Fluke 192, 196, and 199 Scopemeter Datasheet
Page 1
...with SCC kit For more information, go to 48 hours, and FLUKE-196B/003S ScopeMeter 100 MHz B/W with SCC kit FLUKE-199B/003 ScopeMeter 200 MHz B/W FLUKE-199B/003S ScopeMeter 200 MHz B/W with SCC kit FLUKE-196C/003 ScopeMeter 100 MHz color Digital Persistence uses multiple intensity levels and user ...oscilloscopes offer of waveforms • 1000 V CAT II and 600 V CAT III safety certified • Five hours rechargeable Ni-MH battery pack In Trendplot or "paperless recorder" mode, you to 1000 V independently floating isolated inputs • Waveform reference for further analysis...
...with SCC kit For more information, go to 48 hours, and FLUKE-196B/003S ScopeMeter 100 MHz B/W with SCC kit FLUKE-199B/003 ScopeMeter 200 MHz B/W FLUKE-199B/003S ScopeMeter 200 MHz B/W with SCC kit FLUKE-196C/003 ScopeMeter 100 MHz color Digital Persistence uses multiple intensity levels and user ...oscilloscopes offer of waveforms • 1000 V CAT II and 600 V CAT III safety certified • Five hours rechargeable Ni-MH battery pack In Trendplot or "paperless recorder" mode, you to 1000 V independently floating isolated inputs • Waveform reference for further analysis...
FE 192,196,199 C Users Manual
Page 10
See Chapter 8. 6 7 3 4 9 10 11 b (2x) a 5 8 Figure 1. Fluke 192B - 196B/C - 199B/C Users Manual Unpacking the Test Tool Kit The following items are included in your test tool kit: 1 2 e (2x) (1x) f (2x) b a (2x) c (2x) (2x) d Note When new, the rechargeable NiMH battery is not fully charged. ScopeMeter Test Tool Kit 2
See Chapter 8. 6 7 3 4 9 10 11 b (2x) a 5 8 Figure 1. Fluke 192B - 196B/C - 199B/C Users Manual Unpacking the Test Tool Kit The following items are included in your test tool kit: 1 2 e (2x) (1x) f (2x) b a (2x) c (2x) (2x) d Note When new, the rechargeable NiMH battery is not fully charged. ScopeMeter Test Tool Kit 2
FE 192,196,199 C Users Manual
Page 11
# Description 1 ScopeMeter Test Tool 2 Battery Charger (country dependent) 3 10:1 Voltage Probe Set (red) a) 10:1 Voltage Probe (red) b) Hook Clip for Probe Tip (red) c) Ground Lead with Hook Clip (red) d) Ground ... with 4 mm banana jack 6 Getting Started Manual 7 CD ROM with Users Manual (multi-language) 8 Shipment box (basic version only) Unpacking the Test Tool Kit Fluke 192B, 196B/C and 199B/C S versions include also the following items: # Description 9 Optically Isolated USB Adapter/Cable 10 FlukeView® ScopeMeter® Software for Windows® 11 Hard Case 3
# Description 1 ScopeMeter Test Tool 2 Battery Charger (country dependent) 3 10:1 Voltage Probe Set (red) a) 10:1 Voltage Probe (red) b) Hook Clip for Probe Tip (red) c) Ground Lead with Hook Clip (red) d) Ground ... with 4 mm banana jack 6 Getting Started Manual 7 CD ROM with Users Manual (multi-language) 8 Shipment box (basic version only) Unpacking the Test Tool Kit Fluke 192B, 196B/C and 199B/C S versions include also the following items: # Description 9 Optically Isolated USB Adapter/Cable 10 FlukeView® ScopeMeter® Software for Windows® 11 Hard Case 3
FE 192,196,199 C Users Manual
Page 13
... than 4800 VA: • Use only insulated voltage probes, test leads and adapters supplied with the test tool, or indicated by Fluke as suitable for the Fluke190 ScopeMeter series. • Before use, inspect voltage probes, test leads and accessories for appliances and portable equipment. 5 Use caution when using...mechanical damage and replace when damaged. • Remove all probes, test leads and accessories that are not in use. • Always connect the battery charger first to the ac outlet before connecting it to the test tool. • Do not connect the ground spring (figure 1, item f)...
... than 4800 VA: • Use only insulated voltage probes, test leads and adapters supplied with the test tool, or indicated by Fluke as suitable for the Fluke190 ScopeMeter series. • Before use, inspect voltage probes, test leads and accessories for appliances and portable equipment. 5 Use caution when using...mechanical damage and replace when damaged. • Remove all probes, test leads and accessories that are not in use. • Always connect the battery charger first to the ac outlet before connecting it to the test tool. • Do not connect the ground spring (figure 1, item f)...
