Planning Guide
Page 1
... Models RNR30NIS and RNR30NIFS are not compatible with a downdraft vent. www.dacor.com Phone: (800) 793-0093 Available Backguard Part Number Description Compatibility ADRB30E06 6 Inch Standard on models RNR30NS, RNR30NFS, Optional on outside of door RNR30NIFS[-C]* Built-in/Slide-in...steel side panels (removable) Dimension 35" (88.9 cm) to depth dimensions below when installing a backguard on models RNR30NS and RNR30NFS are compatible with Dacor downdraft vent model ERV3015 only. *See table for compatibility OVERALL DEPTH DIMENSIONS - A backguard may be installed in ...
... Models RNR30NIS and RNR30NIFS are not compatible with a downdraft vent. www.dacor.com Phone: (800) 793-0093 Available Backguard Part Number Description Compatibility ADRB30E06 6 Inch Standard on models RNR30NS, RNR30NFS, Optional on outside of door RNR30NIFS[-C]* Built-in/Slide-in...steel side panels (removable) Dimension 35" (88.9 cm) to depth dimensions below when installing a backguard on models RNR30NS and RNR30NFS are compatible with Dacor downdraft vent model ERV3015 only. *See table for compatibility OVERALL DEPTH DIMENSIONS - A backguard may be installed in ...
Planning Guide
Page 2
... Countertop ERV3015 downdraft 3/8" min. (1.0 cm) space required behind ERV3015 chassis to the above is for reference only. www.dacor.com Phone: (800) 793-0093 For slide-in ranges installed in Canada and U.S.A., where local codes permit. DOWNDRAFT ERV3015... WITH SLIDE-IN, SELFRIMMING INSTALLATION WITH 3" SIDE PANELS REMOVED AND ATKR30SR TRIM KIT (REQUIRED) INSTALLED Factory Wiring Model RNR30NS, RNR30NFS RNR30NS-C, RNR30NFS-C RNR30NIS, RNR30NIFS RNR30NIS-C, RNR30NIFS-C Factory Electrical Connection Power cord not installed. DOWNDRAFT ERV3015 WITH SLIDE-IN, SELFRIMMING ...
... Countertop ERV3015 downdraft 3/8" min. (1.0 cm) space required behind ERV3015 chassis to the above is for reference only. www.dacor.com Phone: (800) 793-0093 For slide-in ranges installed in Canada and U.S.A., where local codes permit. DOWNDRAFT ERV3015... WITH SLIDE-IN, SELFRIMMING INSTALLATION WITH 3" SIDE PANELS REMOVED AND ATKR30SR TRIM KIT (REQUIRED) INSTALLED Factory Wiring Model RNR30NS, RNR30NFS RNR30NS-C, RNR30NFS-C RNR30NIS, RNR30NIFS RNR30NIS-C, RNR30NIFS-C Factory Electrical Connection Power cord not installed. DOWNDRAFT ERV3015 WITH SLIDE-IN, SELFRIMMING ...
Planning Guide
Page 3
... junction box/receptacle must be provided directly above range (both sides). All specifications subject to the rear wall. www.dacor.com Phone: (800) 793-0093 It is highly recommended. FREESTANDING INSTALLATION CABINET CUTOUT DIMENSIONS - See Product Dimensions. ...3Consult local code and following page for rear wall surface requirements. to be sealed. RNR30NS, RNR30NFS, RNR30NIS, RNR30NIFS Document # PG05-011 Renaissance 30" Wide Electric Induction Range Revised 01/28/15 Page 3/5 PLANNING GUIDE...
... junction box/receptacle must be provided directly above range (both sides). All specifications subject to the rear wall. www.dacor.com Phone: (800) 793-0093 It is highly recommended. FREESTANDING INSTALLATION CABINET CUTOUT DIMENSIONS - See Product Dimensions. ...3Consult local code and following page for rear wall surface requirements. to be sealed. RNR30NS, RNR30NFS, RNR30NIS, RNR30NIFS Document # PG05-011 Renaissance 30" Wide Electric Induction Range Revised 01/28/15 Page 3/5 PLANNING GUIDE...
Planning Guide
Page 4
... 23 3/8" All specifications subject to 36 7/8" (93.7 cm) Countertop height: 34 3/4" (88.3 cm) min. 36 7/8" (93.7 cm) max. www.dacor.com Phone: (800) 793-0093 Countertop thickness: 1 5/8" (4.1 cm) max. ■■ The self-rimming installation of the RNR30NI[F]S range creates a ... (Models RNR30NIS and RNR30NIFS Only) All tolerances +1/16" (+1.6 mm), -0 unless otherwise noted. Countertop 1 5/8 (41.1 cm) max. RNR30NS, RNR30NFS, RNR30NIS, RNR30NIFS Document # PG05-011 Renaissance 30" Wide Electric Induction Range Revised 01/28/15 Page 4/5 PLANNING GUIDE Cabinet Cutouts ...
