Planning Guides
Page 1
...SUPPLY PRESSURE REQUIREMENTS* Gas Type Manifold Pressure Minimum Gas Supply Pressure Natural Gas 5" Water Column 6" Water Column Propane (LP) 10" Water Column 11" Water Column * Maximum gas supply pressure for further information. • This appliance must ...building department for all governing codes and ordinances during planning and installation. When installing a backguard, use only Dacor model numbers AEB3009 (DRT304S), AEB3609 or AEB3612 (DRT366S). to combustible rear wall COOKTOP WIDTH (A) DRT304S 29 7/8" (75.9 cm) DRT366S 35 7/8" (91.1 cm) 28 1/8" (71.4 cm) 25 ...
...SUPPLY PRESSURE REQUIREMENTS* Gas Type Manifold Pressure Minimum Gas Supply Pressure Natural Gas 5" Water Column 6" Water Column Propane (LP) 10" Water Column 11" Water Column * Maximum gas supply pressure for further information. • This appliance must ...building department for all governing codes and ordinances during planning and installation. When installing a backguard, use only Dacor model numbers AEB3009 (DRT304S), AEB3609 or AEB3612 (DRT366S). to combustible rear wall COOKTOP WIDTH (A) DRT304S 29 7/8" (75.9 cm) DRT366S 35 7/8" (91.1 cm) 28 1/8" (71.4 cm) 25 ...
Installation Instructions
Page 5
...off valve to regulator from bottom or rear of this page is for the gas service being provided (natural gas or LP gas). GAS SUPPLY PRESSURE REQUIREMENTS* Gas Type Manifold Pressure Minimum Gas Supply Pressure Natural Gas 5" Water Column 6" Water Column Propane... 60 Hz. See the inside cover for the purpose of installation. Also, if operating the cooktop at an altitude above countertop 7 3/4" (19.7 cm) A COOKTOP WIDTH (A) DRT304S 29 7/8" (75.9 cm) DRT366S 35 7/8" (91.1 cm) 4" (10.2 cm) Power cord 32" (81.3 cm) long 3/4" gas inlet, connects to the cooktop ...
...off valve to regulator from bottom or rear of this page is for the gas service being provided (natural gas or LP gas). GAS SUPPLY PRESSURE REQUIREMENTS* Gas Type Manifold Pressure Minimum Gas Supply Pressure Natural Gas 5" Water Column 6" Water Column Propane... 60 Hz. See the inside cover for the purpose of installation. Also, if operating the cooktop at an altitude above countertop 7 3/4" (19.7 cm) A COOKTOP WIDTH (A) DRT304S 29 7/8" (75.9 cm) DRT366S 35 7/8" (91.1 cm) 4" (10.2 cm) Power cord 32" (81.3 cm) long 3/4" gas inlet, connects to the cooktop ...
Installation Instructions
Page 10
... 102590) Standard burner ring, large (PN 102591) SimmerSear burner ring (PN 102588) SimmerSear inner burner cap (PN 102585) SimmerSear outer burner cap (PN 102586) Quantity DRT304S 3 1 none none 2 1 1 2 2 1 1 1 Quantity DRT366S 4 2 1 2 none 2 2 2 2 2 2 2 8 The customer must be performed at the customer's expense. 1. The...overtighten the bolts. Secure the cooktop to safely install it only after the cooktop is heavy. gas (PN 62834) or LP (PN 72980) • Dacor Stainless Steel Cleaner (PN A302) • Literature kit WARNING • To prevent damage to permanently seal the cooktop ...
... 102590) Standard burner ring, large (PN 102591) SimmerSear burner ring (PN 102588) SimmerSear inner burner cap (PN 102585) SimmerSear outer burner cap (PN 102586) Quantity DRT304S 3 1 none none 2 1 1 2 2 1 1 1 Quantity DRT366S 4 2 1 2 none 2 2 2 2 2 2 2 8 The customer must be performed at the customer's expense. 1. The...overtighten the bolts. Secure the cooktop to safely install it only after the cooktop is heavy. gas (PN 62834) or LP (PN 72980) • Dacor Stainless Steel Cleaner (PN A302) • Literature kit WARNING • To prevent damage to permanently seal the cooktop ...
Installation Instructions
Page 11
... the regulator must have a wider space between the large flame icon and the simmer icon than 1/2 p.s.i. (3.5 kPa). • For LP gas installations, the LP gas tank must never exceed 1/2 pounds per square inch (psi) or 3.5 kPa. • Do not install or use the cooktop ... column (249 Pa) above the specified manifold pressure. For best performance, minimize gas pressure loss by a licensed plumber or gas fitter. 1. Control Panel DRT304S B A B B A SimmerSear Burner Knob Layout B Standard Burner Knob Layout Gas Line Connection warning • Verify that the arrow on the regulator points...
... the regulator must have a wider space between the large flame icon and the simmer icon than 1/2 p.s.i. (3.5 kPa). • For LP gas installations, the LP gas tank must never exceed 1/2 pounds per square inch (psi) or 3.5 kPa. • Do not install or use the cooktop ... column (249 Pa) above the specified manifold pressure. For best performance, minimize gas pressure loss by a licensed plumber or gas fitter. 1. Control Panel DRT304S B A B B A SimmerSear Burner Knob Layout B Standard Burner Knob Layout Gas Line Connection warning • Verify that the arrow on the regulator points...