Fluke 54-2-B Support and Manuals

Get Help and Manuals for this Fluke item

View All Support Options Below
Free Fluke 54-2-B manuals!
Problems with Fluke 54-2-B?

Ask a Question

Popular Fluke 54-2-B Manual Pages

FE 53 & 54 II Users Manual - Page 2

... free from defects in material and workmanship for 3 years from accident, neglect, misuse or abnormal conditions of the problem. Box 9090 Everett WA 98206-9090 To register your defective tester to the nearest Fluke Authorized Service Center with a description of operation or handling. Resellers are not authorized to you. NO OTHER WARRANTIES, SUCH...
FE 53 & 54 II Users Manual - Page 5

...Fluke Model 53 and Model 54 Thermometers ("the thermometer") are microprocessor-based, digital thermometers designed to : Fluke Corporation P.O. Contacting Fluke To order accessories, receive assistance, or locate the nearest Fluke distributor or Service Center, call: 1-888-99-FLUKE (1-888-993-5853) in USA 1-800-36-FLUKE...fluke.com To register your product, visit www.fluke... USA Fluke Europe...
FE 53 & 54 II Users Manual - Page 6

... attention to the user. Protection may be impaired. 53 & 54 Series II Users Manual Table 1. When in doubt, have the thermometer serviced. • Do not operate the thermometer around the connectors. • Disconnect the thermocouple(s) from the thermometer before opening the case. • Replace the batteries as soon as marked on the thermometer, between...
FE 53 & 54 II Users Manual - Page 7

...the thermocouples, use electrically insulated thermocouples. • When servicing the thermometer, use only specified replacement parts. • Do not use the thermometer with any part of the battery with the battery case. 3 Safety Information (cont.) 53 & 54 Series II Safety Information WWarning (cont.) • Model 54: Measurement errors may damage the meter or the equipment under test...
FE 53 & 54 II Users Manual - Page 10

... an offset. Replace the batteries. E Setup is in progress. I The temperature units. Model 54: T1 or T2 reading. Display Elements 8 9 10 aat02f.eps 6 Table 4. See "Changing Setup Options." C A shift function is in SETUP. D Readings are displayed. H Primary Display. Model 54: T1, T2, or T1-T2 reading. L Time Display: 24-hour clock. 53 & 54 Series II Users Manual Display Elements...
FE 53 & 54 II Users Manual - Page 12

...display. 53 & 54 Series II Users Manual h T D K N E J r Table 5. Press E again to test the display. Buttons (cont.) Press h to increase the displayed setting. Press D to the Setup option you press J. Press J to start or exit Setup. (See "Changing Setup Options.") Press K to scroll to start or stop . 8 Press K to freeze or unfreeze the displayed readings. Model 54: Press T to...
FE 53 & 54 II Users Manual - Page 13

... 1 second the thermometer displays the first reading. The thermometer stores the settings in Setup mode, the display shows s. • Press D to change . Setup settings reset only when the batteries are removed for more than 2 minutes. 53 & 54 Series II Using the Thermometer Entering and Exiting Setup When the thermometer is "open," the display shows "- - - -." Notes Press...
FE 53 & 54 II Users Manual - Page 14

... press J, the thermometer stores the current readings in memory. 53 & 54 Series II Users Manual Changing the Logging Interval The logging interval determines how often the thermometer stores...: • Press K or N until the display shows INTERVAL. 2. You can also set the logging interval manually (0). Holding down K or N causes the number to display the logging interval choices. 3....
FE 53 & 54 II Users Manual - Page 15

...Errors." Changing the Thermocouple Type 1. See "Using the Offset to 0.0 when it is ± 5.0 oC or K, and ± 9.0 oF. Press E to indicate that you change the offset setting. Press E to change the thermocouple type. 11 Model 54... setting in memory. 53 & 54 Series II Changing Setup Options Changing the Offset You can store individual offsets for the errors of a specific ...
FE 53 & 54 II Users Manual - Page 16

... shows on the thermometer and is enabled each time you want to change the sleep setting. The right two digits blink. 4. Sleep mode is automatically disabled in MIN MAX and logging modes. 53 & 54 Series II Users Manual Enabling or Disabling Sleep Mode The thermometer enters sleep mode if no button press occurs...
FE 53 & 54 II Users Manual - Page 17

...Setup Options." 13 Changing the Line Frequency For optimum rejection of line noise, set the thermometer for the correct thermocouple type. Plug a thermocouple into the input connector(s). 2. Set... setting in memory. 53 & 54 Series II Measuring Temperatures Measuring Temperatures Connecting a Thermocouple Thermocouples are color coded by type based on the North American ANSI Color Code:...
FE 53 & 54 II Users Manual - Page 18

... temperature being measured is connected, the T2 reading appears in the selected display. 3. Model 54: If only thermocouple T2 is outside the thermocouple's valid range. Press G, M (CANCEL... the measurement location. The temperature reading appears in the primary display. 53 & 54 Series II Users Manual Displaying Temperatures 1. T 2. Viewing the MIN, MAX, and AVG Readings 1. ...
FE 53 & 54 II Users Manual - Page 20

... input. The thermometer stores 499 sets of temperature readings and one set of initial conditions when logging individual points manually. Press J to stop logging. 4. The display shows l. 3. Starting and Stopping Logging Setup, memory clear, and PC communications are a time stamp, the T1 reading, and the T2 and T1-T2 readings (Model 54). Press J again to start...
FE 53 & 54 II Users Manual - Page 23

... −40 oC to +60 oC Temperature (−40 oF to its accuracy specifications, Fluke recommends that you or follow the calibration procedure in the service manual listed in Table 1 before replacing the batteries. 1. Wipe with a damp sponge or soft rag. 53 & 54 Series II Maintenance Calibration To ensure that the thermometer performs to +140 oF...
FE 53 & 54 II Users Manual - Page 25

The above specifications do not include thermocouple error. 53 & 54 Series II Replacement Parts and Accessories Replacement Parts and Accessories Accessory Part Number Holster and Flex Stand™ Assembly 1272438 AA NEDA 15A IEC LR6 batteries 376756 80PK-1 K-Type Bead Thermocouple 773135 CD-ROM 1276106 Service Manual 1276123 21 Electrical (cont.) Measurement Accuracy, ...

Fluke 54-2-B Reviews

Do you have an experience with the Fluke 54-2-B that you would like to share?
Earn 750 points for your review!
We have not received any reviews for Fluke yet.

Popular Fluke 54-2-B Search Terms

The following terms are frequently used to search for Fluke 54-2-B support:

Ask a New Question
Use the box below to post a new question about Fluke 54-2-B.
Manuals / Documents
Download any of our Fluke 54-2-B manuals for free!

We have the following 1 documents available for the Fluke 54-2-B:
  • FE 53 & 54 II Users Manual
Related Items
View other Fluke Electronics Accessories:

Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

Fluke Manuals

Find free Fluke 54-2-B manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Fluke Reviews

View thousands of Fluke 54-2-B user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete Fluke customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed Fluke customer service rankings, employee comments and much more from our sister site.

Fluke Recalls

Find comprehensive Fluke recall information updated hourly on RecallOwl.com.