Planning Guides
Page 1
... not connect the ground wire to change without notice. www.dacor.com Phone: (800) 7933-0.1093 Model No. All leads are not approved for exact specifications. These cooktops are copper. Document # PG03-001 MET304 and METB365-1 30 Inch and 36 Inch Wide, Discovery™ Electric Cooktops Revised 10/01/11 Page 1/3 PLANNING GUIDE Product tolerances: ±...
... not connect the ground wire to change without notice. www.dacor.com Phone: (800) 7933-0.1093 Model No. All leads are not approved for exact specifications. These cooktops are copper. Document # PG03-001 MET304 and METB365-1 30 Inch and 36 Inch Wide, Discovery™ Electric Cooktops Revised 10/01/11 Page 1/3 PLANNING GUIDE Product tolerances: ±...
Planning Guides
Page 2
... Under Counter Clearance (Width) 28 3/4" (73.0 cm) 34 3/4" (88.3 cm) Rear wall 6" (15.2 cm) min. www.dacor.com Phone: (800) 7933-0.2093 Document # PG03-001 MET304 and METB365-1 30 Inch and 36 Inch Wide, Discovery Electric Cooktops All tolerances: +1/16", -0, (+1.6 mm, -0) unless otherwise stated Revised 10/01/11 Page 2/3 PLANNING GUIDE Allow a minimum of 6 inches...
... Under Counter Clearance (Width) 28 3/4" (73.0 cm) 34 3/4" (88.3 cm) Rear wall 6" (15.2 cm) min. www.dacor.com Phone: (800) 7933-0.2093 Document # PG03-001 MET304 and METB365-1 30 Inch and 36 Inch Wide, Discovery Electric Cooktops All tolerances: +1/16", -0, (+1.6 mm, -0) unless otherwise stated Revised 10/01/11 Page 2/3 PLANNING GUIDE Allow a minimum of 6 inches...
Planning Guides
Page 3
... Rear wall C 19 3/4" (50.2 cm) Cabinet face 1" min. (2.5 cm) 6" (15.2 cm) min. www.dacor.com Phone: (800) 7933-0.3093 from mounting surface to change without notice. Document # PG03-001 MET304 and METB365-1 30 Inch and 36 Inch Wide, Discovery Electric Cooktops All tolerances: +1/16", -0, (+1.6 mm, -0) unless otherwise stated Revised 10/01/11 Page 3/3 PLANNING GUIDE...
... Rear wall C 19 3/4" (50.2 cm) Cabinet face 1" min. (2.5 cm) 6" (15.2 cm) min. www.dacor.com Phone: (800) 7933-0.3093 from mounting surface to change without notice. Document # PG03-001 MET304 and METB365-1 30 Inch and 36 Inch Wide, Discovery Electric Cooktops All tolerances: +1/16", -0, (+1.6 mm, -0) unless otherwise stated Revised 10/01/11 Page 3/3 PLANNING GUIDE...
Installation Instructions
Page 5
... 1/4" * (768 mm) 4" (102 mm) Chassis height 19 3/8" 21 1/4" * (495 mm) (540 mm) 28 3/8" (721 mm) 36 1/4" * (921 mm) 4" (102 mm) Chassis height Models ETT304-1, MET304 19 3/8" 21 1/4" * (495 mm) (540 mm) 34 ... by the manufacturer is 8 AWG. A copy of the unit) for exact specifications. Model ETT304-1 ETT365-2 MET304 METB365-1 Dedicated Circuit Required 240 Vac, 60 Hz. 3 wire* 40 Amp. 240 Vac, 60 Hz. 3 wire*...listed on the bottom of the standard may be accessible when the cooktop is provided with the National Electric Code ANSI/NFPA 70 (latest revision) and local codes and ordinances...
... 1/4" * (768 mm) 4" (102 mm) Chassis height 19 3/8" 21 1/4" * (495 mm) (540 mm) 28 3/8" (721 mm) 36 1/4" * (921 mm) 4" (102 mm) Chassis height Models ETT304-1, MET304 19 3/8" 21 1/4" * (495 mm) (540 mm) 34 ... by the manufacturer is 8 AWG. A copy of the unit) for exact specifications. Model ETT304-1 ETT365-2 MET304 METB365-1 Dedicated Circuit Required 240 Vac, 60 Hz. 3 wire* 40 Amp. 240 Vac, 60 Hz. 3 wire*...listed on the bottom of the standard may be accessible when the cooktop is provided with the National Electric Code ANSI/NFPA 70 (latest revision) and local codes and ordinances...
Installation Instructions
Page 6
...electrical location is also required for inspection and service. A vent hood should be installed. If installing the cooktop with a raised vent, install only the following approved Dacor model numbers: Cooktop Models ETT304-1 MET304 Approved Raised Vent Models ERV30, PRV30 or RV30 ETT365-2 METB365-1... the selected location. Do not lengthen the wiring. See below the cooktop. Contact your local building department for cutout requirements. Minimum Under Counter Clearance (Width) 30 1/2" (775 mm) 36 1/2" (927 mm) Under Counter Clearance - Proper under-cabinet clearance is...
...electrical location is also required for inspection and service. A vent hood should be installed. If installing the cooktop with a raised vent, install only the following approved Dacor model numbers: Cooktop Models ETT304-1 MET304 Approved Raised Vent Models ERV30, PRV30 or RV30 ETT365-2 METB365-1... the selected location. Do not lengthen the wiring. See below the cooktop. Contact your local building department for cutout requirements. Minimum Under Counter Clearance (Width) 30 1/2" (775 mm) 36 1/2" (927 mm) Under Counter Clearance - Proper under-cabinet clearance is...