 drive array performance optimization scan in progress C-53 slot 1 drive array recovery needed C-64 slot fan See also fans slot fan failure...
ProLiant Server Troubleshooting Guide
Page 302
Index slot z drive array controller - redundant ROM reprogramming C-49 slot z drive array RAID 5 logical drive(s) configured with 56 drives, but array accelerator size redundant ROM checksum error C-49 slot z drive array controller -
Index slot z drive array controller - redundant ROM reprogramming C-49 slot z drive array RAID 5 logical drive(s) configured with 56 drives, but array accelerator size redundant ROM checksum error C-49 slot z drive array controller -
Installation and Configuration Guide for Linux and Apache Web Server on Compaq Prosignia and ProLiant Servers
Page 11
... three distributions covered in this guide, Caldera, Red Hat, and SuSE, either detect this card automatically or allow for manual selection of this time, the embedded NIC card on the Compaq ProLiant 1600, 1600R, and 1850R is based on the Texas Instruments ThunderLAN chipset. Similar dual-speed and single-speed PCI cards are as follows: At this device driver and the setup of the network in a rebuilt...
... three distributions covered in this guide, Caldera, Red Hat, and SuSE, either detect this card automatically or allow for manual selection of this time, the embedded NIC card on the Compaq ProLiant 1600, 1600R, and 1850R is based on the Texas Instruments ThunderLAN chipset. Similar dual-speed and single-speed PCI cards are as follows: At this device driver and the setup of the network in a rebuilt...
Installation and Configuration Guide for Linux and Apache Web Server on Compaq Prosignia and ProLiant Servers
Page 16
... a SMART Array Controller according to the installation instructions listed in Appendix B, then be sure to set the SCSI controller temporarily to be set up the Compaq System Partition so that the server must be the first boot device. Boot the SmartStart CD. 7. When prompted, choose Manual Configuration. 8. If it will reboot a final time to set after the Linux installation. The system now prompts you to remove the SmartStart CD to prepare for ProLiant server setups...
... a SMART Array Controller according to the installation instructions listed in Appendix B, then be sure to set the SCSI controller temporarily to be set up the Compaq System Partition so that the server must be the first boot device. Boot the SmartStart CD. 7. When prompted, choose Manual Configuration. 8. If it will reboot a final time to set after the Linux installation. The system now prompts you to remove the SmartStart CD to prepare for ProLiant server setups...
Installation and Configuration Guide for Linux and Apache Web Server on Compaq Prosignia and ProLiant Servers
Page 17
... handle server configuration, a ROMbased setup utility can press the F10 key at boot time by pressing left intact when creating operating system and swap partitions. You are set locale, date and time parameters. 19. You must boot the CD and place the SPD disk into the floppy drive after the Linux setup, you have NCR53C8XX SCSI controllers, and Red Hat's installation software can properly auto-detect them. SCSI Installation The...
... handle server configuration, a ROMbased setup utility can press the F10 key at boot time by pressing left intact when creating operating system and swap partitions. You are set locale, date and time parameters. 19. You must boot the CD and place the SPD disk into the floppy drive after the Linux setup, you have NCR53C8XX SCSI controllers, and Red Hat's installation software can properly auto-detect them. SCSI Installation The...
Installation and Configuration Guide for Linux and Apache Web Server on Compaq Prosignia and ProLiant Servers
Page 22
... section documents how to set up to allow for Apache application. Additional screens follow to the installer. 6. Since Compaq servers use the same device driver module, then you should return to the main menu to begin the setup configuration by pressing left up at this command prompt, you should elect the Replace option to the main menu. 5. After the software installation is chosen, you can successively run ifconfig...
... section documents how to set up to allow for Apache application. Additional screens follow to the installer. 6. Since Compaq servers use the same device driver module, then you should return to the main menu to begin the setup configuration by pressing left up at this command prompt, you should elect the Replace option to the main menu. 5. After the software installation is chosen, you can successively run ifconfig...
Installation and Configuration Guide for Linux and Apache Web Server on Compaq Prosignia and ProLiant Servers
Page 24
... section Network Interface Controller). If the hard drive or NIC cards do not show up at www.xfree86.org/3.3.3.1/QuickStart.html. The video card parameters for the Intel NIC. In Compaq's testing, a Compaq 171FS monitor and the generic SVGA X-windows server were used , you to answer this guide without any of these programs is present ECG513/0399 Caldera Similar to auto-probe the hardware. It allows for autodetection of devices...
... section Network Interface Controller). If the hard drive or NIC cards do not show up at www.xfree86.org/3.3.3.1/QuickStart.html. The video card parameters for the Intel NIC. In Compaq's testing, a Compaq 171FS monitor and the generic SVGA X-windows server were used , you to answer this guide without any of these programs is present ECG513/0399 Caldera Similar to auto-probe the hardware. It allows for autodetection of devices...