Page 1
... accompanying installation instructions. 30" (76.2 cm) 1 5/8" (4.1 cm) bottom of base to cooking surface 4" (10.2 cm) chassis height 21" (53.3 cm) 19 1/2" * (49.5 cm) 27 5/8" * (70.2 cm) * including embosses/screws in side of chassis 36" (91.4 cm) Product dimensions model sgm304 1 5/8" (4.1 cm...surface 21" (53.3 cm) 19 1/2" * (49.5 cm) * including embosses/screws in Gas Cooktops Revised 01/27/11 Page 1/5 PLANNING GUIDE All tolerances ±1/16" (±1.6 mm), unless otherwise noted. www.Dacor.com 44 5/8" * (113.3 cm) Product dimensions model sgm466 Phone: (800) 7934-0.5093 ...
... accompanying installation instructions. 30" (76.2 cm) 1 5/8" (4.1 cm) bottom of base to cooking surface 4" (10.2 cm) chassis height 21" (53.3 cm) 19 1/2" * (49.5 cm) 27 5/8" * (70.2 cm) * including embosses/screws in side of chassis 36" (91.4 cm) Product dimensions model sgm304 1 5/8" (4.1 cm...surface 21" (53.3 cm) 19 1/2" * (49.5 cm) * including embosses/screws in Gas Cooktops Revised 01/27/11 Page 1/5 PLANNING GUIDE All tolerances ±1/16" (±1.6 mm), unless otherwise noted. www.Dacor.com 44 5/8" * (113.3 cm) Product dimensions model sgm466 Phone: (800) 7934-0.5093 ...
Planning Guides
Page 2
..., 15 Amp. www.Dacor.com Phone: (800) 7934-0.6093 A copy of this standard may be easily disconnected if the unit needs service. Use only the regulator provided. Front of unit Product data label Gas inlet Electric cord Chassis Bottom Diagram Gas Supply Requirements ◊ ... off valve must meet the specifications stated below ). Gas and Electrical Requirements* * The electrical and gas data on the bottom of the cootktop in the shipping carton. SGM304, SGM365, SGM466 Document # PG04-004 30", 36", 46" Wide, Gas Cooktops Revised 01/27/11 Page 2/5 PLANNING GUIDE Electrical...
..., 15 Amp. www.Dacor.com Phone: (800) 7934-0.6093 A copy of this standard may be easily disconnected if the unit needs service. Use only the regulator provided. Front of unit Product data label Gas inlet Electric cord Chassis Bottom Diagram Gas Supply Requirements ◊ ... off valve must meet the specifications stated below ). Gas and Electrical Requirements* * The electrical and gas data on the bottom of the cootktop in the shipping carton. SGM304, SGM365, SGM466 Document # PG04-004 30", 36", 46" Wide, Gas Cooktops Revised 01/27/11 Page 2/5 PLANNING GUIDE Electrical...
Planning Guides
Page 3
Allow 7 1/2" (19.1 cm) from cooking surface (top of cooktop grate). 2 If installing with a raised vent, install only the approved Dacor model numbers specified below the cooktop. www.Dacor.com Phone: (800) 7934-0.7093 Document # PG04-004 SGM304, SGM365, SGM466 30", 36", 46" Wide, Gas Cooktops Revised 01/27/11 Page 3/5 PLANNING GUIDE Cabinet and Countertop Layout WARNING • To...
Allow 7 1/2" (19.1 cm) from cooking surface (top of cooktop grate). 2 If installing with a raised vent, install only the approved Dacor model numbers specified below the cooktop. www.Dacor.com Phone: (800) 7934-0.7093 Document # PG04-004 SGM304, SGM365, SGM466 30", 36", 46" Wide, Gas Cooktops Revised 01/27/11 Page 3/5 PLANNING GUIDE Cabinet and Countertop Layout WARNING • To...
Planning Guides
Page 4
... stiffener RV series raised vent: Check raised vent dimensions/specifications to determine proper fit Floor Side View - www.Dacor.com Phone: (800) 7934-0.8093 Carefully double check all dimensions against the table below and the correct diagram before cutting the....5 cm) 43 1/2" (110.5 cm) * Total cutout depth, accommodates both the cooktop and raised vent ** IMPORTANT: Notch depth is included in total cutout depth (D). Document # PG04-004 SGM304, SGM365, SGM466 30", 36", 46" Wide, Gas Cooktops Revised 01/27/11 Page 4/5 PLANNING GUIDE Cutout Dimensions Cutout tolerances +1/16" (+1.6 ...
... stiffener RV series raised vent: Check raised vent dimensions/specifications to determine proper fit Floor Side View - www.Dacor.com Phone: (800) 7934-0.8093 Carefully double check all dimensions against the table below and the correct diagram before cutting the....5 cm) 43 1/2" (110.5 cm) * Total cutout depth, accommodates both the cooktop and raised vent ** IMPORTANT: Notch depth is included in total cutout depth (D). Document # PG04-004 SGM304, SGM365, SGM466 30", 36", 46" Wide, Gas Cooktops Revised 01/27/11 Page 4/5 PLANNING GUIDE Cutout Dimensions Cutout tolerances +1/16" (+1.6 ...
Planning Guides
Page 5
... countertop E (both sides) 1 7/8" min. (4.8 cm) Figure 1 - www.Dacor.com Phone: (800) 7934-0.9093 from mounting surface to combustibles below cooktop chassis H 7 1/2" (19.1 cm) min. Square Countertop Cutout Diagram Rear wall Vertical combustible surface F G C H D 4 1/4" (10.8 cm) min. Document # PG04-004 SGM304, SGM365, SGM466 30", 36", 46" Wide, Gas Cooktops Cutout tolerances +1/16" (+1.6 mm), -0, unless otherwise noted Rear...
... countertop E (both sides) 1 7/8" min. (4.8 cm) Figure 1 - www.Dacor.com Phone: (800) 7934-0.9093 from mounting surface to combustibles below cooktop chassis H 7 1/2" (19.1 cm) min. Square Countertop Cutout Diagram Rear wall Vertical combustible surface F G C H D 4 1/4" (10.8 cm) min. Document # PG04-004 SGM304, SGM365, SGM466 30", 36", 46" Wide, Gas Cooktops Cutout tolerances +1/16" (+1.6 mm), -0, unless otherwise noted Rear...
Installation Instructions
Page 7
...installing the cooktop with a suitable vent hood or approved Dacor raised vent system. All tolerances +1/16" (+1.6 mm), -0 unless otherwise noted. See the following : • Access to the gas shut-... 3 Not applicable for the routing of gas and electrical service behind it is in the cabinet below : Cooktop Models SGM304 SGM365 SGM466 Approved Raised Vent Models ERV30,... more than a horizontal distance of 6" (15.2 cm) from edge of cooktop. to combustible side wall, above the cooktop. • Failure to rear See cutout dimensions 30" min.1, 2 (76.2 cm) 1 7/8" min. (4.8 cm) 7 ...
...installing the cooktop with a suitable vent hood or approved Dacor raised vent system. All tolerances +1/16" (+1.6 mm), -0 unless otherwise noted. See the following : • Access to the gas shut-... 3 Not applicable for the routing of gas and electrical service behind it is in the cabinet below : Cooktop Models SGM304 SGM365 SGM466 Approved Raised Vent Models ERV30,... more than a horizontal distance of 6" (15.2 cm) from edge of cooktop. to combustible side wall, above the cooktop. • Failure to rear See cutout dimensions 30" min.1, 2 (76.2 cm) 1 7/8" min. (4.8 cm) 7 ...