Table of Contents Model List 1 PDU Naming Convention 1 Package Contents 2 Safety Precautions 2 Installation 3 Horizontal Installation 3 Vertical Installation with Brackets ... 4 Vertical Installation Keyhole Mounts (0U models only) ... 5 Cord Retention Tray installation ....... 5 Meter Configuration 5 Electrical Installation 6 Troubleshooting 6 Product Features Technical Specification 7 Basic Series 7 Metered Series 9 Basic Series (0U 10 Metered Series (0U 11 Warranty & Service 12
Table of Contents Model List 1 PDU Naming Convention 1 Package Contents 2 Safety Precautions 2 Installation 3 Horizontal Installation 3 Vertical Installation with Brackets ... 4 Vertical Installation Keyhole Mounts (0U models only) ... 5 Cord Retention Tray installation ....... 5 Meter Configuration 5 Electrical Installation 6 Troubleshooting 6 Product Features Technical Specification 7 Basic Series 7 Metered Series 9 Basic Series (0U 10 Metered Series (0U 11 Warranty & Service 12
User Manual
Page 3
Model List: Basic Series: PDU15B8R PDU15B10R PDU15B12R PDU20B8R PDU20B10R PDU20B12R PDU20BT8R PDU20BT10R PDU20BT12R PDU15B2F8R PDU15B2F10R PDU15B2F12R PDU15B4F8R PDU15B4F10R ... 5 6 7 8 1. Input Voltage: 5. Outlet Number Front 7. Example 8F Number of Outlets followed by R - Outlet Number Rear 8. Rack Space: 4. Plug Type: 6. Amperage: 2. Example 8R NET 1 For information on Cyberpower products, visit www.cyberpower.com Series: 3. Network Management Amperage - 15A, 20A, 30A B: =Basic M: =Metered SW: = Switched NULL: =Horizontal V:= Vertical NULL: =120V HV:= High...
Model List: Basic Series: PDU15B8R PDU15B10R PDU15B12R PDU20B8R PDU20B10R PDU20B12R PDU20BT8R PDU20BT10R PDU20BT12R PDU15B2F8R PDU15B2F10R PDU15B2F12R PDU15B4F8R PDU15B4F10R ... 5 6 7 8 1. Input Voltage: 5. Outlet Number Front 7. Example 8F Number of Outlets followed by R - Outlet Number Rear 8. Rack Space: 4. Plug Type: 6. Amperage: 2. Example 8R NET 1 For information on Cyberpower products, visit www.cyberpower.com Series: 3. Network Management Amperage - 15A, 20A, 30A B: =Basic M: =Metered SW: = Switched NULL: =Horizontal V:= Vertical NULL: =120V HV:= High...
User Manual
Page 4
... humidity controlled indoor area free of power outlet may cause damage that the power cord, plug, and socket are missing parts please contact CyberPower technical support at www.cyberpower.com or call 1-877-297-6937. CAUTION! varies by model) Horizontal Installation Used (1 set) Vertical Installation Vertical Mounting Brackets (1 set) Used (1 set) (for Cord Retention Tray Ground Screw M4 X 6 (1 pcs) Documentation: User Manual DistriPbuotwioenr Unit User's Manual Product Registration Card Product Registration...
... humidity controlled indoor area free of power outlet may cause damage that the power cord, plug, and socket are missing parts please contact CyberPower technical support at www.cyberpower.com or call 1-877-297-6937. CAUTION! varies by model) Horizontal Installation Used (1 set) Vertical Installation Vertical Mounting Brackets (1 set) Used (1 set) (for Cord Retention Tray Ground Screw M4 X 6 (1 pcs) Documentation: User Manual DistriPbuotwioenr Unit User's Manual Product Registration Card Product Registration...