... 23 3/8" All specifications subject to 36 7/8" (93.7 cm) Countertop height: 34 3/4" (88.3 cm) min. 36 7/8" (93.7 cm) max. www.dacor.com Phone: (800) 793-0093 Countertop thickness: 1 5/8" (4.1 cm) max. ■■ The self-rimming installation of the RNR30NI[F]S range creates a ... (Models RNR30NIS and RNR30NIFS Only) All tolerances +1/16" (+1.6 mm), -0 unless otherwise noted. Countertop 1 5/8 (41.1 cm) max. RNR30NS, RNR30NFS, RNR30NIS, RNR30NIFS Document # PG05-011 Renaissance 30" Wide Electric Induction Range Revised 01/28/15 Page 4/5 PLANNING GUIDE Cabinet Cutouts ...
Planning Guide
Page 5
.... (1.0 cm) Rear wall or countertop overhang countertop edge 27 1/2" (69.9 cm) downdraft vent opening 2 5/8" (6.7 cm) Max. REQUIRED CABINET DEPTH: 26 3/8" 2 To create a "built-in back. RNR30NS, RNR30NFS, RNR30NIS, RNR30NIFS Document # PG05-011 Renaissance 30" Wide Electric Induction Range Revised 01/28/15 Page 5/5 PLANNING GUIDE Cabinet Cutouts for downdraft vent installation... (see diagrams) 34 3/4" (88.3 cm) to change without notice. On installations with the width at the notches remaining 30 1/16". Countertop 1 5/8 (41.1 cm) max. www.dacor.com Phone: (800) 793-0093
.... (1.0 cm) Rear wall or countertop overhang countertop edge 27 1/2" (69.9 cm) downdraft vent opening 2 5/8" (6.7 cm) Max. REQUIRED CABINET DEPTH: 26 3/8" 2 To create a "built-in back. RNR30NS, RNR30NFS, RNR30NIS, RNR30NIFS Document # PG05-011 Renaissance 30" Wide Electric Induction Range Revised 01/28/15 Page 5/5 PLANNING GUIDE Cabinet Cutouts for downdraft vent installation... (see diagrams) 34 3/4" (88.3 cm) to change without notice. On installations with the width at the notches remaining 30 1/16". Countertop 1 5/8 (41.1 cm) max. www.dacor.com Phone: (800) 793-0093
Installation Instructions
Page 6
Models RNR30NIx and RNR30NIFx are not compatible with Dacor downdraft vent model ERV3015 only. Add an additional 1/16 inch to the depth dimensions above when installing a backguard on models RNR30NIx, RNR30NIFx **Models RNR30NIx ....2 cm) backguard* External handle shown, some models have integral handle (see inside cover) Product width: 29 15/16" (76.0 cm) RNR30NI[F]S: 3/8" (9.5 mm) thick top trim RNR30N[F]S: full stainless steel side panels RNR30NI[F]S: 3" (7.6 cm) partial stainless steel side panels (removable) 35" (88.9 cm) to 37" (94.0 cm) Dimension A C D RNR30Nx RNR30NFx 46 1/4" (...
Models RNR30NIx and RNR30NIFx are not compatible with Dacor downdraft vent model ERV3015 only. Add an additional 1/16 inch to the depth dimensions above when installing a backguard on models RNR30NIx, RNR30NIFx **Models RNR30NIx ....2 cm) backguard* External handle shown, some models have integral handle (see inside cover) Product width: 29 15/16" (76.0 cm) RNR30NI[F]S: 3/8" (9.5 mm) thick top trim RNR30N[F]S: full stainless steel side panels RNR30NI[F]S: 3" (7.6 cm) partial stainless steel side panels (removable) 35" (88.9 cm) to 37" (94.0 cm) Dimension A C D RNR30Nx RNR30NFx 46 1/4" (...
Use Care Manual
Page 8
...the magnetic induction cooking element. Below each cooking zone is totally different from hot pots or pans. Cooktop surface Cooking zone Style varies, model RNR30NS shown Cooktop Control Panel •A ON/OFF Key: Turns on the indicated cooking zone. •B Power Light: Turns on when the indicated...hard is lost heating the cooktop itself. At higher power settings, the induction element will stay on the keys can draw at a higher setting, Dacor recommends using one on the same side to the higher power settings, power to E both controls on the right. See page 8 for more ...
...the magnetic induction cooking element. Below each cooking zone is totally different from hot pots or pans. Cooktop surface Cooking zone Style varies, model RNR30NS shown Cooktop Control Panel •A ON/OFF Key: Turns on the indicated cooking zone. •B Power Light: Turns on when the indicated...hard is lost heating the cooktop itself. At higher power settings, the induction element will stay on the keys can draw at a higher setting, Dacor recommends using one on the same side to the higher power settings, power to E both controls on the right. See page 8 for more ...