www.dacor.com flange 3/8" flange extension length (1.0 cm) Rear Flange and Channel Dimensions (Side View) Phone: (800) 793-0093 7.12 RNIVS1 & RNIVSR1 10 23/32" (27.69 ....82 cm) Top Centerline Dimensions 6" 6" (15.24 cm) CLCL (15.24 cm) 6 3/16" 5 3/4" (15.72 cm) (14.54 cm) RNIVS1 & RNIVSR1 Dimensions Top Centerline Dimensions RNIVS2 & RNIVSR2 30 1/4" (76.84 cm) 31 7/16" (79.83 cm) .40 3/8" Rear Flange Extension flange (13.0/8c"m) 8 7/8" (22.5 cm) 3/8" (1.0 cm) 3/8" Rear Flange Extension Detail 18...
www.dacor.com flange 3/8" flange extension length (1.0 cm) Rear Flange and Channel Dimensions (Side View) Phone: (800) 793-0093 7.12 RNIVS1 & RNIVSR1 10 23/32" (27.69 ....82 cm) Top Centerline Dimensions 6" 6" (15.24 cm) CLCL (15.24 cm) 6 3/16" 5 3/4" (15.72 cm) (14.54 cm) RNIVS1 & RNIVSR1 Dimensions Top Centerline Dimensions RNIVS2 & RNIVSR2 30 1/4" (76.84 cm) 31 7/16" (79.83 cm) .40 3/8" Rear Flange Extension flange (13.0/8c"m) 8 7/8" (22.5 cm) 3/8" (1.0 cm) 3/8" Rear Flange Extension Detail 18...
Installation Instructions
Page 1
A APPROVED FOR USE WITH ALL DACOR® RANGES AND COOKTOPS. TESTED IN ACCORDANCE WITH THE LATEST EDITION OF ANSI/UL 507 STANDARD FOR ELECTRIC FANS AND CAN/CSA-C22.2 NO. 115 STANDARD FOR FANS AND VENTILATORS. Installation Instructions Renaissance® Integrated Ventilation Systems Models RNIVS1, RNIVS2, RNIVSR1, and RNIVSR2 Part No. 109408 Rev.
A APPROVED FOR USE WITH ALL DACOR® RANGES AND COOKTOPS. TESTED IN ACCORDANCE WITH THE LATEST EDITION OF ANSI/UL 507 STANDARD FOR ELECTRIC FANS AND CAN/CSA-C22.2 NO. 115 STANDARD FOR FANS AND VENTILATORS. Installation Instructions Renaissance® Integrated Ventilation Systems Models RNIVS1, RNIVS2, RNIVSR1, and RNIVSR2 Part No. 109408 Rev.
Installation Instructions
Page 6
... Hz., 15 Amp. Correct installation of the in-line blower or the remote blower Fan Rating** RNIVS1: 600 CFM RNIVS2: 1200 CFM RNIVSR1 and RNIVSR2: Depends on the unit for reference only. Dacor Blower Models Used in -line blower or remote blower specifications * Electrical specifications are provided for exact specifications. ** Rated at...
... Hz., 15 Amp. Correct installation of the in-line blower or the remote blower Fan Rating** RNIVS1: 600 CFM RNIVS2: 1200 CFM RNIVSR1 and RNIVSR2: Depends on the unit for reference only. Dacor Blower Models Used in -line blower or remote blower specifications * Electrical specifications are provided for exact specifications. ** Rated at...
Installation Instructions
Page 11
... stripper Junction box Jigsaw 8" Ducting Foil tape Sheet metal screws 18 AWG Wire or 3-prong power cord Hood Liner Kit Dacor Liner Kit # RNIHL30/36/48 Sheet metal screws Dual to your RNIVS. Preparation and Setup Parts List A RNIVS B... C Baffle filter and hardware (2) E Dimmable LED light bulbs (2) Features C Filters E LED Lights A RNIVS1 2 RNIVS2 3 2 2 pictures vary by model F Light replacement tool (1) B G Literature (2) C H Dacor Stainless Cleaning Creme (1) E F H G STAINLESS STEEL CLEANER Necessary Tools and Hardware Optional Accessories Please make sure these tools...