User Manual
Page 5
PDU Mounting Install the PDU using fasteners compatible with the rack. 3 For information on Cyberpower products, visit www.cyberpower.com Step 2 - Mounting bracket installation Install the screws (M4 X 6) in holes diagonal from each other. Installation Horizontal Installation (1U models only) Step 1 -
PDU Mounting Install the PDU using fasteners compatible with the rack. 3 For information on Cyberpower products, visit www.cyberpower.com Step 2 - Mounting bracket installation Install the screws (M4 X 6) in holes diagonal from each other. Installation Horizontal Installation (1U models only) Step 1 -
User Manual
Page 6
Mounting bracket installation Install the screws (M4 X 6) in holes diagonal from each other. Mounting bracket installation Attach the Vertical Mounting Brackets to the PDU with the rack. PDU Mounting Install the PDU using fasteners compatible with the rack. Vertical Installation with Brackets (0U models only) Step 1 - Vertical Installation with Brackets Step 1 - For information on Cyberpower products, visit www.cyberpower.com 4 Step 2 - PDU Mounting Install the PDU using fasteners compatible with the 4 supplied Bracket Mounting Screws (M4 X 6). Step 2 -
Mounting bracket installation Install the screws (M4 X 6) in holes diagonal from each other. Mounting bracket installation Attach the Vertical Mounting Brackets to the PDU with the rack. PDU Mounting Install the PDU using fasteners compatible with the rack. Vertical Installation with Brackets (0U models only) Step 1 - Vertical Installation with Brackets Step 1 - For information on Cyberpower products, visit www.cyberpower.com 4 Step 2 - PDU Mounting Install the PDU using fasteners compatible with the 4 supplied Bracket Mounting Screws (M4 X 6). Step 2 -
User Manual
Page 7
...Use the Cable Ties provided to fasten each power cord to the PDU with the 2 supplied Bracket Mounting Screws (M4 X 6). Vertical Installation with the screw on it. Meter Configuration ! Attach the Cord Retention Tray to the Cord Retention Tray. Tighten the Cord Retention Tray with Keyhole Mounts (0U Models...4 supplied Cord Retention Tray Mounting Screws (M3 X 6). PDU Mounting Align the the Keyhole Mounts to the Keyhole Slots on Cyberpower products, visit www.cyberpower.com Rotate the LED Meter 90 degrees, and insert back into place. Step 2 - Cord Retention Tray installation (...
...Use the Cable Ties provided to fasten each power cord to the PDU with the 2 supplied Bracket Mounting Screws (M4 X 6). Vertical Installation with the screw on it. Meter Configuration ! Attach the Cord Retention Tray to the Cord Retention Tray. Tighten the Cord Retention Tray with Keyhole Mounts (0U Models...4 supplied Cord Retention Tray Mounting Screws (M3 X 6). PDU Mounting Align the the Keyhole Mounts to the Keyhole Slots on Cyberpower products, visit www.cyberpower.com Rotate the LED Meter 90 degrees, and insert back into place. Step 2 - Cord Retention Tray installation (...
User Manual
Page 8
...-wire, grounded wall receptacle only. Troubleshooting Problem PDU Outlets do not provide power to any other type of wall receptacle may result in the Specifications section). Loose power cord Amperage displayed 1. Faulty breaker Solution Reset Breaker check if plug is important to an appropriate branch circuit/main with fuse or circuit breaker protection. If the problem remains contact tech support. Electrical Installation Step...
...-wire, grounded wall receptacle only. Troubleshooting Problem PDU Outlets do not provide power to any other type of wall receptacle may result in the Specifications section). Loose power cord Amperage displayed 1. Faulty breaker Solution Reset Breaker check if plug is important to an appropriate branch circuit/main with fuse or circuit breaker protection. If the problem remains contact tech support. Electrical Installation Step...
User Manual
Page 9
...Power Cord E. Circuit Breaker Back View AE B A. Cord Retention Tray Screw Holes Technical Specifications Model Name Input Voltage Max current Circuit Breaker Plug Type Power Cord Length Output Voltage Current Outlet Type Indicators LED Indicators Meter Readout Physical Dimension (WxDxH) Environmental Humidity Altitude Temperature Safety Approvals Certifications Warranty PDU15B8R PDU15B10R PDU15B12R PDU20B8R PDU20B10R...ETL (test followed UL 1363) RoHS Lifetime 7 For information on Cyberpower products, visit www.cyberpower.com Mounting Bracket B. External Site Ground CDE D.
...Power Cord E. Circuit Breaker Back View AE B A. Cord Retention Tray Screw Holes Technical Specifications Model Name Input Voltage Max current Circuit Breaker Plug Type Power Cord Length Output Voltage Current Outlet Type Indicators LED Indicators Meter Readout Physical Dimension (WxDxH) Environmental Humidity Altitude Temperature Safety Approvals Certifications Warranty PDU15B8R PDU15B10R PDU15B12R PDU20B8R PDU20B10R...ETL (test followed UL 1363) RoHS Lifetime 7 For information on Cyberpower products, visit www.cyberpower.com Mounting Bracket B. External Site Ground CDE D.
