FE 975 Users Manual
Page 4
975 Users Manual CO Alarm ...10 The Setup Menu ...10 Taking Measurements 11 Temperature, Relative Humidity, CO, CO , Dew Point, and Wet Bulb 2 Measurements ...11 % Outside Air ...11 % Outside Air (Temperature 12 % Outside Air (CO 12 2 Air Velocity and Volume Flow Rate 13 Standard Velocity and Actual Velocity 13 Velocity Probe ...13 Measuring Air... the CO and CO2 Sensors 20 Calibrating the CO Sensor 21 Calibrating the CO Sensor 21 2 Maintenance ...24 Cleaning the Meter...24 Battery Maintenance and Battery Charge Indicators 24 Charging the Battery and Using the Power Adapter 25 ii
975 Users Manual CO Alarm ...10 The Setup Menu ...10 Taking Measurements 11 Temperature, Relative Humidity, CO, CO , Dew Point, and Wet Bulb 2 Measurements ...11 % Outside Air ...11 % Outside Air (Temperature 12 % Outside Air (CO 12 2 Air Velocity and Volume Flow Rate 13 Standard Velocity and Actual Velocity 13 Velocity Probe ...13 Measuring Air... the CO and CO2 Sensors 20 Calibrating the CO Sensor 21 Calibrating the CO Sensor 21 2 Maintenance ...24 Cleaning the Meter...24 Battery Maintenance and Battery Charge Indicators 24 Charging the Battery and Using the Power Adapter 25 ii
FE 975 Users Manual
Page 11
The Fluke 975 AirMeterTM Test Tool ("the Meter") is a hand-held, five-sensor indoor air quality diagnostic instrument. The Meter comes with available international adapters • Multi-language user interface (English, French, German, Portuguese, and Spanish) • ... • Carbon dioxide (CO ) levels measured in ppm. 2 • Air velocity (standard and actual) measured in mps or fpm. • % outside air based on temperature or CO . 2 • Flow rate displayed in this manual. 975 AirMeter TM Test Tool Introduction WWarning Read "Safety Information" before using the...
The Fluke 975 AirMeterTM Test Tool ("the Meter") is a hand-held, five-sensor indoor air quality diagnostic instrument. The Meter comes with available international adapters • Multi-language user interface (English, French, German, Portuguese, and Spanish) • ... • Carbon dioxide (CO ) levels measured in ppm. 2 • Air velocity (standard and actual) measured in mps or fpm. • % outside air based on temperature or CO . 2 • Flow rate displayed in this manual. 975 AirMeter TM Test Tool Introduction WWarning Read "Safety Information" before using the...
FE 975 Users Manual
Page 16
... Pushbuttons Softkey or Pushbutton Function Softkeys- A2ctivates the Temperature, Relative Humidity, CO and CO , Wet Bulb, and Dew Point functions.2 % Outside Air- Activates the % Outside Air menu. 975 Users Manual Using the Meter The following sections explain how to select different functions. Softkeys and Pushbuttons Use the softkeys to navigate among different menus or to...
... Pushbuttons Softkey or Pushbutton Function Softkeys- A2ctivates the Temperature, Relative Humidity, CO and CO , Wet Bulb, and Dew Point functions.2 % Outside Air- Activates the % Outside Air menu. 975 Users Manual Using the Meter The following sections explain how to select different functions. Softkeys and Pushbuttons Use the softkeys to navigate among different menus or to...
FE 975 Users Manual
Page 21
... on the top right of the display. If the Meter is displaying dew point temperature). The 2 values can be entered manually. The dew point reading appears on outside air, and mixed air into the formula. Mixed Air) x 100 % Return Air - These values can be measured with the Meter or, in some cases [Done], to exit the Setup...
... on the top right of the display. If the Meter is displaying dew point temperature). The 2 values can be entered manually. The dew point reading appears on outside air, and mixed air into the formula. Mixed Air) x 100 % Return Air - These values can be measured with the Meter or, in some cases [Done], to exit the Setup...
FE 975 Users Manual
Page 22
... change the CO 2 The Meter then measures and displays the mixed air temperature. 5. 975 Users Manual variables are displayed. Outside air temperature can either be measured by 2 using 1[Capture] or it can be entered manually by pressing 2[Manual Entry] and entering the known outside air using 1[Capture] or it can be entered manually by pressing 2[Manual Entry] and entering the...
... change the CO 2 The Meter then measures and displays the mixed air temperature. 5. 975 Users Manual variables are displayed. Outside air temperature can either be measured by 2 using 1[Capture] or it can be entered manually by pressing 2[Manual Entry] and entering the known outside air using 1[Capture] or it can be entered manually by pressing 2[Manual Entry] and entering the...
FE 975 Users Manual
Page 24
...in inches (if the Meter is to Metric measurements, enter units in centimeters). 5. Note The Meter can take up to the flow rate sample. 11. The probe will initialize. 3. Press 1[Capture]. 975 Users Manual 5. Measuring Volume Flow Rate The formula for measuring the air flow volume rate is set... to multiply the area of the air-duct opening by the average...
...in inches (if the Meter is to Metric measurements, enter units in centimeters). 5. Note The Meter can take up to the flow rate sample. 11. The probe will initialize. 3. Press 1[Capture]. 975 Users Manual 5. Measuring Volume Flow Rate The formula for measuring the air flow volume rate is set... to multiply the area of the air-duct opening by the average...
FE 975 Users Manual
Page 26
... • Relative humidity • Wet bulb • Dew point • CO • CO 2 • Air velocity (if the probe is full, the entire memory must be stored. Start a desired measurement. 2. Press 1[ENTER... The data is the measurement that was displayed when Lwas pressed is saved and the Meter returns to the screen where the data originally was taken. Up to the next changeable ... on the display. Values displayed using Min, Max, or Avg functions cannot be saved. 3. 975 Users Manual To save data taken over a period of samples Logging can be erased to 99 hours. The...
... • Relative humidity • Wet bulb • Dew point • CO • CO 2 • Air velocity (if the probe is full, the entire memory must be stored. Start a desired measurement. 2. Press 1[ENTER... The data is the measurement that was displayed when Lwas pressed is saved and the Meter returns to the screen where the data originally was taken. Up to the next changeable ... on the display. Values displayed using Min, Max, or Avg functions cannot be saved. 3. 975 Users Manual To save data taken over a period of samples Logging can be erased to 99 hours. The...