Fluke 374 600A/600V True-RMS AC/DC Clamp Meter
Duration: 1:24
Total Views: 10,848

Popular Fluke 374 Manual Pages

Fluke 375 and 374 Clamp Meter Product Datasheet - Page 1

... performance and flexibility The new Fluke 374 and 375 clamp meters offer improved performance perfect for use in noisy electrical environments while providing stable readings 374 and 375 True-rms AC/DC Clamp Meters Work horse clamps with other accessories (Fluke 375 only) • 1000 µF capacitance measurement Features • iFlex™ flexible current probe expands the measurement...
Fluke 375 and 374 Clamp Meter Product Datasheet - Page 2

..., backlight display automatically sets the correct measurement range so you do not need to change switch positions while taking a measurement • Three-year warranty • Soft carrying case Specifications Fluke 374 and 375 AC current via jaw AC current via iFlex™ (optional) DC current AC voltage DC voltage Resistance Frequency (375 only) Capacitance True-rms Continuity Hold Backlight...
Fluke 374, 375, 376 Users Manual - Page 1

Printed in China. All product names are subject to change without notice. All rights reserved. 374/375/376 Clamp Meter Users Manual PN 3608883 July 2010 © 2010 Fluke Corporation. Specifications are trademarks of their respective companies.
Fluke 374, 375, 376 Users Manual - Page 2

..., then send the product to that Service Center with a description of liability may not apply to extend any other warranty on Fluke's behalf. The Netherlands 11/99 Resellers...warranty or of incidental or consequential damages, this limitation of the problem. LIMITED WARRANTY AND LIMITATION OF LIABILITY This Fluke product will be free from defects in material and workmanship for...
Fluke 374, 375, 376 Users Manual - Page 5

... the 376 (optional with the 374 and 375) expands the measurement range to 2500 A ac. The Fluke 374, 375, and 376 (the Meter) measure true-rms ac current and voltage, dc current and voltage, inrush current, resistance, and capacitance. Introduction XWWarning Read "Safety Information" before you use the Meter. The illustrations in this manual show the 376. 1 The 375 and 376 also measure frequency...
Fluke 374, 375, 376 Users Manual - Page 6

... print, or download the latest manual supplement, visit http://us.fluke.com/usen/support/manuals. 2 374, 375, 376 Users Manual How to Contact Fluke To contact Fluke, call one of the following telephone numbers: • Technical Support USA: 1-800-44-FLUKE (1-800-443-5853) • Calibration/Repair USA: 1-888-99-FLUKE (1-888-993-5853) • Canada: 1-800-36-FLUKE (1-800-363-5853) • Europe...
Fluke 374, 375, 376 Users Manual - Page 7

...; Remove the test leads from the Meter before using the Meter. • Do not use the Meter. Carefully look at the insulation around the connectors. • Never measure current while the test leads are explained in doubt, have the Meter serviced. 3 Check test lead continuity. Protection can be compromised. Replace damaged test leads before the battery door...
Fluke 374, 375, 376 Users Manual - Page 8

..., properly installed in the Meter case, to power the Meter. • When measuring current with the conductor could result in an emergency. • Use extreme caution when working around voltages > 30 V ac rms, 42 V ac peak, or 60 V dc. 374, 375, 376 Users Manual • Do not use only specified replacement parts. • Have the Meter serviced only by qualified service personnel...
Fluke 374, 375, 376 Users Manual - Page 10

Go to equipment under test: • Use the proper jacks, function, and range for recycling information. 374, 375, 376 Users Manual WCaution To avoid possible damage to the Meter or to Fluke's website for the measurement application. • Clean the case and accessories with a damp cloth and mild detergent only. Do not use abrasives or solvents. X Hazardous...
Fluke 374, 375, 376 Users Manual - Page 12

...test probe accessory, current clamp accessory, and the Meter is the LOWEST rating of any individual component. 8 CAT IV CAT IV equipment has protection against transients in equipment in large buildings. 374, 375, 376 Users Manual Symbol Meaning Symbol..., and lighting systems in fixed-equipment installations, such as an electricity Meter or an overhead or underground utility service.
Fluke 374, 375, 376 Users Manual - Page 23

Specifications Electrical Specifications AC Current via Jaw Range 374 and 375 600.0 A 376 999.9 A Resolution 0.1 A Accuracy 2 % ± 5 digits (10-100 Hz) 2.5 % ± 5 digits (100-500 Hz) Crest Factor (50/60 Hz 3 @ 500 A (375 and 376 only) 2.5 @ 600 A 1.42 @1000 A (376 only) Add 2 % for C.F. > 2 Clamp Meters Specifications 19
Fluke 374, 375, 376 Users Manual - Page 24

374, 375, 376 Users Manual AC Current via Flexible Current Probe Range 2500 A Resolution 374 and 375 0.1 A (≤ 600 A) 1 A (≤ 2500 A) 376 0.1 A (≤ 999.9 A) 1 A (≤ 2500 A) Accuracy 3 % ±5 digits (5 - 500 Hz) Crest Factor (50/60Hz 3.0 at 1100 A (375 and 376 only) 2.5 at 1400 A 1.42 at 2500 A Add 2 % for C.F. > 2 20
Fluke 374, 375, 376 Users Manual - Page 26

374, 375, 376 Users Manual Distance from Optimum i2500-10 Flex i2500-18 Flex Error A 0.5 in (12.7 mm) 1.4 in (35.6 mm) ± 0.5 % B 0.8 in (20.3 mm) 2.0 in (50.8 mm) ± 1.0 % C 1.4 in (35.6 mm) 2.5 in (63.5 mm) ± 2.0 % Measurement uncertainty assumes centralized ...
Fluke 374, 375, 376 Users Manual - Page 27

374 and 375 600.0 V 376 1000 V Resolution 374 and 375 0.1 V 376 0.1 V (≤ 600.0 V) 1 V (≤ 1000 V) Accuracy 1.5 % ± 5 digits (20 - 500 Hz) DC Voltage Range 374 and 375 600.0 V 376 1000 V Clamp Meters Specifications 23
Fluke 374, 375, 376 Users Manual - Page 31

Clamp Meters Specifications Flexible Current Probe Diameter 7.5 mm Flexible Current Probe Cable Length (head to electronics connector 1.8 m Environmental Specifications Operating Temperature 10 °C - +50 °C Storage Temp 40 °C - +60 °C Operating Humidity Non condensing (< 10 - °C) ≤ 90 % RH (at 10 °C - 30 &#...

Fluke 374 Reviews

Do you have an experience with the Fluke 374 that you would like to share?
Earn 750 points for your review!
We have not received any reviews for Fluke yet.

Popular Fluke 374 Search Terms

The following terms are frequently used to search for Fluke 374 support:

Ask a New Question
Use the box below to post a new question about Fluke 374.
Manuals / Documents
Download any of our Fluke 374 manuals for free!

We have the following 2 documents available for the Fluke 374:
  • Fluke 374, 375, 376 Users Manual
  • Fluke 375 and 374 Clamp Meter Product Datasheet
Related Items
View other Fluke Electronics Accessories:

Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

Fluke Manuals

Find free Fluke 374 manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Fluke Reviews

View thousands of Fluke 374 user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete Fluke customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed Fluke customer service rankings, employee comments and much more from our sister site.

Fluke Recalls

Find comprehensive Fluke recall information updated hourly on RecallOwl.com.