FE 192,196,199 C Users Manual
Page 96
... battery refresh date. 3 Return. Recalibration must be carried out by qualified personnel. For additional optional accessories, see the ScopeMeter Accessories booklet. To order replacement parts or additional accessories, contact your local Fluke ...representative for the various test tool models. Parts and Accessories The following tables list the user-replaceable parts for recalibration. 88 Contact your nearest service center. Fluke 192B - 196B/C - 199B...
... battery refresh date. 3 Return. Recalibration must be carried out by qualified personnel. For additional optional accessories, see the ScopeMeter Accessories booklet. To order replacement parts or additional accessories, contact your local Fluke ...representative for the various test tool models. Parts and Accessories The following tables list the user-replaceable parts for recalibration. 88 Contact your nearest service center. Fluke 192B - 196B/C - 199B...
FE 192,196,199 C Users Manual
Page 97
Replacement Parts Item Battery Charger, available models: Universal Europe 230 V, 50 and 60 Hz North America 120 V, 50 and 60 Hz United Kingdom 240 V, 50 and 60 Hz Japan ... BC190/807 BC190/808 VPS200-R 89 For other countries, a line plug adapter complying with Mini Alligator Clip (black) • Ground Spring for use with the Fluke ScopeMeter 190 series test tool. The set includes the following items (not available separately): • 10:1 Voltage Probe (red) • 4-mm Test Probe for Probe Tip...
Replacement Parts Item Battery Charger, available models: Universal Europe 230 V, 50 and 60 Hz North America 120 V, 50 and 60 Hz United Kingdom 240 V, 50 and 60 Hz Japan ... BC190/807 BC190/808 VPS200-R 89 For other countries, a line plug adapter complying with Mini Alligator Clip (black) • Ground Spring for use with the Fluke ScopeMeter 190 series test tool. The set includes the following items (not available separately): • 10:1 Voltage Probe (red) • 4-mm Test Probe for Probe Tip...
Fluke ScopeMeter Product Datasheet
Page 2
With up to www.fluke.com/scopemeter High sampling rates give you will act as 3000 samples per input..., they're ideal for detailed signal analysis. This enables you to identify the individual frequency components contained in a handheld, battery powered instrument. • Dual-input - 200, 100 or 60 MHz bandwidth • Up to 2.5 GS/s real-time...to a PC for 1000 V CAT II and 600 V CAT III safety certification • Four hours rechargeable NiMH battery pack See an on-line demonstration, go to 22 days • W aveform reference for visual comparisons and automatic...
With up to www.fluke.com/scopemeter High sampling rates give you will act as 3000 samples per input..., they're ideal for detailed signal analysis. This enables you to identify the individual frequency components contained in a handheld, battery powered instrument. • Dual-input - 200, 100 or 60 MHz bandwidth • Up to 2.5 GS/s real-time...to a PC for 1000 V CAT II and 600 V CAT III safety certification • Four hours rechargeable NiMH battery pack See an on-line demonstration, go to 22 days • W aveform reference for visual comparisons and automatic...
Fluke ScopeMeter Product Datasheet
Page 4
... of simultaneously measuring and checking waveforms. The unique Connect-and-View™ triggering automatically displays stable waveforms of battery operation frees you are fully supported. Fluke 125 Industrial ScopeMeter® Working under changing operational conditions. Battery powered mobility Up to seven hours of virtually any waveform found industrial network types are supported! • Power...
... of simultaneously measuring and checking waveforms. The unique Connect-and-View™ triggering automatically displays stable waveforms of battery operation frees you are fully supported. Fluke 125 Industrial ScopeMeter® Working under changing operational conditions. Battery powered mobility Up to seven hours of virtually any waveform found industrial network types are supported! • Power...
Fluke ScopeMeter Product Datasheet
Page 5
... mathematics Save set-ups and screens True-rms multimeter Safety, Power and Warranty Safety (EN61010-1) Battery Line power PC and printer interface Warranty 190C ScopeMeter Series 190B ScopeMeter Series 120 Series Fluke 199C Fluke 196C Fluke 199B Fluke 196B Fluke 192B Fluke 125 Fluke 124 Fluke 123 200 MHz 100 MHz 200 MHz 100 MHz 60 MHz 40 MHz 40 MHz 20...
... mathematics Save set-ups and screens True-rms multimeter Safety, Power and Warranty Safety (EN61010-1) Battery Line power PC and printer interface Warranty 190C ScopeMeter Series 190B ScopeMeter Series 120 Series Fluke 199C Fluke 196C Fluke 199B Fluke 196B Fluke 192B Fluke 125 Fluke 124 Fluke 123 200 MHz 100 MHz 200 MHz 100 MHz 60 MHz 40 MHz 40 MHz 20...