User Manual
Page 10
... Mounting Bracket B. Circuit Breaker C. External Site Ground CDE D. Cord Retention Tray Screw Holes Technical Specifications Model Name Input Voltage Max current Circuit Breaker Plug Type Power Cord Length Output Voltage Current Outlet Type Indicators LED Indicators Meter Readout Physical Dimension (WxDxH) Environmental Humidity Altitude Temperature Safety Approvals Certifications Warranty PDU15B2F8R ...,000ft Non-Operating 0ft to 50,000ft Operating 32F to 95F Non-Operating 5F to 113F ETL (test followed UL 1363) RoHS Lifetime For information on Cyberpower products, visit www...
... Mounting Bracket B. Circuit Breaker C. External Site Ground CDE D. Cord Retention Tray Screw Holes Technical Specifications Model Name Input Voltage Max current Circuit Breaker Plug Type Power Cord Length Output Voltage Current Outlet Type Indicators LED Indicators Meter Readout Physical Dimension (WxDxH) Environmental Humidity Altitude Temperature Safety Approvals Certifications Warranty PDU15B2F8R ...,000ft Non-Operating 0ft to 50,000ft Operating 32F to 95F Non-Operating 5F to 113F ETL (test followed UL 1363) RoHS Lifetime For information on Cyberpower products, visit www...
User Manual
Page 11
...B. AC Power Cord E. Cord Retention Tray Screw Holes Technical Specifications Model Name PDU15M2F8R PDU15M2F10R PDU15M2F12R PDU20M2F8R PDU20M2F10R PDU20M2F12R PDU20MT2F8R PDU20MT2F10R PDU20MT2F12R Input Voltage Max Current Circuit Breaker Plug Type Power Cord Length Output Voltage Current Outlet Type Fiters & Protection EMI/RFI Filtration Surge Suppression Indicators LED Indicators Meter Readout Physical Dimension (WxDxH)...Operating 0ft to 50,000ft Operating 32F to 95F Non-Operating 5F to 113F ETL (test followed UL 1363) RoHS Lifetime 9 For information on Cyberpower products, visit www...
...B. AC Power Cord E. Cord Retention Tray Screw Holes Technical Specifications Model Name PDU15M2F8R PDU15M2F10R PDU15M2F12R PDU20M2F8R PDU20M2F10R PDU20M2F12R PDU20MT2F8R PDU20MT2F10R PDU20MT2F12R Input Voltage Max Current Circuit Breaker Plug Type Power Cord Length Output Voltage Current Outlet Type Fiters & Protection EMI/RFI Filtration Surge Suppression Indicators LED Indicators Meter Readout Physical Dimension (WxDxH)...Operating 0ft to 50,000ft Operating 32F to 95F Non-Operating 5F to 113F ETL (test followed UL 1363) RoHS Lifetime 9 For information on Cyberpower products, visit www...
User Manual
Page 12
...Keyhole Mount Peg Screw Holes A E B D D E B A D Technical Specifications Model Name Input Voltage Max Current Circuit Breaker Plug Type Power Cord Length Output Voltage Current Outlet Type Indicators LED Indicators Meter Readout Physical Dimension (WxDxH) Environmental Humidity Altitude Temperature Safety Approvals Certifications Warranty PDU15BV14F PDU15BV16F PDU15BV20F PDU15BV28F ... 32F to 95F Non-Operating 5F to 113F ETL (test followed UL 1363) RoHS Lifetime For information on Cyberpower products, visit www.cyberpower.com 10 Basic Series (0U) Product Features Front View Back View...
...Keyhole Mount Peg Screw Holes A E B D D E B A D Technical Specifications Model Name Input Voltage Max Current Circuit Breaker Plug Type Power Cord Length Output Voltage Current Outlet Type Indicators LED Indicators Meter Readout Physical Dimension (WxDxH) Environmental Humidity Altitude Temperature Safety Approvals Certifications Warranty PDU15BV14F PDU15BV16F PDU15BV20F PDU15BV28F ... 32F to 95F Non-Operating 5F to 113F ETL (test followed UL 1363) RoHS Lifetime For information on Cyberpower products, visit www.cyberpower.com 10 Basic Series (0U) Product Features Front View Back View...
User Manual
Page 13
...Cord Tray Screws D Holes E. Keyhole Mount Peg Screw Holes A E B D F D E B A D Technical Specifications Model Name PDU15MV20F PDU15MV26F PDU15MV32F PDU20MV20F PDU20MV26F PDU20MV32F PDU20MTV20F PDU20MTV26F PDU20MTV32F Input Voltage Max Current Circuit Breaker Plug Type Power Cord Length Output Voltage Current Outlet Type Indicators LED Indicators Meter Readout Physical Dimension...Non-Operating 5F to 113F ETL (test followed UL 1363) RoHS Lifetime 11 For information on Cyberpower products, visit www.cyberpower.com Bracket Screw Hole B. AC Power Cord A B. Front Outlets F.