... stripper Junction box Jigsaw 8" Ducting Foil tape Sheet metal screws 18 AWG Wire or 3-prong power cord Hood Liner Kit Dacor Liner Kit # RNIHL30/36/48 Sheet metal screws Dual to your RNIVS. Preparation and Setup Parts List A RNIVS B... C Baffle filter and hardware (2) E Dimmable LED light bulbs (2) Features C Filters E LED Lights A RNIVS1 2 RNIVS2 3 2 2 pictures vary by model F Light replacement tool (1) B G Literature (2) C H Dacor Stainless Cleaning Creme (1) E F H G STAINLESS STEEL CLEANER Necessary Tools and Hardware Optional Accessories Please make sure these tools...
Installation Instructions
Page 12
...All tolerances are minimum clearances, unless otherwise noted. • All contact surfaces between the RNIVS and any custom hood canopy using a Dacor RNIHL Series Stainless Steel Hood Liner must be a minimum of 30" (76.2 cm) above the countertop cooking surface. Minimum Height ... given are +1/16", -0" (+.16, -0 cm) Minimum Width of E: Upper Cabinet Cutout & Appliance Width Models E RNIVS1, RNIVSR1 30 inches (76.2 cm) RNIVS2, RNIVSR2 36 inches (91.5 cm) • An RNIVS installed inside any cabinetry or walls must be sturdy, solid, and at right angles. The minimum specified...
...All tolerances are minimum clearances, unless otherwise noted. • All contact surfaces between the RNIVS and any custom hood canopy using a Dacor RNIHL Series Stainless Steel Hood Liner must be a minimum of 30" (76.2 cm) above the countertop cooking surface. Minimum Height ... given are +1/16", -0" (+.16, -0 cm) Minimum Width of E: Upper Cabinet Cutout & Appliance Width Models E RNIVS1, RNIVSR1 30 inches (76.2 cm) RNIVS2, RNIVSR2 36 inches (91.5 cm) • An RNIVS installed inside any cabinetry or walls must be sturdy, solid, and at right angles. The minimum specified...
Installation Instructions
Page 27
Wire Diagrams RNIVS2 & RNIVSR2 CONNECT TO 120V 60Hz 15A POWER SUPPLY GW B HOOD HOOD LIGHT 75W LIGHT 75W WIRING DIAGRAM RNIVS2, RNIVSR2 W LAMP DIMMER FAN SWITCH B G W RNIVSR2 DOES NOT HAVE A FAN IN THE UNIT; FOR CONNECTION TO REMOTE BLOWER P/N: ILHSF -8/10 OR REMP -3/16 DACOR P/N: 109391 REV A 26 IT IS FOR A REMOTE BLOWER ONLY B LIGHT B LIGHT B FAN B FAN FOR CONNECTION TO ARLC/ARSC /ARSLC BG W FAN MOTOR FAN MOTOR B W G CAUTION: DISCONNECT POWER SUPPLY AT THE FUSE BOX BEFORE SERVICING THIS EQUIPMENT.
Wire Diagrams RNIVS2 & RNIVSR2 CONNECT TO 120V 60Hz 15A POWER SUPPLY GW B HOOD HOOD LIGHT 75W LIGHT 75W WIRING DIAGRAM RNIVS2, RNIVSR2 W LAMP DIMMER FAN SWITCH B G W RNIVSR2 DOES NOT HAVE A FAN IN THE UNIT; FOR CONNECTION TO REMOTE BLOWER P/N: ILHSF -8/10 OR REMP -3/16 DACOR P/N: 109391 REV A 26 IT IS FOR A REMOTE BLOWER ONLY B LIGHT B LIGHT B FAN B FAN FOR CONNECTION TO ARLC/ARSC /ARSLC BG W FAN MOTOR FAN MOTOR B W G CAUTION: DISCONNECT POWER SUPPLY AT THE FUSE BOX BEFORE SERVICING THIS EQUIPMENT.