All product names are subject to change without notice. MyFlukeStore Shop for Fluke products online at: www. .com 1.877.766.5412 Ti200, Ti300, Ti400 Thermal Imagers Users Manual PN 4281773 September 2013 © 2013 Fluke Corporation. Specifications are trademarks of their respective companies. All rights reserved.
Product Manual - Page 7

...Focus System, as well as advanced manual focus capabilities. They also include many applications. SmartView® Mobile software is a highperformance, professional software suite that allows for quality analysis and reporting. Introduction The Fluke Ti200, Ti300, and Ti400 Thermal Imagers (the Product or Imager) are handheld, infrared imaging cameras for use on a high-visibility...
Product Manual - Page 11

... licenses on how to install a lens. 5 MyFlukeStore Shop for Fluke products online at: www. .com 1.877.766.5412 See Figure 2 for information about how to access digital copies of the accessories available for the Imager. Thermal Imagers Radio Frequency Data Radio Frequency Data See page 39 for instructions on the Imager. Table 2. Accessories Model FLK-TI-SBP3 Description...
Product Manual - Page 16

... features. Note All thermal imagers need sufficient warm-up time for two seconds, see Table . If this occurs, let the Imager stabilize (cool down or warm up in Extreme Conditions Storage and/or continual operation of 10 minutes if the most accurate temperature measurements and best image quality. Ti200, Ti300, Ti400 Users Manual Optional 12 V Vehicle...
Product Manual - Page 21

... image. Focus on the object using the LaserSharp™ Auto Focus System or advanced manual focus (See page 13 on the selected file format settings, the Imager shows the captured image ... buttons and arrow buttons, are the access for thermal image display, camera features, measurement, advanced functions, memory review, and settings for Fluke products online at the object or area of a...
Product Manual - Page 25

Thermal Imagers Micro SD Memory Card Micro SD Memory Card To eject a Micro SD memory card, push in until it . To use the Micro SD memory card, make sure that the write-protect lock is open. For information about how to view or erase a stored image..., see page 18. The Micro SD memory card comes with an SD adapter for Fluke products online at: www. .com ...
Product Manual - Page 27

...the new selection. Go to adjust the span setting. See the section, Detailed Specifications, for more information about the minimum span. 21 MyFlukeStore Shop for automatic or manual adjustment. Measurement Menu The Measurement Menu has settings for date, time, language, units, file format, and Imager information. Thermal Imagers Menus Menus The menus, together with the three...
Product Manual - Page 28

This feature operates the Imager in the same Level and Span mode, Auto or Manual, as when it moves to automatically rescale the level and span range for Manual Operation Mode When put into manual ranging, the level setting moves the thermal span up in a semi-automatic mode if manual fine re-adjustment of view. Rescaling can be...
Product Manual - Page 29

... that the Imager observes. Emissivity Adjustment The correct emissivity values are always available to obtain more accurate temperature measurements. 23 MyFlukeStore Shop for Manual Operation Mode When in manual mode, the span setting contracts or expands in a selected palette in size. While you to adjust the level and span. Level Thermal Imagers Menus Total Imager Range Span...
Product Manual - Page 31

... as τ = xx. 25 MyFlukeStore Shop for reflected background temperature is set to change the value. 3. Push / to Measurement > Transmission....see Emissivity Adjustment. Push  or  when done. Thermal Imagers Menus Background (Reflected Background Temperature Compensation) Compensation for Fluke products online at: www. .com 1.877.766.5412 To ...
Product Manual - Page 33

... 27 MyFlukeStore Shop for Fluke products online at: www. .com 1.877.766.5412 Push / to Measurement > Center Box. 2. Push  to highlight Set Size. 2. The zone ... in AUTO Level and Span mode, the Imager automatically sets the level and span according the infrared scene within the infrared image. Thermal Imagers Menus Center Box The Center Box feature is...
Product Manual - Page 35

... precisely where a potential problem might be customized or separated in -Picture (PIP) AutoBlend (min, mid, max) Full AutoBlend (min, mid, max) Visible Note The visible image and infrared image can choose as off, standard, red/blue, or white/black. The Imager automatically captures a visible image with every infrared image to set the new palette. Thermal Imagers Menus To switch...
Product Manual - Page 37

... Display All, Details and Scale, Scale Only, and Image Only. Push  or  set . Go to Image > Color Alarm > Outside or Inside. 2. Push  to highlight on the display and captured images. Logo A Fluke logo shows on or off. 3. Thermal Imagers Menus Outside/Inside Alarm If you set values for the high-temperature color alarm and a low...
Product Manual - Page 47

... dangerous to the USB port on the PC. Thermal Imagers Remote Control (Ti400) Remote Control (Ti400) The Ti400 Imager can be remotely controlled with a damp cloth and a weak soap solution. Follow the instructions in the SmartView workspace. Have the Product repaired only through an approved technical site. If not installed, install the latest version of the cable to clean the...
Product Manual - Page 51

Thermal Imagers Detailed Specifications Detailed Specifications Temperature Measurements Temperature Range (not calibrated below -10 °C) Ti200, Ti300 20 °C to +650 °C Ti400 20 °C to +1200 °C Accuracy 2 °C or 2 % (whichever is greater) at 25 °C ambient On-screen emissivity correction all models On-screen reflected background temperature compensation all ...

Fluke TI400-60HZ Reviews

Do you have an experience with the Fluke TI400-60HZ that you would like to share?
Earn 750 points for your review!
We have not received any reviews for Fluke yet.

Popular Fluke TI400-60HZ Search Terms

The following terms are frequently used to search for Fluke TI400-60HZ support:

Ask a New Question
Use the box below to post a new question about Fluke TI400-60HZ.
Manuals / Documents
Download any of our Fluke TI400-60HZ manuals for free!

We have the following 1 documents available for the Fluke TI400-60HZ:
  • Product Manual
Related Items

Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

Fluke Manuals

Find free Fluke TI400-60HZ manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Fluke Reviews

View thousands of Fluke TI400-60HZ user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete Fluke customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed Fluke customer service rankings, employee comments and much more from our sister site.

Fluke Recalls

Find comprehensive Fluke recall information updated hourly on RecallOwl.com.