...Cord Tray Screws D Holes E. Keyhole Mount Peg Screw Holes A E B D F D E B A D Technical Specifications Model Name PDU15MV20F PDU15MV26F PDU15MV32F PDU20MV20F PDU20MV26F PDU20MV32F PDU20MTV20F PDU20MTV26F PDU20MTV32F Input Voltage Max Current Circuit Breaker Plug Type Power Cord Length Output Voltage Current Outlet Type Indicators LED Indicators Meter Readout Physical Dimension...Non-Operating 5F to 113F ETL (test followed UL 1363) RoHS Lifetime 11 For information on Cyberpower products, visit www.cyberpower.com Bracket Screw Hole B. AC Power Cord A B. Front Outlets F.
User Manual
Page 14
... the Product (purchase receipt showing price paid is unable to or decides not to repair or replace the Product (if defective) within a reasonable time, CyberPower will inspect and examine the Product. This Warranty is defective in the Product under "Support". How Do You Get Service? 1. When you should return the Product for instructions. 2. Pack and ship the...
... the Product (purchase receipt showing price paid is unable to or decides not to repair or replace the Product (if defective) within a reasonable time, CyberPower will inspect and examine the Product. This Warranty is defective in the Product under "Support". How Do You Get Service? 1. When you should return the Product for instructions. 2. Pack and ship the...
User Manual
Page 15
...? 1. Any such installation voids the Limited Warranty. 3. The Product must have been used properly in a suitable and proper environment and in conformance with any adapters or other connectors. 2. The sole and exclusive remedies of any license, instruction manual, or warnings provided with the Product, such as a result of the failure or the restoration of data or records, or...
...? 1. Any such installation voids the Limited Warranty. 3. The Product must have been used properly in a suitable and proper environment and in conformance with any adapters or other connectors. 2. The sole and exclusive remedies of any license, instruction manual, or warnings provided with the Product, such as a result of the failure or the restoration of data or records, or...
Datasheet
Page 1
... • Basic PDU • Switch-Free Design • Industrial-Grade Metal Housing • Lifetime Warranty A Lifetime Warranty ensures that this unit has a rugged, industrial-grade metal housing and a 15-foot AC power cord. It distributes power to equipment. Designed for datacenters and... includes a cord retention tray and is free of defects in design, assembly, material and workmanship. The CyberPower 10-outlet rack mount basic power distribution unit (PDU20B10R) provides 120V 20A output. PDU20B10R Basic PDU Engineered to distribute UPS, generator or utility AC power to 10 NEMA...
... • Basic PDU • Switch-Free Design • Industrial-Grade Metal Housing • Lifetime Warranty A Lifetime Warranty ensures that this unit has a rugged, industrial-grade metal housing and a 15-foot AC power cord. It distributes power to equipment. Designed for datacenters and... includes a cord retention tray and is free of defects in design, assembly, material and workmanship. The CyberPower 10-outlet rack mount basic power distribution unit (PDU20B10R) provides 120V 20A output. PDU20B10R Basic PDU Engineered to distribute UPS, generator or utility AC power to 10 NEMA...
Datasheet
Page 2
... INPUT Voltage Current Frequency Plug Type Plug Style Cord Length OUTPUT Nominal Output Voltage Outlets - Rear Overload Protection PHYSICAL Rack Size Form Factors Supported Cord Retention Organizers External Site Ground Pin Adjustable Mounting Brackets Dimensions (WxHxD) (in.) ...Installation Supported Yes Yes 2 sets (L-short, L-long) 17.5 x 1.75 x 1.5 4.5 32°F to 95°F / 0°C to 35°C 0% - 95% non-condensing 5°F to 113°F / -15°C to change, without prior notice, product offerings or specifications. All rights reserved. Total Outlet Type Outlets - CyberPower...
... INPUT Voltage Current Frequency Plug Type Plug Style Cord Length OUTPUT Nominal Output Voltage Outlets - Rear Overload Protection PHYSICAL Rack Size Form Factors Supported Cord Retention Organizers External Site Ground Pin Adjustable Mounting Brackets Dimensions (WxHxD) (in.) ...Installation Supported Yes Yes 2 sets (L-short, L-long) 17.5 x 1.75 x 1.5 4.5 32°F to 95°F / 0°C to 35°C 0% - 95% non-condensing 5°F to 113°F / -15°C to change, without prior notice, product offerings or specifications. All rights reserved. Total Outlet Type Outlets - CyberPower...