Popular Fluke 87V/IMSK Manual Pages
Product Manual - Page 4
... the MIN MAX Recording Mode 24 Measuring Frequency 26 Measuring Duty Cycle 27 Pulse Width Measurements 29 Maintenance ...29 General Maintenance 29 Calibration...30 Battery Replacement 30 Fuse Test W...30 Fuse Replacement W 32 Service W...32 Replaceable Parts ...33 Specifications...36
ii
MyFlukeStore Shop for Fluke products online at: www.
.com 1.888.610.7664
Product Manual - Page 9
...the proper function and range for the Service Manual part number.
• CAT III: For making measurements on equipment in fixed installations (industrial). Save the shipping container and...Fluke products online at: www.
.com 1.888.610.7664 MyFlukeStore Shop for conditions and actions that may damage your meter. Warning
To avoid electrical shock, use only parts listed in the Service Manual...
Product Manual - Page 10
Disconnect the input power and discharge all safety procedures for Fluke products online at: www.
.com 1.888.610.7664 Notice ...Electrical Symbols
B AC-Alternating
Current
W
See Explanation in the appropriate input terminals (see Table 2).
Insert the test leads in Manual
F DC-Direct
Current
T
Double insulation (Protection Class II
C Either DC or AC I Fuse
J Ground
• Disconnect...
Product Manual - Page 13
... part of this procedure will emit an Input Alert. For ease of reference, each description is moved from OFF to a function setting,... the function selector switch is set to the illustration inside the front cover. Although this manual so that you take the ... is set to
B mA µA Milliamp/Microamp Input Terminal
^\ For current measurements up to 10A
^\ continuous (20A for Fluke products ...
Product Manual - Page 14
Single 0-3V range.
7
MyFlukeStore Shop for Fluke products online at approximately 0.5 mA test current.
How to Use the Meter
In Manual Ranging mode, 40 nS conductance range (equal to a 25-100,000 MΩ range) is turned off. l Millivolts dc
Single 400 mV range.
Press BLUE button ...
Product Manual - Page 15
...A summary of pushbutton operations is updated once per second.
Autoranges to toggle between dc and ac.
Pushbuttons
Items 6-13 describe how to select operating modes and set to ReE
MyFlukeStore Shop for best...unless the beeper has been turned off automatically after 68 seconds to dc. Use manual ranging for Fluke products online at 19,999 counts. Autoranges to the 40 mA or 400 mA...
Product Manual - Page 19
...
Touch hold to any switch setting.
Power-On Option: Disable Beeper
When the beeper has been disabled, all beeper functions are disabled. See the 80 Series Service Manual for Fluke products online at: www.
...press Iagain to negative-going edges to start it.
The slope selected is automatically updated.
press Iagain to exit Touch Hold and enter the MIN MAX Recording mode.
...
Product Manual - Page 21
...4½ digit display. The display updates four times per second. O
Analog Display
The analog display is a 32-segment pointer that are changing. See 80 Series Service Manual Enable ultrasonic data transmission. (For ... Frequency Counter functions or in the Peak MIN MAX mode.
14
MyFlukeStore Shop for Fluke products online at Power-on , all beeper functions Provides >4000 MΩ input ...
Product Manual - Page 27
...To perform audible continuity tests, set the rotary switch to ReE ... To determine the error, short the test ...MyFlukeStore Shop for Fluke products online at ... extremely fast and can be a valuable troubleshooting aid when looking for intermittents associated with ...of the leads. 87 Users Manual
To calculate the burden voltage...code. If the test value is usually 0.1 to emit a continuous tone.
Product Manual - Page 28
.... The input receptacles have split contacts; To measure conductance, set the rotary switch to MJ and press Kto manually increment to conduct. Plug the test leads into 1000 (1000... (1000/2.00). Fullscale measurement voltage in units of conductance (nS). Applications
Using Conductance for Fluke products online at: www.
.com 1.888.610.7664
For example 2.00 nS converts to...
Product Manual - Page 35
... is flowing in percent):
28
MyFlukeStore Shop for Fluke products online at: www.
.com 1.888.610.7664 Dwell is similar to pulse-width averaging in an automobile. 87 Users Manual
+Slope Trigger Point
30% +Slope
-Slope Trigger..."dwell" angle in a conventional counter) may cause a measurement problem called "aliasing." A common duty cycle measurement is "blind" to the average display.
Product Manual - Page 36
... 100 360 degrees
To make a dwell measurement, set the rotary switch to pulse width. Most automobiles have...off " or points closed for part number). Since the oiling agent ... Input Alerts.
29
MyFlukeStore Shop for Fluke products online at equal time intervals), .../ 100 Frequency
Maintenance
Maintenance
Repairs or servicing not covered in the 80 Series Service Manual (refer to dislodge and ...
Product Manual - Page 37
... test leads from any input signals before replacing the battery or fuses. Snap the battery connector leads to the 80 Series Service Manual for Fluke products online at the end nearest the ...Service Center or refer to the terminals of the case top until it performs according to its specifications. Referring to Figure 4, use the following procedure to test the internal fuses of this manual...
Product Manual - Page 39
....
2. Service
If the meter fails, check the battery and fuse(s) and replace as needed. Fluke assumes NO responsibility for Fluke products online at the end near the LCD) are properly dressed, and the two snaps on the case top (at : www.
.com 1.888.610.7664 87 Users Manual
K 1. Perform steps 1 through 3 of the fuse bracket...
Product Manual - Page 41
...
TM3
Service Manual, CAT III labeled meters
617826
all other meters
834168
TM4
Quick Reference Guide, Fluke 80 Series
844290
1
TL20**
Industrial Test Lead Set (Optional)
TL75**
Test Lead Set
1
C81Y**
Holster, Yellow
1
C81G**
Holster, Gray (Optional)
C25**
Carrying Case, Soft (Optional)
P To ensure safety, use exact replacement...