Installation Instructions Downdraft Raised Vent Models: ERV36-ER, ERV48-ER Part No. 103106 Rev. See the installation instructions for the particular appliance model being installed to determine suitability. H Use these downdraft raised vents only with approved Dacor ® appliances.
Installation Instructions Downdraft Raised Vent Models: ERV36-ER, ERV48-ER Part No. 103106 Rev. See the installation instructions for the particular appliance model being installed to determine suitability. H Use these downdraft raised vents only with approved Dacor ® appliances.
Installation Instructions
Page 2
... Cooking and Liquid Heating Appliances, and UL 507 electric fans. Model Identification: ERV36-ER = 36-inch wide raised vent ERV48-ER = 48-inch wide raised vent Tested in accordance with the latest edition of the appliance ready. For repairs to Dacor appliances under warranty only) Phone: (877) 337-3226 (U.S.A. Friday 6:00 a.m to change without...
... Cooking and Liquid Heating Appliances, and UL 507 electric fans. Model Identification: ERV36-ER = 36-inch wide raised vent ERV48-ER = 48-inch wide raised vent Tested in accordance with the latest edition of the appliance ready. For repairs to Dacor appliances under warranty only) Phone: (877) 337-3226 (U.S.A. Friday 6:00 a.m to change without...
Installation Instructions
Page 5
..." (71 mm) Top cap with vent down 1 15/16" (49 mm) 2 9/16" (65 mm) Vent shown in raised position 10" (254 mm) Model Number ERV36-ER ERV48-ER Top Cap Width (A) 36" (914 mm) 48" (1219 mm) Chassis Width (B) 33 3/8" (848 mm) 43 3/8" (1102 mm) Tolerances: ±1/16", (±1.6 mm) unless otherwise stated...
..." (71 mm) Top cap with vent down 1 15/16" (49 mm) 2 9/16" (65 mm) Vent shown in raised position 10" (254 mm) Model Number ERV36-ER ERV48-ER Top Cap Width (A) 36" (914 mm) 48" (1219 mm) Chassis Width (B) 33 3/8" (848 mm) 43 3/8" (1102 mm) Tolerances: ±1/16", (±1.6 mm) unless otherwise stated...
Installation Instructions
Page 8
...rely on duct tape alone to make the connection. To prevent back-drafts, a damper at zero inches static pressure. You must install one of the Dacor remote or in the floor to allow the transition and/or duct work to pass through the back, the bottom or either side by the... raised vent. the customer must be sure to duct air outside . Only transition to seal duct joints. APPROVED DACOR BLOWERS FOR USE WITH MODEL ERV36-ER AND ERV48-ER RAISED VENTS Model Number REMP3 REMP16 ILHSF8 ILHSF10 Rating* 600 CFM 1000 CFM 600 CFM 1100 CFM plied ATD2 transition to connect...
...rely on duct tape alone to make the connection. To prevent back-drafts, a damper at zero inches static pressure. You must install one of the Dacor remote or in the floor to allow the transition and/or duct work to pass through the back, the bottom or either side by the... raised vent. the customer must be sure to duct air outside . Only transition to seal duct joints. APPROVED DACOR BLOWERS FOR USE WITH MODEL ERV36-ER AND ERV48-ER RAISED VENTS Model Number REMP3 REMP16 ILHSF8 ILHSF10 Rating* 600 CFM 1000 CFM 600 CFM 1100 CFM plied ATD2 transition to connect...
Use & Care Manuals
Page 1
Model ERV36 shown. E Ta b l e o f C o n t e n t s Important Safety Instructions 1 Operating Your Raised Vent 3 Care and Cleaning 4 Before You Call for Service 5 Warranty and Service 6 Notes 7 Part No. 103107 Rev. Use and Care Manual Downdraft Raised Vent Models: ERV30, ERV36, ERV36-ER, ERV48, ERV48-ER, PRV30, PRV36, PRV46 Style varies.
Model ERV36 shown. E Ta b l e o f C o n t e n t s Important Safety Instructions 1 Operating Your Raised Vent 3 Care and Cleaning 4 Before You Call for Service 5 Warranty and Service 6 Notes 7 Part No. 103107 Rev. Use and Care Manual Downdraft Raised Vent Models: ERV30, ERV36, ERV36-ER, ERV48, ERV48-ER, PRV30, PRV36, PRV46 Style varies.