Popular Fluke Ti300 Manual Pages

User Manual - Page 4

... Users Manual Menus 21 Measurement Menu 21 Range 21 Level/Span 21 Emissivity Adjustment 23 Background (Reflected Background Temperature Compensation 25 Transmission/Transmittance Adjustment 25 Spot Temperatures 26 Spot Markers 26 Center Box 27 Image Menu 28 Palette 28 IR-Fusion® Technology 29 Color Alarms 30 Display Graphics Presentation 31 Logo 31 Camera...
User Manual - Page 7

... memory card. They also include many applications. These applications include equipment troubleshooting, preventive and predictive maintenance, building diagnostics, and research and development. Introduction The Fluke Ti200, Ti300, and Ti400 Thermal Imagers (the Product or Imager) are handheld, infrared imaging cameras for use on a high-visibility, industrial-quality 640 x 480 LCD touch...
User Manual - Page 8

.... Ti200, Ti300, Ti400 Users Manual How to eyes. Safety Information A Warning identifies conditions and procedures that can cause damage to the user. Have the Product repaired only through an approved technical site. 2 Do not point laser directly at www.fluke.com. To view, print, or download the latest manual supplement, visit http://us.fluke.com/usen/support/manuals. To register...
User Manual - Page 10

.... Ti200, Ti300, Ti400 Users Manual • See emissivity information for recycling information. Battery removed.  Battery status. Conforms to the equipment types in sunlight. Go to ac power. Product Category: With reference to requirements of by a qualified recycler or hazardous materials handler per local regulations. Contact your authorized Fluke Service Center for...
User Manual - Page 18

Ti200, Ti300, Ti400 Users Manual Item Table 3. Features and Controls (cont.) Description Hand Strap Manual Focus Control 2-Bay Battery Charging Base AC Power Supply ... LED Torch/Flashlight  Retractable Lens Cover  Visual Light Camera Lens  Laser Pointer/Range Finder  Infrared Camera Lens  Secondary Trigger  Primary Trigger 12 hie06.eps
User Manual - Page 26

The Imager senses the infrared energy from the surface of For surfaces that are very good at radiating energy (high emissivity), the emissivity ...materials such as they have an emissivity of the object and uses this data to get relatively accurate measurements. Ti200, Ti300, Ti400 Users Manual Temperature Measurement All objects radiate infrared energy. The quantity of the object.
User Manual - Page 28

...Manual Operation Mode When put into manual ranging, the level setting moves the thermal span up in a semi-automatic mode if manual fine re-adjustment of view. This feature operates the Imager in the same Level and Span mode, Auto or Manual... 22 Ti200, Ti300, Ti400 Users Manual Fast Auto/Manual Range Toggle When NOT in the upper right-hand corner of the display shows the thermal span as needed...
User Manual - Page 29

... for Manual Operation Mode When in manual mode, the span setting contracts or expands in a selected palette in size. To adjust the temperature span: 1. Push  to decrease or narrow the temperature span. Emissivity Adjustment The correct emissivity values are always available to obtain more accurate temperature measurements. 23 Level Thermal Imagers Menus Total Imager Range...
User Manual - Page 34

Ti200, Ti300, Ti400 Users Manual Image Menu The Image menu has controls for different features used in the presentation of detail. The Standard Palettes offer an equal, linear presentation of colors that allow for best presentation of the infrared image on display or captured. Palettes Standard Palettes Ultra Contrast™ Palettes Grayscale Grayscale Ultra Grayscale ...
User Manual - Page 36

...  set these parameters. Ti200, Ti300, Ti400 Users Manual Color Alarms The Imager has various apparent temperature color alarms. The hightemperature color alarm shows a full visible image and only shows infrared information on objects or areas that are above the set apparent temperature alarm level. The user must manually determine and set the new value. Set Low-Temperature...
User Manual - Page 38

... System The laser pointer on the specific area of the display when you pull the secondary trigger. The auto focus system will quickly and accurately focus on or off. 3.  to set the change and go back to select on the object. 32 Ti200, Ti300, Ti400 Users Manual Camera Menu The Camera menu has controls and options...
User Manual - Page 42

... special software. Push / to highlight LCD Time Out or Power Off. 3. Visit the Fluke website or contact Fluke to find out how to AC Power. Push  to set the Auto Off feature: 1. Note Auto Off is automatically disabled when the battery is not, choose the .bmp file format. Ti200, Ti300, Ti400 Users Manual...
User Manual - Page 46

... to view the information screen with the specific license agreement. 6. Push  to view the information screen with a list of Open Source Software Licenses. 4. Touch the license name on a PC. 3. Push  to Settings > Advanced > Imager Info. 2. To set up : 1. Go to close the information screen. Ti200, Ti300, Ti400 Users Manual To display the license information: 1.
User Manual - Page 48

... to prevent battery leakage and damage to charge the batteries in the sun. Go to Fluke's website for full capacity. • Always operate in the specified temperature range. •...Imager on the charger for more than 24 hours as an unattended vehicle in extreme cold environments.   Caution Do not incinerate the Product and/or battery. Ti200, Ti300, Ti400 Users Manual...
User Manual - Page 52

... 45 cm (18 in) Optional wide-angle infrared lens Field of View 46 ° x 34 ° Spatial Resolution (IFOV) Ti400 2.62 mRad Ti300 3.49 mRad Ti200 4.19 mRad Minimum Focus Distance 15 cm (6 in) Focus Mechanism LaserSharp™ Auto Focus System all models Advanced Manual Focus all models Image Presentation Standard Palettes Blue-Red, Grayscale, Inverted...

Fluke Ti300 Reviews

Do you have an experience with the Fluke Ti300 that you would like to share?
Earn 750 points for your review!
We have not received any reviews for Fluke yet.

Popular Fluke Ti300 Search Terms

The following terms are frequently used to search for Fluke Ti300 support:

Ask a New Question
Use the box below to post a new question about Fluke Ti300.
Manuals / Documents
Download any of our Fluke Ti300 manuals for free!

We have the following 1 documents available for the Fluke Ti300:
  • User Manual
Related Items

Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

Fluke Manuals

Find free Fluke Ti300 manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Fluke Reviews

View thousands of Fluke Ti300 user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete Fluke customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed Fluke customer service rankings, employee comments and much more from our sister site.

Fluke Recalls

Find comprehensive Fluke recall information updated hourly on RecallOwl.com.